Loading...
HomeMy WebLinkAbout2930 Adeline Drive - Staff ReportItem #1 CITY OF B URLINGAME HILLSIDE AREA CONSTRUCTION PERMIT AND FRONT SETBACK VARIANCE Address: 2930 Adeline Drive Meeting Date: 3/9/98 Requests: Hillside area construction permit (CS 25.61.020) and front setback variance (CS 25.55.010 l,a) for a first and second floor addition qualifying as new construction at 2930 Adeline Drive, zoned R-1. Applicant: Joyce Ford, designer APN: 027-030-040 Property Owner: Kathy Hutchison & Luis Rosario Lot Area: 51,445 SF (1.18 AC) General Plan: Low Density Residential Zoning: R-1 Adjacent Development: Single Family Residential CEQA Status: Article 19. Categorically Exempt per Section: 15303 - New Construction or Conversion of Small Structures Class 3(a+e), Single-family residences not in conjunction with the building of two or more such units. In urbanized areas, up to three single-family residences may be constructed or converted under this exemption. Summary: The applicant, Joyce Ford, is requesting a hillside area construction permit and a front setback variance for a first and second floor addition qualifying as new construction at 2930 Adeline Drive, zoned R-1. This residence is within the area designated as the hillside area by Ordinance 1448 which requires a hillside area construction permit for any addition to all or a portion of an existing residence. This site is located adjacent to Mills Canyon Park. The project qualifies as new construction, therefore a front setback variance is required for 44'-0" (measured to the first and second floors), where 49'-8" (average of block) is required. Present frst floor front setback is 44'-0". The proposed new second floor front setback matches the first floor at 44'-0". The applicant is proposing to add an entry and dining room on the iirst floor (134 SF) and expand an uncovered deck (631 SF). The applicant will be removing the front covered porch (209 SF) to add the entry and dining room. Lot coverage would be increased to 3,671 SF (7%), which includes uncovered decks, exterior stairways and balconies which exceed 30" in height above adjacent grade. The applicant is also proposing a 2,939 SF second floor addition, bringing the total floor area of tt�e house to 5,755 SF (.11 FAR) (including the garage and open spaces 12' or higher and exempting 100 SF of covered porches, CS 25.08.265). The maacimum allowable house size is 8,000 SF (.16 FAR). The areas under the second floor balconies are considered covered porches since they are over an exterior exit from the dwelling (CS 25.08.265, 2). The proposed second story addition matches the footprint of the first floor. The second story addition would provide two uncovered balconies (280 SF), three bedrooms, two and one-half bathrooms, an office Hillside Area Construction Perneil & Front Setback [�arrance 2930 Adeline Drive room and a family room (2,708 SF). A second exit is required on the second floor for any dwelling exceeding 3,000 SF in gross floor living area. The applicant is providing a second exit from the family room on the second floor by way of an exterior stairway. The lot slopes 165' (39 %) downward along the left side property line, 161' (33 %) downward along the right side properly line, and has a cross slope of 14' (23 %) from left to right along the front property line. Because of the slope the top of the second story addition will be a ma�cimum of 4'-3" above the paving edge along Adeline Drive. The existing two bedroom, one and one-half bathroom house is 2,586 SF (.OS FAR) (including the front covered porch and attached garage). The existing house also contains a 632 SF first floor uncovered deck. This project qualifies as New Construction (addition is 95% of the existing gross floor area) and Floor Area Ratio applies. Any single family dwelling qualifying as New Construction must provide off-street parking for at least three vehicles, two of which must be covered. The e�cisting attached garage has a 25'-6" wide X 21'-6" deep clear interior dimension which meets the parking requirement. All other zoning code requirements have been met. The project was called up for review after neighbors within 100' of the property, Planning Commission and City Council were noticed. Several neighbors expressed their concerns in a letter dated February 10, 1998. Their concerns include possible obstruction of long distant views, construction hours and noise and traffic congestion due to construction. '' � ��. D1 *Front Setback (lst): *(2nd): Side Setback (L): (R) : Rear Setback (lst): (2nd): Lot Coverage: Building Height': Parking: no change 44' -0" no change no change no change ±316'-0" 7% (3,671 SF) 4' -31/z " 2 covered, 1 uncovered New Construction: Floor Area Ratio: yes .11 (5,755 SF) EXISTING 44' -0" none 35' -0" 8'-0" ±335'-0" none 6% (3,218 SF) -11'-6" 2 covered, 1 uncovered n/a .OS (2,586 SF) 'Building height is measured from average top of curb to roof ridge. � - � � 1 ' � 1 49'-8" (average) 49' -8" 7' -0" 7' -0" 15'-0" 20' -0" 40 % (8,000 SF) 20'-0" 2 covered, 1 uncovered see code .16 (8,000 SF) 2 Hillside Area Construction Permit & Front Setback Variance H.A.C.P.: Declining Height: Accessory Structures: Fences/Hedges: Trees: *Requires Hillside Area Construction Permit Complies None None No trees to be removed *Hillside Area Construction Permit and front setback variance required. Meets all other zoning code requirements. 2930 Adeline Drive Staff Comments: Planning staff would note that the applicant has addressed the Building Official's and Fire Marshal's comments. 1fie Senior Engineer has suggested that a soils report be provided, but one is not required at this time. Ruben Hurin Zoning Technician c. Joyce Ford, applicant/designer 3