Loading...
HomeMy WebLinkAboutRESO - PC - 2025-09.08-7A DSR22-0006 PC/09/08/2025 Page 1 CITY OF BURLINGAME PLANNING COMMISSION RESOLUTION 2025-09.08-7A APPROVING MAJOR DESIGN REVIEW AND HILLSIDE AREA CONSTRUCTION PERMIT FOR 1812 CASTENADA DRIVE PROJECT NO. DSR22-0006 WHEREAS, an application has been made by Yury Kogan, on behalf of Property Owner, Marat Diner, for Major Design Review and Hillside Area Construction Permit for a first and second story addition to an existing single-unit dwelling in the R-1 (Low Density Residential) zoning district, APN: 025-091-200; and WHEREAS, on September 8, 2025, the Planning Commission of the City of Burlingame held a duly noticed public hearing at which time it reviewed and considered the staff report and all other written materials and testimony presented at said hearing; and WHEREAS, on September 8, 2025, the Planning Commission of the City of Burlingame reviewed and considered a Categorical Exemption under Section 15301(e)(1) (Class 1, Existing Facilities) for the Project; and NOW, THEREFORE, the Planning Commission of the City of Burlingame does here by resolve, find, determine and order as follows: SECTION 1: The project is Categorically Exempt from the California Environmental Quality Act (CEQA) pursuant to Section 15301(e)(1) (Class 1 – Existing Facilities) of the CEQA Guidelines, which states that additions to existing structures are exempt from environmental review, provided the addition will not result in an increase of more than 50% of the floor area of the structures before the addition. SECTION 2: City of Burlingame Municipal Code (BMC) authorizes the Planning Commission to grant Major Design Review and Hillside Area Construction Permit upon making certain findings. The Planning Commission finds the following: MAJOR DESIGN REVIEW FINDINGS (BMC SECTION 25.68.060.H.) 1. The project is consistent with the General Plan and is in compliance with all applicable provisions of Title 25, all applicable design guidelines, all other City ordinances and regulations, and the standards established in BMC Section 25.68.060 (C). The proposed addition to the single-unit dwelling is consistent with the General Plan designation of Low Density Residential and is in compliance with all applicable provisions of Title 25; the proposed addition to the dwelling is consistent with the design guidelines in matching the style of the existing house with horizontal siding and hipped roofs; that the mass and bulk of the proposed structure is in scale with the lot and in relation to neighboring properties in that the addition is centered over the existing first floor; that the proposed landscaping will add an additional street tree to soften the impacts of the second floor; and that upgraded materials such as aluminum clad windows and enhanced design features such as a larger porch make the project compatible with the character of the neighborhood. Docusign Envelope ID: B6A9083D-D856-4BBB-8543-E17D19FE111C DSR22-0006 PC/09/08/2025 Page 2 2. The project will be constructed on a parcel that is adequate in shape, size, topography, and other circumstances to accommodate the proposed development. The project will be constructed on a parcel that is adequate in shape, size, topography, and other circumstances to accommodate the proposed development as shown on the proposed plans. 3. The project is designed and arranged to provide adequate consideration to ensure the public health, safety, and general welfare, and to prevent adverse effects on neighboring property. The project is designed and arranged to provide adequate consideration to ensure the public health, safety, and general welfare, and to prevent adverse effects on neighboring property because the project complies with setback, lot coverage, floor area ratio, height, declining height envelope, and parking requirements. HILLSIDE AREA CONSTRUCTION PERMIT FINDINGS (BMC SECTION 25.70.040) 1. The project is consistent with the purpose of the Hillside Overlay Zone. The purpose of the Hillside Overlay Zone (BMC section 25.20.040) is to protect public health and safety by minimizing hazards, including soil erosion and fire danger associated with development on hillsides; preserve and enhance the City's scenic character, including its natural hillsides and views of San Francisco Bay; respect natural features in the design and construction of hillside development; and design hillside development to be sensitive to existing terrain, distant views, and significant natural landforms and features. The proposed project is consistent with the purpose of the Hillside Overlay Zone in that 1) the proposed second floor plate height (8’-0”) and overall roof height (24’-4”) are at or below the maximums to limit the potential of blocking existing distant views of San Francisco Bay from neighboring houses, 2) the trees to be planted as part of the project are selected from the Parks Division’s Hillside View Area Trees list which includes species that are of only small or medium height and have narrow crowns to reduce potential view blockage, and 3) there are no changes proposed to the existing terrain and natural land forms with the project. 2. The project complies with the development standards found in Section 25.20.040.B through I. The proposed project complies with the development standards found in Section 25.20.040.B. through I. in that the first and second floor addition is designed and located in a manner that preserves existing distant views to San Francisco Bay from primary indoor living areas with 8- foot second floor plate heights, a roof ridge that is more than five feet lower than the maximum allowed by code regulations, and hipped roof forms. The proposed project locates the additions on the existing level area of the site or above the existing first floor which does not require any grading. 3. The placement of the proposed construction does not have a substantial impact on adjacent properties or on the character of the immediate neighborhood. The proposed construction will not have a substantial impact on adjacent properties or on the character of the immediate neighborhood in that 1) the second floor addition exceeds required setbacks, the 8-foot second floor plate height and hipped roofs minimize the massing for the addition and impacts on surrounding properties, 3) the proposed balcony is centered at the rear of the addition which increases the side setbacks to neighboring properties (23’-4” from the right side property line and 43’-4” from the rear property line), and 4) the project has been Docusign Envelope ID: B6A9083D-D856-4BBB-8543-E17D19FE111C DSR22-0006 PC/09/08/2025 Page 3 designed to be consistent with the character of neighboring properties with ranch-style houses and attached garages. SECTION 3: The Planning Commission of the City of Burlingame after conducting the public hearing HEREBY APPROVES DSR22-0006 subject to the following conditions: CONDITIONS OF APPROVAL 1. that the project shall be built as shown on the plans submitted to the Planning Division and date stamped July 9, 2025, sheets T1.0 through D1.0; and that for the building permit submittal the plans shall include one additional 24-inch box size landscape tree (three total landscape trees) within the private property; 2. that any changes to building materials, exterior finishes, windows, architectural features, roof height or pitch, and amount or type of hardscape materials shall be subject to Planning Division or Planning Commission review. 3. that any changes to the size or envelope of the basement, first or second floors, or garage, which would include adding or enlarging a dormer(s), shall require an amendment to this permit; 4. that any recycling containers, debris boxes or dumpsters for the construction project shall be placed upon the private property, if feasible, as determined by the Community Development Director; 5. that demolition for removal of the existing structures and any grading or earth moving on the site shall not occur until a building permit has been issued and such site work shall be required to comply with all the regulations of the Bay Area Air Quality Management District; 6. that prior to issuance of a building permit for construction of the project, the project construction plans shall be modified to include a cover sheet listing all conditions of approval adopted by the Planning Commission, or City Council on appeal; which shall remain a part of all sets of approved plans throughout the construction process. Compliance with all conditions of approval is required; the conditions of approval shall not be modified or changed without the approval of the Planning Commission, or City Council on appeal; 7. that all air ducts, plumbing vents, and flues shall be combined, where possible, to a single termination and installed on the portions of the roof not visible from the street; and that these venting details shall be included and approved in the construction plans before a Building permit is issued; 8. that the project shall comply with the Construction and Demolition Debris Recycling Ordinance which requires affected demolition, new construction and alteration projects to submit a Waste Reduction plan and meet recycling requirements; any partial or full demolition of a structure, interior or exterior, shall require a demolition permit; 9. that the project shall meet all the requirements of the California Building and Uniform Fire Codes, in effect at time of building permit submittal, as amended by the City of Burlingame; Docusign Envelope ID: B6A9083D-D856-4BBB-8543-E17D19FE111C DSR22-0006 PC/09/08/2025 Page 4 THE FOLLOWING CONDITIONS SHALL BE MET DURING THE BUILDING INSPECTION PROCESS PRIOR TO THE INSPECTIONS NOTED IN EACH CONDITION: 10. that prior to scheduling the framing inspection the applicant shall provide a certification by the project architect or residential designer, or another architect or residential design professional, that demonstrates that the project falls at or below the maximum approved floor area ratio for the property; 11. that prior to scheduling the framing inspection the project architect or residential designer, or another architect or residential design professional, shall provide an architectural certification that the architectural details shown in the approved design which should be evident at framing, such as window locations and bays, are built as shown on the approved plans; architectural certification documenting framing compliance with approved design shall be submitted to the Building Division before the final framing inspection shall be scheduled; 12. that prior to scheduling the roof deck inspection, a licensed surveyor shall shoot the height of the roof ridge and provide certification of that height to the Building Division; and 13. that prior to final inspection, Planning Division staff will inspect and note compliance of the architectural details (trim materials, window type, etc.) to verify that the project has been built according to the approved Planning and Building plans. SECTION 4: The Major Design Review and Hillside Area Construction Permit approval shall be subject to revocation if the applicant fails to comply with the conditions listed herein at any time. If, at any time, the Community Development Director or Planning Commission determine that there has been or may be a violation of the findings or conditions of this approval, or of the Zoning Regulations, a public hearing may be held before the Planning Commission to review this approval pursuant to Zoning Regulation Section 25.88.050. At said hearing, the Planning Commission may add conditions, or recommend enforcement actions, or revoke the approval entirely, as necessary to ensure compliance with the Zoning Regulations, and to provide for the health, safety, and general welfare of the community. PASSED AND ADOPTED this 8th day of September 2025. Chairperson I, _____________ , Secretary of the Planning Commission of the City of Burlingame, do hereby certify that the foregoing resolution was introduced and adopted at a regular meeting of the Planning Commission held on the 8th day of September 2025 by the following vote: Secretary Exhibits: Docusign Envelope ID: B6A9083D-D856-4BBB-8543-E17D19FE111C Walker Shores DSR22-0006 PC/09/08/2025 Page 5 Exhibit A - Project Plans dated July 9, 2025 AYES: HORAN, LOWENTHAL, PFAFF, SHORES NOES: NONE RECUSED: NONE ABSENT: SCHMID, TSE Docusign Envelope ID: B6A9083D-D856-4BBB-8543-E17D19FE111C SHEET: PROJECT LOCATION: SCALE: SHEET INFO: DATE: COVER SHEET 7/9/2025 1812 CASTENADA DR. APN:025091200 SITE ADDRESS: 1812 CASTENADA DR. SITE CITY STATE ZIP: BURLINGAME, CA 94010 EXISTING STORIES:1 PROPOSED STORIES:2 EXISTING UNITS:1 CONSTRUCTION:TYPE VB ZONING:R1 OCCUPANCY:R-3 (SINGLE FAMILY RESIDENTIAL) LOT AREA: 6,699 SQFT EXISTING: GROUND FLOOR AREA: 1,620 SQFT GARAGE: 389 SQFT TOTAL:2,009 SQFT PROPOSED: GROUND FLOOR AREA: 1,800 SQFT SECOND FLOOR: 720 SQFT GARAGE: 389 SQFT TOTAL AREA:2,909 SQFT INDEX: T1.0 COVER SHEET A1.0 BLOCK MAP/ EXISTING SITE PLAN A1.1 PROPOSED SITE PLAN A1.2 LOT COVERAGE AND FAR DIAGRAM A1.3 EXISTING/ PROPOSED ROOF PLANS A2.0 EXISTING/ PROPOSED FIRST FLOOR PLANS A2.1 PROPOSED SECOND FLOOR A3.0 EXISTING/ PROPOSED ELEVATIONS/ SECTION A4.0 EXISTING/ PROPOSED ELEVATIONS A5.0 EXISTING/ PROPOSED ELEVATIONS A6.0 EXISTING/ PROPOSED ELEVATIONS D1.0 DETAILS R1.0 RENDERS PROJECT DESCRIPTION: SECOND STORY ADDITION PAGE: REVISION TABLE #DATE REVISED BY DEPT 1812 CASTENADA DR. BURLINGAME, CA 94010 HOMEOWNER & CONTRACTOR: TO VERIFY ALL DIMENSIONS,STRUCTURAL DETAILS, AND BUILDING CODES. ALL WORKS SHALL COMPLY WITH: 2022 California Building Code 2022 California Electrical Code 2022 California Mechanical Code 2022 California Plumbing Code 2022 California Energy Code ALL WORKS SHALL COMPLY WITH THE CALIFORNIA CODE OF REGULATIONS TITLE 24: 2022Residential Building Code 2022 Green Building Standards Code SCOPE OF WORK: 1.REMODEL (E) KITCHEN 2.INSTALL (N) WINDOWS 3.REMOVE (E) FIREPLACE 4.BUILD SECOND FLOOR ADDITION 5.BUILD SECOND STORY DECK IN REAR OF PROPERTY CONSTRUCTION HOURS: No person shall erect (including excavation and grading), demolish, alter or repair any building or structure other than between the following hours except in the case of urgent necessity in the interest of public health and safety, and then only with prior written approval from the Building Official, which approval shall be granted for a period not to exceed three days. No work on Sundays and Holidays. Holidays are the first day of January, the third Monday of February, the last Monday of May, the fourth day of July, the first Monday of September, the eleventh day of November, the fourth Thursday in November and the twenty-fifth day of December. If the first day of January, the fourth day of July, the eleventh day of November, or the twenty-fifth day of December falls upon a Sunday the following Monday is a holiday. Provide the following construction hours on the plans per City of Burlingame Municipal Code 18.07.110. Monday through Friday:8AM TO 7PM Saturdays:9AM TO 6PM T1.0 REVISED JUL 9, 2025 RECEIVED CITY OF BURLINGAME CDD-PLANNING DIVISION Docusign Envelope ID: B6A9083D-D856-4BBB-8543-E17D19FE111C SSGG15'-8 1/2"20'20'-2 1/2"20'6'-4" 7'-6 1/2"10'FRONT YARD SETBACK REAR YARD SETBACK 7' SIDE YARD SETBACK7' SIDE YARDSETBACKPL 52.0' PL 52.9' TC 50.0' TC 51.2' 8" APRICOT 3" POMELO 10" APRICOT 5" PEACH ROSE BUSH SLOPEC A S T E N A D A D R . SEWERGAS WWATER WWWW2 - (E) TREES, NON-FRUIT AND NON-NUT BEARING PLPL 51.4' PL 50.3' 1812 CASTENADA 74.43'100.0'100.0'58.87' N NSHEET: PROJECT LOCATION: 1/8" = 1'-0" SCALE: A1.0 SHEET INFO: DATE: 2 BLOCK MAP 3 EXISTING SITE PLAN 7/9/2025 SUBJECT PROPERTY 1 NEIGHBORHOOD MAP PROJECT DESCRIPTION: SECOND STORY ADDITION PAGE: REVISION TABLE #DATE REVISED BY DEPT BLOCK MAP/ SITE PLAN 1812 CASTENADA DR. BURLINGAME, CA 94010 Docusign Envelope ID: B6A9083D-D856-4BBB-8543-E17D19FE111C SSSGG15'-8 1/2"20'15'1'-6"10'17'-7"23'-10"2'5'-5"FRONT YARD SETBACK REAR YARD SETBACK SIDE YARDSETBACK7' SIDE YARDSETBACKPROPOSED 2ND STORY ADDITION PL 52.0' PL 52.9' TC 50.0' TC 51.2' 8" APRICOT 3" POMELO 10" APRICOT 5" PEACH ROSE BUSH SLOPEC A S T E N A D A D R . SEWER GAS WWATER WWW(E) TREE - NON-FRUIT AND NON-NUT BEARING PLPL 51.4' PL 50.3' PROPOSED 2ND STORY DECK 1812 CASTENADA PROPOSED 1ST STORY ADDITION 74.43'100.0'100.0'58.87' (N) CRAPE MYRTLE w/ 24" BOX ROW NADDRESS SETBACK EXCLUDE MIN./MAX. 1804 CASTENADA DR.15.5' 1808 CASTENADA DR.16' 1812 CASTENADA DR.15.5'N/A 1820 CASTENADA DR.16' 1826 CASTENADA DR.17' 1830 CASTENADA DR.16' 1834 CASTENADA DR.16.5' 1838 CASTENADA DR.19' 370 CASTENADA DR.20' 360 CASTENADA DR.22' 350 CASTENADA DR.22.5'N/A 340 CASTENADA DR.22' 330 CASTENADA DR.22' 320 CASTENADA DR.21' 320 CASTENADA DR.21' 320 CASTENADA DR.21' 310 CASTENADA DR.15.5' AVERAGE CALC 280.5 / 15 ALLOWABLE SETBACK 18.7 OR 18'-08" CASTENADA DRIVE SETBACK CALCULATION ADDITION EXISTING BUILDING LEGEND SHEET: PROJECT LOCATION: SCALE: SHEET INFO: DATE: 7/9/2025 PROJECT DESCRIPTION: SECOND STORY ADDITION PAGE: REVISION TABLE #DATE REVISED BY DEPT 1812 CASTENADA DR. BURLINGAME, CA 94010 1 PROPOSED SITE PLAN A1.1 SITE PLAN 1/8" = 1'-0" Docusign Envelope ID: B6A9083D-D856-4BBB-8543-E17D19FE111C PROPOSED LOT COVERAGE FOOT PRINT / LOT SIZE (SF) = LOT COVERAGE 2278 / 6699 = 0.34 PROPOSED FAR TOTAL SF / LOT SIZE (SF) = FLOOR AREA RATIO 3066 / 6699 = 0.46 CALCULATIONS N52'-11"63'-8"34'24'19'-11 1/2" COVERED PORCH AREA - 26.5 SF COVERED PORCH AREA - 42 SF 74.43'100.0'100.0'58.87' 74.43'100.0'100.0'58.87' GROUND FLOOR AREA - 2,278 SF SECOND FLOOR AREA -812 SF SHEET: PROJECT LOCATION: SCALE: SHEET INFO: DATE: 7/9/2025 PROJECT DESCRIPTION: SECOND STORY ADDITION PAGE: REVISION TABLE #DATE REVISED BY DEPT 1812 CASTENADA DR. BURLINGAME, CA 94010 1 PROPOSED LOT COVERAGE AND F.A.R. DIAGRAM A1.2 SITE PLAN 1/8" = 1'-0" FIRST FLOOR SECOND FLOOR Docusign Envelope ID: B6A9083D-D856-4BBB-8543-E17D19FE111C N15'-8 1/2"20'20'-2 1/2"20'6'-4" 7'-6"10'FRONT YARD SETBACK REAR YARD SETBACK SIDE YARDSETBACKPL 52.0' PL 52.9' TC 50.0' TC 51.2'SLOPEC A S T E N A D A D R . 4:12 4:12 4:12 PLPL 51.4' PL 50.3' 4:12 4:12 RIDGE PEAK 66.18'' 4:12 4:12 15'-8 1/2"20'15'2'5'-5"FRONT YARD SETBACK REAR YARD SETBACK SIDE YARDSETBACKPL 52.0' PL 52.9' TC 51.2' PLPL 51.4' PL 50.3'SLOPE4:124:12 4:12 4:12 4:12 4:12 4:12 4:124:124:124:124:12(N) TREE RIDGE PEAK 75.09''4:124:12TC 50.0' C A S T E N A D A D R . PL 50.3' (N) CRAPE MYRTLE w/ 24" BOX ROW NSHEET: PROJECT LOCATION: SCALE: SHEET INFO: DATE: 7/9/2025 PROJECT DESCRIPTION: SECOND STORY ADDITION PAGE: REVISION TABLE #DATE REVISED BY DEPT 1812 CASTENADA DR. BURLINGAME, CA 94010 1 EXISTING ROOF PLAN A1.3 SITE PLAN 1/8" = 1'-0" 2 PROPOSED ROOF PLAN Docusign Envelope ID: B6A9083D-D856-4BBB-8543-E17D19FE111C W04W04 W07W07 W06W06 W03W03 W08W08 W05W05 W05W05 W01W01 W02W02 DW20'-6 3/4"2'-1 1/2"11'-7"2'-1 1/2"12'-8"12'-2 1/4"10'-2"3'-4 1/4"4'-11 1/2" 19'-0 3/4" 4'-11 3/4"27'-2 3/4"9'-10 1/4"6'-6"4'-5"3'-6"25'-3 3/4"18'-11"13'-3 1/2"1'-11"5'-6"6'-5"3'-1"7'-7"4'-11 3/4" 37 SQ FT 267 SQ FT 276 SQ FT 389 SQ FT 116 SQ FT 9 SQ FT 21 SQ FT 26 SQ FT 46 SQ FT58 SQ FT27 SQ FT127 SQ FT 16 SQ FT 224 SQ FT 4 SQ FT 77 SQ FT 194 SQ FT (E) FIREPLACE TO BE REMOVED GARAGE BEDROOM BEDROOM HALLLAUNDRY BATH BATH CLOSET CLOSET CLOSET CLOSET BEDROOM CLOSETKITCHEN LIVING DINING ENTRY WINDOW SCHEDULE NUMBER QTY FLOOR WIDTH HEIGHT AREA (SQ FT)DESCRIPTION W01 1 1 70 "34 "16.53 TRIPLE CASEMENT-LHL/RHR W02 1 1 94 "46 "30.03 TRIPLE SLIDING W03 1 1 48 "30 "10.0 LEFT SLIDING W04 1 1 29 "58 "11.68 DOUBLE HUNG W05 2 1 30 "35 "7.29 LEFT SLIDING W06 1 1 69 "40 "19.17 RIGHT SLIDING W07 1 1 93 "40 "25.83 TRIPLE CASEMENT-LHL/RHR W08 1 1 93 "56 "36.17 TRIPLE SLIDING TOTALS:163.99 (E) WALL TO BE REMOVED (N) WALL (E) WALL TO REMAIN LEGEND 1HR - FIRE RATED WALL NND01D01 W04W04 D15D15D05D05 D06D06 D02D02W08W08 W05W05 W05W05 38685072D08D083868 D13D13 D10D10 D12D12 D13D13 D07D07 D13D13 D11D11 D09D09 D11D11 D14D14 D13D13 D14D14 D04D04 W01W01 W07W07 W06W06 D03D03 W03W03 W02W02 UP 2'20'-6 3/4"2'-1 1/2"11'-7"2'-1 1/2"12'-8"12'-2 1/4"10'-2"3'-4 1/4"4'-11 1/2" 19'-0 3/4"25'-3 3/4"19'-7 15/16"12'-4 9/16"1'-11"5'-6"6'-5"3'-1"7'-7"16'-3"2'2'37 SQ FT 349 SQ FT 389 SQ FT 116 SQ FT 9 SQ FT 21 SQ FT 26 SQ FT 46 SQ FT58 SQ FT27 SQ FT127 SQ FT 16 SQ FT 224 SQ FT 4 SQ FT 310 SQ FT GARAGE BEDROOM BEDROOM HALLLAUNDRY BATH BATH CLOSET CLOSET CLOSET CLOSET BEDROOM CLOSETLIVING DINING ROOF OVERHANG (E) WALL TO BE REMOVED (N) WALL (E) WALL TO REMAIN LEGEND 1HR - FIRE RATED WALL (E) WALL TO BE REMOVED (N) WALL (E) WALL TO REMAIN LEGEND 1HR - FIRE RATED WALL SHEET: PROJECT LOCATION: SCALE: SHEET INFO: DATE: 1/4" = 1'-0" A2.0 7/9/2025 PROJECT DESCRIPTION: SECOND STORY ADDITION PAGE: REVISION TABLE #DATE REVISED BY DEPT FLOOR PLANS 1812 CASTENADA DR. BURLINGAME, CA 94010 1 EXISTING GROUND FLOOR PLAN 2 PROPOSED GROUND FLOOR PLAN Docusign Envelope ID: B6A9083D-D856-4BBB-8543-E17D19FE111C DN W13W13 D19D19 W11W11 D17D17 W13W13 W10W10 D18D18 W13W13 W09W09 W14W14 W12W12 D16D16 3'16'21'-9" 12'-6"9'14'-4"10'3'-3 3/4"327 SQ FT 79 SQ FT 46 SQ FT 145 SQ FT 142 SQ FT BEDROOM OFFICE BATH DECK CLOSET DOOR SCHEDULE NUMBER QTY FLR WIDTH HEIGHT DESCRIPTION STATUS D01 1 1 36 "80 "EXT. HINGED-DOOR 1 NEW D02 1 1 36 "80 "EXT. HINGED-DOOR 2 NEW D03 1 1 36 "80 "EXT. HINGED-DOOR 3 NEW D04 1 1 121 "80 "SLIDER-DOOR EXISTING D05 1 1 144 "80 "EXT. QUAD SLIDER-GLASS PANEL NEW D06 1 1 192 "84 "GARAGE-PANEL NEW D07 1 1 18 "80 "HINGED-DOOR EXISTING D08 1 1 24 "80 "HINGED-DOOR NEW D09 1 1 28 "80 "HINGED-DOOR EXISTING D10 1 1 30 "80 "HINGED-DOOR EXISTING D11 2 1 30 "80 "POCKET-DOOR EXISTING D12 1 1 32 "80 "EXT. HINGED-DOOR EXISTING D13 4 1 32 "80 "HINGED-DOOR EXISTING D14 2 1 60 "80 "4 DR. BIFOLD-LOUVERED EXISTING D15 1 1 70 "80 "EXT. SLIDER-GLASS PANEL NEW D16 1 2 36 "80 "HINGED-DOOR NEW D17 1 2 30 "80 "HINGED-DOOR NEW D18 1 2 36 "80 "POCKET-DOOR NEW D19 1 2 72 "80 "EXT. SLIDER-GLASS PANEL NEW WINDOW SCHEDULE NUMBER QTY FLR WIDTH HEIGHT AREA (SQ FT)DESCRIPTION STATUS W01 1 1 90 "40 "25.0 TRIPLE CASEMENT-LHL/RHR NEW W02 1 1 60 "50 "20.83 DOUBLE CASEMENT-LHL/RHR NEW W03 1 1 60 "30 "12.5 DOUBLE CASEMENT-LHL/RHR EXISTING - SAME SIZE W04 1 1 30 "53 "11.04 SINGLE CASEMENT-HL EXISTING - SAME SIZE W05 2 1 30 "35 "7.29 LEFT SLIDING EXISTING - SAME SIZE W06 1 1 69 "40 "19.17 RIGHT SLIDING EXISTING - SAME SIZE W07 1 1 93 "40 "25.83 TRIPLE CASEMENT-LHL/RHR EXISTING - SAME SIZE W08 1 1 93 "56 "36.17 TRIPLE SLIDING EXISTING - SAME SIZE W09 1 2 30 "48 "10.0 SINGLE CASEMENT-HL NEW W10 1 2 60 "46 "19.17 DOUBLE CASEMENT-LHL/RHR NEW W11 1 2 30 "46 "9.58 SINGLE CASEMENT-HR NEW W12 1 2 90 "46 "28.75 TRIPLE CASEMENT-LHL/RHR NEW W13 3 2 30 "46 "9.58 SINGLE CASEMENT-HL NEW W14 1 2 30 "48 "10.0 SINGLE CASEMENT-HR NEW TOTALS:271.36 (E) WALL TO BE REMOVED (N) WALL (E) WALL TO REMAIN LEGEND 1HR - FIRE RATED WALL SHEET: PROJECT LOCATION: SCALE: SHEET INFO: DATE: 7/9/2025 PROJECT DESCRIPTION: SECOND STORY ADDITION PAGE: REVISION TABLE #DATE REVISED BY DEPT 1812 CASTENADA DR. BURLINGAME, CA 94010 A2.1 FLOOR PLANS 1 PROPOSED SECOND FLOOR PLAN 1/4" = 1'-0" 2 PROPOSED WINDOW AND DOOR SCHEDULE Docusign Envelope ID: B6A9083D-D856-4BBB-8543-E17D19FE111C 8'-1 1/2"1 8 1 2 (E) WINDOWS TO BE REMOVED 53'-3" FIRST FL. SUBFL. 52'-3" GARAGE SLAB 50'-7" T.O.C. AVERAGE 62'-4" FIRST FL. CEILING 66'-5" RIDGE 4 12 24'-5"9'8'PLPL52'-2" DEAPRTURE POINT 51'-2" DEAPRTURE POINT 1 8 1 2 8" WOOD CLAPBOARD SIDING - PAINT2X4 WOOD TRIM - SEE DETAIL 2,3/D1.0 2X4 WOOD TRIM - SEE DETAIL 2,3/D1.0 (N) ASPHALT COMPOSITE SHINGLES NEW FIR SIMPSON DOOR - SEE DETAIL 2,3/D1.0 (N) WOOD GARAGE DOOR WITH FROSTED GLASS TO MATCH FRONT DOOR MATERIAL (N) ALUMINUM CLAD WOOD WINDOW (N) ALUMINUM CLAD WOOD WINDOW (N) ALUMINUM CLAD WOOD WINDOW(N) ALUMINUM CLAD WOOD WINDOW 52'-3" GARAGE SLAB 50'-7" T.O.C. AVERAGE 74'-11" RIDGE 53'-3" FIRST FL. SUBFL. 61'-5" FIRST FL. CEILING 62'-3" SECOND FL. SUBFL. 66'-5" E RIDGE 70'-3" SCOND FL. CEILING 4 12 4 12 24'-5"9'8'50'-6" T.O.C. AVERAGE 52'-3" GARAGE SLAB 50'-7" T.O.C. AVERAGE 74'-11" RIDGE 53'-3" FIRST FL. SUBFL. 61'-5" FIRST FL. CEILING 62'-3" SECOND FL. SUBFL. 66'-5" E RIDGE 70'-3" SCOND FL. CEILING SHEET: PROJECT LOCATION: SCALE: SHEET INFO: DATE: 7/9/2025 1/4" = 1'-0" A3.0 PROJECT DESCRIPTION: SECOND STORY ADDITION PAGE: REVISION TABLE #DATE REVISED BY DEPT ELEVATION 1812 CASTENADA DR. BURLINGAME, CA 94010 3 PROPOSED SECTION 1 EXISTING SOUTH (FRONT) ELEVATION 2 PROPOSED SOUTH (FRONT) ELEVATION NUMBERS AND ADDRESSES SHALL BE PLACED ON ALL NEW AND EXISTING BUILDING IN SUCH A POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FRONT THE STREET OR ROAD FRONTING THE PROPERTY. SAID NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND, SHALL BE A MINIMUM OF ONE- HALF INCH STROKE BY FOUR INCHES HIGH, AND SHALL BE EITHER INTERNALLY OR EXTERNALLY ILLUMINATED IN ALL NEW CONSTRUCTION, ALTERATIONS OR REPAIR OF EXISTING CONSTRUCTION. THE POWER OF SUCH ILLUMINATION SHALL NOT BE NORMALLY SWITCHABLE PER CITY OF BURLINGAME MUNICIPAL CODE 18.08.010. 2019 CBC 502.1 4 BUILDING ADDRESS NOTE Docusign Envelope ID: B6A9083D-D856-4BBB-8543-E17D19FE111C 53'-3" FIRST FL. SUBFL. 52'-3" GARAGE SLAB 50'-07" T.O.C. AVERAGE 62'-4" FIRST FL. CEILING 66'-5" RIDGE 4 12 24'-5"9'8'PL50'-6" T.O.C. AVERAGE 51'-2" DEAPRTURE POINT 8" WOOD CLAPBOARD SIDING - PAINT 2X4 WOOD TRIM - SEE DETAIL 2,3/D1.0NEW FIR SIMPSON DOOR - SEE DETAIL 2,3/D1.0 SLIDING DOORS PAINT TO MATCH TRIM PL52'-2" DEAPRTURE POINT 50'-6" T.O.C. AVERAGE 52'-3" GARAGE SLAB 50'-7" T.O.C. AVERAGE 74'-11" RIDGE 53'-3" FIRST FL. SUBFL. 61'-5" FIRST FL. CEILING 62'-3" SECOND FL. SUBFL. 66'-5" E RIDGE 70'-3" SCOND FL. CEILING (N) ASPHALT COMPOSITE SHINGLES SLIDING DOORS PAINT TO MATCH TRIM 42" WOOD RAILING - PAINT TO MATCH TRIM (N) ALUMINUM CLAD WOOD WINDOW - TYP 4 12 4 12 SHEET: PROJECT LOCATION: SCALE: SHEET INFO: DATE: 7/9/2025 1/4" = 1'-0" A4.0 PROJECT DESCRIPTION: SECOND STORY ADDITION PAGE: REVISION TABLE #DATE REVISED BY DEPT ELEVATION 1812 CASTENADA DR. BURLINGAME, CA 94010 1 2 EXISTING NORTH (REAR) ELEVATION PROPOSED NORTH (REAR) ELEVATION Docusign Envelope ID: B6A9083D-D856-4BBB-8543-E17D19FE111C 53'-02" FIRST FL. SUBFL. 52'-3" GARAGE SLAB 50'-7" T.O.C. AVERAGE 53'-3" FIRST FL. SUBFL. 62'-4" FIRST FL. CEILING 66'-5" RIDGE 24'-5"9'8'PLPL8" WOOD CLAPBOARD SIDING - PAINT (N) ALUMINUM CLAD WOOD WINDOW (E) DOOR TO REMAIN (E) WINDOW TO REMAIN (E) WINDOW TO REMAIN (N) ALUMINUM CLAD WOOD WINDOW 50'-6" T.O.C. AVERAGE 52'-3" GARAGE SLAB 50'-7" T.O.C. AVERAGE 74'-11" RIDGE 53'-3" FIRST FL. SUBFL. 61'-5" FIRST FL. CEILING 62'-3" SECOND FL. SUBFL. 66'-5" E RIDGE 70'-3" SCOND FL. CEILING 4 12 4 12 SHEET: PROJECT LOCATION: SCALE: SHEET INFO: DATE: 7/9/2025 PROJECT DESCRIPTION: SECOND STORY ADDITION PAGE: REVISION TABLE #DATE REVISED BY DEPT 1812 CASTENADA DR. BURLINGAME, CA 94010 1/4" = 1'-0" A5.0 ELEVATION 1 2 PROPOSED EAST (LEFT) ELEVATION EXISTING EAST (LEFT) ELEVATION Docusign Envelope ID: B6A9083D-D856-4BBB-8543-E17D19FE111C 24'-5"9'8'PLPL(N) ALUMINUM CLAD WOOD WINDOW (N) ALUMINUM CLAD WOOD WINDOW (E) WINDOW TO REMAIN 8" WOOD CLAPBOARD SIDING - PAINT (N) ALUMINUM CLAD WOOD WINDOW50'-6" T.O.C. AVERAGE 52'-3" GARAGE SLAB 50'-7" T.O.C. AVERAGE 74'-11" RIDGE 53'-3" FIRST FL. SUBFL. 61'-5" FIRST FL. CEILING 62'-3" SECOND FL. SUBFL. 66'-5" E RIDGE 70'-3" SCOND FL. CEILING 4 12 4 12 53'-02" FIRST FL. SUBFL. 52'-02" GARAGE SLAB 50'-06" T.O.C. AVERAGE 53'-02" FIRST FL. SUBFL. 62'-03" FIRST FL. CEILING 66'-04" RIDGE SHEET: PROJECT LOCATION: SCALE: SHEET INFO: DATE: 7/9/2025 PROJECT DESCRIPTION: SECOND STORY ADDITION PAGE: REVISION TABLE #DATE REVISED BY DEPT 1812 CASTENADA DR. BURLINGAME, CA 94010 1/4" = 1'-0" A6.0 ELEVATION 2 PROPOSED WEST (RIGHT) ELEVATION 1 EXISTING WEST (RIGHT) ELEVATION Docusign Envelope ID: B6A9083D-D856-4BBB-8543-E17D19FE111C 2X FRAMING (N) 5/8" GYPSUM BOARD "TYPE X" - BOTH SIDES (N) 5/8" GYPSUM BOARD "TYPE X" ON CEILING (N) 2x6 PT DF (N) 6X10 HEADER (N) ALUMINUM WOOD-CLAD WINDOW - SEE SCHEDULE (N) 2X6 PT DF (N) 2x4 WOOD TRIM - PAINT (N) 2x SILL WITH BEVELED EDGE - PAINT (N) 2x4 WOOD TRIM - PAINT WOOD CLAPBOARD SIDING - PAINT (N) 2x8 WOOD FASCIA BOARD - PAINT (N) K-STYLE ALUMINUM GUTTER - PAINT (N) ASPHALT COMPOSITE SHINGLES (N) 2x4 WOOD TRIM - PAINT (N) 2X SILL WITH BEVELED EDGE - PAINT (N) ALUMINUM WOOD-CLAD WINDOW (N) 2x4 WOOD TRIM - PAINT (N) 2x4 WOOD TRIM W/ MITERED CORNERS - PAINT (N) FIR WOOD DOOR W/ GLASS PANELS AND SQUARE STICKING SHEET: PROJECT LOCATION: SCALE: SHEET INFO: DATE: 1/4" = 1'-0" 7/9/2025 PROJECT DESCRIPTION: SECOND STORY ADDITION PAGE: REVISION TABLE #DATE REVISED BY DEPT DETAILS 1812 CASTENADA DR. BURLINGAME, CA 94010 1 1-HR RATED FIRE WALL 2 FACADE FINISH DETAIL - TYP. D1.0 3 EXTERIOR WINDOW AND DOOR TRIM DETAIL - TYP. Docusign Envelope ID: B6A9083D-D856-4BBB-8543-E17D19FE111C SHEET: PROJECT LOCATION: SCALE: SHEET INFO: DATE: 7/7/2025 PROJECT DESCRIPTION: SECOND STORY ADDITION PAGE: REVISION TABLE #DATE REVISED BY DEPT 1812 CASTENADA DR. BURLINGAME, CA 94010 NO SCALE RENDERS 3 REAR FACADE R1.04REAR FACADE 1 FRONT FACADE 2 FRONT FACADE Docusign Envelope ID: B6A9083D-D856-4BBB-8543-E17D19FE111C