Loading...
HomeMy WebLinkAbout1813 Castenada Drive - Staff Report (2)r' Item #8 City of Burlingame Design Review Study Design Review and Hillside Area Construction Permit Address: 1813 Castenada Drive Meeting Date: 11/08/04 Request: Design review and hillside area construction permit for a first and second story addition. Applicant and Architect: Lincoln Lue APN: 025-051-070 Property Owners: Mark and Amy Liew Lot Area: 15,960 SF General Plan: Low Density Residential Zoning: R-1 Summary: The existing single -story house contains 3,204 SF of floor area (0.20 FAR), and has five bedrooms. An existing 541 SF covered patio at the rear of the house will be removed as part of this project. The applicant is proposing a 557 SF first floor addition at the rear of the house and a new 557 SF second floor directly above it. A new uncovered second floor deck (122 SF) is proposed at the rear of the house. The area under the proposed second floor deck (122 SF) is included in the proposed floor area. With the addition, the floor area will be increasing to 3,799 SF (0.24 FAR) (exempting 100 SF of covered porches and chimneys) where 6,207 SF (0.39 FAR) is the maximum allowed. With this project, there is no increase in the number of bedrooms (5). The existing attached one -car garage (13'-6" x 20') is nonconforming since it does not provide enough parking spaces for a five -bedroom house (two covered and one uncovered required). One uncovered parking space is provided in the driveway (space can be measured to the edge of the sidewalk on an existing house). However, because the number of bedrooms is not increasing, a parking variance is not required for the existing nonconforming parking. All other zoning code requirements have been met. The applicant is requesting the following: Design review and hillside area construction permit for a first and second story addition (C.S. 25.57.010 and 25.61.020). Table 1 - 1813 Castenada Drive Lot Area: 15,960 SF EXISTING PROPOSED ALLOWED/REQ'D SETBACKS Side (right): ........................................................................................................................................................................................................................................................................................................................................................... 7'-6" I 10'-6" 7'-01f Rear (1st flr): 90'-0" i 84'-6" to area below deck 15'-0" (2nd flr): ...................... ................................................................ .............. .......... ................... none ......................... ........................................................................................ 84'-6" to deck i........................................................................................................................ ....................... ........................................................................................ 20'-011 Lot Coverage: 3204 SF 3342 SF 6384 SF ....................................................................................................................................................................................... 20% 20.9% 40% FAR: 3204 SF 3799 SF 6207 SF 0.20 FAR 0.24 FAR 0.39 FAR v Design Review and Hillside Area Construction Permit 1813 Castenada Drive Table 1 - 1813 Castenada Drive Lot Area: 15,960 SF EXISTING ( PROPOSED ALLOWED/REQ'D # of bedrooms: 5 5 I --- .......................................................................... ...... _.... . _. _........._................................................................................. ....... _. _... _......... _...-- .. Parking: 1 covered 1 no change 2 covered (13'-9" x 20') 1 uncovered 1 uncovered ................................. _...... _... .._... _..... __......... _.._...... _.._..._................... (9' x 20') _..._.---........ ... _. .. ' 3 Height: ..................... _... _.... _--_...._.............. .................................... ........... 19'-6" __...... _.... _.._._........................................................... ............................................._ 27'-1 " .... ...... _................................. _......... _........................................... ........._...... _.............. _... _i�......._ 3 0'-0" ...... _... --._.... _.............................................................................. _... _.._.._...._.._ ._...._DHEnvelope: n/a ...... .......................... _........_complies ........................................ _.... I -__._.._._.._.... Hillside Area n/a _.._...... -- required2 ............. __see...code..............___.__.......... __........ see code Permit: ' Existing nonconforming parking (one covered space existing where two covered space are required for a five bedroom house). No change in the number of bedrooms (5) is proposed. 2 Hillside area construction permit for a first and second story addition (C.S. 25.61.020). Staff Comments: See attached. Ruben Hurin Planner c. Lincoln Lue, applicant and architect 2