HomeMy WebLinkAbout717 Vernon Way - Staff ReportCity of Burlingame
Design Review Amendment
Address: 717 Vernon Way
Item No.
Regular Action
Meeting Date: January 12, 2009
Request: Design Review Amendment for proposed change to a previously approved first and second
story addition to a single family dwelling.
Applicants and Architect: Daniel Ewald APN: 029-172-050
Property Owners: Barry Sudbeck and Jennifer Hertz Lot Area: 5,027 SF
General Plan: Low Density Residential Zoning: R-1
CEQA Status: The project is Categorica�ly Exempt from review pursuant to the California Environmental
Quality Act (CEQA), per Section: 15301 Class 1(e)(2) of the CEQA Guidelines, which states that additions
to existing structures provided the addition will not result in an increase of more than 10,000 SF in areas
where all public services and facilities are available and the area in which the project is located is not
environmentally sensitive.
History: On October 9, 2007, the Planning Commission approved an application for Design Review for a
first and second story addition to a single family dwelling at 717 Vernon Way, Zoned R-1. On July 14,
2008, the Planning Commission approved an application for Design Review Amendment for changes to
the previously approved first and second story addition (July 14, 2008, P�anning Commission Minutes). A
building permit was issued on June 5, 2008, and the project is currently under construction.
Proposed Revisions: The applicant is now requesting an Amendment to Design Review for a proposed
change to a previously approved first and second story addition at 717 Vernon Way, Zoned R-1. The
applicant is requesting a 77 SF "home office" addition to the proposed master bedroom suite on the
second story at the back of the house (see proposed plans, date stamped December 9, 2008). With the
proposed revision, the project would be 373.3 SF below the maximum allowed FAR. The applicant also
submitted a letter indicating their intent to increase the size of the second story and full sets of revised
plans to the Planning Division on December 9, 2008. Other than the increase in the FAR calculation, all
proposed building materials, window types and landscaping are consistent with the originally approved
plans. The applicant is requesting the following application:
• Design Review Amendment for proposed change to a previously approved first and second story
addition.
Summary (includes proposed revisions): The existing single-story house with a detached one-car
garage contains 1,765.4 SF (0.35 FAR) of floor area and has three bedrooms. The applicant is proposing
to add 125 SF at the back of the existing first floor and to build a new 633 SF second story. With the
proposed remodel and addition, the floor area will increase from 1,765.4 SF to 2,537 SF (0.50 FAR) where
2,910.3 SF (0.58 FAR) is the maximum allowed (proposed project is 373.3 SF below the maximum allowed
FAR).
There is no increase proposed to the number of potential bedrooms with the addition (three existing). Two
parking spaces, one of which must be covered, are required on site. The existing detached one-car
garage (9'-1" x 19' clear interior dimensions) is non-conforming in both length and width, but because no
work is proposed to the detached garage it may remain as non-conforming. One uncovered parking space
(9' x 20') is provided in the driveway to comply with the on-site parking requirements. All other zoning code
requirements have been met. The following application was originally approved with the project:
■ Design Review for a first and second story addition (C.S. 25.57.010, 5).
Design Review Amendment
717 Vernon Way
Lot Area: 5,027 SF
SETBACKS
Fronf (1" flr):
(2"d flr):
Side (left):
(right):
_
Rear(15� flr):
_.
(2"d flr):
Lof Coverage:
FAR:
# of bedrooms:
_ _
Parking:
_ _
Height:
DH Envelope: � Dormer exemption
7/14/08
APPROVAL
17'-4" (to trellis)
33'-10"
14'-1" (to 2"d flr)
4'-0"
27'-9"
44'-2"
__ _.
1,912 SF
38%
_ 2,460 SF
0.49 FAR
_ __ 3 _
1 covered
(9'-1" x 19')Z
1 uncovered
(9' x 20')
25'-7"
Plans date
REVISED
PROPOSAL
no change
no change
no change
43'-6"
no change
2,537 SF '
0.50 FAR '
no change
__
no change ;
no change
no change
717 Vernon Way
d: December 9, 2008
ALLOWED/
REQUIERD
15'-0"
20'-0"
4'-0"
4'-0"
� 5,_�,. .
20'-0"
2,011 SF
40°/a
2,910.3 SF'
0.58 FAR
_
1 covered
(10' x 20')
1 uncovered
(9' x 20')
30'-0"
see code
' (0.32 x 5,027 SF) + 1100 SF + 201.7 SF = 2,910.3 SF (0.58 FAR).
Z Existing nonconforming covered parking space dimensions (9'-1" x 19' existing and proposed where 10' x 20' is
the minimum required).
Staff Comments: Staff comments for the originally approved project are attached to the staff report.
Design Review Criteria: The criteria for Design Review as established in Ordinance No. 1591 adopted by
the Council on April 20, 1998 are outlined as follows:
1
2
3
4
5
Compatibility of the architectural style with that of the existing character of the neighborhood;
Respect for the parking and garage patterns in the neighborhood;
Architectural style and mass and bulk of structure;
Interface of the proposed structure with the structures on adjacent properties; and
Landscaping and its proportion to mass and bulk of structural components.
Planning Commission Action: The Planning Commission should conduct a public hearing on the
application, and consider public testimony and the analysis contained within the staff report. Action should
include specific findings supporting the Planning Commission's decision, and should be affirmed by
resolution of the Planning Commission. The reasons for any action should be stated clearlyforthe record.
At the public hearing the following conditions should be considered:
1. that the project shall be built as shown on the plans submitted to the Planning Department date
stamped December 9, 2008, sheets A1.0 through A3.3, and that any changes to building materials,
exterior finishes, footprint or floor area of the building shall require an amendment to this permit;
2
Design Review Amendment 717 Vernon Way
2. that the conditions of the Chief Building Official's June 17, 2008 and July 3, 2007 memos, the Fire
Marshall's June 16, 2008 and July 5, 2007 memos, the NPDES Coordinator's June 16, 2008 and
July 5, 2007 memos and the City Engineer's June 16, 2008 and July 9, 2007 memos shall be met;
3. that demolition or removal of the existing structures and any grading or earth moving on the site
shall not occur until a building permit has been issued and such site work shall be required to
comply with all the regulations of the Bay Area Air Quality Management District;
4. that any changes to the size or envelope of the basement, first or second floors, or garage, which
would include adding or enlarging a dormer(s), moving or changing windows and architectural
features or changing the roof height or pitch, shall be subject to Planning Commission review;
5. that prior to issuance of a building permit for construction of the project, the project construction
plans shall be modified to include a cover sheet listing all conditions of approval adopted by the
Planning Commission, or City Council on appeal; which shall remain a part of all sets of approved
plans throughout the construction process. Compliance with all conditions of approval is required;
the conditions of approval shall not be modified or changed without the approval of the Planning
Commission, or City Council on appeal;
6. that all air ducts, plumbing vents, and flues shall be combined, where possible, to a single
termination and installed on the portions of the roof not visible from the street; and that these
venting details shall be included and approved in the construction plans before a Building permit is
issued;
7. that the project shall comply with the Construction and Demolition Debris Recycling Ordinance
which requires affected demolition, new construction and alteration projects to submit a Waste
Reduction plan and meet recycling requirements; any partial or full demolition of a structure,
interior or exterior, shall require a demolition permit;
8. that the project shall meet all the requirements of the California Building and Uniform Fire Codes,
2001 Edition, as amended by the City of Burlingame;
THE FOLLOWING CONDITIONS SHALL BE MET DURING THE BUILDING INSPECTION PROCESS
PRIOR TO THE INSPECTIONS NOTED IN EACH CONDITION:
9. that prior to scheduling the framing inspection the project architect or residential designer, or
another architect or residential design professional, shall provide an architectural certification that
the architectural details shown in the approved design which should be evident atframing, such as
window locations and bays, are built as shown on the approved plans; architectural certification
documenting framing compliance with approved design shall be submitted to the Building Division
before the final framing inspection shall be scheduled;
10. that prior to scheduling the roof deck inspection, a licensed surveyor shall shoot the height of the
roof ridge and provide certification of that height to the Building Department; and
11. that prior to final inspection, Planning Department staff will inspect and note compliance of the
architectural details (trim materials, window type, etc.) to verify that the project has been built
according to the approved Planning and Building plans.
Erica Strohmeier
Associate Planner
c. Daniel Ewald, applicants and architect.
[c?
Design Review Amendment
Attachments:
Application to the Planning Commission
ApplicanYs letter of explanation, dated December 9, 2008
July 14, 2008 Planning Commission RegularAction Minutes
Approval Letter for Design Review Amendment, dated July 25, 2008
Staff Comments
Planning Commission Resolution (Proposed)
Notice of Public Hearing — Mailed December 30, 2008
Aerial Photo
717 Vernon Way
C�