Loading...
HomeMy WebLinkAbout821 Cowan Road - Staff ReportCity of Burlingame Condominium Conversion Permit, Conditional Use Permit for Existing Office/Warehouse Building and Tentative Condominium Map Address: 821 Cowan Road Item #l0a & lOb Action Item Meeting Date: 4/24/06 Request: Condominium conversion permit, conditional use permit and tentative condominium map to convert a five-unit, 25,377 SF office/warehouse building (currently under construction for a first floor remodel and second floor addition) to five office/warehouse condominium units. Property Owner: Konstantinos Dokos Applicant: One Stop Design, Inc. Engineer: Dominguez Associates APN: 024-401-560 Zoning: IB Lot Area: 42,300 SF (0.97 Acres) General Plan: Commercial Uses — Office Use Inner Bayshore Area — Office and Warehouse Uses (Burlingame Bayfront Specific Plan and Design Guidelines) CEQA Status: Mitigated Negative Declaration No. ND 536-P and Addendum Adjacent Development: Office, office/waxehouse and auto rental parking Current Use: Two-story office/warehouse building addition under construction Proposed Use: Conversion of existing building to office/warehouse condominium building Allowable Use: Office/warehouse condominium with condominium conversion permit History: On February 28, 2005, the Planning Commission approved an application for a mitigated negative declaration, conditional use permits, parking and side setback variances to allow for a first floor remodel and second floor addition to an existing office warehouse building at 821 Cowan Road, zoned O-M (since this action the zoning has been changed to IB — Inner Bayshore) (February 28, 2005, P.C. Minutes). At that time, the project was also reviewed for compliance with the Design Guidelines of the Bayfront Specific Plan. The following applications were approved: � Mitigated negative declaration (required for this project because the proposed addition to the existing office/warehouse building exceeds 10,000 SF (11,825 SF proposed) and therefore does not qualify for an exemption); � Conditional use permits to exceed the Specific Area Plan land use density (0.6 FAR for warehouse where 0.5 is allowed) and to vary from the design guidelines for Bayfront Development (CS 25.43.030, 1); � Parking variance for the aisle width at the north and south ends of the parking lot (12'-0" and 13'-6" proposed where 18'-0" is the minimum required for traffic moving in two directions) (CS 25.70.025,1, fl; and � Side setback variance along the left side property line (as measured to new architectural coluxnn features on iirst and second floors) (9'-3 existing, 8'-3" proposed, where 10'-0" is the minimum required) (CS 25.43.055, 3). The proj ect approved by the Commission in February, 2005, included remodeling the existing first floor (13,552 SF) and adding a new second story (11,825 SF). The approved 25,377 SF office/warehouse building contains 13,552 SF of warehouse space on the first floor and 11,825 SF of office space on the second floor in a total of five office/warehouse units. The project also included improvements to the exterior of the building, including stucco walls on the exterior, new vinyl windows throughout the building, and a new pitched s-tile roof. In addition, uncovered decks with wrought iron railing were approved on the second floor at the front and rear ofthe building. Condominium Conversion Permit, Conditional Use Permit and Tentative Condominium Map 821 Cowan Road A building permit was issued on September 23, 2005, and construction is underway. The proj ect being built will be in compliance with building code requirements in effect at the time the permit was issued. The property owner is now applying to convert the five office/warehouse spaces to condominium units. Project Summary: The property owner has submitted an application for a condominium conversion permit to convert an existing five-unit, 25,377 SF office/warehouse building to five condominium units. An application for a condominium conversion permit is allowed for an office/warehouse building if it contains at least 20,000 SF of building area (existing building contains 25,377 SF) (CS 26.32.025). An application for a condominium conversion permit is evaluated and processed pursuant to the procedural requirements set forth for conditional use permits (CS 26.32.020). With this application, there are no changes proposed to the February, 2005 approved project, with the exception of converting the office/warehouse units to condominiums. The February, 2005 project was approved when the O-M District Regulations were in effect. At that time, the Design Guidelines of the Bayfront Specific Plan had been adopted so the project was reviewed for compliance with those standards. Conditional use permits were granted to exceed the Specific Area Plan land use density (0.6 FAR for warehouse where 0.5 is allowed) and to vary from the design guidelines for Bayfront Development (refer to attachment - Compliance with Bayfront Design Guidelines — Inner Bayshore Area). Since the project was approved, the new IB District Regulations were adopted. Therefore, with this application for a condominium conversion, the project must comply with the IB District Regulations. The proposed project complies with the standards in the IB zone with the exception of floor area (see below). The following applications are required for the proposed condominium conversion: Condominium conversion permit to convert a five-unit, 25,377 SF office/warehouse building (currently under construction for a first floor remodel and second floor addition) to five office/warehouse condominium units (CS 026.32.020); and � Conditional use permit to exceed the maximum floor area (0.60 FAR (25,377 SF) proposed where 0.50 FAR (21,150 SF) is the maximum allowed) (CS 25.43.030). In a letter dated February 24, 2006, the property owner notes that initially his intent and cost estimates were based on leasing the office/warehouse units. However, because of current market rental conditions and cost overruns of the proj ect (increase in cost of materials and labor), the property owner has decided it would be best to convert the units to individual office/warehouse condominiums. Each of the five units will contain warehouse space on the first floor and associated office space on the second floor. Units range in size from 3,611 SF to 4,593 SF (office and warehouse). Please refer to Table 2 on pages 4 and 5 for a breakdown of office/warehouse space for each unit. Units 1,2,4 and 5 have access to 273 SF balconies on the second floor. However, there is no requirement to provide private open space or common open space for an office/warehouse condominium. Chapter 26.32, Condominium Conversion Permits, which includes application requirements and minimum requirements, is included in the staff report for reference. Draft declaration of the covenants, conditions and restrictions (CC&R's), specific information concerning the demographic characteristics of the project and a physical elements report are required as part of this application submittal. The physical elements report and demographic chaxacteristics report, submitted by the applicant and date stamped December 27, 2005, is included in the staff report for reference. Planning staff would note that the City Attorney reviewed the draft CC&R's and has accepted them with one minor suggestion to change the wording in the Animals section from "guide dogs" to "service dogs" since it is a protected right under the Americans with Disabilities Act (see attached memo from Larry Anderson, City Attorney, dated February 3, 2006). 2 Condominium Conversion Permit, Conditional Use Permit and Tentative Condominium Map 821 Cowan Road Parking: The two-story office/warehouse building currently under construction was approved with 53 on-site parking spaces (43 standard, 8 compact and 2 disabled-accessible spaces) where 53 are required, including disabled-accessible parking. The approved parking configuration provides a 24'-0" clear back-up space for all parking spaces. A parking variance was approved for the aisle width at the north and south ends of the parking lot (12'-0" and 13'-6" provided where 18'-0" is the minimum required for traffic moving in two directions). The approved paxking lot layout requires traffic to travel in a counter clockwise direction through the parking area. The City's traffic engineer reviewed the on-site traffic circulation and accepted the design. A shared access driveway exists between this property and 837 Cowan Road (property to the south). Landscaping: There are no on-site landscaping requirements for an office/warehouse condominium conversion. However, the February, 2005, project was approved with on-site landscaping to comply with the O-M zoning district regulations in effect at that time. The proj ect will provide 15.9% (6,750 SF) on-site landscaping where 15% (6,345 SF) is the minimum required. Although front setback landscaping was not required, Planning staff would note that 90% (3,300 SF) of the front setback is landscaped (including walkways). The Landscape Plan (sheet L.1) provides details on the proposed plantings throughout the site. Two of the three existing sycamore trees (10 and 12 inches in diameter) at the front of the site will remain. The third existing Sycamore tree (12-inch diameter) will be removed to accommodate a 7'-0" wide sidewalk. The existing Sycamore tree to be removed will be replaced with two, new 24-inch box size Sycamore trees at the front of the site. The applicant notes the vines to grow on the walls of the building will be incorporated in the final landscape design, but this landscape feature is not shown on the landscape plan. Staff Comments: See attached. A tentative condominium map has been submitted in order to create the parcel for the condominiums. The tentative and fmal parcel map is being processed concurrently with the planning application. Table 1 below provides a comparison of the proj ect to the IB District development standards. Table 2 on pages 4 and 5 provides a comparison of the proj ect to the condominium conversion requirements for an office/warehouse building. Table 1 Lot Area: 42,300 SF Com liance with IB Re ulations Proposed i Allowed/Required FZoor Area Ratio: 0.601 �' 0.50 25,377 SF � 21,150 SF _._:.. ::.....:. .....:::. .:.:::. ..._�::.. ...:::.� W.:.... ......... .:.....� ...�__��: ._.::::._ ..�_.��. � _yW___ .:...:.: �.......: .._ .....: :::.... Setbacks Front. 19'-4" � � 10'-0" Left Side: 8'-3 "2 � 10'-0" Right Side: 16'-0" j 10'-0" Rear: 66'-2" � none ......�_...�............_.__�.�»_�._..___. ._._.___._......__...__ _.�_�.��_ _._.._ Parking: 53 spaces ' S3 spaces (43 standard) � (8 compact) (8 compact) f 1:300 SF office (2 disabled-accessible) � 1:1000 SF warehouse 1 Conditional use permit to exceed the maximum floor area (0.60 FAR (25,377 SF) proposed where 0.50 FAR (21,150 SF) is the maximum allowed) (CS 25.43.030). 2 Side setback variance approved in February, 2005 (8'-3" proposed where 10'-0" is required). 3 Condominium Conversion Permit, Conditional Use Permit and Tentative Condominium Map 821 Cowan Road Table 1 (cont'd) Lot Area: 42,300 SF Com liance with IB Re ulations Proposed Allowed/Required , Aisle Width: 12'-0" and 13'-6"3 18'-0" Building Height: 32'-4" 35'-0" Front Setback Landscaping: 90% 60% (3300 SF) (2200 SF) 3 Parking variance approved in February, 2005, for the aisle width at the north and south ends of the parking lot (12'-0" and 13'-6" proposed where 18'-0" is the minimum required for traffic moving in two directions). Table 2 Com liance with Condominium Conversion Re uirements Proposed Allowed/Required Unit Size: Unit 1: 2118 SF office �a 2475 SF warehouse 4593 SF total Unit 2: 1879 SF office � 2637 SF warehouse 4516 SF total Unit 3: 1717 SF office 1894 SF warehouse 3611 SF total Unit 4: 1740 SF office 2637 SF warehouse 4377 SF total I Unit 5: 2121 SF office 2447 SF warehouse 4568 SF total Parking: 53 spaces 53 spaces (43 standard, 8 compact, 2 disabled (8 compact) accessible) ADA Parking: 2 disabled accessible spaces 2 disabled accessible spaces Right Side Setback: 16'-0" 10'-0" Left Side Setback: 8'-3"' 10'-0" 1 Side setback variance approved in February, 2005 (8'-3" proposed where 10'-0" is required). 0 Condominium Conversion Permit, Conditional Use Permit and Tentative Condominium Map Table 2 (cont'd) Comuliance with Condominium Conversion Reauirements Proposed Front Setback Landscaping: 90% 3,300 SF (including walkways) Private Open Space: Common Open Space: 273 SF in Units 1,2,4 and 5 outdoor seating area at main entrance to building 821 Cowan Road Allowed/Required none required none required none required Study Meeting: At the March 27, 2006, Planning Commission study meeting, the Commission had several questions for the applicant (March 27, 2006 P.C. Minutes). The applicant submitted a revised Site Plan and Landscape Plan (sheets T.1 and L.1) and a response letter, dated April 13, 2006, in response the Commission's concerns: Listed below are the Commissions' suggestions and responses by the applicant. 1. Sidewalks at the front of the site along the public right-of-way shall be 8 feet wide with improvements consistent with the Bayfront Design guidelines for the Inner Bayshore area, to be installed by theproperty owner. The Planning Commission requested that the sidewalk width at the front of the site be 8 feet wide. This width was based on information provided at the study meeting that the existing sidewalk width is 8 feet wide. However, Planning staff verified in the field that the existing sidewalk width is actually 5 feet. The bayfront design guidelines for the Inner Bayshore Area recommend a sidewalk width of at least 6 feet. Therefore, Planning staff determined that a sidewalk width of 7 feet at this location would be appropriate. The revised plans, date stamped April 13, 2006, note a new 7 foot wide sidewalk to be installed. Two of the three existing sycamore trees (10 and 12 inches in diameter) at the front of the site will remain. The third existing Sycamore tree (12-inch diameter), located on the front property line, will be removed to accommodate the new 7 foot wide sidewalk. The existing Sycamore tree to be removed is not protected size and will be replaced with two, new 24-inch box size Sycamore trees at the front of the site, as recommended by the City Arborist. A tree removal permit is not required for removal of the existing Sycamore tree. The City Arborist noted that in this case because of the commercial area it is more appropriate to remove the existing Sycamore tree rather than curve the sidewalk around the tree, as is frequently done in residential areas. 2. Provide information on how the on-site parking spaces will be allocated among the ownerships. In his letter dated April 13, 2006, the applicant notes that on-site parking will be allocated per tenant requirements as units are purchased. The process of assigning parking spaces to condominium units will be managed by the Owner's Association, as specified in the CC&R's (Article 2— Property Rights and Easements, Section 2.10 — Exclusive Use Common Area, Draft CC&R's included in staff report). 5 Condominium Conversion Permit, Conditional Use Permit and Tentative Condominium Map 821 Cowan Road 3. Provide information on how the property and landscaping will be maintained among the ownerships. • In his letter dated Apri113, 2006, the applicant notes that the property and landscaping will be maintained by the Owner's Association, as specified in the CC&R's (Article 4— Maintenance and Repair Obligations, Draft CC&R's included in staff report). Issues to Address for a Condominium Conversion: For a condominium conversion the code requires the following issues be addressed at the public hearing (CS 26.32.100): (a) The opinions of the tenants of the project as to whether the proposed conversion protects their interests; (b) Whether or not the amount and impact of the displacement of tenants, if the conversion is approved, would be detrimental to the health, safety or general welfare of the community; (c) The role that the commercial, industrial, office or apartment structure plays in the existing rental market for that use and whether this role is substantially altered by the proposed conversion in the light of the tenant protection provisions in this code. Particular emphasis should be placed on the evaluation of rental structures to determine if the existing building is serving low and moderate income tenants, or special groups of tenants such as elderly or handicapped; (d) If applicable, whether or not lower cost home ownership opportunities will be increased by the conversion of apartments to condominiums, stock cooperatives or community apartments; and (e) Whether tenants will have substantial difficulty in obtaining comparably priced facilities. Findings for a Conditional Use Permit: In order to grant a condominium conversion permit (pursuant to the procedural requirements set forth for conditional use permits), the Planning Commission must find that the following conditions exist on the property (Code Section 25.52.020 a-c): (a) the proposed use, at the proposed location, will not be detrimental or injurious to properiy or improvements in the vicinity, and will not be detrimental to the public health, safety, general welfare, or convenience; (b) the proposed use will be located and conducted in a manner in accord with the Burlingame general plan and the purposes of this title; (c) the Planning Commission may impose such reasonable conditions or restrictions as it deems necessary to secure the purposes of this title and to assure operation of the use in a manner compatible with the aesthetics, mass, bulk and character of existing and potential uses on adjoining properties in the general vicinity. Findings for a Condominium Conversion: Further specific findings must be made for a condominium conversion which are different from those required for planning permits (CS 26.32.110): (a) All provisions of this chapter are met; (b) The proposed conversion is consistent with the city's general plan; 0 Condominium Conversion Permit, Conditional Use Permit and Tentative Condominium Map 821 Cowan Road (c) The proposed conversion will conform to this code and other applicable code provisions, if any, in effect at the time of tentative map approval, except as otherwise provided in this chapter or specifically excepted by the planning commission; and (d) The overall design and physical condition of the condominium conversion achieves a high degree of appearance, quality, and safety. Planning Commission Action: The Planning Commission should hold a public hearing. Affirmative action bn the following items should be taken separately each by resolution. Findings should be made for the condominium conversion permit and conditional use permit. Each action should include the conditions from the staff report and conditions which the Commission may add. The reasons for any action should be clearly stated. The required actions are: 1. Condominium conversion permit. 2. Conditional use permit to exceed the maximum floor area. 3. Tentative condominium map. The resolution with conditions shall be recorded with each of the condominium properties and filed with the building permit to insure implementation of the conditions of approval. Please note that the conditions below which are in italics reflect the conditions of approval for the mitigated negative declaration, conditional use permits, parking and side setback variances originally approved for a first floor remodel and second floor addition to the existing office warehouse building. All of these conditions will be placed on the building permit if the project is approved: that the project shall be built as shown on the plans submitted to the Planning Deparhnent date stamped March 6, 2006, sheets L.2, A.3, A.3A, A.4 through A.7, D.l, E.1, E.2, C.1, AS.1 through AS.3, C-1 through C-5, Lighting Details (8%2" x 11" sheet) and date stamped April 13, 2006, sheets T.1 and L.1, Vesting Tentative Tract Map, and the Physical Elements Report, Physical Standards Report and Acoustical Assemblies Report date stamped December 27, 2005; 2. that the reports required by this code, in a form approved by the city, shall be provided to each person executing any purchase, rental or other agreement to purchase or occupy a unit in the project. Copies of the full reports shall be made available at all times at the sales office and shall be posted at various locations, as may be required by the city, at the proj ect site; 3. that a new 7'-0" wide sidewalk shall be installed along the front of this property as shown on the plans date stamped April 13, 2006, sheets T.1 and L.l; the new 7'-0" wide sidewalk, curb and gutter and driveway apron shall comply with the Public Works' construction standards and shall be installed prior to the final inspection; the applicant shall obtain the necessary special encroachment permit to install the curb, gutter and sidewalk and driveway apron; 4. that the applicant shall plant two 24-inch box Sycamore trees at the front of the property for replacement of the existing Sycamore tree to removed; 7 Condominium Conversion Permit, Conditional Use Permit and Tentative Condominium Map 821 Cowan Road 5. that the conditions of the City Attorney's February 3, 2006 memo, the City Engineer's January 30, 2006 memo, the Fire Marshal's January 4, 2006 memo, the Chief Building Official's January 3, 2006 memo, the Recycling Specialist's January 4, 2006, memo, and the NPDES Coordinator's January 6, 2006 memo shall be met; 6. that the final inspection shall be completed and a certificate of occupancy issued before the close of escrow on the sale of each unit; 7. that the developer shall provide to the initial purchaser of each unit and to the board of directors of the condominium association, an owner purchaser manual which shall contain the name and address of all contractors who performed work on the project, copies of all warranties or guarantees of appliances and fixtures and the estimated life expectancy of all depreciable component parts of the property, including but not limited to the roof, painting, common area carpets, drapes and furniture; 8. that if a security gate system across the driveway is installed in the future, the gate shall be installed a minimum 20'-0' back from the front property line; the security gate system shall include an intercom system connected to each unit which allows occupants to communicate with guests and to provide guest access to the parking area by pushing a button inside their units; 9. that demolition for removal of the existing structures or walls within the condominium units and any grading or earth moving on the site shall not occur until a building permit has been issued and such site work shall be required to comply with all the regulations of the Bay Area Air Quality Management District; 10. that the proj ect shall comply with the Construction and Demolition Debris Recycling Ordinance which requires affected demolition, new construction and alteration proj ects to submit a Waste Reduction plan and meet recycling requirements; any partial or full demolition of a structure, interior or exterior, shall require a demolition permit; Conditions of approval for the originally approved mitigated negative declaration, conditional use permits, parking and side setback variances: 11. that the project shall be built as shown on the plans submitted to the Planning Department date stamped February 4, 2005, sheets T.1, L.1, T.2, A.1 through A. 7 and Plat of Survey; 12. that a seating aYea, to be architectural compatible with the building, shall be designed at the front entrance to the building; 13. that vines, to gf-ow along the, front wall of the building, shall beplanted and maintained by theproperty owner; 14. that the windows and window trim shall be installed as shown on the detail, date stamped February 4, 2005; 15. that the parking variance shall only apply to this building and shall become void if the building zs ever expanded, demolished or destroyed by catastrophe or natural disaster or for intentional replacement; : Condominium Conversion Permit, Conditional Use Permit and Tentative Condominium Map 821 Cowan Road 16. that the conditions of the City Engineer's and Fire Marshal's June 1, 2004, memos, the Chief Building Official's FebYuary 9, 2005, and June 4, 2004, memos, the Recycling Specialist's June 2, 2004, memo and the NPDES Coordinator's .Ianuary 31, 2005, memo shall be met; 17. that payment of a Bayfront Development fee to the City of Burlingame for traffic impacts in the Inner Bayshore and Shoreline areas shall be required to mitigate cumulative impacts ofthis and otherprojects on area circulation, one-half of the fee is due at the time ofplanning application and one-halfdue before the final framing inspection; 18. that one-way directional signage shall be installed andpainted throughout the parking aYea to cZeaYly define the vehicular direction for employees and visitors to the site; prior to issuance of a building pe�mit, the applicant/property owner shall work with the City's traffic engineer to determine the required signage and markings on the pavement to clearly identify the on-site vehicular direction; 19. that the driveway aisles in front of the roll-up doors at the rear of the building and in theparking area shall be maintained clear and trucks shall not be stored or parked in the driveway aisles; 20. that the paved area adjacent to parking space #1 S shall be painted "No Parking" to provide a clear, unobstructed back-up area for the disabled-accessible parking spaces; 21. that the 53 on-siteparking spaces shall be used only for the customers and employees of the businesses at this site and shall not be leased or rented for stoYage of automobiles either by businesses on this site or by other businesses for off-site parking; 22. that the landscaping noted on sheet L.1 shall be installed according to plan and shall be irrigated with an automatic irrigation system; landscaping that does not survive on the site shall be immediately replaced with an equivalent species; 23. that the property owne� shall provide a complete Irrigation Water Management Conservation Plan together with landscape and irrigatzon plans at time of permit application; 24. that the office/warehouse building shall be built so that the interior noise level in all areas used as o�ce does not exceed 45 dBa; 25. that all construction shall abide by the construction hours established in the City of Burlingame Municipal Code, and shall occur only between the hours of 7: 00 a.m. and 7:OOp.m. on weekdays, 9: 00 a.m. and 6: 00 p.m. on Saturdays, and 10: 00 a.m. and 6: 00 p.m. on Sundays and holidays; 26. that on-site illumination shall be shielded and directed only on to the site in compliance with the City's exterior illumination ordinance; 27. that all parking areas should be lit for safety at night, such lighting should comply with the requirements of the City's exterior illumination ordinance; 28. that the remodel/addition shall not be built with a reflective exterior finish; E Condominium Conversion Permit, Conditional Use Permit and Tentative Condominium Map 821 Cowan Road 29. that the project shall obtain necessary permits to meet the standards of the required permitting agencies including: Bay Area Air Quality Management District; 30. that the project design shall conform to all seismic related requirements of the latest edition of the California Building Code as amended by the City ofBurlingame zn effect at the time a buildingpermit is issued and any additional seismic requirements established by the State Architect's office; 31. that all construction shall be required to be done in accordance with the California Building Code requirements, 2001 edition, as amended by the City ofBurlingame, and in addition to the limitations of hours of construction imposed by the City of Burlingame Municipal Code (CS 18.08.035); 32. that all new utility connections to serve the site and which are affected by the development shall be installed to meet current code standards and diameter; existing sewer laterals shall be checked and replaced if necessary; 33. that water and sewer lines shall be constructed from flexible material with flexible connections with the degree of flexibility established by the City Engineer and with his approval and inspection; 34. that in the event that there is subsidence as the result of an earthquake, the site shall be repaired as approved by the City Engineer; 35. that all site and roof drainage shall be directed to the street frontage; 36. that Zow flow plumbing fixtures shall be installed and City water conservation requirements shall be met at all times, including special additional emergency requirements; 37. that the grading plan shall be prepared by a licensed Civil Engineer and approved by the City Engineer. All applicable requirements of the NPDESpermit for the site shall be adhered to in the design and during construction; 38. that if construction is done during the wet season (October 1 S through April 1 S), that prior to October 1 S the developer shall implement a winterization program to minimize thepotential for erosion and polluted runoff by inspecting, maintaining and cleaning all soil erosion and sediment control prior to, during, and immediately after each storm even; stabilizing disturbed soils throughout temporary orpermanent seeding, mulching matting, or tarping; rocking unpaved vehicle access to limit dispersion of mud onto public right-of-way; covering/tarping stored construction materials, fuels and other chemicals; 39. that all applicable San Mateo County Stormwater Pollution Prevention Program Best Management Practices shall be adhered to in the design and during construction, including stabilizing areas denuded due to construction prior to the wet season; erosion shall be controlled during and after const�uction to protect San Francisco Bay waters; 40. that the applicant shall submit an erosion and sedimentation control plan describing BMPs (Best Management Practices) to be used to prevent soil, dirt and debris from entering the storm drain system; the plan shall include a site plan showing the propeYty lines, existing and proposed topography and slope; areas to be disturbed, locations of cut/fill and soil storage/disposal areas; areas with existing vegetation to be protected; existing and proposed drainage patterns and structures; watercourse or 10 Condominium Conversion Permit, Conditional Use Permit and Tentative Condominium Map 821 Cowan Road sensitive a�eas on-site or immediately downstream of a project; and designated construction access Youtes, staging areas and washout areas; 41. that the erosion and sedimentation control plans should include notes, specifications, and/or attachments describing the construction operation and maintenance of erosion and sediment control measures, including inspection frequency; methods and schedule for grading, excavation, filling clearing of vegetative cover and mulch, including methods and schedules for planting and fertilization; and provisions for temporary and permanent irrigation; 42. that all runoff created during constYuction and future dischaYge fi-om the site shall be required to meet the applicable San Mateo County Stormwater Pollution Prevention Program Best Management Practices for surface water runoff and Storm Drain maintenance; 43. that all runoff in theparking lot, including runofffrom the Zandscaped areas, shall befiltered to remove oil and grease prior to discharge by a method approved by the City Engineer and such facilities shall be installed and maintained by the property owner, failure to maintain such filters and facilities in working conditions shall cause this conditional use permit to be called up for �eview, all costs for the annual or more frequent inspection and enforcement of this condition shall be paid for by this project's property owner; 44. that the phrase "No Dumping-Drains To Bay" shall be labeled on new storm drain inlets by stenciling, branding, plaguing or casting; 45. that g�ading shall be done so that impacts from erosion and runoff into the storm drain will be minimal; 46. that each storm water inlet on the site shall be equipped with a sand/oil separator; all sand/oil separators shall be inspected and ser-viced on a regular basis, and immediately following periods of heavy rainfall, to ascertain the conditions of the chambers; maintenance records shall be kept on-site and maintenance shall be as directed by the City; 47. that drainage fYom paved surfaces, including parking lots, driveways and roofs shall be routed to storm water inlets equipped with sand/oil-separators and/or fossil filters, then the water shall be discharged into the storm drain system; the property owners shall be responsible for inspecting and cleaning (vacuuming out) sand/oil separators and changing fossil filters on a regular basis as well as immediately prior to, and once during, the rainy season (October 1 S— April 1) and as directed by the City; 48. that off-site runoffshall be diverted around the construction site and all on-site runoffshall be diverted aYound exposed construction areas; 49. that trash enclosures and dumpster areas shall be covered andprotected, from roof andsurface drainage and that if water cannot be diverted from these aYeas, a self-contained drainage system shall be provided that discharges to an interceptor; 50. that no vehicles or equipment shall be washed, cleaned, fueled o� maintained on-site; 11 Condominium Conversion Permit, Conditional Use Permit and Tentative Condominium Map 821 Cowan Road 51. that methods and procedures such as sediment basins or traps, earthen dikes or berms, silt fences, straw bale dikes, check dams storm drain inletprotection soil blanket or mats, and covers for soil stockpiles to stabilize denuded areas shall be installed during constructzon to maintain temporary erosion controls and sediment control continuously until permanent erosion controls have been established; 52. that the site shall be sprayed with water to control dust during grading and construction. Construction equipment emissions shall be in compliance with the standards of the Bay Area Air Quality Management District; 53. that a construction fence, including a impermeable fabric/material, shall be required around the site during construction to keep all construction debris on site; 54. that if any trenching is proposed on the site, the applicant shall contact the San Mateo County Health Department; if any contaminated soil is encountered, the applicant shall follow County protocol for its disposal; and 55. that if anyprehistoric or historic archeological relics are discovered during grading and construction, all work shall be halted until the finding can be fully investigated andproperprotection measures, as determined by qualified expet-ts, can be implemented. Ruben Hurin Planner c. One Stop Design, Inc., applicant Konstantinos Dokos, property owner 12 City ofBurlingame Planning Commission Unapproved Minutes March 27, 2006 4. 821 COWAN ROAD, ZONED IS (INNER BAYSHORE) — APPLICATION FOR CONDOMINNM CONVERSION PERMIT FOR AN EXISTING OFFICE/WAREHOUSE BUILDING (ONE STOP DESIGN, INC., APPLICANT; KONSTANTINOS DOKOS, PROPERTY OWNER; AND DOMINGUEZ ASSOCIATES, ENGINEER) PROJECT PLANNER: RUBEN HLJRIN CP Monroe presented a summary of the staff report which requested a commercial condominium conversion of a remodeled warehouse which is still under construction. Commission asked if this was approved as a rental. Staff noted that it was, and the project is currently under construction. He also asked if the previous impact studies still apply to this action. Staff noted that they did. There were no other questions of staff. Commissioners comment: no change from original approval; usually hold condominium development to a higher standard than rental, troubled by request may not have granted variances if knew it was to be a condominium; would the Bayfront Development Fee be different if this had been originally submitted as a commercial condominium? Staff responded no, the Bayfront and other development fees are the same. Does the condominium map entitle the city to more improvements? CA noted that could request a wider sidewalk at the front to comply with design guideline standards in the area, for example. Seems the question revolves around the existing building, and the variances granted originally were based on the retention of that building. How would parking be assigned for the condominium use, for the rental it would be common/shared. How is it insured that the landscaping will be maintained? Owners are aware of zoning but buyers may not be. Questions for findings seem to imply residential conversions no cornmercial. Sidewalk width for Bayfront should be 8 feet, same as existing, revised plans show 5 feet. Think need incubator space, appropriate for consent; not difficult like to see on action to hear answers on how transition from rental to ownership is being handled. Understand transition, CC and R's handle a lot of those things, they are recorded with the property, so issues addressed. Do not do many condominium conversions, good for the commission to look at one closely, hear from applicant. Request revisions: ■ Sidewalks at the front of the site along the public right-of-way shall be 8 feet wide with improvements consistent with the Bayfront Design guidelines for the Inner Bayshore area, to be installed by the property owner; ■ Provide information on how the on-site parking spaces will be allocated among the ownerships; and ■ Provide information on how the property and landscaping will be maintained among the ownerships. This item was set for the regular action calendar when all the information has been submitted and reviewed by the Planning Department. This item concluded at 7:45 p.m. VII. ACTION C;O ent (:alendar - lte on the consent calendar ar considered to be routine. They acte�l on simultaneously unless s arate discussion and/ action is requested by the a licant, a member of the public a commissioner prior to the time the commission votes on t e motion to adopt. 5A. 1416 BAL A AVENUE, ZON R-1 — APPLICATION OR DESIGN REVIEW A SPECIAL PERMI FOR HEIGHT AND CLINING HEIGHT E LOPE FOR A NEW, TW TORY SINGLE F Y DWELLING ETACHED GARAGE ATHERINE ANDERSO . APPLICANT ANB' D IGNER; CLEMEN EVA HUNG PROPER OWNERS) (66 NO' UREEN BROO (CONTINUED FRO FEBRUARY 27, 2006 3 ,� � ��/%,ONESTOPDESIGN From: OneStopDesign, Inc. Design and Engineering Services 3566 Beard Road Fremont, Ca. 94555 510-794-7993 (voice), 510-794-4178 (fax) www.onestopdesi�n.biz Date: Apri113, 2006 APR 1 `i 2006 CITY OF BUFiLINGAME PLAIVNING DEPT. To: City of Burlingame Planning Department Address: 501 Primrose Road City/State: Burlingame, CA Zip: 94010 Phone: 650-558-7250 FAX: 650-696-3790 Response to Planning Commission Revision Requests 1. Sidewalks have been modified to 7 feet in width, per Planning request. 2. On-site parking will remain as "Common Area". Parking will be allocated per tenant requirements as units are purchased. Submitted CC&R's will address the process. 3. Landscaping and common areas will be maintained per an Owner's Association, as defined by Prelim CC&R's submitted. Thank yo , _.-.' Greg ard, for OSD, Inc. `'�-_ _, contained in this Declazation and the rules. If an Owner has rented the Condaminium, the Owner and the Owner's employees and invitees shall not be entitled to use any Common Area Improvements. Such rights may be enjoy�ed by the tenant or contract purchaser and, as the case may be, their employees and invitees. � 2.10 Exclusive Use Common Area. (i) Certain portions of the Common Area are set aside for the exclusive use of specific Condominiums and constitute Exclusive Use Common Areas. (ii) Declarant or Declarant's assignee may assign one or more Exclusive Use Common Area parking spaces within Exclusive Use Common Area to Condominiums. The assignment shall be made in the grant deeds to the initial Condominium purchasers or by another appropriately recorded instrument of assignment. (iii) The Exclusive Use Common Area parking spaces are appurtenant to the Condominium to which it is assigned and may not be separated therefrom. Any transfer of the Condominium automatically transfers the exclusive use rights. appurtenant thereto regardless of whether the instrument of transfer describes the Exclusive Use Common Area rights. The right to use any Exclusive Use Comman Area may not be transferred to any Person other than to a.n occupant of the Condominium for use in connection with the occupancy of the Condominium. Any authorized use transfer shall be a license only and shall not transfer any other interest in the Exclusive Use Common Area, which shall remain appurtenant to the Condominium to which it is assigned. (iv) Except as described herein, no other portion of the Cornmon Area is Exclusive Use Common .Area. 2.11 Restrictions on Partition. (i) Except as authorized in Sections 2.8, 9.7 and 9.9, the Common Area shall remain undivided, and there shall be no judicial partition thereof except as may be authorized by Civil Code section 1359 or any successor statute thereto. (ii) Any proceeds or property resulting from a partition shall be distributed to and among the respective Owners and their Mortgagees as their interests appear in equal properties. 2.12 Public Dedication. Nothing in this Declaration shall be deemed to be a gift or dedication of any portion of the Development to the general public or for the general public or for any public purposes whatsoever, it being the intention of the Declarant that this Declaration shall be strictly limited to and for the purposes expressed in this Declaration. The right of the public or any Person to make any use whatsoever of the Development or any portion thereof (other than any use expressly allowed by a written or recorded map, agreement, deed or . dedication) is by permission only, constitutes a license revocable at will, and is subject to control of Owner. Notwithstanding any other provisions herein to the contrary, the Owners take such DKPC�4534T648841.2 -6- 3.7 Alterations. Modifications or Additions. There shall be no alterations, modifications or additions made to any Condominium or any Improvement thereon except in compliance with the provisions of Article 7. 3.8 Compliance with Law. No Owner shall permit anything to be done or kept in his or her Condominiuxn that violates any law, ordinance, statute, rule or regulation of any local, county, state or federal agency. Nothing shall be done or kept in any Condominium that might increase the rate of or cause the cancellation of any insurance maintained by the Association. �L ARTICLE 4- Maintenance and Repair Obli ations ���� 4.1 Owner's Maintenance and Repair Obli ations. (i) Each Owner of a Unit shall maintain his or her Unit and all Improvements therein in good condition and repair at all times, including, but not limited to, interior doors and walls, floors, cabinets, trade fixtures, appliances, and all electrical, heating, plumbing and other utility fixtures situated within the Unit or partially within the Unit and partially within the Common Area and exclusively serving the Unit, such as electrical outlets. Maintenance shall be in accordance with the Maintenance Standards described in Section 4.4. The washing of all windows, both exterior and interior, in a Unit shall be the responsibility of the Owner. Each Owner, at that Owner's cost, shall periodically clean, maintain and repair any'exterior door hardware that serve the Owner's Unit, including repair or replacement of any exterior door hardware. An Owner shall obtain the consent of the Association before installing any equipment which causes roof penetrations; and, upon installation shall be responsible for maintaining the same. Tf damage is covered by insurance maintained by the Association, the Association, on request from the Owner, shall submit an appropriate claim if the claim exceeds the deductible and shall remit any available insurance proceeds to the Owner on receipt of satisfactory evidence that the proceeds are or will be used for repair. Any deductible amount shall be borne by the Owner. The Association shall repair any damage to any exterior doors serving a Unit (other than the hardware thereon), provided that, if the damage is covered by insurance maintained by the Association, the Owner shall be responsible for paying any deductible amount. Maintenance shall be in accordance with the Maintenance Standards described in Section 4.4. (ii) Each Owner shall be responsible for the removal of all the trash and refuse from that Owner's Unit to the central trash collection points. The Association shall be responsible for the maintenance of the central trash collection points within the Common Area and for the periodic removal therefrom. All trash or refuse shall be kept only in sanitary containers which containers shall be kept in the areas approved by the Board. Each Owner shall take all appropriate, proper and required precautions to protect Persons and property from any injuries or damages from the trash or other refuse generated from the Owner's Condominium. The Rules adopted by the Board may regulate the trash collection areas. (iii) Any electrical wiring, plumbing pipes, drains, flues, heating ducts or other utility equipment that exclusively serves one (1) Unit, but is located in the Common .Area, shall be maintained and repaired by the Association; however, the maintenance, repair and/or replacement costs shall be paid by the Owner of the Unit. If the Owner fails to pay the cost, the DKPC145347�648841.2 -9- Association may levy a reimbursement assessment against the Owner's Condominium. If the utiliry equipment serves two (2) or more Units, the costs shall be borne by the Association. If the maintenance, repair and/or replacement involves equipment that exclusively benefits one (1) Unit and equipment that benefits two (2) or more Units, the Board shall allocate the cost between the Unit Owner and the Association in a fair and equitable manner. 4.2 Association's Maintenance, Repair and Landscaping Obli ag tions. (i) The Association shall maintain all of the improvements and landscaping located in and a part of the Common Area. Maintenance shall be in accordance with the Maintenance Standards described in Section 4.3. (ii) Unless otherwise maintained or repaired by governmental entity or public or private utility company, the Association shall maintain in good condition and repair all utilities and sanitary sewer and storm drainage facilities situated within the Common Area, including, but not limited to, meters, distribution lines, catch basins, storage tanks, wires, ducts, flues, pumps, boilers, pipes, and lighting fixtures. (iii) The Association shall have the Common Area periodically inspected for wood-destroying pests and organisms and shall take appropriate corrective measures therefor. 4.3 Maintenance Standards. (i) All Improvements and landscaping within the Development shall be maintained in a neat and attractive condition appropriate for a first-class commercial center and in compliance with all applicable laws and ordinances. It is intended that the Improvements be maintained in a like-new condition similar to the conditions on the completion of the original construction, reasonable wear and tear excepted. Maintenance may include periodic inspections by a Person competent to conduct the inspection to confirm compliance with the inspection and maintenance guidelines described in Section 4.4 to the extent applicable. Any maintenance, repair or replacement recommendations resulting from the inspection, shall be performed as soon as is reasonably practical after the inspection. (ii) All landscaping shall be maintained in a healthy and weed-free environment. Maintenance shall include regular fertilization, rnowing, imgation, pruning and other prudent landscaping practices. Dying or dead vegetation immediately shall be removed and replaced. Appropriate steps shall be taken to maintain the imgation of the landscaping and to prevent damage resulting from misdirected and/or excessive watering. All lawns shall be kept neatly mown and trees neatly trimmed and pruned at all times. 4.4 Inspection and Maintenance Guidelines. The Board may adopt inspection and maintenance guidelines for the periodic inspection and maintenance of the Common Area, including, but not limited to, foundation, gutters, down-spouts, siding, trim, roof, window caulking, utility equipment and sanitary sewer and storm drainage facilities maintained by the Association, driveways, parking areas, and the irrigation system. The guidelines may require inspection by a qualified Person of each of the foregoing. DKPC�4534'7�648841.2 -1 �- 4.5 Cooperation and Access. Each Owner and occupant shall fully cooperate with the agents of the Association in the performance of the Association's maintenance and repair obligations described in Section 4.2 above. Such cooperation shall include, but is not limited to, immediate notification to the Board or its managing agent of any maintenance or repair problems for which the Association is responsible and access to the Owner or occupant's Condominium and Exclusive Use Common Area as may be necessary to inspect and, if appropriate, to perform any necessary maintenance or repairs. 4.6 Hazardous Waste Requirements. (i) No Owner or occupant of any Condominium shall use, or permit the use of, nor store, generate, treat, manu£acture or dispose of Hazardous Materials (hereinafter defined) on, from or under the Condominium (individually and collectively "Hazardous Use") except to the extent that, and in accordance with all laws, ordinances and regulations of governmental agencies and such conditions as, the Board may approve in writing in its sole and absolute discretion. Notwithstanding the foregoing, the Owner or occupant shall be entitled to use and store only those Hazardous Materials which are (a) set forth in a list approved in writing by the Board, which shall be deemed given with respect to the Approved Hazardous Materials (hereinafter defined), (b) necessary for the Owner's business, but then only in the amounts and for the purposes previously disclosed in writing to and approved in writing by the Board, and (c} in full compliance with Environmental Laws (hereinafter defined) and all judicial and administrative decisions pertaining thereto. All Hazardous Materials approved in writing by the Board as provided in the preceding sentence shall collectively be referred to as the "Approved Hazardous Materials". Within thirty (30) days after request by the Board, Owner shall deliver to the Board a list of the Approved Hazardous Materials being used on Ovcmer's Condominium. No Owner or occupant shall be entitled to install any tanks under, on or about the Condominiurn for the storage of Hazardous Materials without the express written consent of the Board, which may be given or withheld in the Board's sole discretion. (ii) For the purposes herein, the term "Hazardous Use" shall include Hazardous Use(s) on, from or under the Condominium by any person occupying all or any portion of the Condominium, (including any tenant of Owner) and any of their directors, officers, employees, partners, managers, invitees, agents, contractors or Owners (collectively "Owner's Parties"). The term "Owner's Parties" shall include any person occupying all or any portion of the Condominium. � (ui) As used herein, the term "Hazardous Materials" shall rnean any wastes, materials or substances (whether in the form of liquids, solids or gases and whether or not air- borne) which are or are deemed to be (a) pollutants or contaminants, or which are or are deemed to be hazardous, toxic, ignitable, reactive, corrosive, dangerous, harmful or injurious, or which present a risk to public health or to the environment, or which are or may become regulated by or under the authority of any applicable local, state or federal laws, judgments, ordinances, orders, rules, regulations, codes or other governmental restrictions, guidelines or requirements, any arnendments or successor(s) thereto, or replacernents thereof of publications promulgated pursuant thereto, including, without limitation, any such items or substances which are or may become regulated by any of the Environmental Laws; (b) listed as a chemical known to the State DKPC�45347�648841.2 -11- of California to cause cancer or reproductive toxicity pursuant to section 25249.8 of the California Health and Safety Code, Division 20, Chapter 6.6 (Safe Drinking Water and Toxic Enforcement Act of 1986) or any successor statute thereto; or (c) a pesticide, petroleum, including crude oil or any fraction thereof, asbestos or any asbestos-containing material, a polychlorinated biphenyl, radioactive material, or urea formaldehyde. Tn addition to the foregoing laws, the term "Environmental Law" shall be deemed to include, without limitation, 33 U.S.C. section 1251 et seq., 42 U.S.C. section 6901 et seq., 42 U.S.C. section 7401 et seq., 42 U.S.C. section 9601 et seq., and California Health and Safety Code section 25100 et seq., and 25300 et seq., California Water Code section 13020 et seq., or any successor(s) law(s) thereto, all applicable local, state and federal laws, judgments, ordinances, orders, rules, regulations, requirements, any amendments and successors thereto, or replacements thereof of publications promulgated pursuant thereto which deal with or otherwise in any manner relate to, air or water quality, air emissions, soil or ground conditions or other environmental matters of any kind. (iv) If Owner knows or believes that any release of any Hazardous Materials has come or will come to be located upon, about or beneath the Condorninium, then Owner shall immediately, either prior to the release or following the discovery thereof by Owner, give verbal and follow-up written notice of that condition to the Board. At its sole cost and expense, Owner covenants to investigate, clean up and otherwise remediate any release of Hazardous Materials which arose from any act or failure to act of Owner or any of Owner's Parties. Such investigation, cleanup and remediation shall be performed only after Owner has obtained, if practicable, Board's written consent, which shall not be unreasonably withheld; provided, however, that Owner shall be entitled to respond immediately to an emergency without first obtaining Board's written consent. All cleanup and remediation shall be done in compliance with Environmental Laws and to the reasonable satisfaction of Board. (v) Notwithstanding the foregoing, the Association shall have the right, but not the obligation, in Board's sole discretion, exercisable by written notice to Owner, to undertake within or outside the Condominium all or any portion of any reasonable investigation, cleanup or remediation with respect to any Hazardous Use of such Hazardous Materials by Owner or any of Owner's Parties (or, once having undertaken any of such work, to cease same, in which case Owner shall perform the work), all at Owner's sole cost and expense, which shall be paid by Owner within ten (10) days after receipt of written request therefor by the Association (and which Board may require to be paid prior to commencement of any work by Board); provided, however, that Owner's obligation to pay for such work shall only be applicable if Owner fails to perform its obligations under this Section 4.6 (including without limitation the Owner's cleanup obligation.) If Owner fails to pay when due, the Association may levy a reimbursement assessment as described in Section 6.5 and may enforce the assessment as described in Seetion 6.10. No such work by Association shall create any liability on the part of Association to Owner or any other party in connection with such Hazardous Materials by Owner or any of Owner's Parties or constitute an admission by Association of any responsibility with respect to such Hazardous Materials. (vi) Owner shall indemnify, defend, protect and hold hannless the Association, the other Condominium Owners (including Declarant) and their officers, directors, members, employees, contractors, property managers, agents and Mortgagees (defined below) whenever DKPCk{5347�648841.2 -12- such Losses (hereinafter defined) arise from or related to: (i) any violation or alleged violation by Owner or any of Owner's Parties or any of the requirements, ordinances, statues, regulations or other laws referred to in this Section 4.6, including, without limitation, the Environmental Laws; (ii) any breach of the provisions of this Section 4.6 by Owner or any of Owner's Parties; or (iii) any Hazardous Use on, about or from the Condominium by Owner or any of Owner's Parties of any Hazardous Materials (whether or not approved by Association). Any indemnitee hereunder shall have the right to approve in writing and in advance any attorneys selected by the Owner and, in lieu thereof, shall have the right to retain his or her own counsel, the reasonable fees of which shall be paid by the Owner having caused such condition. The term "Losses" shall mean all claims, demands, expenses, actions, judgments damages (whether consequential, direct or indirect, known or unknown, foreseen or unforeseen), penalties, fines, liabilities, losses of every kind and nature (including, without limitation, property damage, d'iminution in value of Association's interest in the Condominium, darnages for the loss of restriction on use of any space or amenity within the Condominium, damages arising from any adverse impact on marketing space in the Condominium, sums paid in settlement of claims, and any costs and expenses associated with injury, illness or death to or of any person), suits, administrative proceedings, costs and fees, including, but not limited to, attorneys' and consultants' fees and expenses, and the cost of cleanup, remediation, removal and restoration that are in any way related to any matter covered by the foregoing indemnity. 4.7 Reimbursement and Indemnification. (i) If any Owner, occupant, tenant, invitee or agent damages any Common Area Improvements maintained by the Association, the Owner, on demand from the Association, immediately shall reimburse the Association for any costs, including attorneys' fees, resulting from such damage. The Owner's reimbursement obligation shall be reduced by the actual amount of insurance proceeds received by the Associarion, if any, to repair or replace the damaged Improvement. Any deductible amounts shall be paid by the Owner having caused such condition. Furthermore, the Owner having caused such condition shall defend, indemnify, protect and hold the Association harmless from any claim, dernand, liability or cost, including attorneys' fees arising from such damage. If an Owner having caused such condition fails to reimburse the Association within thirty (30) days of the demand for reimbursement, the Association rnay levy a reimbursement assessment against the Owner's Condominiuxn and may enforce the assessment, including the establishment and enforcement of a lien, as described in Sections 6.5 and 6.10. (ii) In the event of any water leak or overflow from any Unit that damages any Common Area or other Unit, the Owner and occupants of the Unit that is the source of the water leak or overflow (the `.`Responsible Owner") shall cooperate with the Association in the inspection and correction of the problem. Cooperation shall include access to the Unit to inspect and to correct the problem and/or repair any damage. The Responsible Owner shall reimburse the Association for its repair cost to the extent the cost is not paid through insurance maintained by the Association, and the Association may levy a reimbursement assessment to recover the cost. Tf the damage is covered by insurance maintained by the Association, the Association shall submit an appropriate claim. Any deductible amount shall be paid by the Responsible Owner. DKPCkt5347�648841.2 -13- City of Burlingame Planning Commission Minutes February 28, 2005 have the variance ided if the use changes frg�n what is described in thi,sruse permit or if the build�ixPg is demolished. / / / C. Boju' moved to approve this con 'tional use permit for aut ales wholly within a war ouse building by re lution with additional con ' ions to allow single car d iveries to the site using a bed truck only of a' e which can be backed int he warehouse area for ading on site and that thi ariance shall become oid if the use as approve s modified or the buildi is demolished, and inclu 'ng the conditions in the staff report as amended nd follow: 1) that this condit' nal use permit at 1275 R ins Road shall be for aut obile sales only which is who enclosed withi a warehouse structure w' no outdoor automobile d' play area; the use of this site s 1 be configured shown on the plans sub 'tted to the Planning Dep ent and date stamped January , 2005, sheet A- and A-2, site plan and or plan; with no on-site king provided; 2) that auto obile sales invent at this location shall n exceed three vehicles at a given time; 3) that the hour f operation of this usiness shall be limite o Monday through Satur 9:00 a.m. to 5:00 p.m., wit a maximum of 5 ople in this tenant space any one time (including er, employees and custom ); 4) that there shall be no more than three e loyees total including the wner or owners of the busin s working from this site; 5) that inventory ve cles to be sold shall be s red within the building, an are prohibited from being parked, stored, dis ayed or exhibited on the s eet, on Rollins Road, North arolan Avenue or Whitethorn Way; 6) that c s may be delivered to this ' e individually on a flat bed ck which can be backed into t warehouse a the car unloaded inside t e warehouse; no car shall b delivered to this site by a mul '- ar carrier tru , that the cars delivered b multi-car carrier truck mu be unloaded at a location ap ved by the Cit and driven to the site durin usiness hours; failure to h e an approved unloading site to use any adj ent public or private street or loading or unloading c s to be sold, leased or tr ferred by this b siness shall result in review and possible revocation o 's conditional use permit an parking variance; 7) that the parlcing variance or this auto sales wholly en osed in a warehouse buildi shall become void if the use of this site is ch ged or if the building is e r demolished; 8) that no anners shall be used to advertise car sales at 's locations and that the plicant shall apply for all the necessary permits r signage on this site s per Burlingame Title 22 egulating signs; and 9) that ny improvements or c nges necessary for thi se in this structure as dete ined by the Chief Buildin fficial or Fire Mars shall be done in compl' nce with the provisions of e California Building and 're Codes as amende y the City of Burlingame The motion was seconde y C. Keighran. Chair�'sterling called for a voic vote on the motion to app�6ve with amende�nditions. The motion passed 6-0. Appeal procedures ere advised. This item concluded at 10:05 p. 9. 821 COWAN ROAD, ZONED O-M — APPLICATION FOR MITIGATED NEGATIVE DECLARATION, SIDE SETBACK AND PARKIl�tG VARIANCES, AND CONDITIONAL USE PERMITS FOR A FIRST FLOOR REMODEL AND SECOND FLOOR ADDITION TO AN EXISTING OFFICE/WAREHOUSE BUILDING (GREG WARD, ONESTOP DESIGN, INC., APPLICANT AND DESIGNER; KONSTANTINOS DOKOS, PROPERTY OWNER) (15 NOTICED) PROJECT PLANNER: RUBEN HURIN Reference staff report February 28, 2005, with attachments. Plr Hurin presented the report, reviewed criteria and staff comments. Forty-one conditions were suggested for consideration. Commission asked how the parking variance changed. Plr noted that parking variances for total number of on-site parking spaces and number of compact parking space were eliminated, however a parking variance for aisle width at the north 14 City of Burlingame Planning Commission Minutes February 28, 2005 and south ends of the parking lot is still required. Commission noted that the tables showing how this project met the Bayfront Design Guidelines were presented well in the staff report. Chair Osterling opened the public hearing. Greg Ward, designer, One Stop Design, Inc., 3566 Beard Road, Fremont, and Konstantinos Dokos, property owner, were present to answer questions, intent was to upgrade the area but not overwhelm the existing buildings, articulated the left side of the building to comply with the setback requirements, now only the one-foot wide architectural column features extend into the setback, parking layout was revised to comply with disabled-accessible parking requirements, proj ect now meets the parking requirements with the exception of the aisle widths, and added landscape fingers to the parking area; there is a problem with drainage at the rear corner of the lot, will have to re-grade and provide a new drainage system in the parking lot; building will contain a red, s-tile roof, building will be broken up using two colors, an arch was incorporated over the entrance to the building; in regards to the window, can do a raised stucco or wood trim, provided a detail for the window trim, windows will be white vinyl; this will be a great building for businesses that have an office and also need space for light manufacturing. Commission noted that at the last meeting there was some discussion about adding a base to the fa�ade on the front of the building to help articulate the blank wall, feel that other treatment is needed at the front, was this considered? Designer noted that vines will be incorporated into the landscape design so that they grow on the exterior walls, window details as provided will also help. Commission noted that there is no area set aside on the ground floor for employees to use, can this be incorporated somehow? Designer noted that the front path to the building can be enhanced with benches or seating blocks, can incorporate into the final design. Commission noted that the narrow landscape fingers in the parking lot will not do much, should they be eliminated for wider parking aisles? Designer indicated that he tried to meet the parking requirement and provide landscaping in the parking area, feel that the landscaping fingers as proposed will help to break up the long rows of parking to make the parking lot look pleasant, eliminating the landscaping fingers would only pick up a few extra feet, not enough to eliminate the parking variance for aisle width. There were no further comments and the public hearing was closed. C. Brownrigg moved to approve the mitigated negative declaration and addendum, by resolution, find it satisfied the requirements of the California Environmental Quality Act, with the mitigation measures as outlined in the initial study for the project. This motion was seconded by C. Vistica. Chair Osterling called for a voice vote on the motion to approve the mitigated negative declaration and addendum. The motion passed 6-0. C. Brownrigg moved to approve the application, by resolution, with the following amended conditions: 1) that the project shall be built as shown on the plans submitted to the Planning Department date stamped February 4, 2005, sheets T.1, L.1, T.2, A.1 through A.7 and Plat of Survey; 2) that a seating area, to be architectural compatible with the building, shall be designed at the front entrance to the building; 3) that vines, to grow along the front wall of the building, shall be planted and maintained by the property owner; 4) that the windows and window trim shall be installed as shown on the detail, date stamped February 4, 2005; 5) that the parking variance shall only apply to this building and shall become void if the building is ever expanded, demolished or destroyed by catastrophe or natural disaster or for intentional replacement; 6) that the conditions of the City Engineer's and Fire Marshal's June 1, 2004, memos, the Chief Building Official's February 9, 2005, and June 4, 2004, memos, the Recycling Specialist's June 2, 2004, memo and the NPDES Coordinator's January 31, 2005, memo shall be met; 7) that payment of a Bayfront Development fee to the City of Burlingame for traffic impacts in the Inner Bayshore and Shoreline areas shall be required to mitigate cumulative impacts of this and other projects on area circulation, one-half of the fee is due at the time of 15 City of Burlingame Planning Commission Minutes February 28, 2005 planning application and one-half due before the final framing inspection; 8) that one-way directional signage shall be installed and painted throughout the parking area to clearly define the vehicular direction for employees and visitors to the site; prior to issuance of a building permit, the applicant/property owner shall work with the City's traffic engineer to determine the required signage and markings on the pavement to clearly identify the on-site vehicular direction; 9) that the driveway aisles in front of the roll-up doors at the rear of the building and in the parking area shall be maintained clear and trucks shall not be stored or parked in the driveway aisles; 10) that the paved area adjacent to parking space #15 shall be painted "No Parking" to provide a clear, unobstructed back-up area for the disabled-accessible parking spaces; 11) that the 53 on- site parking spaces shall be used only for the customers and employees of the businesses at this site and shall not be leased or rented for storage of automobiles either by businesses on this site or by other businesses for off-site parking; 12) that the landscaping noted on sheet L.1 shall be installed according to plan and shall be irrigated with an automatic irrigation system; landscaping that does not survive on the site shall be immediately replaced with an equivalent species; 13) that the property owner shall provide a complete Irrigation Water Management Conservation Plan together with landscape and irrigation plans at time of permit application; 14) that the office/warehouse building shall be built so that the interior noise level in all areas used as office does not exceed 45 dBa; 15) that all construction shall abide by the construction hours established in the City of Burlingame Municipal Code, and shall occur only between the hours of 7:00 a.m. and 7:00 p.m. on weekdays, 9:00 a.m. and 6:00 p.m. on Saturdays, and 10:00 a.m. and 6:00 p.m. on Sundays and holidays; 16) that on-site illumination shall be shielded and directed only on to the site in compliance with the City's exterior illumination ordinance; 17) that all parking areas should be lit for safety at night, such lighting should comply with the requirements of the City's exterior illumination ordinance; 18) that the remodeUaddition shall not be built with a reflective exterior finish;l9) that the proj ect shall obtain necessary permits to meet the standards of the required permitting agencies including: Bay Area Air Quality Management District; 20) that the project design shall conform to all seismic related requirements of the latest edition of the California Building Code as amended by the City of Burlingame in effect at the time a building permit is issued and any additional seismic requirements established by the State Architect's office; 21) that all construction shall be required to be done in accordance with the California Building Code requirements, 2001 edition, as amended by the City of Burlingame, and in addition to the limitations of hours of construction imposed by the City of Burlingame Municipal Code (CS 18.08.035); 22) that all new utility connections to serve the site and which are affected by the development shall be installed to meet current code standards and diameter; existing sewer laterals shall be checked and replaced if necessary; 23) that water and sewer lines shall be constructed from flexible material with flexible connections with the degree of flexibility established by the City Engineer and with his approval and inspection; 24) that in the event that there is subsidence as the result of an earthquake, the site shall be repaired as approved by the City Engineer; 25) that all site and roof drainage shall be directed to the street frontage; 26) that low flow pluxnbing fixtures shall be installed and City water conservation requirements shall be met at all times, including special additional emergency requirements; 27) that the grading plan shall be prepared by a licensed Civil Engineer and approved by the City Engineer. All applicable requirements of the NPDES permit for the site shall be adhered to in the design and during construction; 28) that if construction is done during the wet season (October 15 through April 15), that prior to October 15 the developer shall implement a winterization program to minimize the potential for erosion and polluted runoff by inspecting, maintaining and cleaning all soil erosion and sediment control prior to, during, and immediately after each storm even; stabilizing disturbed soils throughout temporary or permanent seeding, mulching matting, or tarping; rocking unpaved vehicle access to limit dispersion of mud onto public right-of-way; covering/tarping stored construction materials, fuels and other chemicals; 29) that all applicable San Mateo County Stormwater Pollution Prevention Program Best Management Practices shall be adhered to in the design and during construction, including stabilizing areas denuded due to construction prior to the wet season; erosion shall be controlled during and after construction to protect San Francisco Bay waters; 30) that the applicant shall 16 City of Burlingame Planning Commission Minutes February 28, 2005 submit an erosion and sedimentation control plan describing BMPs (Best Management Practices) to be used to prevent soil, dirt and debris from entering the storm drain system; the plan shall include a site plan showing the property lines, existing and proposed topography and slope; areas to be disturbed, locations of cut/fill and soil storage/disposal areas; areas with existing vegetation to be protected; existing and proposed drainage patterns and structures; watercourse or sensitive areas on-site or immediately downstream of a proj ect; and designated construction access routes, staging areas and washout areas; 31) that the erosion and sedimentation control plans should include notes, specifications, and/or attachments describing the construction operation and maintenance of erosion and sediment control measures, including inspection frequency; methods and schedule for grading, excavation, filling clearing of vegetative cover and mulch, including methods and schedules for planting and fertilization; and provisions for temporary and permanent irrigation; 32) that all runoff created during construction and future discharge from the site shall be required to meet the applicable San Mateo County Stormwater Pollution Prevention Program Best Management Practices for surface water runoff and Storm Drain maintenance; 33) that all runoff in the parking lot, including runoff from the landscaped areas, shall be filtered to remove oil and grease prior to discharge by a method approved by the City Engineer and such facilities shall be installed and maintained by the property owner, failure to maintain such filters and facilities in working conditions shall cause this conditional use permit to be called up for review, all costs for the annual or more frequent inspection and enforcement of this condition shall be paid for by this project's property owner; 34) that the phrase "No Dumping-Drains To Bay" shall be labeled on new storm drain inlets by stenciling, branding, plaguing or casting; 35) that grading shall be done so that impacts from erosion and runoff into the storm drain will be minimal; 36) that each storm water inlet on the site shall be equipped with a sand/oil separator; all sand/oil separators shall be inspected and serviced on a regular basis, and immediately following periods of heavy rainfall, to ascertain the conditions of the chambers; maintenance records shall be kept on-site and maintenance shall be as directed by the City; 37) that drainage from paved surfaces, including parking lots, driveways and roofs shall be routed to storm water inlets equipped with sand/oil-separators andlor fossil filters, then the water shall be discharged into the storm drain system; the property owners shall be responsible for inspecting and cleaning (vacuuming out) sandloil separators and changing fossil filters on a regular basis as well as immediately prior to, and once during, the rainy season (October 15 — April 1) and as directed by the City; 38) that off-site runoff shall be diverted around the construction site and all on-site runoff shall be diverted around exposed construction areas; 39) that trash enclosures and dumpster areas shall be covered and protected from roof and surface drainage and that if water cannot be diverted from these areas, a self- contained drainage system shall be provided that discharges to an interceptor; 40) that no vehicles or equipment shall be washed, cleaned, fueled or maintained on-site; 41) that methods and procedures such as sediment basins or traps, earthen dikes or berms, silt fences, straw bale dikes, check dams storm drain inlet protection soil blanket or mats, and covers for soil stock piles to stabilize denuded areas shall be installed during construction to maintain temporary erosion controls and sediment control continuously until permanent erosion controls have been established; 42) that the site shall be sprayed with water to control dust during grading and construction. Construction equipment emissions shall be in compliance with the standards of the Bay Area Air Quality Management District; 43) that a construction fence, including a impermeable fabric/material, shall be required around the site during construction to keep all construction debris on site; 44) that if any trenching is proposed on the site, the applicant shall contact the San Mateo County Health Department; if any contaminated soil is encountered, the applicant shall follow County protocol for its disposal; and 45) that if any prehistoric or historic archeological relics are discovered during grading and construction, all work shall be halted until the finding can be fully investigated and proper protection measures, as determined by qualified experts, can be implemented. The motion was seconded by C. Auran. 17 City of Burlingame Planning Commission Minutes �N REVIEW, SP] E FOR A FIRST TAYLOR, PROF Comment on the motion: Cannot approve as proposed, feel there is a lot than can be done to enhance the project further. CA Anderson noted that the parking variance can be tied to the existing building. The maker of the motion and second agreed to amend the motion with this requirement. The designer eliminated two parking variances, has been open to the Commissions' ideas throughout the review process, like the way open decks were incorporated into the second floor, adds to the design and articulation, this project is a good start for the redevelopment of this area as encouraged by the recently approved Specific Plan. Chair Osterling called for a voice vote on the motion to approve. The motion passed 5-1 (C. Vistica dissenting). Appeal procedures were advised. This item concluded at 10:30 p.m. IX. DESIGN VIEW STUDY ITEMS 10. 11 DRAKE AVENU , ZONED R-1 - APPLICA RMIT FOR HEIG FOR A FIlZST AND SEC( APPLICANT AND CHITECT; TOM AND LORi�' CP Monroe�lriefly presented the proj ect Chair (�terling opened the public co ent. Robert Medan chitect, 1936 Los Altos Drive, San ateo, that the family needs more s ce for large family, ecial permit for height requested to atch the ig roof pitch, there is a sm retaining wall at the ont which raises the property above e top of curb Commission noted t t this site can han the height well because there is lot of mature landscaping. Comm' lot? Architect noted $80K. Commission existing building ` will provide o utu� was closed. �io sked if the applicant nsidered moving the detached gara further back on the its not possible now b cause of budget constraints, would st an additional $60K- ;ked why existing b' ding elevations were not provide . Architect noted that the ope was dashed i hought this would be enough to c pare existing and proposed, submittals. Th e were no other comments from t floor and the public comment C. Kei an noted that the des' blends in with the existing hou and made a motion to place this i on the nsent calendar as pro osed. This motion was seconde y C. Auran Comment on motion: ommission expressed a concern rth the second floor cantilever a e rear, left side of the house; cantil er works well since it will create shadow line over the window stairway, architect has done a nice j with this project. Chair Oster ' g called for a vote on the moti to place this item on the con nt calendar as the projec 's proposed he motion passed on a voice v e 6-0. The Planning Commis 'on's action is advisory a not appeal le. This item concluded at 11: p.m. 11. 21 CHAPIN LANE, ZONED R- ATTACHED GARAGE (ERIKO STAUBER, APPLI 7 = APPLICATION FOR SIDE SETBACK VAR AND ARCHITECT; S' RUBEN HURIN_ _ / February 28, 2005 �ERMIT FOR OR ADDITION TY OWNER) (50 Plr Hurin briefly preserr%d the proj ect description. There were no questions of staff. 'FOR DESIGN STORY ADDI� ,E, PROPERT�' ��E�W AND SPECIAL elN (ROBERT MEDAN, OWNERS) (64 NOTICED) ption. There were r�,e;questions of staff. : .- --_� ' �� � J '�. i ,�..✓ City of BurIingame Chapter 26.32 CONDOMINIUM CONVERSION PERMTTS y Sections: 2632.010 Purpose. 26.32.020 Condominium conversion permit required. 26.32.025 Conversion prohibited for twenty or fewer units or less than 20,000 square feet if commercial, office, or industrial. 26.32'.030 Application requirements. 2632.040 Physical elements report. 26.32.050 Additional submittais. 26.32.060 Acceptance of reports. 26.32.070 Copy to buyers. 26.32.080 Physical standards for condominium conversions. 26.32.085 Minimum Requirements. 26.32.090 Hearing. 26.32.100 Hearing considerations. 26.32.110 Fiudings. � 2632.010 Purpose. Ttie city finds and determines that condominiums dif- fer from buildings in which all units are in a single own- ership in numerous respects and for the benefit of public health, safety-and welfare, condominium projects should be treated differently. The city therefore states its ex- press intent to adopt regulations for the conversion of ex- isting buildings. to candominium or cooperative owner- ship. Condominium conversion regulations are for the protection of displaced tenants and the purchasers of condominiums and cooperatively owned buildings. The purposes of this cfiapter aze therefore: (a) To establish criteria for conversion of the existing multiple family rental housing to condominiums, com- munity apartments, cooperatively owned property, and any other subdivision which is a conversion of existing rental housing, commercial, office or industrial build- ings; . (b) To reduce the impact of such conversions on residents in rental housing and tenants in commercial, office and industrial buildings who may be required to relocate due to the conversion to condominium owner- ship by providing for procedures for notification and adequate time and assistance for such relocation; (c) To assure that adequate information as to about the physical conditions of the structure which is offered for purchase is made available to purchasers of conveited housing, commercial, offce or industrial spaces; (d) To insure that converted properties achieve a� high degree of appearance, quality and safety and is con- sistent with the general plan and zoning goals of the city; (26.32) 1 (e) To provide a reasonable balance of ownership and rental housing in ihe city and a variety of choices of tenure, type, price, and location of housing; and (� To maintain a supply of rental housing for eld- erly, handicapped, and low and rnoderate income per- sons. (1707 § 2, Amended, OS/OS/2003; 1206 § 2(part), Added, OS/04/1981) 26.32.020 Condominium conversion permit required. Before final approval and issuance of any building permit for any condominium conversion project, a de- veloper, builder or other person seeking to construct such a project shall first apply for and obtain from the plan- ning commission a condominium conversion permit. Such condominiam conversion permit shall be issued only: (a) Upon approval of the planning commission, or city council upon appeal or review, after it detertnines that the project has adequately met all the disclosure and upgrade requirements for conversion as required in this chapter or the planning commission has waive the re- quirement base@ on findings related to the property; and (b) Upon approval of the planning commission, or city council upon appeal or review, af�er it determines that such the project conforms to all applicable wning regulations of title 25 of this code; and •(c) Upon�ihe payment of fees in the amount required by section 26.24.090 and council resolution. Applications for condominium new construction permits shall be evaluated and processed pursuant to the procedural requirements set forth for conditional use permits in title 25 of this code. (1707 § 2, Amended,�5/0512003;t206 § 2 (part), Added, OS/04/1981) 26.32.025 Conversion pro6ibited for twenty or fewer units or less than 20,000 square feet if commercial, office, or industrial. No application shall be accepted, and.no conversion shall be allowed, for any residential project which will produce twenty (20) or fewer condominium units or if rn a commercial, office or industrial structure, containing less than 20,000 square feet of building area. (1707 § 2, Amended, OS/OS/2003; 120b § 2(part), Added, OS/04/1981) 2632.030 Application requirements. , No application for a condominium conversion project shall be accepted for any purpose unless the application includes the following: (a) A site plan based on a site survey with at least the following details shown to scale: . March 2004 City of BurIingame (1) The location, height, gross floor area and pro- posed uses for each existing structure to remain and for each proposed new structure; (2) The location, use and type ofsurfacing for ali open storage areas; (3) The location and type of surfacing'for all drive- ways, pedestrian ways, vehicle parking azeas and curb cuts; (4) T'he locarion, height and type of materials for walls or fences; (5) The location of all iandscaped areas, the type of landscaping and method of irrigation; (6) The location and description of all recreational facilities; (7) The location, size and number of parking spaces to be used in conjunction with each condominium unit; (8) The location, type and size of all drainage pipes and structures; (9) The location and type of all on-site and nearest ofi�site fire hydrants; (10) A detailed Iighting plan indicating location and nature of lighting and lighting fixtures on the site and structure and in the common areas; �-• (1 }) The tocation, type and size of all on-site and ad- jacent overhead utility lines; and (12) A gradingplan�showing existing contours, building pad elevations and percent slope for all drive- ways and parking areas. (b) Fully dimensioned elevation ptans for all struc- tures on the site, showing the architectural features and type of material of construction. (1707 § 2, Amended, OS/OS/2003; 1206 §,2•(part), Added, OS/04/1981) , 26.32.040 Physical elements report. A report on the physical elements of all structures and facilities shall;also be submitted with the application. The report shall inciude, but not be limited to, the fol- lowing: �(a) A repart detailing the structural condition of al! elements inciuding structures, paving and fences of the property�including, but not limited to, foundations, elec- trical, plumbing, utilities, walis, ceilings, windows, rec- reational facitities, fire protection sprinklers, alarms, me- cfianical equipment, roof, parking facilities and appli- ances, including all appliances installed in each unit. Such report shall be prepared by a registered civil or sfructural engineer " � � Regarding each such element, the report shall state, to the best knowledge or estimate of the professional pre- paring the report, when such element was buiit, the con- dition ofeach element,'when the'element was replaced, the approximate date upon which the element will re- quire replacement, the remaining useful life of the ele- ment, the cost of replacing the element, and any variation to the physical condition of the element from the current zoning and from the building code in effect on the date of the report. The report shall identify any defective or unsafe elements and set forth the proposed corrective measures to be employed, including making ail struc- tures compliant with the California Building and Fire Codes in effect at the time the report is submitted to the city; (b) A report containing acoustical test data which in- dicates the noise attenuation characteristics of existing party walls and ceilings. The data for such report shall � include a representative sampling of anits involved in the project, but in no case fewer than two dwelling units, and shall be compiled by a qualified licensed acoustical en- gineer experienced in the field of acoustical testing and engineering. The consultant shall be selected by the city and shall perform the sampting in areas or units as ap- proved or directed by the city. (c) A report prepared by a licensed civil engineer evaluating the prospects for providing separate utilities for the individual units; (d) A study of off-street parking, on-site maneuver- ing and parking stall access provided on site prepared b.y a licensed civil engineer; ,. (e) A report from.a licensed structural pest control operator, approved by tfie city, on each structure and each unit within the structure. ( fl A report prepared by a licensed soils engineer on any known soil and geological conditions regarding soil deposits, rock formations, faults, groundwater and land- slides in the vicinity of the-project, and a stafement re- garding any known evidence of soils problems relaring to the structures. Reference shall be made to any previous soils reports for the site and a copy submitted with the �, report. . , (g) A statement of repairs and improvements to be made by the subdivider necessary to refurbish and re- . store the project to achieve a high degree of appearance and to achieve full compliance with the current, applica- bie requirements of the Califorriia Buiiding and Fire . Codes and requirements of the zoning code. (h) Provisions for the dedication of land or ease- ments for street widening, public access or other public purpose, where necessary, and in accordance with estab- lished planned improvements. (1707 § 2, Amended, 05/OS/2003; 1206 § 2(part), Added, OS/04/1981) 26.32.050 Additional submittals. The following shall also be submitted with the appli- cation: �� March 2004 (26.32) 2 . �, , ; : ;J City of Burlingame26.32.060 (a) A draft declaration of the covenants, conditions and restrictions, conforming to Department of Real Es- tate requirements, which would be applied on behalf of. any and alZ owners of condominium units within the pro- ject. The draft declaration shall include, but not necessary ily be limited to, the conveyance of units, the assignment of parking; an agreement for common azea maintenance, including facilities and }andscaping (together with an es- timate of any initial assessment fees anticipated for such maintenance), description of a provision far maintenance of all vehicular access areas within the project; and an indication of appropriate responsibilities for maintenance of all utility lines and services for each unit, provide for on-going maintenance of landscaping and physical facili- ties on the site including all structures and fencing, and designation of the responsibility to the condominium as- sociation to require and enforce that all onsite parking spaces shall be used only by operating vehicles and not for storage of boats, camper shelis or other personal pos- sessions. The ileclaration shall inctude all provisions required pursuant to tenant retention and relocation re- quirements of chapter 2633 of this code. (b) Specific information concerning the demographic characteristics of the pioject, including but not limited to the following: (1) Square footage and number of rooms in each unit, (2) Rental rate history for each type of unit for previ- ous two years, (3) Monthly vacancy rate for each month during the preceding two years, (4) Composition of existing tenant households, in- cluding household size, length of residence, age of ten- ants, and whether receiving federal or state rent subsidies or number of employees by tenant and rents charged for commercial, industriai, and o�ce uses; (5) Proposed sales price of units, � (6) Proposed homeowners association fee, (7) Proposed financing, and •(8) Names and addresses of aIl tenants. � When the developer can conclusively demonstrate that some of this information is not available;'this re- quirement may be modified by the planning department; (c) Signed copies from each tenant of a notice of in- tent to convert as reqaired by this code, or for tenants from whom a notice of intent to convert is not submitted by applicant; proof of notice by certified mait to such tenants. At the election of the applicant, the copies of the notice of intent to convert and the proof of notice shall . be sulimitted aftei the filing of the application, provided that such copies and proof shall be submitted prior to any public hearing on the proposed conversion; (d) Signec� consent to the conversion by. the fenants .. of at least a rriajority of the units; (26.32) 3 (e) Any other information which, in the opinion of the planning department, will assist in determining whether the proposed project will be consistent with the purposes of ihis code. c (1707 § 2, Amended, OS/OS/2003; 1206 § 2(part), Added, OS/04/1981) ' 26.32.060 Acceptsnce of reports. The fina} form of the site plan, physical elements re- port and other submitted documents shall be as approved by the city. The reports in their accepted form shall re- main on file with Che planning deparhnent for review by any interested persons. (1707 § 2, Amended, OS/OS/2003; iaos § 2��>, aaaea, osioaii9s�� . 2632.070 Copy to buyers. A summary of all reports required by this code,'in a form approved by the city, shali be provided to each per- son executing any purchase, rental or other agreement to purchase or accupy a unit in the project. Copies of ttie , full reports shall be made available at all times at the sales office and shall be posted at various locations, as may be required by the city, at the project site. (1707 § 2, Amended, OS/OS/2003; 1206 § 2(part), � .Added, OS/04/1981� � 2632.080 Physical standards for condominium • � conVersions. (a) Adeguate Physical Conditions. To achieve the purpose of this chapter, the planning commission shal) require, except as may otherwise be provided in this code, that all units to be converted to condominium con- form to the Burlingame Municipal Code in effect at the time of tentative mapapprova�, irrc9uding all building and fire codes. All violations of the city code and all required modi-. fications of units of the project must be corrected prior to. the approval of the final map, or, upon approval of the planning commission, funds shall be adequately es- crowed, prior to the closing of escrow of a unit, to assure completion thereaRer of such corrective work. (ti} Sp'ecific Physical Standards. In addition to any other reqairements, the following specific standards and requirements shalt be met: ( I) Fire Prevention -- Smoke Detectors and Sprin- klers. Each condominiam unit whether residential, commercial, industrial or of�ice, shall be provided with a fire sprinkler system and approved detectors of products of combusfion other than heat conforriung to the latest �' Califomia Building and Fire Code standards. (Z) Sound Transmission. (A) Shock Mounting of Mechanical Equipment. All permanenf inechanical equipment, such as motors, com- : pressors, pumps and compactors which are detemuned March 2004 City of Burlingame by the chief building of�icial to be a source of structural vibration or structure-bome noise shall be shock mounted with inertia biocks or bases and/or vibration isolators in a manner approved by the chief building of- ficiaL (B) Noise Standards. The structure shall conform to all exterior and interior sound transmission standards of the California Building Code and the.city's general plan. In those cases where present standards cannot reasonably be met, the planning commission may require the appli- cant to no6fy potential buyers of the noise deficiency currently existing within these units. (3) Utility Metering: (A) The consumption of gas and electricity within each unit shall be separately metered so that the unit owner can be separateiy billed for each utility. A water shut-off :valve shall be provided for each unit or for each plumbing fixture. The planning commission may find at. the time of approval that individual metering of gas. and electricity is impractical and excessively expensive and waive those requirements. Each unit having individuai meter(s) or heater(s) shall have access to its own me- ter(s) and heater(s) which shall not require entry ttirough another unit. � - (B) Each unit shall have its own panel, or access thereto, for all electrical circuits which serve the unit. (4) Private Storage Space. Each unit shall have at least two hundred (200) cubic feet of enclosed, weather-proofed, and lockable private storage space in addition to guest, linen, pantry and clothes closets cus- tomarily provided. Such space may be provided in any location approved by the planning commission, but sha11 not be divided into two (2) or more locafions: In case§ where the developer can demonstrate that this standard cannot reasonably be met, this standazd may be modified by the planning commission. (5)' l;aundry Facilities in Residential Projects. For residential projects, either a laundry area in each unit or common laundry areas shall be provided; provided such facilities shall consist of not less than one automatic washer and dryer for each common five units or fraction thereof. Iri such cases where the developer can demon- strate 4hat this standard cannot reasoriably be met, this standard may be modified by the planning commission. (6) Laridscape lvlaintenance. Ali landscaping shall be restored or replanted as necessary taking into consid- eration shade and sun patterns on the site and shall be ir- rigated and maintained to achieve a high degree of ap-; . pearance and quality; front setback landscaping may be 50% to provide for'an on-site delivery area and,_with a' special permit, landscaping may be reduced to 45% of the front setback if a circular driveway is provided; if the fronf setback is' altered to provide on-site parking for de- liveryVehicles or to provide a circular driveway, the front setback shall be relandscaped with the emphasis on planting large scale and more vertical plant material which wi11 frame and screen the view of the structure from the street and turf and ground cover areas in the front setback shall be minimized. (7) Condition of Equipment and Appliances. The de- veloper shall provide written certification to the buyer of each unit at the close of escFow that any dishwashers, garbage disposals, stoves, refrigerators,. hot water tanks, air conditioners and any other major appliances that are provided are in operable working condition as of the ciose of escrow. At such time as the homeowners asso- ciation takes over managemenf of the development, the developer shall provide written certification to the asso- ciation that any pool and pool equipment (filter, pumps, chlorinator) and any appliances and mechanical equip- ment to be owned in common by the association is in op- erable working condition. (8) Refurbishing and.Restoration. All main build- ings, structures, fences, patio enclosures,. carports, acces- sory buildings, sidewalks, driveways, laridscaped areas and additional elements as required by the Planning De- partment shall be refurbished and restored as necessary to achieve a high degree of appearance, quality and safety. (1707 § 2, Amended, AS/OSl2003; 1206 § 2, Added, OS/04/1981) 26.32.085 Minimum Requirements. Except as otherwise provided by law, in approving or conditionally approving any condominium project, the following shall be required: (a) Parking. (1) For multiple family residential condominiums, there shall be off-street parking as required by chapter 25.70 of this code and at least one parking space shall be in the ownership of each residential unit. No on-site parking spaces shall be rented or leased to any on- or of� site person. Coinpact parking spaces sha11 be ailowed in residential condominium development in the foltowing ratio: Required Parking Spaces . Allowable Compact Spaces i-10 1 10-20 2 Over 20 . . 3 (2) On-site guest parking spaces shall be provided for all residential condominium and cooperative devel- opments. Guest parking spaces shall be held in common ownership, shalt not be rented or assigned to residents or non-residents, and shall not be sold or transfened except with the sale of all units as a single enfity. Guest parking spaces may be designed to compact standards as defined in chapter 25.70. Guest parking spaces shall be provided in residential condominium and cooperative develop- ment in the following ratio: March 2004 (26.32) 4 City of Burlingame26.32.085 �-, ,J Number of Dwelling Units Req. Guest Parking Spaces � 2 to 4 units 1 5-15 units 2 15 or more 3 •(3) All residentiai condominium developments shall provide an area for on-site deliveries. (4) For commercial and industrial condominiums, there shall be offstreet parking as required by chapter 25.70, which may include compact parking as allowed in chapter 25J0. (5) Parking requirements compliant with the Ameri- can Disabilities Act shall be provided on site as required by the CaIifornia Building Standards Code as amended by this code.. (b) Access, vehicular driveways, and parking areas. (1) All private streets, driveways, and pazldng areas shall be improved and constructed with a structura} sec- � tion in accordance with city standards. They shall be de- signed and maintained to insure access for municipal services to any dwelling unit therein. (2) Onty temporary parking for service vehicles shall be allowed in the driveway between the front property line and the face of the building. Calculation of private open space and common open space at ground level shall not include any vehicular driveways or parking areas. (c) Side Setback Requirements. Side setbacks shall be five (5) feet minimum or greater as deter�r►ined by the zoning requirements for multiple family or commercial development, as applicable, as provided in title 25. (d) Conditions, Covenants and Restrictions.4gree- ments. Conditions, covenants and restrictions agree- ments shall contain, but not be limited to, adequate pro- visions for maintenance, repair and upkeep Qf all struc- tures, site landscaping and other on-site improvements; provisions that in the event of destruction or abolish- ment,. reconstruction shall be in accordance with codes in effect at the time of such reconstruction; and provisions for dedication of land or establishment of easements for street widening or other public purpose. Covenants, conditions and restrictions shall describe: powers, duties, rights and obligations set forth in Civil Code section 1355; the proposed form of owners' association; and suggested by-laws, maintenance agreements, use restric- tions, and special funds to cover emergency repairs; and require and enforce that on-site parking spaces be owned or assigned to condominium owners or held in common ownership by the condominium association shall be used only by bicycles or currently registered and operable ma tor vehictes as defined by the Vehicle Code. ' - (e) Landscaping and Open Space Standards. (1) Front setback landscaping for residentiat condo- minium or cooperative development. Landscaping is re- quired between the front property line and face of the building equal to and not less than fifty percent (50%) of the lot area within the required &ont setback. Emphasis should be placed on minimizing turf and ground cover areas and on planting larger scale and more vertical plant material which will frame and screen the view of the structure from the street. If a circular drive is provided a special permit may be reyuested to reduce the required front setback landscaping to forty-five percent (45%) of the lot area within. the required front setback. (2) Site landscaping shall be suitabie for the specific sun/shade environment of the lot. � (3) Private open space for residential condominium or cooperative development. Private open space shall be provided for each unit and shall be contiguous and di- rectly accessible to each unit. Private open space may be paved or landscaped and shall be screened or fenced for the privacy of the residential unit when located within fouc (4) feet of established grade. Decks and bal- conies when designated for outdoor use may be used ta satisfy this requirement. The following minimum stan- dards for private open space shall apply: (A) Seventy-five (75) square feet for each ground floor unit with no dimension of the designated azea less than ten (]0) feet; (B) Seventy-five (75) sGuare feet for each unit above the ground floor with no dimension of a designated area less than three and one-half (3 1/2 ) feet. (4) Common open space for residential condomin- ium and cooperative development. In addition to private open space, open space accessible to or enjoyed by all project residents shall be provided at not less than one hundred (] 00) square feet per dwelling unit, with no di- mension of any designated common open space area to be less than fifteen (IS) feet. Such common areas may be designed for passiVe or active use, and include land- scaping or paving, provided such paving does not exceed fifty percent (50%) of the total required area. Ali such areas shall be at or within six (6) feet of established grade; roof top areas shali not qualify as common open space. (5) Common open space for commercia] and indus- trial condominium and cooperative developments. Common open space shall be provided as required by the zoning district requirements based on t}ie location of the development. (� Project Plans and Submittals. Project plans shall indicate accessibility for owners, guests, employees and customers to parking, storage, recreation and service ar- eas; separation between living units and along property . lines; provisions for security; orientation with respect to `. surroundingbuildings and land uses; the location and type of utilities, building services and separate facilities for individual units and access easements to make repairs including:. , . . (26.32) 5 March 2004 City of Burlingame (1) Separate gas and electric meters and separate wa- ter shutoff valves; individual residential unit climate con- trols and any proposed climate zones (based on types of unit uses) for non-residential condorninium project§; (2) Shock mounting of inechanical equipment to re- duce sound transfer; (3) Ftexible connectors for electrical and plumbing � connections; ' " (4) Sound levels shalt satisfy adopted noise element criteria and all State standards; . (5) Other reports may be required by the city as a condition for approving a condominium permit including an economic report, social impact of relocation proce- dures; report of structura7 condition; report on'building compliance with all building, fire and zoning codes for proposed uses; certificate of occupancy; and sufficient additional information prepared liy licensed profession- als to evaluate the soundness of the conversion proposed project. 1707 § 2, Added, 05/OS/2003) 2632.090 Hearing. At the time of the hearing on the tentative map, the planning commission shall also hold a hearing on the conversion pemut. Notice of the hearing shall be given to all tenants of the proposed conversion and'posted on the property. (1707 § 2, Amended, O5I05/20U3; 1206 § 2 (part), Added, OS/04/1981) -� 2632.100 Hearing consideraiions. Atthe hearing on the application for conversion to condominiums, the planning comrrrission shall consider the following: (a) The opinions of the tenants of the: project as to whether the proposed conversion protects their interests; (b) Whether or not the amount and iinpact of the dis- piacement of tenants, if the conversion is approved, ' would be detrimental to the heahh; safety or general rvel- fare of the community; ' (c) The role that the commercial, industrial, office or apartment structure ptays in the existing rental inaiket for that use and whether this role is substantially altered by � the proposed conversion in the,light of the tenant protec- tion provisions in this code. Particular emphasis should be p}aced on the evaluation of rental structures to deter- mine if the existing building is serving low and moderate income tenants, or special groups of tenants such as eld- eriy or handicapped; (d) If applicable; whether or not lower cost home ownership opportunities will be in- creased by the conversion of apartments'to condomini- ' ums, stock cooperatives or community apartments; and (e) V1!,hether tenants will have substantial di�culty in obtaining comparably priced facilities: ' (1707 § 2, Amended, OS/OS/2003; 1206 § 2(part),'` Added, OS/04/1981) 26.32.110 Fiadings. The planning commission shall not issue a permit for condorrunium conversion unless the planning commis- sion finds that: (a) All provisions of this chapter are met; (b} The proposed conversion is consistent with the city's general plari; (c) The proposed conVersion wiil conform to this code and other applicable code provisions, if any, in ef- fect at the time of tentative map approval, except as oth- erwise provided in this chapter or specifically excepted by the planning commission; and (d) The overall design and physical condition of the condominium conversion achieves a high degree of ap- pearance, quality, and safety. (1707 § 2, Amended, OS/OS/2003; 1206 § 2, Added, OS/04/1981) �.. _ � " ..�i' March 2004 (26.32) 6 12/20/2005 08:31 6506963790 C.Iry c�r r�L�RLlNG,�Mr rt�nNrriNp UGPAI��tMIIrrT SOi PRIMIt058 ROAU r(650) 5S8•72sb r(G,SB) G96-3790 PAGE 21/23 fi � aAM� �P�'�.,�CATT(JN '�'a TH� PL.A.N�V'�'1�T� CUMM�SS�(]N ���Mn11NMM16'� Ty�e o� ap�pli�s�t�on: Design kZcview� Condi1;io�taI Us� �'exrnit _. V�riance Sp�ei�] Perrr�it Otl�e.r... t�ar.c�i Number.: � Project �►ddress.�� f� �c��A-DL/� � ,_ „---- .._.,_ AP�'LTCANT P�4�ERTY l7�VNER �c Na�nc: � Narne:=��a(�?�S"r e�i''� Address:. � ,�.c�.dx�ss: f •U, �o�c �S� Ci�,�/�t�.te%Zip: �..��11// ,� 9�� Ci1,y/State/7ip.: � t�t � f cr� C� y`�0.� C� Pl�ai�� (w}: �O —. ��% ��� Pltone (w): � �SO � �� .3 -' O} �'� c.�►i. c�: �a � �.��.. ���: c�� a,z�c�rr�r�c�r�nEsr�r�r � � ► rr���• f � Address: City/St�te/7x E G�" ��� Ptioiye (w): ,� -� ,y �% (��)� , , --- (�: �� �5�=--��L/��. PXease i�n.dxca.�e vvith a� astieriak'� �he contact pexso�n fnr, th�s �axoject. R�C����� DEC 2 i Z005 CITY OF BURLINGAME PLANNING DEPT. r. uo,n��c� ti�;sc���zoN �2P�'�/�'�AC 11 +. +A.bA,Vi'�/SxGN.A,�URE: I he;re certi der. pena iy �ofpex�uzy that tt�e ix►fonna�ion give�� hcrein rs tzu� and conect t e m z�owl � c and be�xef A,pplic�lnt's si�;zza.t�ire: _._ �7ate: � Z�Ct�t►w a�out the prnposed a.p��xca.ttiol� and hereby a.u�liorize t11e aUov'e �pplicaxz1: to submit ikuis applicltion to the P1�.1�;�i;�� Cb� ssiqn, , Property owner°a aagn.atu.ze: ` T7atc: � �� rcnrr.rRM G�.pI�CA Il�on -�p�/ G� �� � r a,,, �'J^ -�..n i -�- G�p�'�.�oinn�✓I�vl�v� Gp/1JCV.SIDn �MI�-�' p-h-t-�' cg/ �J a.re�► o � 5-t. DoJ 1 l c� i � . V Konstantinos Dokos P.O. Box 125 Millbrae, CA 94030 O�ce (650) 873-0789 Fax (650) 952-5480 February 24, 2006. To: The Planning Commission City of Burlingame, CA 94010 RECEIVED MAR - 6 2006 CITY OF BURLINGAME PIANNING DEPT. Re: 819-821 Cowan Road, Burlingame, CA 94010 Honorable Commissioners' I wanted to take a moment and explain why I have decided to convert my office warehouse building into 5 individual office/warehouse condominiums. Initially my intent and cost estimates were predicated in leasing the units to 5 individual tenants. Unfortunately, current market rental conditions and cost overruns of the project due to time, price/inflationary escalations in materials and labor have convinced me that it would be best to offer the 5 units as individual office/warehouse condominiums. Currently the market has a high demand for owner/user properties especially office/warehouse spaces. I believe that based on the excellent design, configuration, new construction, and prestigious Burlingame location that from and owner/user stand point these units will be able to attract good quality businesses that will overall increase city revenue and make this a successful project for everyone. Sincerely onstantinos okos Owner/Builder 12/20/2005 08:31 6506963790 �iTY �F �URLtNc;AMF. PLANNfNG DePARTMCNT 501 PRiMROSL Rc7Ar� P(G50) 558�7250 a(fi50) G4G 3790 ;k�_::.:e;� ;� ,. ,����� ; � ' � � ; �C�.`�'X ���`��A�1��. � � � . ' ' ` . �� ���3���;.� r �.. � � � �� � ' � � . :�1' .�:'�,�:�[���'������:.�����`�A�'��i�T��� iF.�, "_'_"_....n.�.L!..�.x..�..._...._ ...._.4. 1.. .�.... .•j.. i. . . ... • �. .. ... PAGE 22/23 ��V�O 1�9 �� DEC 2 7 2005 C�TY OF BURLINGAME PLANNING DEPT. Th� �'lannin� Cornmissio:n is ree�uired by la.w to m.ake :�ndingg as dc�ned by the City's Qrdin�nce {Cade Sectzon: 25.52.020). '.Your ayisw�rs to tl�e %1lowing ques�iorrq car� assist the ����uing Corr�ia�.ission in x�.a.lcin� the dccision as to whether the ��taclin�s can Ue r.�ade �'or yattr requesi. P1e�rtse typc or vaiite �aGa.tly� i.r, zaak. Refer to t��.c Uacic o:f: thia fo� f'or assista.nce wit1�, tk�ese qucstiar7g. �eplain wl�y tl�e,�rn,�tos�d use at the,�roposed. lvcatia� wxlJ rzat. lie de�ci��r.�r�tal or i�:jtrrior�s �`o prn��rt.y or i�zproy�er�ac�r�'s zn the t�icini�y vz� t.o�prahlic r ealt.h.,�safe,ty, ger���al welfa.re� or cor�yi�,xience. G� I� ll��/� Cj r`.�F�[�!�/�'so �� fC�G� /.'S GYl%� ��ll%.C��-�jrt/�% '�, � E���'�o 2. .XaTow ��zlX f1'ie pre��s�d reS� ��e located aiad conducted iia accor�la.�ce �vi#/z tl�e �3u,rlr',�,�a.t�r.e Gew�epczi.i�lar� arxd 7orz��a� Urri�r�qr�ce? U.�� /-S' C��S'iS�-iU%��l` �c ��d����� ��t/�P�Prf-��L ��� � �`� !� � �`�c�i� �� ��i`Y��/�- � �i� j� '�il��� l�r l� �i�jiil�iS�it�� � � 3. .F�(o�� wi�,l, tl:e prop�sed prnject be conx,�atible wi,f.1� the aest.h�t.ics, r�zass, br�lk anai cha,rc�cter oj``t./xe rxr'str'rt,,g artd. pr�ter�tiaZ uses ort adjoir�ing prn,�verties ir� the gea�eral uicinity? �/� ��,,,.� ��� �l� r C`3�'J��� j�filC�G�/ ��� � i� ���� o . ��� �� � c�rn.r•Rn� M E M O R A N D U M CITY OF BURLINGAME , CITY ATTORNEY DATE: February 3, 2006 RECEIVED TO: Planning Staff FEB� - 4 2006 � CITY OF BURLINQAHIE FROM: Larry E. Anderson, City Attorney PLANNINQ DEPT. RE : Draft CC&R's for 819 Cowan Road Commercial Condominiums I have reviewed the draft CC&R's printed on 010304. There is one change that should be made. These draft CC&R's do an excellent job of covering the issues of concern to this office. I have one suggestion for the applicant and the applicant's attorney regarding section 3.5, page 8: we have found that the use of "service dogs" is now a protected right under ADA, so consideration might be given to changing this section from guide dogs to service dogs. This memorandum should not be interpreted as making any determination as to whether the CC&R's conform to State or Federal law or are adequate in any particular. As I understand it, the project is still undergoing review at this time. If there are any conditions placed on the development by the City that require recordation or disclosure to purchasers, I assume that revised CC&R's will be submitted to the City and this office. This is particularly important for any maintenance obligations. Project Comments Date: To: From: 12/28/2005 af City Engineer ❑ Chief Building Official ❑ City Arborist ❑ City Attorney ❑ Recycling Specialist ❑ Fire Marshal ❑ NPDES Coordinator Planning Staff Subject: Request for condominium conversion permit for a five-unit office/warehouse building at 819 Cowan Road, zoned IB (Inner Bayshore), APN: 024-401-560 Staff Review: 1 /03/2006 1. Proposed condominium map does not currently show the second level. Submit map with second level shown in plan. 2. Stairways at the four corners of the building appear to be used exclusively by the individual units. Provide explanation for the designation of the stairways as common areas. 3. In addition to the map, a plan showing the proposed utilities for the building is required. Only one sewer lateral and one water meter are allowed for the development. 4. The sidewalk, driveway, curb and gutter shall be replaced entirely with new. An encroachment permit from the Public works Department — Engineering Division is required for this work. 5. Provide basis of bearing for the map. 6. The conditions, covenants and restrictions for this map must be approved by the City Attorney and conform to all approval conditions and City codes. Reviewed by: V V Date: 1/30/2006 Date: Project Comments 12/28/2005 To: ❑ City Engineer ❑ Chief Building Official ❑ City Arborist ❑ City Attorney From: Planning Staff ❑ Recycling Specialist d Fire Marshal ❑ NPDES Coordinator Subject: Request for condominium conversion permit for a five-unit office/warehouse building at 819 Cowan Road, zoned IB (Inner Bayshore), APN: 024-401-560 Staff Review: 1 /03/2006 *A deed restriction is required for coordination of infrastructure items specific to fire and life safety such as: 1. Fire Extinguishers Maintenance and Service 2. Fire Sprinkler System Maintenance, Service, and Repair. 3. Fire Alarm Maintenance, Service, and Repair. *A conditional use restricting occupancy types to Group B and Group S-2 occupancies. Reviewed by: ���/����� Date: y/�-�� 9` Project Comments 12/28/2005 Date: To: ❑ City Engineer X Chief Building Official ❑ City Arborist ❑ City Attorney Planning Staff From: Subject: Request for condominium office/warehouse building at Bayshore), APN: 024-40'I-560 Staff Review: 1/03/2006 d Recycling Specialist ❑ Fire Marshal ❑ NPDES Coordinator conversion permit for a five-unit 819 Cowan Road, zoned IB (Inner Page 1 of 2 1) All construction must comply with the 2001 California Building Codes (CBC), the Burlingame Municipal and Zoning Codes, and all other State and Federal requirements. 2) Provide fully dimensioned plans. 3} Provide a title block on the plans that includes the name of the owner(s) and the name, address, and phone number of the project designer. 4) Comply with the new, 2005 California Energy Efficiency Standards for non- residential buildings. Go to http://www.enerqy.ca.qovltitle24 for publications and details. 5) Exterior bearing and/or non-bearing walts must be one hour if less than 20 feet firom the property line. Openings are not allowed within 5 feet and must be protected within 10 feet of the property line. (See CBC Table 5-A.) 6) Provide guardrails at all landings. NOTE: All landings more than 3Q" in heighfi at any point are considered in calculating the allowable floor area. Consult the Planning Department for details if your project entails landings more than 30" in height. 7) Provide handrails at all stairs where there are more than four risers. 8) Provide lighting at all exterior landings. 9) On your plans provide a table that includes the following: a. Occupancy group for each area of the building b. Type of construction c. Allowable area d. Proposed area e. Allowable height f. Proposed height g. Allowable area increases taken h. Exterior wall and openina protection � A� Project Comments Staff Review: 1/03/2006 Page 2 of 2 i. Allowable ii. Proposed b. Indicate sprinklered or non-sprinklered 10)Show the dimensions to adjacent structures 11)Show the distances to property lines or to assumed property lines 12)Provide an exit plan showing the paths of travel 13)Specify the total number of parking spaces on site � 4)Show compliance with all accessibility regulations found in the 2001 CBC, Chapter 11, for existing buildings including: a. Accessible paths of travel b. Accessible countertops c. Accessible bathrooms d. Accessible parking 15)Ilustrate compliance with the minimum plumbing fixture requirements described in the 2001 CBC Appendix Chapter 29, Table A-29-A. Date: To: From: 12/28/2005 � City Engineer X Chief Building Official ❑ City Arborist ❑ City Attorney CI Recycling Specialist ❑ Fire Marshal ❑ NPDES Coordinator Planning Staff Subject: Request for condominium conversian permit for a five-unit office/warehouse building at 819 Cowan Road, zoned IB (Inner Bayshore), APN: 024-401-560 Reviewed by: Date: (/�/o Project Comments Date: To: From: 12/28/2005 ❑ City Engineer ❑ Chief Building Official d City Arborist ❑ City Attorney Planning Staff X Recycling Specialist ❑ Fire Marshal ❑ NPDES Coordinator Subject: Request for condominium conversion permit for a five-unit office/warehouse building at 819 Cowan Road, zoned IB (Inner Bayshore), APN: 024-401-560 Staff Review: 1/03/2006 Applicant shall submit a Recycling and Waste Reduction Plan for approval, and pay a recycling deposit for this and all covered projects prior to construction or permitting. Reviewed by: Date: � � � � v � Project Comments Date: 12/28/2005 To: � City Engineer � Chief Building Official � City Arborist � City Attorney From: Planning Staff � Recycling Specialist � Fire Marshal � NPDES Coordinator � �. Subject: Request for condominium conversion permit for a five-unit office/warehouse building at 819 Cowan Road, zoned IB (Inner Bayshore), APN: 024-401-560 Staff Review: 1/03/2006 Please ensure all contractors and subcontractors comply with the City's stormwater NPDES permit and implement the conditions of approval relating to stormwater pollution prevention program as listed on Plan Sheet C.1, submitted to the Planning Department on 12/27/05. Reviewed by: �,� Date: �l ���5 ' �a M b' � /�/�ONESTOPD_ESIGN From: OneStopDesign, Inc. Design and Engineering Services 3566 Beard Road Fremont, CA 94555 510-794-7993 (voice), 510-794-4178 (fax) ��C����� DEC 2 7 2005 CITY OF BURLINGAME PLANNING DEPT. 26.32.40 Phvsical Elements Report for 819 Cowan Road Condominium Conversion The entire Project is being built per current California Building; and Fire Codes. As of the date of this Submission, the building is currently under construction, with the following components being included: �a� 1. The building is being constructed with one-hour construction throughout. 2. Resilient channel and foaming of penetrations will be installed per USG specifications included. 3. 4. 6. 7. 8. (b) (c) (d) (e) �� �g) (h) Each unit will be separately sprinklered for fire. Each unit will be separately wired and metered for electricity, phone, IT, cable, etc. Each unit will be separately plumbed and metered for water. Each unit will be independently heated, and where applicable, cooled, per Title-24. All interior walls and floors will be insulated for energy efficiency and sound. All new glazing will be energy compliant with Title-24. As there are no existing party walls etc., the building is being constructed with 1-hour construction and methods of acoustical engineering per USG standards included. No report on utilities is necessary, as the current building permit has included separate utilities for each unit. ' Current Planning Commission approved parking plan will remain unchanged. Structural Calculations are included in the current Building Department approved plans/: There is a current Soils Report on file for this Project. No repairs are necessary as the Project is all new construction. All easements, utilities, and off-site requirements are currently on file, and reflected in these documents being submitted. � 26.32.50 Additional Submittals (a) (b) The Project's current Owner will submit Draft CC&R's at a later date. Demographics: 1. Unit Breakdowns: Each unit has a lower warehouse area with two bathrooms, that are ADA accessible. The upper floor of each unit contains open office space with access to common ADA restrooms and a common elevator sized per City of Burlingame Fire Department specs. The individual unit breakdowns are as follows: a. Unit 1: Upper floor = 2118 sq. ft. Lower floor = 2475 sa. ft. Total = 4593 sq. ft. b. Unit 2: Upper floor = 1879 sq. ft. Lower floor = 2637 sq. ft. Total = 4516 sq. ft. c. Unit 3: Upper floor = 1717 sq. ft. Lower floor = 1894 sq. ft. Total = 3611 sq. ft. d. Unit 4: Upper floor = 1740 sq. ft. Lower floor = 2637 sq. ft. Total = 4377 sq. ft. e. Unit 5: Upper floor = 2121 sq. ft. Lower floor = 2447 sq. ft. Total = 4568 sq. ft. f. Common areas: (Building only, NIC decks) Upper floor = 1580 sq. ft. Lower floor = 1478 sq. ft. Total = 2058 sq. ft. (c) (d) (e) 2. There is no rental rate history for this Project, as the use and construction are new. 3. There is no vacancy rate for this Project. The prior use of the building showed it to be leased full-time for the last 10 years+. 4. N/A 5. Sales prices for the Units is unknown at this time. 6. Common Fees will be fixed at the time of filing of the Draft CC&R's. 7. Owner is financing his own Project. 8. No tenants currently occupy this Project, as it is under construction. There axe no current tenants. There are no current tenants. This section is for Planning Staff to detertnine. A 26.32.060 Acceptance of reports. Owner agrees to this requirement. 26.32.070 Couy to Buyers. Owner agrees to this requirement. 26.32.080 Phvsical Standards for condominium conversion. (a) Adequate Physical Conditions. Owner agrees to finish the Project according to the Burlingame Municipal Code, including all building and fire codes. No corrective work is necessary, as this is all new construction. (b) Speczfic Physical Standards. (1) Fire Prevention — Smoke Detectors and Sprinklers. Each Unit will be provided with a separate fire sprinkler system designed by a licensed C-16 subcontractor, and approved detectors. (2) Sound Transmission. (A) Shock Mounting of Mechanical Equipment. All permanent mechanical equipment, such as motors, compressors, pumps, etc. which are determined to be a source of structural vibration or structure-borne noise shall be shock mounted with inertia blocks or bases and/or vibration isolators in a manner approved by the chief building official. (B) Noise Standards. The current Project will conform to all exterior and interior sound transmission standards of the CBC and the City's General Plan. Additionally, the USG construction methods attached to this submission will apply where possible. (3) Utility Metering. (A) Each Unit shall be separately metered for Gas, Electricity, and water. Additionally each Unit will be provided with separate runs for phone, cable, and IT wiring. (B) Each Unit will be provided with separate interior subpanels per electrical plan submitted. (4) Private Storage Space. As these are commercial units, with large warehouse areas, there should not be a storage space issue. (5) Laundry Facilities. N/A (6) Landscape Maintenance. A monthly landscape fee shall be attached to each Unit's Common area fee. See landscape plan submitted. (7) Condition of Equipment and Appliances. All mechanical equipment will be new and specified when units are sold. (8) Refurbishing and Restoration. Building shall be finished according to approval by Planning Commission, and conditions applied. 26.32.85 Minimum Requirements. (a) Parking. See Parking Plan approved by Planning Commission. (b) Access, vehicular driveways, and parking areas. See site plan approved by Planning Commission. See Parking Plan approved by Planning Commission. (c) Side setback requirements. See approved Site Plan. (d) Conditions, Covenants and Restrictions Agreements. See Draft CC&R's submitted by Owner. (e) Landscaping and Open Space Requirements. See Sheet L.2 (Landscape plan) submitted with this application. L� C' �� 26.32.100 (a) (b) (c) (d) (e) 26.32.110 (a) �) (c) (d) Project Plans and Submittals. Within the plans submitted, the following are included. (1) Separate gas and electric meters and separate water shutoff valves; individual climatic controls, zoned per final Purchaser requirements. (2) All mechanical equipment will be shock mounted to reduce sound transfer. (3) Flexible connectors for electrical and plumbing connections will be included. (4) Sound levels shall satisfy all State standards and the USG Acoustical Assemblies data supplied. (5) We will provide any additional reports required by the City. Hearing Considerations. There are no current tenants. As this is a commercial conversion, there are no issues that would be detrimental to the health, safety, or general welfare of the community. This section should not apply, again, due to the commercial nature of this application, and the fact that it a commercial conversion. This section should not apply, again, due to the commercial nature of this application, and the fact that it a commercial conversion. This section should not apply, again, due to the commercial nature of this application, and the fact that it a commercial conversion. Findings. To the best of our knowledge, all provisions for conversion and the filing of the subdivision map have been met. As this Project has a recent prior approval of the Planning Commission, and after conversion, the use will remain unchanged, we feel the conversion is consistent with the City's General Plan. The proposed conversion will conform to all Codes and Conditions required by the City. The prior submitted and approved design, along with Conditions put forth by the City will remain unchanged. c� A • ^ �� V ����� . cous lca DEC 2 7 2005 � K Def initions Lilce most specialized fields, the science of acoustics has a language all its own. Some of the most important terms and concepts to be familiar with include: Ahsorption Percentage of sountl waves that a material transforms into heat energy antl thereby tloes not reflect back into the space. Articulation index (Af) A measurement of how well speech can be untlerstootl in a space. High AI is desirable in spaces such as autlitoriums and theaters and can be achieved with a combination of materials antl tlesign details that strategically reflect antl absorb sound. Reducetl AI is desirable for spaces such as open offices, where many people must work intlependently, antl in financial and healthcare facilities, which are subject to fetleral privacy rules; sountl masking can be used to retluce AI (see the next page for more information). Ceiling Attenuatian A measurement of the ability of a ceiling panel to block the travel of sountl from an enclosed room up into the plenum Ciass (CAC) and down to adjacent spaces. High-CAC ceiling panels can provide this type of sountl control, increasing speech privacy in private spaces and reducing distractions to those outside. Conductivity The ability of a material to transmit sountl waves. In addition to moving through air, sountl waves can travel even more easily through many solitl objects. For example, sountl waves move through air (70 °� at just 1,128 feet per secontl but travel about 10 times faster (11,700 feet per seconc� through wood, and faster still (18,000 feet per second) through steel. Therefore, designers must consider not only airborne sound, such as voices and ringing telephones, but aiso structure-borne sound created by footfall, doors opening and closing, and builtling systems such as elevator machinery and HVAC equipment. Diffractinn The bentling of sound waves around objects or through smail spaces antl openings with little energy loss. Spaces arountl doors, floor tracks, electrical boxes, antl conduit and HVAC tlucting are typical channels for sound diffraction. These spaces should be filletl with acoustical sealant to prevent unwantetl sountl from intrutling into atljacent spaces. Flanking Paihs Small gaps antl openings around doors, floor tracks, electrical boxes, and contluit antl HVAC tlucting that allow sound to pass through if not filletl with acoustical sealant. Also called "leaking paths." Impact isolatinn Measurement of the ability of a floor/ceiling assembly to isolate sountl from footfall and other impact sources, Ciass {IIG} reducing the intrusion of noise into rooms tlirectiy below. Ptoise Reduction Measurement of the ability of a material such as an acoustical ceiling panel to absorb sountl energy in the frequency Goefficient (NRCj range of 250 Hz to 2,000 Hz (see "pitch" for more information). High-NRC ceiling panels provide this type of sound control, which is important for large spaces such as open-plan offices. 5 USG Acoustical Assemblies 4' Def initions Pitch The oscillation rate of a sountl wave, which travels as a small pressure change alternating above and below the static (at rest) state of the contlucting material. Each cycle of compression antl re-expansion is a wave. The number of waves occurring per secontl is the frequency, which is measured as hertr (Hz); one Hz equals one cycle per secontl. A sound's pitch rises as its frequency increases. The human ear can discern sounds ranging from approximately 20 Hz to 20,000 Hz. Human speech ranges between 125 Hz antl 4,000 Hz. Reflect9an The bouncing of sountl waves off any hard, smooth wall, ceiling or floor surface, making them autlible beyond the immetliate area of the source. The shape of surfaces also affects where sound may travel. Concave surfaces concentrate or focus sound, while convex surfaces can disperse sound in multiple directions. Reverberatian Sound that persists in an enclosed space by reflecting off surtaces in the room. 5ound Masking A carefully engineered sound spectrum similar to that of softly blowing air, which is amplifietl through speakers to raise the ambient sountl level, "masking" conversations antl background noise. In enclosetl rooms, sountl masking increases speech privacy by lowering the articulation index, preventing conversations from being overheartl. S�und Transmission Measurement of the ability of a wall or floor assembly to isolate airborne sound antl prevent it from passing from one Elass (STC) side to the other. Transmissinn The passage of sountl waves from its source, through a vibrating medium, and to a listener. "Airborne sountl" passes through a space by vibrating the air. "Structure-bome sountl" travels through wali partitions, ceilings antl floor/ceiling assemblies. idolume The loudness of a sound—how much the amplitude of a sound wave exceetls the static pressure of the conducting medium—as measuretl in decibels (tl6). The higher the tlecibel level, the greater the volume. Noise from a jet plane has an amplitude of 140 tl6, while a human whisper is approximately 20 dB. Sound in a typical office environment reaches 40 d6 to 60 tlB. Volume doubles with each 10 d6 increase in sound energy. 6 USG Acousticai Assemblies v ti Components Acoustically-rated systems have been comprehensively tested for sound control. Substitution of any components is not recommended or supported by USG. Refer to the material safety data sheet for each product for complete health and safety information. Cei#ings USG Acoustical Ceiling Panels —Available with high NRC, CAC, antl combination NRC/CAC ratings —Provide stylish antl effective sountl control in a full range of commercial applications including retail, healthcare, hospitality, etlucational antl office settings —Combine top-rated acoustical performance with durability, high light reflectance and a range of textures to complement any decor —Many feature the ClimaPlus Non-Sag Warranty —Cast ceiling panels provitle unparalieled strength antl integral color to mask nicks and scratches for long service life antl low lifecycle costs —Select panels provide antimicrobial treatment for true protection against moltl For more information see the following brochures: Ceiling Systems Binder Ceiling Systems Desktop Reference SC2392 SC2000 Lexcoae� SaecrRa� Sound Masking —Covers ambient noise in large spaces so potential distractions are less intrusive —Enhances speech privacy in private offices by preventing conversations from being overheard outsitle —Adds acoustical balance to exceptionally quiet environments —Each unit is powered by 16/18 volts AC and inclutles a self-containetl noise generator, audio amplifier, loudspeaker, antl power supply unit in an aluminum enclosure —Supports an optional paging system , —Allows paging antl masking volume to be adjusted intlepentlently, and additional central control capabilities are available For more information see the following brochures: The Acoustics Solution SC2411 Will You Achieve H/PAA Compliance? SC2412 7 U&G Acaus�ica8 Assemblies ,� Components Watis and Partitions SHeerRoc� Brand Gypsum Panels —Available in thicknesses of 1/4" to 3/4" for assembling interior partitions with one or more layers per side for effective sountl control in any application —Steel-framed resilient partition systems with sound attenuation fire blanket (SAFB) in the partition cavity can achieve up to 65 STC with multi-layer designs, up to 63 STC with double-layer tlesigns, and up to 56 STC with single-layer tlesigns —Wootl-frametl resilient partition systems with SAFB can achieve up to 59 STC with double-layer designs antl up to 50 STC with single-layer tlesigns —Have achieved up to 4-hr. fire-resistance ratings with 3/4" U�TRacoo� Core panels in steel-framed partition assembiies For more fnformation see the following brochures: Moisture-ResisfantAssemblies AestheticAssemblies SA932 SA933 SHE�rRocK Gypsum Panels Submittal Sheet WB1473 USG Area Separation Walls —Achieve up to 60 STC —Offer 2-hr. and 3-hr. fire-resistance ratings; comply with fire-resistance requirements under evaluation reports of UL U336 —Weigh at least 50% less than masonry walls, allowing faster, easier installation For more information see the following brochures: Area Separation Wal/ Systems Area Separation Wall Submittal Sheet SA925 WB2129 SHe�rRacK Shaft Wall Systems —Tested systems achieve up to 58 STC —Have achievetl up to 4-hr. fire-resistance ratings with multi-layer designs (UL U415) —Oscillation testetl to 1 million cycles to ensure structural performance —Feature panels with water-resistant facings antl/or moltl-resistant paper antl a water-resistant core to help minimize the risk of moisture damage For more information see the following brochures: Shaft Wall Systems SHe�rRocK Gypsum Liner Paneis Submittal Sheet SA926 W62278 8 O5G Acaustical Assembiies C omp onents Flonr/Csiling AssembEies Leve�RocK� Floor Underlayment —Low-profile leveling gypsum concrete system increases IIC ratings by as much as 13 points when usetl with LEVELROCK'" SRB"' sound reduction board or SRM-25'" sound retluction mat —Improves sound control in nominal wootl-joist, engineered I-joist, open-web truss, and concrete floor systems —Provitles 1- antl 2-hr. fire-resistance ratings for wood-framed floor/ceiling assemblies, and 4-hr. ratings for precast concrete assemblies —Available in an unmatched range of compressive strengths from 2,500 to 8,000 psi For more information see the following brochures F/oor Underlayment Sysfems High-Strength F/ooring Solutions SA305 IG1503 SRM-25 Sound Reduction Mat —Low 1/4" profile allows use of the fuli range of flooring finish materials inclutling hardwootl, ceramic tile, and marble with smooth transitions between surtaces —Elevated on small nodes so less than 5% of surface area makes direct contact with the subfloor —Increases STC rating by 4-7 points antl IIC rating by 8-13 points For more information see the following brochure: Leve�nocK SRM-25 Sound Reduction Mat Submittal Sheet IG1619 SRB Sound Reduction Board —Smooth, coatetl finish resists abrasion antl maintains tight tolerance —Just 3/8" thick; allows flexibility in choosing flooring materials —Increases STC rating by 2-3 points and IIC rating by 5-8 points For more information see the following brochure: Leve�RocK SRB Sound Reduction Board Submittal Sheet IG1523 10 USG Acoustica3 Assemblies ♦ • ♦ Performance Testing Testing provides a measurement of maximum performance potential achieved under controlled laboratory conditions. The actual ability of partitions and assemblies to control sound in real-life applications, however, depends on their design and the methods used to install them. Deviations from the detailing shown in this publication, substitution of components, or damage and improper repair or maintenance could severely reduce the acoustical performance of these installations. Testing Ntethods All USG protlucts antl systems untlergo exhaustive testing to ensure that they meet exacting stantlards. USG's protlucts are Classified as to fire resistance antl fire-hazartl properties. As part of this protocol, Underwriters Laboratories (UL) periotlically autlits protluction of these materiais to ensure compliance with necessary properties. UL is an intlependent, not-for-profit organization that has tested protlucts for public safety for over a century. Products are manufacturetl antl tested in accordance with recognizetl standards. ASTM International is one of the largest voluntary standartls development organizations in the worltl, antl is a trustetl source for technical standards for materials, protlucts, systems, antl services. %sting Resuits ASTM C423 Sountl Absorption antl Sountl Absorption Coefficients by the Reverberation Room Method measures Noise Reduction Coefficient (NRC). This rating represents the average of a given materiai's sound absorption coefficients at four frequencies from 250 Hz to 2000 Hz. ASTM E1414 Determination of Sountl Transmission Class by the Two-Room Methotl measures Ceiling Attenuation Class (CAC), the sound reduction in decibels provided between rooms with a sharetl ceiling and common plenum. This rating represents the average of the sound attenuation at four frequencies from 250 Hz to 2000 Hz. Acnu&tica( CBilings Panels ECLIPSE�" CL/MAPLUS FROSTM CLIMAPLUS ........................... HALCYONTM CLIMAPLUS ........................... M�wsW CunnaP�us NRC I CAC .70 35 ...................................................... .70 40 ...................................................... .90 30 ...................................................... .70 35 �AC Wiffl �ENCORE Sound Masking° 45 ........ . ........................ 50 ........ . ........................ 40 ........ . ........................ 45 11 USG Acoustica9 Assembiies .............................. .............................. .............................. ................................................... ................................... .................................. ............... Double-Layer U419, U454 63 ................................................... ................................... .................................. ............... Single-Layer U419, U451 56 ................................................... ...................................................................... ............... Double-Layer U334 Wootl/Resilient Channel 59 ................................................... ................................... .................................. ............... Single-Layer U311 50 USG Area Separation Walls UL D� U415 STC ( 39-58 Wall Type Solid SxeemocK Shaft Wall Sy: Nail Type Cavity Veneer Plaster Systems Framing Non-loadbearing Steel .................................... Non-loadbearing Steel/Resilient .................................... Wood .................................... Wood/Resilient Mineral Fiber Board UL Designs STC (Tested Assemblies) U411, U412, U419, 40-59 U435, U448, U455 ......................................................................... U419,U423,U440, 50-63 U451, U452, U453, U454 ......................................................................... U305,U314 34-46 .................................. ...................................... U311 49-52 MiconE 300 Board Micoee 160 Board Thickness STC NRC STG NRC 3/8" 24 .25 22 — ................................................... ................................... .................................. .................................. ............ 7/16" 24 .25-.30 — — ................................................... ................................... .................................. .................................. ............ 1/2" 25 .30-.35 24 .30-.40 ................................................... ...................................................................... .................................. ............ 5/8" 26 .30-.35 26 .30-.40 ................................................... ...................................................................... .................................. ............ 3/4" 28 .30-.35 26 .55-.60 Notes (a) L�Ncoae sound masking adtls the equivalent of 10 points of CAC by increasing ambient background sound by 10 d6. (b) Includes SAFB in the partition cavity. (c) Performance shown for perforatetl products. Performance Testing .......................................................................................................................................... ASTM E90 Stantlartl Test Method for Laboratory Measurement of Airborne Sountl Transmission Loss of Builtling Partitions antl Elements measures Sound Transmission Class (STC), the acoustical isolation provided by a barrier material or partition assembly. This rating represents the average of the sound attenuation between iwo spaces at four frequencies from 250 Hz to 2000 Hz. WaCis �nd P�rtitiEEns Sxe�eocK Brand Gypsum Panels Partition Type UL Designs Framing" Max. STC Multi-Layer U419, U455 Steel/Resilient Channel 65 UL D� U336 STC (Te: 46 to 60 12 U3G Acoustical Rssemblies .' Ffoor/Ceiiing Assembfies ASTM E492 Stantlard Test Method for Laboratory Measurement of Impact Sound Transmission Through Floor-Ceiling Assemblies Using the Tapping Machine tletermines Impact Isolation Class (IIC), the ability of a floor/ceiling assembly to isolate noise from footsteps antl other impact sources. This pertormance is testetl using a tapping machine that impacts the floor of a"source" room and measuring the amount of sound that comes through the ceiling of a"receiving" room locatetl directiy below, LeveuiocK Floor UnderlaymeM Sound Isolation System Framing Sound Barrier I-Joist SRM-25 Sound Retluction Mat I-Joist Vuss ................ .............................. SRB Sound Reduction Board ................ . ............................ SRM-25 Sound Reduction Mat Truss Floor Finish Carpet ..................... Sheet Vinyl ..................... Ceramic Tile ..................... Wood Laminate ..................... Wood Laminate ..................... Ceramic Tile ..................... Sheet Vinvl Ceramic Tile Sheet Vinyl......, Sheet IIC 77 .... ...................... 55-58 .... ...................... 54-56 .... ...................... 52-54 .... ...................... 61 .... ...................... 51 .... ...................... 54 .... . .................... 73 .... .5fi •' ............... .. . .. 55 .... . .................... 76 .... . .................... 48 STC 65 ....... ............... 60-64 ....... ............... 60-66 ....... ............... 60-64 ....... ............... 65 ....... ............... 65 ....... ............... 65 ....... . ............. 61 ....... .�i "........ .. . ... 61 ....... . ............. 58 ....... . ............. 58 13 USG Acoustice! Assemhlies 0 Legend Architectural Elements Architectural Elements � �� � � • � � �� � This legend contains the symbols C-H studs � Polystyrene used throughout the Architectural insulation Reference Library to represent various architectural elements. ...................... ....................... ............................................... ...................... ............ Profile and cross-section views are Z-furring —L Blanket shown where appropriate, along insulation with architectural matcrial symbols. ...................... ....................... ............................................... ...................... ............ Engineered R Solid wall joist Qfl � . .................... ............ Plywood Decking.......... ....................... ............................................... . .................... ............ Cement board Decking . .................... ....................... ............................................... Poured gypsum ...................... ....................... ............................................... Lath ...................... ....................... ............................................... Gypsum boartl :>...:;:.<.. :;.;, ..... .:.:..... .:.:.: ,,::.:..... ...................... ....................... ............................................... or plaster Waod truss -- . .................... ....................... ............................................... Veneer finish . .................... ....................... ............................................... `= Tile ...................... ....................... ............................................... Wood j0ist or stud � .................. ....................... .......................................... Concrete or ...................... ....................... ............................................... precast concrete Steel joist . .................... ....................... ............................................... or stud Ceiling panel ..................... ....................... ............................................... ...................... ....................... ............................................... Steel truss � � \\ // .................... ....................... ............................................... RC-1 channel ..�- ..................... ....................... ............................................... Furring channel L/- 14 USG Acoustisal Assamblies 0 A Partitions ........................................................ ��i<oc�cl. F�•a�rlec� � Loadbearing wt. 7 • 5/8" Sr+�ocK Brand Ra�cooe Core 34 USG-30-FT-G&H . •• �� Gypsum Panels or Fie�RocK Brand Panels Based on 16" stud spacing and _.,. :..::>,.:,:...:•...:.. _..>:.. �.,.: :..�.,.:: 4,�� , - 2r4 wood stud 16" or 24" o.c. screws 6" o.c. - loints finished ........ .......................................... �:_�"''-'"<:_��: . ::•�-' ::�-:=>.: �-,-.:-<:._< : - • optional veneer plaster 37 USG-860807 Based on 24" stud spacing ........ .......................................... 46 BBN-700725 Basetl on 24" stud spacing and 3" mineral wool batt 4Vt. 7 • 5/8" SHEETROCK BfBfICJ FIRECODE C COf@ 5� BBrI-7�({� ��.;;�:.��...,...w,�::�., Gypsum Panels ��� �}��y�7� - 2x4 wood stud 16" ar 24" o.c. 5'/, (riii�i��ilii Iitfiijltiiri -3"TH�ananFis�SAFB � t�� �� �� ��'� �.�: - RC-1 channel or equivalent one side - joints finished Fire Pertormance Reference �• 1 hour UL Des U305, SA920 A-25 U314 1 hour � UL Des U327 � � A-26 wt.12 • 5/8" Srie�Rock Brand Rr�cooe Core 52 USG-810218 2 hour UL Des U301 SA920 A-27 Gypsum Panels or SH�ocK Brand Based on same assembly (non-fire � �' �y� � � � `� � �� � � � � '' � � � � Water-Resistant Fa�coo� Core Gypsum rate� without mineral wool batt 6" Panels or F�aoac Brand Panels ........ ................................................... - 2x4 wood studs 16" o.c. 58 USG-810219 - joints finished • optional veneer plaster Chase Walls �' �' • 1/2" Sr{�rnocK Brand Fu�cooe C Core 57 RAL-TL-73-224 1 hour GA-WP-3810 A-28 Gypsum Panels, both outsitle both walls 3-1/2" glass fiber double layer and inside single layer • 5/8" Sr�moac Brand Fr�caoe Core 51 RAL-TL-69-214 , °• - �•• � � ��•- � Gypsum Panels, or Fie�RocK Brand Panels T� : :� :.:::.:::::..:.. .: . . .: _.. ................................................... - 2 rows 2x4 wood studs 16" o.c. on 56 US6-710120 separate plates 1" apart Based on 3-1/2" thick insulation 10Yz" -joints finished in one cavity ........ ........................................... 58 GA-NGC-3056 • 5/8" SHEETROCK Bf2fld FIRECODE C COfO 4T RAL-TL-69-211 _ Gypsum Panels or Fis�Rocic Brand Panels ........ ...................... - 2x4 wood studs 16" o.c. on 2x6 common 51 GA-NGC-2377 $„ plate � -jointsfinished �;:::.`.:::' `.:';::::;` ::::`::;::::`.:;;:;::;:':',":':';;:`.::;;`.;;:�: 20 USG Acoustica9 Assemblies 2 hour I GA-WP-3820 I I A-Z9 2 hour I GA-WP-3910 I I A-30 . ................................................ Sh���:t:1�'all Systerr.�s � Non-toadbearing Fire Performance � Reference wt. 9 • 1/2" Sr+e�rao�c Brand RRecooe C Core 38 USG-040917 G sum Panels, face la er oints finished T::::-�.::;.:::::::;:::::::.::::. _:::�:: :::.::.::..::: va v i ........................................................... 3%z" • 2-1/2" USG C-H Studs 25 gauge 24" o.c. 43 USG-040912 �;�-'%.T:::::'':%�::::�.�� :�� -.:::�:'� �>' • 1" SHe�rRocK Brand Gypsum Liner Panels Based on 4" C-H studs 25 gauge ........ ................................................... 48 RAL-OT-04-022 Based on 1" sountl batts in cavity ........ ................................................... 50 RAL-OT-04-019 Based on 4" GH studs 25 gauge with 3" mineral fiber insulation wt. 9 • 1/2" Sr{E�rRocK Brand RRecooe C Core 44 USG-040911 - � -• •- �-� Gypsum Panels Based on 4" C-H stutls 25 gauge --�—,� .:.. ...:......:.. : .. 3%i' ... ..:..:.. :. -..; . • 2-1/2" USG C-H Studs 25 gauge 24" o.c. .;.......:.. ;:... �`.;".`.`.`.":'`..::'.'.�:;:"'.`.: '.:;'�:`..'-'��,��:��'.�;"-- ;� • 1" SHe�reocK Brantl Gypsum Liner Panels — joints finished both sides 2 hour , UL Des U415, System B or U438 2 hour UL Des U415, System E or U467 SA926 IA-33 SA926 I A-34 wt.10 • 1/2" SHE�rRocK Brand Fa�cooe C Core 53 USG-040909 2 hour UL Des U415, SA926 A-35 � � �� Gypsum Panels applied vertically, Based on 4" C-H stutls 25 gauge System F q `�'`� face layerjoints finished with 3" mineral fiber insulation � •�� ��• — RC-1 resilient channel or equivalent ; , �: , . .. ........ ................................................... 24" o.c. 58 USG-040910 • 2-1/2" USG C-H Stutls 25 gauge 24" o.c. Based on 4" C-H studs 25 gauge • 1" Sri�rAocK Brand Gypsum Liner Panels with additional layer on liner panel side and 3" mineral fiber insulation 23 USG Acousticai Assemkt€es e ��''o o Cl. I' �'a rrt e d. � Dimensional Lumber clg. wt. 3 • 5/8" SHEETROCK Bf3lICI FRECODE COfO Gypsum Panels, ceiling —1" nominal wood sub and finished floor — 2x10 wootl joist 16" o.c. — joints finished • optional LEvewocK Brand Floor Underlayment • optional SRM-25 or SRB sound mat • optional veneer plaster clg. wt. 3 + 1/2" or 5/8" SHe�rRoac Brantl RREcooe C Core Gypsum Paneis —1-1/4" nominal wood sub and finished floor — 44 oz carpet and 40 oz pad atop floor — 2x10 waod joist 16" o.c. — RC-1 channel or equivalent —joints finished Pire Performance I Reference 38 32 CK-6412-7 1 hour UL Des L501 SA305 B-5 Based on 1-1/4" nominal wood SA920 floor ....... ....... ........................................... 39 56 CK-6412-8 Based on 1-1/4" nominal wood floor, 44 oz carpet and 40 oz pad atop flooring 47 67 GK-6512-7 1 hour Based on 1/2" SHEETROCK Brand R�cooe C Core Gypsum Panels ....... ................................................... 48 66 CK-6412-9 Based on 5/8" SHEETROCK Brand Ra�cooe Core Gypsum Panels B-6 cig. wt. 3 • 5/8" SHe�rRocK Brand Rr�cooe C Core 59 USG 740704 1 hour UL Des L516 SA920 B-7 . . . Gypsum Panels Based 3" mineral wool batt, —1-5/8" perlite-sand concrete 3/4" gypsum concrete and 1/2" 125�8, — plywaod subfloor SHEETfiOCK Bf8f1fl FIRECODE C — 2x10 wootl joists 16" o.c. Core Gypsum Panels — RC-1 channel or equivalent ........ ................................................... - •-::»�:.,,-:<:;. —joints finished 47 USG 740703 ..:.::.:::.::::::. �.:�_..::.-:... • optional veneer plaster Based on 3" mineral wool clg. wt. 3 bat, vinyl tile atop flooring ........ ................................................... 65 USG 740705 Basetl on 3" mineral wool batt, 44 oz. carpet and 40 oz. pad atop flooring • 5/8" SHe�ocK Brand Fr�cooe C Core 59 54 RAL-IN04-0�lfL04-033 1 hour Gypsum Panels Cushion vinyl Sloor — 2x10" wood joist 16" o.C. ........ ....... ........................................... — RC-1 channel or equivalent 16" o.c. 58 55 RAL-IN04-007/'f1.04-034 — Insulation held up untler subfloor by Engineeretl wood-laminate floor lightning clips ........ ................................................... — 19/32"T&G wood subfloor 59 77 RAL-IN04-005/TL04-032 • 3/4" L��ocK Brand Floor Underlayment Carpet with SRM-25 ........ ....... ........................................... 59 52 RAL-IN04-009/TL04-067 Ceramic tile with crack-isolation membrane ........ ................................................... 58 50 RAL-IN04-013/TL04-100 Cushion vinyl floar ........ ........................:.......................... 58 51 RAL-IN04-012/TL04-099 Engineered wood-laminate floor ........ ....... ........................................... 58 73 RAL-IN04-010/TL04-097 Carpet with SRB 25 USG AcoustiCal Assemblies SA305 I B-8 � n � Flo or/C eilings ........................................... �!v�od I i•amed � Dimensional Lumber • 2 layers 5/8" Sr+e�reocK Brand 52 RAL-IN-89-5 T``.. _:"._ - -�^— FiRecooe C Core Gypsum Panels ........ ....... ........................................... `� ` �— 8" x 8" ceramic tile 58 RAL-TL-89-145 • 1/2" DuRoac Brand Exterior Cement Board Basetl on vinyl tile over oriented ,�?�� ��n� • 1"Sr{�raocK Brand Gypsum Liner Panels strantl board in place of ceramic 7si;� j�j�k�riiiir(i�� iriii�tniii= i�i ,i �i �i � u�� —1/2" plywood tile and cement board — 2x10 wood joist 16" o.c. ........ ....... ........................................... ...... ....... . .... _.._. ...._. ........ — 3" mineral wool batt 51 RAL-IN-89-7 . .:..::: :...:..::: :.,:..::,:..::..,:.:. ,:..::.::.:. •: — — RC-1 channel or equivalent ........ ....... ........................................... 59 RAL-TL-89-746 Based on carpeVpad over orieMed strand board in place of ceramic tile and cement board ........ ................................................... 60 RAL-TL-89-141 ........ ....... ........................................... 62 RAL-IN-89-8 • 2 layers 5/8" Sf+e�rRocK Brand 59 RAL-TL-90-40 w.i:r. i � i i,ry!:!!n i � i..�!!rm!r i r�v�..!,,,� FiRecooe C Core Gypsum Panels - - - - - — 2x10 wood joists 16" o.c. .. . .69 .. RAL-IN-90-5 ....... . .. . .. . ... . . . - . ..,,:.:::.,,:.::... .. — 3" mineral wool batt ........ ....... ........................................... 13 ��� ��n� — RC-1 channel or equivalent 59 RAL-TL-90-40 t17'ltItllUld itti�l�l1t4i1 Basedonvinyltilein ���� ���� place of carpeUpad ���: �:�:.�:.:�::,.::;. �..:<:::��: �:.:,.;�;..; ........ ....... . ......................................... 37 RAL-IN-90-6 Engineered Joist clg. wt. 3 • 1/2" or 5/8" SHEETROCK Bf811d FIRECADE C 47 40 RAL-TL-81-87 Core Gypsum Panels, ceiling RAL-IN-81-16 — 3/4" T&G plywootl ........ ................................................. � — I-shaped wood joist 24" o.c. 54 RAL-IN-81-17 — metal furring channei 24" o.c. Based on carpet and patl 125je � —1-1/4" 8 pcf THeR�ie�a insulation atop flooring (UL Des 531) ........ ....... ......................................... —jointsfinished 43 RAL-IN-Si-79 �• optional 3/4" Levelrock Brand Floor Based on cushionetl vinyl atop ._ ..:..:: .: ..: ...: : .:.. ...: :.: . ....:: .: ..: ...:: .: .... :: Underlayment flooring • optional SRM-25 or SRB sound mat � 2 layers 1/2" Sr{�moc� Brand Ra�cooe C Core Uypsum Panels • optional SRM-25 or SRB sound mat i1lU1111))��_ �tlll'Iili�� —19/32°woodsubfloor 123�8� i.Ll1lJSJ�2l.! ��.iSLUSJtJ.� — 9-1/2"deep "I" shaped wood joist 24" o.c � ps�fi � ������� —14" parallel chortl wood truss 32" o.c. — RC-1 or equivalent • 3/4" LEve�aock Brantl floor Underlayment 64 58 RAl-OT03-05/06 1" LevEu�oc�, vinyl, SRM-25, .-.--•.- ----... .3 .1/2" insulation ............... 64 62 RAL-OT03-07/08 1" LEve�ocic, engineered wootl-laminate floor, SRM-25, 3-1/2" insulation ........ ................................................. 66 54 RAL-OT03-09/10 1" L�v��aocK, r,eramic tile, SRM-25, 3-1/2" insulation ........ ................................................. 65 54 RAL-OT03-01/02 3/4" LEvewocic, vinyl, SRB, 3-1/2" insulation ........ ....... ......................................... 66 51 RAL-OT03-03/04 3/4" LEVELROCK, ceramic tile, SRB, 3-1/2" insulation Fire Pertormance I Reference 2 hour I UL Des L541 I SA934 I B-9 2 hour I UL Des L541 I I B-10 1 hour UL Des L530 SA305 B-11 basetl on 9-1/2" deep TJI� joists UL Des L531 9" deep WSI� joist 1 hour I UL Des L570 I SA305 I 8-12 26 U&G Acoustical Assemb0ies Design Details ...................:.................. ..................... l�%oc�d. I�ram.ed. Sound :� �. � � �� �. :�:I: � :I:��:I: Va" SHEETROCK �`� � Brand gypsum �� .' panel :� .' �:� Vz" SHE�ocK Brand • i� •� �. � i FlRecooe core � � • gypsum panels ;1'. . ' •1'. SHe�rRocK Brand acoustical sealar Ceiling/floor attachment — SxeernocK Brand gypsum panel � �. f�: SHEErnopc Brand jointtape -- �� - sound insulation , - ----- _ - ' . J. _ _.-- - Floor attachment : .I' - — - .}�� —_= SHe�rRoctc Brand �• J - --- " gypsumpanel ---- :':) _�_ �� _-- - - ' �--�_ SHeeraocK Brand acoustical sealant Sound isolating partition — chase wall __ _ _ _ .� 5/a" SHe�rRocK Brantl FiAECooE core gypsum panels � � ____- �1 .l �___ :i t� �__= �:, sound insu!ation � •'•: -_._-- :'.i ��� �_-_ �� �� �-_- �: �,•� t2 x 4 wood studs1 � _ � _ �. � Brantl acoustical sealant Ceiling/floor attachmenVSxeerxocK Brand ;'. - • �'�'. � '—� ' /.':"�' : 't� �SHEETROCK Bf211d SHEEfAOCK Bfefld acoustical sealant joint tape —� � • .• .� , Finecone C Core panel •.1�: �� •,: �� SHEETROCK Bf3fld' ./�I� acoustical sealant :I�::I::� '--- :�:I:�:I: — RC-1 resilient soundinsulation f �•�• RC-1 resilient channel or ' —' - t• E channel or equivalent --- •\• \ equivalent :�� ���. ___ - - �.:1��.:� Floor attachment ' � • � � - -- - � —2x4 Wood StUd 1" ��:' --- �l� : l` 5/e' SHEETROCK �" - r �/2 � ��2� �. �• --'�" �6' �.'. Brand gypsum • • � • panels � -� �• - -- - ___ �� ��: — RC-1 resilient � _ _ - • • ; RC-1 resilient channelor •;�•; :j•; --_ ;I; .';: channelor equivalent (may ' _ � - - equivalent (may be inverted to � � -� �('�� be inverted to ease attachment �. \. ease attachment ofbase) �.1.; �.y j.l �.�. ofbase) SHE�rRocK Brand acoustical sealant 27 USG Acoustical AssemBlies Design Details .....:............................................................................. Z�'oo��. I+i�ariied. Single-layer panels with RC-1 Channel � �' '.�• .',--,%: ,! 2x4 wootl stud SriE�raocK Brand gypsum panel RC-1 resilient channel or equivalent — RC-1 resilient channel or ea� r � r •.'-�%: ✓ _ ��;�,, .��, .�, , �, ' '� ..•�=� SHEETROCK ' • "-� � ��T'� • �" 1•„• Brand � • � acoustical 2x4 wood stud — h. � _ sealant - �C; RC-1 resilient � - sound channel or equivalent - __.__ _ insulation SHeEraocK Brand .� _ =- .';: gypsum panels � � - , Ceiling and floor assemblies '/x" plywood subfloor 25/sz" oak finish floor 2 x 10 joist rosin paper � 6" o.c. RC-1 resilient channel or } equivalent-screw applied L'/z" SriEETRocK Brantl with RC-1 Channel :� RC-1 resilient channel or eqi ;• �'^ I Brand _ � - r \ acoustical --_ _ ��•� • (.' sealant i ---- :�' i.•� _ � - sountl ----_ �:':;: insulation ' -- ,�,. �.:� FiREcooe C core gypsum panels FIREcooE C core gypsum panels Ceramic tile Ynyl tile or carpeUpad UL Design L541 8" x 8" ceramic tile '/z" DURocK Brand DuRocK Brand vinyl tile or 1 Vz" pumped, self-leveling gypsum exterior cement board ceramic tile adhesive carpet with pad cement flbor underlayment (type F� _ . _ ,. �, ; � ,� , � �•� :,. � � ,� � ,� ��� , �, � � �� � � � ,�...: ,.•....., .,.� .....: .. ...... ,. �. •�. :� '� R-SHEEfflOCK BfBfld 1�� SHEEfROCK Bfdfld �SHEETROCK Bf211d acoustical sealant gypsum liner panel '�2" Plywootl acoustical sealant 'h" Plywood insulation pinned 2x10 wood 2x10 wood between jaists joists 16" o.c. jaists 16" o.c. ���r� „ .n�nn�n�rsn n�rsr �n�r� r�n�r�rsn�n�rsn n�r�r i�tiiiiii iiiiiiiiiiiiiiiiiiiiiiiiiii iiiiiiiii iiiiiiiii iiiiiiiiiiiiiiiiiiiiiiiiiiii iiiiiiiii „„, ., l ll )�.Zu t lt ), ,,���� u s.�..�u� .�iui� '�uu'�+'iu'u�i.�uuu.�' 's�iv� � �� 1 �� - - - - - - - - - - - -- • ,-,. . - -- _ _ .i _ � 2 layers of 5/a" SHEEraoCK RC-1 resilient channel 3" soundattenuation 2 layers of 5/e" SHeeraoCK RC-1 resilient channel 3" sound attenuation Brand FiAEcooe C core or equivalent 16" o.c. blankets 1" above Brand FiaEcooe C core or equivalent 16" o.c. blankets 1" above gypsum panels bottom of joists gypsum panels bottom of joists 28 USG Acoustica! Assemblies Flanl�.ing Path Details ............................................................................................................................................................................................. T;���ica! l.alar.il.rir�g l'at�rs Doorway Placement — Avoid ��� ,:,�, �� �. F��� HVAC Design — Avoid � .,��,� � '�� �� �f�,,... ���� ��� � �._.,�..,� �,...�;.,�,,� �..��,� 3;� ,,a, :�.q �: � I I I HVAC Design — Avoid HVAC Design — Better 32 USG Rcoqstica! Assemblies Uoorway Placement — Better HYAC Design — Recommended I:�lter:�•�rptirig I'lat�.ii:ir.i� Pat��s Resilient Channel Wall Framing — Avoid :� l� stud J ;�, � short circuit �` �� � �� Electrical Boxes — Avoid Resilient Channet Wall Framina — Recommended / ).r stud ((,J �`• correct \` �.l � �; Electrical Boxes — Better Electrical Boxes - Recommended minimum separation Cabinet Cutout 33 USG Acoustical Assembiies , Flanking Path Details ....................................... ................................ ....................................................... ........................ ...................................... f.�ltez�•��ptin� I�:Ianl.:an�, I'at}ls—l��Iultif:a�zailsr Gor�st:r�.�ci�ior.i Joists SHEernocK Brantl acoustical sealant .-i� — SHEETROCK Brand acoustical sealant SHEETROCK BfBfld acousGcal sealant Adjacent Bathrooms - - caulking _ = tub _ = extend water = = resistant substrate _ — behind tub Attic Adjacent Kitchens Note See pg. 29 for high-performance partition. 34 USG Acoustieaf Assemblies � 0 � - � � .............................�-----........................ I.z�te7rtxF�t:in.� I� larticir:�� I'at}as—.�1.co��stical Ce:rl.i:ri�,s Acoustical Panel — Exposed Grid hanger wire — exposed spline compressible Acoustical Tile — Adhesive Attachment Acoustical Panel — Concealed Grid spline �metal spline compressible sheet metal ; 1 Vz col d rolled channel channel FI" anchor gypsum pane compressible 35 USG Acousticei Assembiies Good Design Practices In most building design, the No. 1 acoustical goal is to specify wall partitions, ceiling systems and floor/ceiling assemblies that will minimize transmission of airborne and impact sound beyond their areas of origin. This performance can be achieved with a combination of materials, assembly designs and construction methods tested for acoustical performance on a variety of parameters. Here is an overview of design strategies for key components that can malce spaces more pleasant, comfortable and productive. Ceilings Absorb Sound in Open Spaces Select high-NRC ceiling panels for open areas to absorb a significant amount of the sountl generatetl within these spaces. Acoustics are further improved with partitions having high STC values to help block sound and prevent transmission across large spaces. Block Sound in Enclosed Spaces Choose high-CAC ceiling panels for private offices, meeting rooms and other enclosed areas to block sountl from traveling up into the plenum and out to atljacent spaces. This approach wiil reduce distractions for those outside and improve speech privacy for those within. Cover Sound in Ali Areas Sound masking covers noise that is not absorbed or blocketl by introducing uniform, ambient, background sountl into the space. Sound masking produces an electronic sountl spectrum similar to that of softly blowing air; it is amplified through speakers above the suspendetl ceiling to unobtrusively raise the backgrountl sountl level. Sound masking makes noise in open spaces less distracting, increases speech privacy in enclosed spaces and provitles greater acoustical balance throughout. Wafls Increase mass As partition mass increases, sountl waves lose more energy passing through the medium, reducing their ability to vibrate air on the other sitle. Relying on mass alone, however, poses limitations. Doubling the mass of a partition can reduce sound transmission by up to 5 tlB. Thus, achieving a 60 dB reduction would require total mass of 320 pountls per square foot, the equivalent of approximately 3' of solitl concrete, not a feasible solution for most builtling tlesigns. Enlarge air spaces Isolating air space within a partition can increase STC performance. But like increasing mass, pertormance increases are limited. Doubling partition air space can retluce sountl transmission by up to 5 d6, so achieving a 60 d6 reduction would require an isolated air space 4' wide, hartlly practical for most applications. 36 USG Acoustical Assembiies Add sound insulation Atlding a layer of fibrous sountl-absorbing insulation material such as mineral wool into the partition cavity will tlissipate sountl by creating friction, which transforms a portion of sountl wave energy into heat. However, sound attenuation blankets cannot completely counter the conductivity of the wood or steel studs in the framing assembiy, v�hich provitle a path of least resistance for sountl energy. Decouple wali paneis Attaching the wall surface tliaphragm (e.g. drywall panels) tlirectly to framing members provitles an uninterrupted path for sound travel. This route.can be interrupted by mounting the surface diaphragm to resilient channels attachetl to the wall studs and placing sound insulation inside the partition cavity. Seal flanking paths Closing off gaps or penetrations in the wall assembly is critical to controlling noise. One of the most effective methotls is to apply acoustical sealant at the intersection of the gypsum panel, floor system (wood or concrete), and the leg of the steel runner or wootl sole plate; sealant shoultl be applied at this location on both sitles of the partition. A properly sealed wall assembly with one 5/8" gypsum panel on each sitle and a 1-1/2" thick sound attenuation blanket instalied in the air cavity achieves an STC of 53. Without acoustical sealant, this assembly woultl produce an STC of only 29—a dramatic 45 percent retluction. Increase isolatian with steel studs A single-layer partition with 5/8" gypsum panels antl 3-5/8" stutl achieves 40 STC with 25-ga. steel antl 38 STC with 20-ga. steel. STC falis to 35 with a tratlitional 2' x 4' stud due to the greater stiffness of wootl. Fioor/Geiling Assemhlies Isolate sound Whether constructed with joists, trusses or concrete slabs, floor systems can develop gaps or cracks, providing a flanking path for sound to travel between levels of a building, Even properly sealed assemblies can transmit noise from footsteps, faliing objects, closing doors antl other impacts. These acoustical problems can be significantly reduced with a fiooring system that inclutles a layer of sound absorbing material toppetl with a pouretl cementitious underlayment. The poured underlayment finds antl seals cracks antl other sountl channels, then hardens to form a solitl barrier isolated from the structure below by the sountl mat or boartl. This system can provide STC ratings as high as 66 and increase IIC by as much as 13 points, a significant improvement. 37 USG Acousticai Assemblies Q <' Bui3ding Type STC Guidelines Room Residen#ial, Bedroom it�cluding moYels, hospitals, and dormitories Living Room Kitchen or Bathroom Business Office Conference Room General Area Schoot Classroom Music Room ST� Adjacent Room Minimum° Medium High Room Bedroom 45 50 55 . ................................ .................................. ..... .............................. Living roam 50 55 60 .................................. .................................. ................................... .................................. Kitchen 50 55 60 .................................. .................................. ................................... ................................... Bathroom 50 55 60 .................................. .................................. ................................... ................................... Corritlor 45 50 55 .................................. .................................. ................................... ................................... Lobby 50 55 60 .................................. .................................. ................................... .................................. Mech. room 55 60 60+ Living room 40 45 55 .................................. .................................. ................................... ................................... Kitchen 45 50 60 .................................. .................................. ................................... .................................. Bathroom 45 50 60 . ................................ .................................. ..... ............................... Corridor ' 45 45 55 .................................. .................................. ................................... ................................... Lobby 50 55 60 .................................. .................................. ................................... ................................... Mech. room 50 60 60+ Kitchen 40 45 50 .................................. .................................. ................................... ................................... Bathroom 40 45 50 .................................. .................................. ................................... ................................... Carridor 40 40 50 .................................. .................................. ................................... ................................... Lobby 45 50 60 .................................. .................................. ................................... ................................... Mech. room 45 55 60+ Office 45 50 55 .................................. .................................. ................................... ................................... General area 40 45 50 .................................. .................................. ......................:............ ................................... Corridor 40 45 50 .................................. .................................. ................................... ................................... Washroom 45 50 55 .................................. .................................. ................................... ................................... Kitchen 45 50 55 .................................. .................................. ................................... ................................... Conference room 45 50 55 General area 40 45 50 .................................. .................................. ................................... ................................... Corridor 40 40 45 .................................. .................................. ................................... ................................... Washroom 40 45 50 .................................. .................................. ................................... ................................... Kitchen 45 50 55 .................................. .................................. ................................... ................................... Conference room 40 45 50 Corridor 40 40 45 .................................. .................................. ................................... ................................... Washroom 40 45 50 .................................. .................................. ................................... ................................... Kitchen 45 50 55 Classroom 45 50 55 .................................. .................................. ................................... ................................... Laboratory 45 50 55 .................................. .................................. ................................... ................................... Carridor 40 40 45 .................................. .................................. ................................... ................................... Kitchen 50 55 55 .................................. .................................. ................................... ................................... Shop 55 60 60 .................................. .................................. ................................... ................................... Recreation area 45 50 55 .................................. .................................. ................................... ................................... Music room 60 60 60 .................................. .................................. ................................... ................................... Mech. room 50 55 60 .................................. .................................. ................................... ................................... Washroom 45 50 55 Laboratory 45 50 55 .................................. .................................. ................................... ................................... Corridor 45 50 55 .................................. .................................. ................................... ................................... Shop 50 55 60 .................................. .................................. ................................... ................................... Recreation area 50 55 60 .................................. .................................. ................................... ................................... Music room 55 60 60 .................................. .................................. ................................... ................................... Mech. room 50 55 60 Note (� Current model building codes require a minimum STC (antl IIC) separation of dwelling units. The 2003 International Building Code requires a minimum separation of 50 STC antl 50 IIC for apartments, condominiums antl townhouses. Local Jurisdictions using the 2003 International Residential Code may require a minimum separation of 45 STC for townhouses. 38 U&G Acoustical Assemblies RESOLUTION APPROVING MITIGATED NEGATIVE DECLARATION ND 536-P, CONDOMINIUM CONVERSION PERMIT AND CONDITIONAL USE PERMIT RESOLVED, by the Planning Commission of the City of Burlingame that: WHEREAS, an application has been made for mitigated ne�ative declaration ND 536-P, condominium conversion permit and conditional use permit for floor area to convert a five-unit office/warehouse building to five office/warehouse condominium units at 821 Cowan Road, zoned_IB Konstantinos Dokos, property owner, P.O. Box 953, Millbrae, CA, 94030, APN: 024-401-560; WHEREAS, said matters were heard by the Planning Commission of the City of Burlingame on April 24, 2006, at which time it reviewed and considered the staff report and all other written materials and testimony presented at said hearing; NOW, THEREFORE, it is RESOLVED and DETERMINED by this Planning Commission that: 1. On the basis of the Initial Study and the documents submitted and reviewed, and comments received and addressed by this commission, it is hereby found that there is no substantial evidence that the project set forth above will have a significant effect on the environment, and a mitigated negative declaration, per Mitigated Negative Declaration ND-536-P, is hereby approved. 2. Said condominium conversion permit and conditional use permit are approved, subject to the conditions set forth in Exhibit "A" attached hereto. Findings for the condominium conversion permit and conditional use permit are as set forth in the minutes and recording of said meeting. 3. It is further directed that a certified copy of this resolution be recorded in the official records of the County of San Mateo. Chairman I, , Secretary of the Planning Commission of the City of Burlingame, do hereby certify that the foregoing resolution was introduced and adopted at a regular meeting of the Planning Commission held on the 24th day of A��ril by the following vote: Secretary EXHIBIT "A" Conditions of approval for mitigated negative declaration ND 536-P, condominium conversion permit and conditional use permit. 821 Cowan Road Effective May 4, 2006 1. that the project shall be built as shown on the plans submitted to the Plaruiing Department date stamped March 6, 2006, sheets L.2, A.3, A.3A, A.4 through A.7, D.1, E.1, E.2, C.l, AS.1 through AS.3, C-1 through G-S, Lighting Details (81/Z" x 11" sheet) and date stamped April 13, 2006, sheets T.1 and L.1, Vesting Tentative Tract Map, and the Physical Elements Report, Physical Standards Report and Acoustical Assemblies Report date stamped December 27, 2005; 2. that the reports required by this code, in a form approved by the city, shall be provided to each person executing any purchase, rental or other agreement to purchase or occupy a unit in the project. Copies of the full reports shall be made available at all times at the sales office and shall be posted at various locations, as may be required by the city, at the proj ect site; 3. that a new 7'-0" wide sidewalk shall be installed along the front of this property as shown on the plans date stamped April 13, 2006, sheets T.1 and L.1; the new 7'-0" wide sidewalk, curb and gutter and driveway apron shall comply with the Public Works' construction standards and shall be installed prior to the final inspection; the applicant shall obtain the necessary special encroachment permit to install the curb, gutter and sidewalk and driveway apron; 4. that the applicant shall plant two 24-inch box Sycamore trees at the front of the property for replacement of the existing Sycamore tree to removed; 5. that the conditions of the City Attorney's February 3, 2006 memo, the City Engineer's January 30, 2006 memo, the Fire Marshal's January 4, 2006 memo, the Chief Building Official's January 3, 2006 memo, the Recycling Specialist's January 4, 2006, memo, and the NPDES Coordinator's January 6, 2006 memo shall be met; 6. that the final inspection shall be completed and a certificate of occupancy issued before the close of escrow on the sale of each unit; 7. that the developer shall provide to the initial purchaser of each unit and to the board of directors of the condominium association, an owner purchaser manual which shall contain the name and address of all contractors who performed work on the project, copies of all warranties or guarantees of appliances and fixtures and the estimated life expectancy of all depreciable component parts of the property, including but not limited to the roof, painting, common area carpets, drapes and furniture; 8. that if a security gate system across the driveway is installed in the future, the gate shall be installed a minimum 20'-0' back from the front property line; the security gate system shall include an intercom system connected to each unit which allows occupants to communicate with guests and to provide guest access to the parking area by pushing a button inside their units; -2- EXHIBIT "A" Conditions of approval for mitigated negative declaration ND 536-P, condominium conversion permit and conditional use permit. 821 Cowan Road Effective May 4, 2006 9. that demolition for removal of the existing structures or walls within the condominium units and any grading or earth moving on the site shall not occur until a building permit has been issued and such site work shall be required to comply with all the regulations of the Bay Area Air Quality Management District; 10. that the project shall comply with the Construction and Demolition Debris Recycling Ordinance which requires affected demolition, new construction and alteration projects to submit a Waste Reduction plan and meet recycling requirements; any partial or full demolition of a structure, interior or exterior, shall require a demolition permit; 11. that the project shall be built as shown on the plans submitted to the Planning Department date stamped February 4, 2005, sheets T.l, L.1, T.2, A.1 through A.7 and Plat of Survey; 12. that a seating area, to be architectural compatible with the building, shall be designed at the front entrance to the building; 13. that vines, to grow along the front wall of the building, shall be planted and maintained by the property owner; 14. that the windows and window trim shall be installed as shown on the detail, date stamped February 4, 2005; 15. that the parking variance shall only apply to this building and shall become void if the building is ever expanded, demolished or destroyed by catastrophe or natural disaster or for intentional replacement; 16. that the conditions of the City Engineer's and Fire Marshal's June 1, 2004, memos, the Chief Building Official's February 9, 2005, and June 4, 2004, memos, the Recycling Specialist's June 2, 2004, memo and the NPDES Coordinator's January 31, 2005, memo shall be met; 17. that payment of a Bayfront Development fee to the City of Burlingame for traffic impacts in the Inner Bayshore and Shoreline areas shall be required to mitigate cumulative impacts of this and other projects on area circulation, one-half of the fee is due at the time of planning application and one-half due before the final framing inspection; 18. that one-way directional signage shall be installed and painted throughout the parking area to clearly define the vehicular direction for employees and visitors to the site; prior to issuance of a building permit, the applicant/property owner shall work with the City's traffic engineer to determine the required signage and markings on the pavement to clearly identify the on-site vehicular direction; -3- EXHIBIT "A" Conditions of approval for mitigated negative declaration ND 536-P, condominium conversion permit and conditional use permit. 821 Cowan Road Effective May 4, 2006 19. that the driveway aisles in front of the roll-up doors at the rear of the building and in the parking area shall be maintained clear and trucks shall not be stored or parked in the driveway aisles; 20. that the paved area adjacent to parking space #15 shall be painted "No Parking" to provide a clear, unobstructed back-up area for the disabled-accessible parking spaces; 21. that the 53 on-site parking spaces shall be used only for the customers and employees of the businesses at this site and shall not be leased or rented for storage of automobiles either by businesses on this site or by other businesses for off-site parking; 22. that the landscaping noted on sheet L.1 shall be installed according to plan and shall be irrigated with an automatic irrigation system; landscaping that does not survive on the site shall be immediately replaced with an equivalent species; 23. that the property owner shall provide a complete Irrigation Water Management Conservation Plan together with landscape and irrigation plans at time of permit application; 24. that the office/warehouse building shall be built so that the interior noise level in all areas used as office does not exceed 45 dBa; 25. that all construction shall abide by the construction hours established in the City of Burlingame Municipal Code, and shall occur only between the hours of 7:00 a.m. and 7:00 p.m. on weekdays, 9:00 a.m. and 6:00 p.m. on Saturdays, and 10:00 a.m. and 6:00 p.m. on Sundays and holidays; 26. that on-site illumination shall be shielded and directed only on to the site in compliance with the City's exterior illumination ordinance; 27. that all parking areas should be lit for safety at night, such lighting should comply with the requirements of the City's exterior illumination ordinance; 28. that the remodel/addition shall not be built with a reflective exterior finish; 29. that the project shall obtain necessary permits to meet the standards of the required permitting agencies including: Bay Area Air Quality Management District; 30. that the project design shall conform to all seismic related requirements of the latest edition of the California Building Code as amended by the City of Burlingame in effect at the time a building permit is issued and any additional seismic requirements established by the State Architect's office; � EXHIBIT "A" Conditions of approval for mitigated negative declaration ND 536-P, condominium conversion permit and conditional use permit. 821 Cowan Road Effective May 4, 2006 31. that all construction shall be required to be done in accordance with the California Building Code requirements, 2001 edition, as amended by the City of Burlingame, and in addition to the limitations of hours of construction imposed by the City of Burlingame Municipal Code (CS 18.08.035); 32. that all new utility connections to serve the site and which are affected by the development shall be installed to meet current code standards and diameter; existing sewer laterals shall be checked and replaced if necessary; 33. that water and sewer lines shall be constructed from flexible material with flexible connections with the degree of flexibility established by the City Engineer and with his approval and inspection; 34. that in the event that there is subsidence as the result of an earthquake, the site shall be repaired as approved by the City Engineer; 35. that all site and roof drainage shall be directed to the street frontage; 36. that low flow plumbing fixtures shall be installed and City water conservation requirements shall be met at all times, including special additional emergency requirements; 37. that the grading plan shall be prepared by a licensed Civil Engineer and approved by the City Engineer. All applicable requirements of the NPDES permit for the site shall be adhered to in the design and during construction; 38. that if construction is done during the wet season (October 15 through April 15), that prior to October 15 the developer shall implement a winterization program to minimize the potential for erosion and polluted runoff by inspecting, maintaining and cleaning all soil erosion and sediment control prior to, during, and immediately after each storm even; stabilizing disturbed soils throughout temporary or permanent seeding, mulching matting, or tarping; rocking unpaved vehicle access to limit dispersion of mud onto public right-of-way; covering/tarping stored construction materials, fuels and other chemicals; 39. that all applicable San Mateo County Stormwater Pollution Prevention Program Best Management Practices shall be adhered to in the design and during construction, including stabilizing areas denuded due to construction prior to the wet season; erosion shall be controlled during and after construction to protect San Francisco Bay waters; -5- EXHIBIT ��A" Conditions of approval for mitigated negative declaration ND 536-P, condominium conversion permit and conditional use permit. 821 Cowan Road Effective May 4, 2006 40. that the applicant shall submit an erosion and sedimentation control plan describing BMPs (Best Management Practices) to be used to prevent soil, dirt and debris from entering the storm drain system; the plan shall include a site plan showing the property lines, existing and proposed topography and slope; areas to be disturbed, locations of cut/fill and soil storage/disposal areas; areas with existing vegetation to be protected; existing and proposed drainage patterns and structures; watercourse or sensitive areas on- site or immediately downstream of a project; and designated construction access routes, staging areas and washout areas; 41. that the erosion and sedimentation control plans should include notes, specifications, andlor attachments describing the construction operation and maintenance of erosion and sediment control measures, including inspection frequency; methods and schedule for grading, excavation, filling clearing of vegetative cover and mulch, including methods and schedules for planting and fertilization; and provisions for temporary and permanent irrigation; 42. that all runoff created during construction and future discharge from the site shall be required to meet the applicable San Mateo County Stormwater Pollution Prevention Program Best Management Practices for surface water runoff and Storm Drain maintenance; 43. that all runoff in the parking lot, including runoff from the landscaped areas, shall be filtered to remove oil and grease prior to discharge by a method approved by the City Engineer and such facilities shall be installed and maintained by the property owner, failure to maintain such filters and facilities in working conditions shall cause this conditional use permit to be called up for review, all costs for the annual or more frequent inspection and enforcement of this condition shall be paid for by this project's property owner; 44. that the phrase "No Dumping-Drains To Bay" shall be labeled on new storm drain inlets by stenciling, branding, plaguing or casting; 45. that grading shall be done so that impacts from erosion and runoff into the storm drain will be minimal; 46. that each storm water inlet on the site shall be equipped with a sand/oil separator; all sand/oil separators shall be inspected and serviced on a regular basis, and immediately following periods of heavy rainfall, to ascertain the conditions of the chambers; maintenance records shall be kept on-site and maintenance shall be as directed by the City; � EXHIBIT "A" Conditions of approval for mitigated negative declaration ND 536-P, condominium conversion permit and conditional use permit. 821 Cowan Road Effective May 4, 2006 47. that drainage from paved surfaces, including parking lots, driveways and roofs shall be routed to storm water inlets equipped with sand/oil-separators andlor fossil filters, then the water shall be discharged into the storm drain system; the property owners shall be responsible for inspecting and cleaning (vacuuming out) sand/oil separators and changing fossil filters on a regular basis as well as immediately prior to, and once during, the rainy season (October 15 — April 1) and as directed by the City; 48. that off-site runoff shall be diverted around the construction site and all on-site runoff shall be diverted around exposed construction areas; 49. that trash enclosures and dumpster areas shall be covered and protected from roof and surface drainage and that if water cannot be diverted from these areas, a self-contained drainage system shall be provided that discharges to an interceptor; 50. that no vehicles or equipment shall be washed, cleaned, fueled or maintained on-site; 51. that methods and procedures such as sediment basins or traps, earthen dikes or berms, silt fences, straw bale dikes, check dams storm drain inlet protection soil blanket or mats, and covers for soil stock piles to stabilize denuded areas shall be installed during construction to maintain temporary erosion controls and sediment control continuously until permanent erosion controls have been established; 52. that the site shall be sprayed with water to control dust during grading and construction. Construction equipment emissions shall be in compliance with the standards of the Bay Area Air Quality Management District; 53. that a construction fence, including a impermeable fabric/material, shall be required around the site during construction to keep all construction debris on site; 54. that if any trenching is proposed on the site, the applicant shall contact the San Mateo County Health Department; if any contaminated soil is encountered, the applicant shall follow County protocol for its disposal; and 55. that if any prehistoric or historic archeological relics are discovered during grading and construction, all work shall be halted until the finding can be fully investigated and proper protection measttres, as determined by qualified experts, can be implemented. -7- . . . .. i _ .. ._ . , . . . + �� CITY o,� . CITY OF BURLINGAME • ' I '� - PLANNING DEPARTMENT -' -— i BURIJNOAME 501 PRIMROSE ROAD ' �_• � BURLINGAME,CA94010 '�,"''� 0151�1650432� ' ! ' ; ,m :TEL: (650)'558-7250 • FAX: (650) 696-379 a . .,.�.�6• www.burlingame.org � ������ . � Ao,� , � _ . i Site: 821 COWAN ROAD ��'' �`� . ' i � R9aeled From �4�'� . , �JS �QSTAGE Application for condominium conversion i permit for an existing office/warehouse PUBLIC- HEARING :;` I building at: 821 COWAN ROAD, zoned IB. NOTICE . � (APN: 024-401-560). , . . . � � . . �.� . � The City of Burlingame Planning Commission �ti � ��` � Y� ���`'�`� announces the following public hearing on r''� '� �'�'�� � �"� . .. . . . . . . ...� � .� � W � * � i Et �3.t i ra- .. , . Monday, April 24, 2006 at 7:00 P.M. in the City "' ���`� �� ��'� �� r 4� �� '„' , ,� : �. i u � c -aaw�-` ''L � � e'i -:< Sr � � � .,,, 3 . z � ;r�K'_ ``3�, �a -�£, .'°'p; a'�� '. . . Hall Council Chambers located at 501 Primrose z � � r �.� � -� � � �-� . . � F . : � z. * -� .���q„ u� -� , . Road, �urlingame, California. � r � �f � � r;.� � � �, ° { . - � �r �z,,E � , ' � . 5 :a3 f Y` � yr -.. ^k'��" i'.". a � � � s!3' �`" . . Mailed: April 14, 2006 � . �r° � �'�` � , � ; � � r� �� ���� ���x� � , . . • . . . . . . . -'.�—.-_.� a,+,r �S��j^`vzt r ���e. +'� •'r-�7:.:::�"_ � . � � � (Please refer to other side) :... . .. . � _.�� A copy of the a� to the meeting Burlingame, C�� If you challe "ri" e raising only t��� described in »h� at ar prior to thE .� Property ow ��r, their tenanfs�ab� (650) 558-7�-'0 CITY OF B URLINGAME �,�. ���,_��..���,�r.�:� � . ��� � � � � � �;,-�"� �� plica�,inn and�p�an� far this project�ay be reviewed prior ���� � Margaret Moru�c� �� City Planner � � PUB�LI� ` (Please refer to other side) t����t� �f�S41 Primrose Road, . � ,� �� "� �.,�.�"� . � � � , :�� . � ���aurt, ��u ma� � be limited to � � .Ar ��� �,�--�:���f�,�.t bl• h �" � � '���: 3E �. � ! �� ic earuig, ie�ed to the city � � :or informing i . i�, please call �� - ��.�� �� �� �� . O.TICE y : ,: : , A-i'-i�ac�w,�,,,-�- 821 Cowan Road Compliance with Bayfront Design Guidelines — Inner Bayshore Area (based on project approved by PC on February 28, 2005) Design Guidelines Compliance Floor Area Ratio: 0.9 FAR for Office office: complies (0.6 FAR for office) 0.5 FAR for Warehouse warelaouse: does not comply (0.6 FAR for warehoaise) Builcling/Street Relationships: Building entries should face the street, and should be complies easily identiiiable. Businesses at important intersections should locate their not applicable entrances at the building corner. Curb cuts should be limited to ease pedestrian/vehicular complies conflict. Businesses fronting on Bayshore Highway should have not applicable an attractive 15' landscaped front setback and a 8'-10' wide sidewalk. Businesses fronting on all other streets should have an landscaping: complies (15' landscaped front setback) attractive 10' landscaped front setback and at least a 6' sidewalk: does not comply, no chan�es proposed, sidewalk. existing sidewalk width on this block is 5�- o", Seating areas should be encouraged within the front does not comply, no seating area proposed setback. (cont'd) Com liance with Ba front Desi n Guidelines — Inner Ba shore Area Design Guidelines Compliance Parking: Parking is not allowed in front setback. complies Parking should be screened with landscaping and/or low partially complies screen walls. Truck loading areas should be located to the rear of complies buildings, and screened from view. Parking entry drives should be encouraged to be shared complies, share access easement existing with adjacent with adjacent businesses to minimize multiple curbcuts. property Parking areas should be broken up with landscape �ngers complies with no more than 6-7 spaces between the fingers. Encourage pervious surfaces in all site paving, information not provided particularly pedestrian traffic areas such as entry courtyards etc. Landscaping: Landscaping should protect and enhance view corridors. complies Landscaping can be used as a visual buffer to shield complies parking and loading areas. Landscape features should not just be visually appealing, does not comply but also should function as open space amenities to be used and enjoyed. Landscaping should enhance the site, but not obscure complies building signage and entrance areas. Building signage should be incorporated into the not applicable landscaping. 15% of the site area shall be landscaped, with 5% of the site area: complies, 15.9% of site parking area and 60% of the front setback devoted to parking area: complies, 11% of parking area landscaping (front setback landscaping may include front setback: complies, 90% of front setback hardscape features such as walkways and seating areas). Parking isn't allowed in front setbacks, only driveways complies and accent paving. (cont'd) Com liance with Ba front Desi n Guidelines — Inner Ba shore Area Design Guidelines Compliance View Corridors: Views may be framed by buildings. complies View corridors may terminate with a landmark building. not applicable Pedestrian plazas should be incorporated in the design of does not comply, site is adjacent to Cowan Road view view corridors. corridor Any new development should respect existing view complies corridors. View corridors at the ends of streets shall tie into visual complies openings to the bay across Bayshore Highway. Street Design: Streets should be designed for both the automobile and no changes to street the pedestrian / bicyclist. A variety of lighting features should be used to no changes to street lighting accommodate both the driver and pedestrian. Lighting should also help increase visibility of businesses, but not flood their facades. The design of the sidewalk and setback area should does not comply create an urban character and should feature amenities such as street trees with tree grates, planters, benches and removable cafe furniture. Bayshore Highway should receive priority in any not applicable streetscape program. The street should be designed as a "Grand Boulevard" with landscaping, lighting and sidewalk standards the same on both sides. (cont'd) Com liance with Ba front Desi n Guidelines — Inner Ba shore Area Design Guidelines Compliance Building Design: Buildings should have entries directly accessible and complies visible from the street. Entries should be marked by architectural features such complies as projecting overhangs, special lighting, awnings and signage that emphasize their importance. Building facades should be designed to have a rhythm complies and pattern and should be articulated as an expression of the building use. The use of reflective or dark-tinted glass should be complies discouraged, especially at ground level, because it creates an effect which lacks the visual interest of clear window openings. Building facades should be articulated with a building complies base, body and roof or parapet edge. All visible sides of buildings should be designed with the complies same level of detail. Exterior building materials and finishes should convey a complies sense of integrity, permanence and durability, rather than applique. Building should be no more than two stories, 35 feet in complies (32'-4") , height.