The City of Burlingame
CIT'1' HALL 501 PRIMROSE ROAD TEL: (650) 558-7250
PLANNING DEPARTMENT BURLINGAME, CALIFORNIA 94010-3997 FAX: (650) 696-3790
July 8, 2005
James Chu
Chu Design & Engr., Inc.
39 W. 43rd Avenue
San Mateo, CA 94403
Dear Mr. Chu,
Since there was no appeal to or suspension by the City Council, the June 27, 2005, Planning Commission
approval of your application for conditional use permit for re-emerging lots, design review and special permit for
declining height envelope became effective July 7, 2005. This application was to allow for construction of a new
two-story single family dwelling and detached garage at 1480 Vancouver Avenue — Lot 39, zoned R-1.
The June 27, 2005, minutes of the Planning Commission state your application was approved with the following
conditions:
that the project shall be built as shown on the plans submitted to the Planning Department date stamped
Apri129, 2005, sheets A.1, A.2, A.S, and L 1.OB, date stamped May 26, 2005, sheet A.6, and date stamped
June 15, 2005, sheets A.3 and A.4, and that any changes to building materials, exterior finishes, footprint
or floor area of the building shall require an amendment to this permit;
2. that any changes to the size or envelope of the basement, first or second floors, or garage, which would
include adding or enlarging a dormer(s), moving or changing windows and architectural features or
changing the roof height or pitch, shall be subject to Planning Commission review;
3. that the tree protection measures for the protected-sized trees and street trees described in the arborist
report, dated April 11, 2005, shall be installed and inspected by the City Arborist before issuance of a
demolition permit and shall be complied with during construction, and that the property owner shall
maintain the trees after construction as directed by the arborist report;
4. that since a tree removal permit for the forty-six inch Cedar (Deodar) tree at the rear of Lot 39 has been
denied, the applicant shall have an arborist's report prepared detailing tree protection measures to be
implemented before, during and after construction to be approved by the City Arborist; the tree protection
measures shall be installed prior to issuance of a demolition permit; and that the landscape plan shall be
: Register online for the City of Burlingame list serve at www.burlin�ame.or� il
�: _,i
July 8, 2005
1480 Vancouver Avenue — Lot 39
page 2 .
revised to relocate the concrete patio away from the root zone of the tree to a location approved by the
City Arborist prior to issuance of a building permit;
5. that prior to scheduling the framing inspection, the project architect, engineer or other licensed
professional shall provide architectural certification that the architectural details such as window
locations and bays are built as shown on the approved plans; if there is no licensed professional involved
in the project, the property owner or contractor shall provide the certification under penalty of perjury.
Certifications shall be submitted to the Building Department;
6. that prior to final inspection, Planning Department staff will inspect and note compliance of the
architectural details (trim materials, window type, etc.) to verify that the project has been built according
to the approved Planning and Building plans;
7. that prior to scheduling the roof deck inspection, a licensed surveyor shall shoot the height of the roof
ridge and provide certification of that height to the Building Department;
8. that all air ducts, plumbing vents, and flues shall be combined, where possible, to a single termination
and installed on the portions of the roof not visible from the street; and that these venting details shall be
included and approved in the construction plans before a Building permit is issued;
9. that the conditions of the City Engineer's, Fire Marshal's and NPDES Coordinator's May 2, 2005, memos,
the Chief Building Official's April 29, 2005, memo, the Recycling Specialist's May 16, 2005, memo, and
the City Arborist's June 15, 2005, memo, shall be met;
10. that the proj ect shall meet all the requirements of the California Building and Uniform Fire Codes, 2001
Edition, as amended by the City of Burlingame;
11. that the project shall comply with the Construction and Demolition Debris Recycling Ordinance which
requires affected demolition, new construction and alteration projects to submit a Waste Reduction plan
and meet recycling requirements; any partial or full demolition of a structure, interior or exterior, shall
require a demolition permit;
12. that the applicant shall comply with Ordinance 1503, the City of Burlingame Storm Water Management
and Discharge Control Ordinance;
13. that prior to scheduling the foundation inspection a licensed surveyor shall locate the property corners and
set the building footprint;
14. that prior to underfloor frame inspection the surveyor shall certify the first floor elevation of the new
structure(s) and the various surveys shall be accepted by the City Engineer;
15. that during demolition of the existing residence, site preparation and construction of the new residence,
the applicant shall use all applicable "best management practices" as identified in Burlingame's Storm
Water Ordinance, to prevent erosion and off-site sedimentation of storm water runoff;
�----��
July 8, 2005
1480 Vancouver Avenue — Lot 39
page 3
16. that the project is subject to the state-mandated water conservation program, and a complete Irrigation
Water Management Plan must be submitted with landscape and irrigation plans at time of permit
application;
17. that demolition for removal of the existing structures and any grading or earth moving on the site shall
not occur until a building permit has been issued and such site work shall be required to comply with all
the regulations of the Bay Area Air Quality Management District;
18. that during demolition of the existing residence, site preparation and construction of the new residence,
the applicant shall use all applicable "best management practices" as identified in Burlingame's Storm
Water Ordinance, to prevent erosion and off-site sedimentation of storm water runoff;
19. that off-site runoff shall be diverted around the construction site and all on-site runoff shall be diverted
around exposed construction areas;
20. that fiber rolls and other erosion prevention products are installed around the construction site as a barrier
to prevent erosion and construction runoff into the storm drain;
21. that oils, fuels, solvents, coolants and other chemicals stored outdoors shall be protected from drainage by
structures such as berms and roof covers; bulk materials stored outdoors shall be protected from drainage
with berms and covers; equipment stored outdoors shall be stored on impermeable surfaces, shall be
covered and shall be inspected for property functioning and leaks; all storage areas shall be regularly
cleaned, including sweeping, litter control and a spill cleanup plan; and
22. that landscape areas shall be designed to reduce excess irrigation run-off, promote surface filtration and
minimize the use of fertilizers, herbicides and pesticides.
Reimbursement of your design review deposit has been processed and will be mailed to the property owner under
separate cover.
All site improvements and construction work will require separate application to the Building Department. This
approval is valid for one year during which time a building permit must be issued. One extension of up to one
year may be considered by the Planning Commission if application is made before the end of the first year.
The decision of the Council is a final administrative decision pursuant to Code of Civil Procedure Section
1094.6. If you wish to challenge the decision in a court of competent jurisdiction, you must do so within 90 days
of the date of the decision unless a shorter time is required pursuant to state or federal law.
Sincerely yours,
l5`t_
M garet Monroe
City Planner
July 8, 2005
1480 Vancouver Avenue — Lot 39
page 4
1480 vanc lot 39.cca
c. Robert and Cynthia Gilson, property owners
30 Woodgate Court
Hillsborough, CA 94010
Chief Building Inspector
Chief Deputy Valuation, Assessor's Office
(LOT 39 BLK 45 EASTON ADD BURLINGAME NO 4 RSM A/45; APN: 026-044-210)
Project Comments
Date:
To:
From:
04/29/2005
d City Engineer
❑ Chief Building Official
❑ Recycling Specialist
❑ Fire Marshal
❑ City Arborist
❑ City Attorney
Planning Staff
Subject: Request for conditional use permit for emerging lots, design review
for a new single family dwelling and detached garage, and special
permit for declining height envelope at 1480 Vancouver Avenue
(LOT 39) , zoned R-1, APN: 026-044-210
Staff Review: 05/02/2005
1. See attached.
2. Sewer backwater protection certification is required. Contact Public Wor{cs —
Engineering Division at (650) 558-7230 for additional information.
Reviewed by: V V
a NPDES Coordinator
Date: 5/02/2005
v � e
PUBLIC WORKS DEPARTMENT ENGINEERING DIVISION
PLANIVING REVIEW COMII�NTS N�► �.�t.� �+w(
. Project Name:��l�i�,,����,
-Project Address:_�b �;����.�,
The following requirements apply to the project
1� L� A property boundary survey shall be preformed by a licensed land .
surveyor. The survey shall show a11 property lines, property corners,
easements, topographical features and utilities. (Required prior to the
building pertnit issuance.) �,,,y�,� � � � � � �� �o ��
2 � The site and roof drainage shall be shown on plans and should be made to
drain towards the Frontage Street. (Required prior to the building pernut
issuance.)
3. The applicant shall submit project grading and drainage plans for
approval prior to the issuance of a Building pemut.
4 The project site is in a flood zone, the project shall comply with the City's
flood zone requirements.
5 � A sanitary sewer lateral t� is required for the project in accordance with
the City's standards. (Required prior to the building permit issuance.)
6. The project plans shall show the required Bayfront Bike/Pedestrian trail
and necessary public access improvements as required by San Francisco
Bay Conservation and Development Commission.
7. Sanitary sewer analysis is required for the project. The sewer analysis
shall identify the projecYs impact to the City's sewer system and any
sewer pump stations and identify mitigation measures.
8 Submit traffic trip generation analysis for the project.
9. Submit a traf�ic impact study for the project. The tr�c study should
identify the project generated impacts- and recommend mitigation
measures to be adopted by the project to be approved by the City
Engineer.
10. The project shall file a pazcel map with the Public Works Engineering
Division. The parcel map shall show all existing property lines, easements,
monuments, and new pmperty and lot lines proposed by the map.
Page 1 of 3
U:lprivate development\PLANNING REVIEW COr�IIVIENTS.doc
. PUBLIC WORKS DEPARTMENT ENGIlVEERING DIVISION
I1. A latest preliminary title report of the subject parcel of land shall be
submitted to the Public Works Engineering Division with the pazcel map
for reviews.
12, Map closure/lot closure calculations sha11 be submitted with the parcel
map.
13 The project shall submit a condominium map to the Engineering Divisions
in accordance with the requirements of the Subdivision Map Act.
14 �_ The project shall, at its own cost, design and conslruct frontage public
improvements. including curb, gutter, sidewalk and other necessary
appurtenant work.
15 The project shall, at its own cost, design and construct frontage streetscape
improvements including sidewalk, curb, gutters, parking meters and poles,
trees, and streedights in accordance with streetscape master plan.
16 By the preliminary review of plans, it appears that the project may cause
adverse impacts during construction to vehiculaz tra�c, pedestrian traffc
and public on street pazking. The project shall identify these impacts and
provide mitigation measure acceptable to the City.
17 The project shall submit hydrologic calculations &om a registered civil
engineer for the proposed creek enclosure. The hydraulie calculations
must show that the proposed creek enclosure doesn't cause any adverse
impact to both upstream and downstream properties. The hydrologic
calculations shall accompany a site map showing the area of the 100-yeaz
flood and existing improvements with proposed improvements.
18 Any work within the drainage azea, creek, or creek banks requires a State
Deparhnent of Fish and Game Permit and Army Corps of Engineers
Pernuts.
19 No conshuction debris shall be allowed into the creek.
20 _� The project shall comply with the City's NPDES pernut requirement to
prevent storm water pollution.
21 The project does not show the dimensions of eacisting driveways, re-
submit plans with driveway, dimensions. Also clarify if the project is
proposing to widen the driveway. Any widening of the driveway is subject
to City Engineer's approval.
22 The plans do not indicate the slope of the driveway, re-submit plans
showing the driveway profile with elevations
Page 2 of 3
U:�private development�PLANNING REVIEW COMMEIdTTS.doc
', . .
' PUBLIC WORKS DEPARTMENT ENGINEERING DIVISION
23 � The back of the driveway/sidewalk approach shall be at least 12" above
the flow line of the frontage curb in the street to prevent overflow of storm
water from the street into private property.
24. For the takeout service, a gazbage receptacle shall be placed in fron� The
� sidewalk fronting the store shall be kept clean 20' from each side of the
ProPert3'•
25. For commercial projects a designated garbage bin space and cleaning area
shall be located inside the building. A drain connecting the garbage area to
the Sanitary Sewer System is required.
Page 3 of 3
U:�private development�FLANNING REVIEW COMMENTS.doc
Project Comments
Date:
04/29/2005
To: ❑ City Engineer
❑ Chief Building Official
❑ City Arborist
❑ City Attorney
From: Planning Staff
❑ Recycling Specialist
d Fire Marshal
❑ NPDES Coordinator
�ubject: Request for conditional use permit for emerging lots, design review
for a new single family dwelling and detached garage, and special
permit for declining height envelope at 1480 Vancouver Avenue
(LOT 39) , zoned R-1, APN: 026-044-210
Staff Review: 05/02/2005
1. Provide a minimum 1 inch water meter.
2. Provide double backflow prevention.
Reviewed by: � /z Date: Z
Project Comments
Date:
To:
From:
04/29/2005
� City Engineer
� Chief Building Official
� City Arborist
� City Attorney
Planning Staff
� Recycling Specialist
� Fire Marshal
✓ NPDES Coordinator
Subject: Request for conditional use permit for emerging lots, design review
for a new single family dwelling and detached garage, and special
permit for declining height envelope at 1480 Vancouver Avenue
(LOT 39) , zoned R-1, APN: 026-044-210
Staff Review: 05/02/2005
Any construction project in the City, regardless of size, shall comply with the City
NPDES permit requirement to prevent stormwater pollution including but not limited
to ensuring that all contractors implement construction Best Management Practices
(BMPs) and erosion and sediment control measures during ALL phases of the
construction project (including demolition).
Ensure that sufficient amount of erosion and sediment control measures are
available on site at all times.
The public right of way/easement shall not be used as a construction staging and/or
storage area and shall be free of construction debris at all times.
Brochures and literatures on stormwater pollution prevention and BMPs are available
for your review at the Planning and Building departments. Distribute to all project
proponents.
For additional assistance, contact Eva J. at 650/342-3727.
Reviewed by: �
Date: 05/02/05
, � .
Project Comments
04/29/2005
Date:
To:
a City Engineer
X Chief Building Official
❑ City Arborist
❑ City Attomey
Planning Staff
From:
O Recycling Specialist
O Fire Marshal
❑ NPDES Coordinator
Subject: Request for conditional use permit for emerging lots, design review
for a new single family dwelling and detached garage, and special
permit for declining height envelope at 1480 Vancouver Avenue
(LOT 39) , zoned R-1, APN: 026-044-210
Staff Review: 05/02/2005
1) All construction must comply with the 2001 Califomia Building Codes (CBC),
the Burlingame Municipal and Zoning Codes, and all other State and Federal
requirements.
2) Provide fully dimensioned plans.
3) Prior to applying for a Building Permit the applicant must either confirm that
the address is 1480 Vancouver Avenue or obtain a change of address from
the Engineering Department. Note: The correct address must be referenced
on all pages of the plans.
4) Obtain a survey of the property lines for any structure within one foot of the
property line.
5) Roof eaves must not project within finro feet of the property line.
6) Exterior bearing wafls less than three feet from the property line must be
constructed of one-hour fire-rated construction and no openings are allowed.
7) Rooms that can be used for sleeping purposes must have at least one window
or door that complies with the egress requirements.
8) Provide guardrails at all landings.
9) Provide handrails at aH stairs where there are more than two risers.
10)Provide lighting at all exterior landings.
11)The fireplace chimney must terminate at least two feet above any roof surface
within ten feet.
Reviewed by: r�
1 //
Date: ���/�. �
• ,�� .
Project Comments
Date:
To:
From:
04/29/2005
� City Engineer
� Chief Building Official
� City Arborist
� City Attorney
X Recycling Specialist
� Fire Marshal
� NPDES Coordinator
Planning Staff
Subject: Request for conditional use permit for emerging lots, design review
for a new single family dwelling and detached garage, and special
permit for declining �height envelope at 1480 Vancouver Avenue
(LOT 39) , zoned R-1, APN: 026-044-210
Staff Review: 05/02/2005
Applicant shall submit a Recycling and Waste Reduction Plan for approval, and
pay a recycling deposit for this and all covered projects prior to demolition,
construction or permitting.
�
IReviewed by:
Date:
����/05