HomeMy WebLinkAboutStaff Report� d { �! _' �'C! CITY OF B URLINGAME VARIANCE Variance for Side Setback Address: 1568 Alturas Drive Item # 1 Meeting Date: June 10, 1996 Request: Side setback variance for a deck and hot tub with a 2'-0" side setback where 7'-0" is required (C.S. 25.28.072, 3a) at 1568 Alturas Drive, zoned R-1. Applicant: Steven B. Groubert Property Owner: Same APN: 027-021-290 Lot Dimensions and Area: 99' X 122' = 12,078 SF General Plan: Single family residential Zoning: R-1 Adjacent Development: Single family residential and Mills Canyon CEQA Status: Article 19. Categorically Exempt per Section: 15301 - Class 1(e): Existing facilities- additions to existing structures provided that the addition will not result in an increase of more that 505 of the floor area of the structure before the addition. Summary: The applicant is requesting a side setback variance to build a deck and hot tub within 2'-0" of the side property line at 1568 Alturas Drive. The project includes extending the master bedroom and adding a master bath and deck. The deck is a second floor deck along the back of the house and drops down to a proposed hot tub area. It is the proposed hot tub area of the deck along the north west side property line which creates the need for a variance. The required side setback for a lot 99'-0" wide is 7'-0", where two 2'-0" is proposed. The portion of the deck which is within 2'-0" of side property line is 13'-0" long and the remainder of the proposed deck is setback 9'-0" or more from the side property line. This lot slopes steeply from the back of the house to the rear property line. The deck is 9'-6" above the grade at its highest point and at grade at its lowest. All other zoning code requirements are met. Front Stbk (lst): (2nd): Side Stbk (L): * Side Stbk (R): Rear Stbk (lst): (2nd) : Lot Coverage: FAR: Height: Decl. At.: Parking: PROPOSED +31'-0 Not applicable 2'-0" Not applicable 50'-0" 50'-0" 20 % Not applicable 17.5' complies 2 covered 1 uncovererl EXISTING 25'-0" 17'-0" 50'-0" 50'-0" 13% 16' 2 covered 1 uncovered 1 ALLOWED/REQ'D 15'-0" 7'-0" 15'-0" 20'-0" 40 % 20'-0" 1 covered 1 uncovered VARIANCE Meets all other zoning code requirements. * Variance for 2'-0" side setback where 7'-0" is required. 1568 ALTURAS DR. Staff comments: The Chief Building Official stated in his May 20, 1996 memo that Engineering design will be required for post-supported addition and the 9" spaced plastic coated cables may create a strangling problem for small children. The City Engineer and the Fire Marshal had no comments on this project. 2