HomeMy WebLinkAbout701 Vernon Way - Staff ReportPROJECT LOCATION
701 Vernon Way
Item #
Consent Calemdar
City of Burlingame Item # Zb
Consent Calendar
Desig�a Review, Special Permit a�zd Parki�zg Varia�zce
Address: 701 Vernon Way Meeting Date: 3/13/06
Request: Design review, special pennit and parking variance for a first and second story addition
with an attached garage.
Applicant and Architect: Randy Grange, TRG Architects APN: 029-172-080
PropertV Owner: Jeffrey Bashaw Lot Area: 4979 SF
General Plan: Low Density Residential Zoning: R-1
CEQA Status: Article 19. Categorically Exempt per Section: 15301 Class 1(e)(1) - additions to
existing structures provided the addition will not result ui an increase of more than 50% of the floor
area of the structures before the addition.
Summary: This site is located at the corner of Vernon Way and Bloomfield Road. The existing single
story house with a detached garage contains 1,772 SF (0.36 FAR) of floor area and has two bedrooms.
The applicant is proposing a first floor addition (268 SF) and a new second floor (584 SF). The first
floor addition would connect the rear of the house to the existing garage and therefore requires a
special permit for an attached garage (a portion of the garage will be removed to comply with the rear
setback requirement of 15'-0"). With the proposed addition, the floor area will increase from 1,772 SF
(0.36 FAR) to 2,482 SF (0.50 FAR) where 2,493 SF (0.50 FAR) is the maximum allowed (includes
porch and chimney exemptions) (project is 11 SF below the maximum ailowed FAR). Planning staff
would note that for setback purposes, the frontage along Vernon Way is considered to be the lot front
since it is the shorter street frontage.
With the addition, the number of bedrooms will increase from two to three. Two parking spaces, one
of which must be covered, are required on site. The existing on-site parking is nonconforming since
only one parking space (covered, 10' x 20' clear interior dimensions) is provided. There is 10' in the
driveway (as measured to the edge of sidewalk), but it does not meet the uncovered 9' x 20' minimum
requirement. There are no changes to the number of on-site parking spaces with this application.
Therefare, a parking variance is required for one on-site parking space where two spaces are required
for increasing the number of bedrooms in the house from two to three. All other zoning code
requirements have been met. The applicant is requesting the following:
• Design Review for a first and second story addition (CS 25.57.010, a, 5);
• Special permit for an attached one-car garage (CS 25.28.035, a); and
Parking variance for number of on-site spaces (one parking space existing and provided
(covered); no uncovered on-site parking is provided) (CS 25.70.030, b).
Design Review, Special Pe�mit anrl Parking Variance
701 Vernon Way
701 Vernon Way
Lot Area: 4979 SF Plans date stam ed: Janua 25 and March 1, 2006
Existing Proposed Allowed/Required
SETBACKS
____ _ _. .. _ . ...._._ __...... _ _.. _.. _.._.._. _._.._._
Front (Ist flr): 15'-0" (Vernon Way) no change 15'-0"
(2nd flr): none 48'-8" 20'-0"
__ _... _ _._ - _ _. _; . ... _ _.... _...._.
Side (interior): 3'-8"' 18'-11" 4'-0"
(exterior —1 S` flr): 4'-9"2 8'-0" 7'-6"
(exterior — 2id flr): none average of 12'-0" average of 12'-0"
- __ , -_ . .__._._ _...; _.... .. ..
Rear (Ist flr): 39'-2" to house 15'-0" 15'-0"
(2�id flr): none 20'-0" 20'-0"
_ _ __. __... ... _ _ ..___ __-- _ _ _.._._.. ; _ .
�
Lot Coverage: 1772 SF 1988 SF 1992 SF
35.5% 39.9% 40%
FAR: 1772 SF 2482 SF 2493 SF
0.36 FAR 0.50 FAR 0.50 FAR
# of bedrooms: 2 3 ---
Parking: 1 covered 1 covered 1 covered
�io� X 20�� �io� X 20�� �io� X 20��
0 uncovered' 0 uncovered4 1 uncovered
(9' x 20')
Garage: detached attacheds special permit if
attached
Height: 19'-0" 27'-0" 30'-0"
_.. ___ _.... _ . _...-----+----- -----_ _.._.._ _;. .... - -- ____.... _.._.._._.__
DHEnvelope: n/a complies see code
' Existing nonconforming interior side setback (3'-8" existing where 4'-0" is required).
z Existing nonconforming exterior side setback (4'-9" existing where 7'-6" is required).
3 Existing nonconforming on-site parking (one on-site parking space existing where a minimum of
two parking spaces are required).
4 Parking variance for number of on-site spaces (one parking space existing and provided (covered)
where a minimum of two parking spaces are required) (CS 25.70.030, b).
' Special permit for an attached one-car garage (CS 25.28.035, a).
Staff Comments: See attached.
2
Desigrr Rew�ew, Specia[ Perr��it anrl Pm•king Variance
701 �ernori Wci��
Design Review Study Meeting: At the Plarming Commission design review study meeting on
February 13, 2006, the Commission suggested several changes to the project and placed this item on
the consent calendar (February 13, 2006 Planning Commission Minutes).
The architect submitted a response letter and revised plans (sheets A-4 tlu-ough A-6), date stamped
March 1, 2006. Listed below are the Commissions' suggestions and responses by the applicant.
1. Are tlze proposed Fre�zcJt doors iiz tlae garage going to be 7'-6" tall?
• The revised plans show the French doors at the rear of the garage increased in height from 7'-6"
to 8'-0" and the side access doar decreased in height from 7'-6" to 6'-8" (see revised building
elevations sheets A-5 and A-6).
2. O�7 tlte existing front
existiiig windows are
changed, clarify.
elevation, two different wi�idow patterns are sltown, pla�zs note that
to reiraain, but shoivs differeiit fnullions, will the existi�ig windows be
• The existing windows will be replaced with new windows. The style and mullion pattern will
be consistent throughout the house (see revised building elevations).
3. Look at sca[e of wii:dow i�z t/ze stairwell, look at clza�zging to tlrree separatecl vertical paiaels, tl�e
large window proposed co�ztribute to the large mass of the stairwe[I.
• The size and style of the window in the stairwell was not changed. However, to address the
Commissions' concern about the mass of the stairwell, the roof configuration at the stairwell
and garage was revised from gable to hip (see revised building elevations). In addition, the
plate height of the stairwell was reduced by approximately 1'-0" from 8'-0" to 7'-0".
4. Might want to consider addi�zg a window in the di�zi�zg room facing the neiglzbor on Vernon,
woarld be nice for tJze dini�zg area mid break i�p tlze wall for tlie i�eiglzbor.
• In his letter dated February 28, 2006, the architect notes that the property owners considered
adding a window in the dining room, but decided not to because it is not part of the addition
area and would not otherwise be impacted. In addition, the wall is used for cabinetry and there
would be no view from this window.
S. SlTotrld co�zsider pa�tting a gated fence for tlie kids to put tlieir bikes in tlze back ya►�d.
• A gated fence was incorporated into the project (see revised Left Elevation, sheet A-4).
3
Desigri Review, Special Permit and Parking Variarzce 701 Vernon Way
Design Review Criteria: The critena for design review as established in Ordinance No. 1591 adopted
by the Council on April 20, 1998 are outlined as follows:
Compatibility of the architectural style with that of the existing character of the neighborhood;
2. Respect for the parking and garage patterns in the neighborhood;
3. Architectural style and mass and bulk of structure;
4. Interface of the proposed structure with the structures on adjacent properties; and
5. Landscapiilg and its proportion to mass and bulk of structural coinponents.
Findings: Based on the findings stated in the attached minutes of the Plaruling Cominissio�'s February
13, 2006, design review study meeting, that the first and second floor addition is well-designed and
will improve the character of the block and enhance the design of the community, the project is found
to be compatible with the requirements of the City's five design review guidelines.
Findings for a Special Permit: In order to grant a special permit for an attached garage, the Planning
Gommission must find that the following conditions exist on the property (Code Section 25.51.020 a-
d):
(a) The blend of inass, scale and dominant structural characteristics of the new construction or
addition are consistent with the existing structure's design and with the existing street and
neighborhood;
(b) the variety of roof line, facade, exterior finish materials and elevations of flie proposed new
structure or addition are consistent with the existing structure, street and neighborhood;
(c) the proposed project is consistent with the residential design guidelines adopted by the city; aild
(d) removal of any trees located within the footprint of any new structure or addition is necessary
and is consistent with the city's reforestation requirements, and the mitigation for the removal
that is proposed is appropriate.
Special Permit Findings for Attached Garage: Based on the findings stated in the attached minutes
of fl1e Planning Commission's February 13, 2006, public meeting, that the existing garage will be
reduced in size by 82 SF, that the first floor addition would connect the rear of the house to the existing
detached garage which will remain in its existing location at the rear of the lot, that the attached on-car
garage will be setback 15'-0" from the rear property line which complies with zoning code
requirements, and that the attached garage is consistent with the design of the house, the project is
found to be compatible with the special permit criteria listed above.
n
Design Review, Special Permit and Parking Variance 701 Vernon Way
Required Findings for Variance: In order to grant a parking variance for number of on-site spaces
(one parking space existing and provided (covered) where a minimum of two parking spaces are
required), the Planning Commission must find that the following conditions exist on the property
(Code Section 25.54.020 a-d):
(a) there are exceptional or extraordinary circumstances or conditions applicable to the property
involved that do not apply generally to property in the same district;
(b) the granting of the application is necessary for the preservation and enjoyment of a substantial
property right of the applicant, and to prevent unreasonable property loss or unnecessary
hardship;
(c) the granting of the application will not be detrimental or injurious to property ar improvements
in the vicinity and will not be detrimental to the public health, safety, general welfare or
convenience;and
(d) that the use of the property will be compatible with the aesthetics, mass, bulk and character of
existing an potential uses of properties in the general vicinity.
Findings for Parking Variance: Based on the findings stated in the attached minutes of the Planning
Commission's February 13, 2006, public meeting, that the existing house was built on this corner lot
with an 8'-0" long driveway and without an uncovered parking space, that the back of the existing
house would have to be demolished to provide an uncovered parking space, and that additional street
parking is provided on this corner lot with two street frontages and a narrow curb cut along one side,
the project is found to be compatible with the variance criteria listed above.
Planning Commission Action: The Planning Commission should hold a public hearing. Affirmative
action should be by resolution and include findings made for design review, special permit and parking
variance. The reasons for any action should be clearly stated. At the public hearing the following
conditions should be considered:
that the project shall be built as shown on the plans submitted to the Planning Department date
stamped January 25, 2006, sheets A-1 through A-3, and date stamped March 1, 2006, sheets A-
4 through A-6, and that any changes to building materials, exteriar finishes, footprint or floor
area of the building shall require an amendment to this permit;
2. that any changes to the size or envelope of the basement, first or second floors, or garage, which
would include adding or enlarging a dormer(s), moving or changing windows and architectural
features or changing the roof height or pitch, shall be subject to Planning Commission review;
3. that prior to scheduling the framing inspection, the project architect, engineer or other licensed
professional shall provide architectural certification that the architectural details such as
window locations and bays are built as shown on the approved plans; if there is no licensed
5
Design Review, Specia[ Permit and Parking Variance
701 vernon i7�ay
professional involved in the project, the property owner or contractor shall provide the
certification under penalty of perjury;
4. that prior to scheduling the roof deck inspection, a licensed surveyor shall shoot the height of
the roof ridge and provide certification of that height;
5. that prior to final inspection, Planning Department staff will inspect and note compliance of the
architectural details (trim materials, window type, etc.) to verify that the project has been built
according to the approved Planning and Building plans;
6. that all air ducts, plumbing vents, and flues shall be combined, where possible, to a single
termination and installed on the portions of the roof not visible from the street; and that these
venting details shall be included and approved in the construction plans before a Building
permit is issued;
7. that the conditions of the City Engineer's, Chief Building Official's and Recycling Specialist's
October 31, 2005, memos, the Fire Marshal's October 28, 2005, memo and the NPDES
Coordinator's October 27, 2006, memo shall be met;
8. that the project shall comply with the Construction and Demolition Debris Recycling Ordinance
which requires affected demolition, new construction and alteration projects to submit a Waste
Reduction plan and meet recycling requirements; any partial or full demolition of a structure,
interior or exterior, shall require a demolition permit;
9. that the project shall meet all the requirements of the California Building and Uniform Fire
Codes, 2001 Edition, as amended by the City of Burlingame; and
10. that the applicant shall comply with Ordinance 1503, the City of Burlingame Storm Water
Management and Discharge Control Ordinance.
Ruben Hurin
Planner
c. Randy Grange, TRG Architects, applicant and architect
C�
City of Burlingame
Desigia Review, Special Permit a�zd Parki�zg Varimzce
Item # ��
Design Review Study
Address: 701 Vernon Way Meeting Date: 2/13/06
Request: Design review, special permit and parking variance for a first and second story addition
with an attached garage.
Applicant and Architect: Randy Grange, TRG Architects
Property Owner: Jeffrey Bashaw
General Plan: Low Density Residential
APN: 029-172-080
Lot Area: 4979 SF
Zoning: R-1
Summary: This site is located at the corner of Vernon Way and Bloomfield Road. The existing single
story house with a detached garage contains 1,772 SF (0.36 FAR) of floor area and has two bedrooms.
The applicant is proposing a first floor addition (268 SF) and a new second floor (584 SF). The first
floor addition would connect the rear of the house to the existing garage and therefore requires a
special pennit for an attached garage (a portion of the garage will be removed to comply with the rear
setback requirement of 15'-0"). With the proposed addition, the floor area will increase from 1,772 SF
(0.36 FAR) to 2,482 SF (0.50 FAR) where 2,493 SF (0.50 FAR) is the maximum allowed (includes
porch and chimney exemptions) (project is 11 SF below the maximum allowed FAR). Planning staff
would note that for setback purposes, the frontage along Vernon Way is considered to be the lot front
since it is the shorter street frontage.
With the addition, the number of bedrooms will increase from two to three. Two parking spaces, one
of which must be covered, are required on site. The existing on-site parking is nonconforming since
only one parking space (covered, 10' x 20' clear interior dimensions) is provided. There is 10' in the
driveway (as measured to the edge of sidewalk), but it does not meet the uncovered 9' x 20' minimum
requirement. There are no changes to the number of on-site parking spaces with this application.
Therefore, a parking variance is required for one on-site parking space where two spaces are required
for increasing the number of bedrooms in the house from two to three. All other zoning code
requirements have been met. The applicant is requesting the following:
• Design Review for a first and second story addition (CS 25.57.010, a, 5);
� Special permit for an attached one-car garage (CS 25.28.035, a); and
Parking variance for number of on-site spaces (one parking space existing and provided
(covered) where a minimum of two parking spaces are required) (CS 25.70.030, b).
701 Vernon Way
Lot Area: 4979 SF
Existing
SETBACKS
Plans date
Proposed
Fro�it (lst flr): 15'-0" (Vernon Way) ; no change
(2nd flr): none � 48'-8"
: January 25, 2006
Allowed/Required
15'-0"
20'-0"
Design Review, Special Pe�-nrit and Pcn-kntg Vai•ianee
701 Vernon Way
70! Vernon Way
Lot Area: 4979 SF Plans date stam ed: Januar � 25, 2006
Existing '; Proposed Allowed/Required
Side (interior): 3'-8"' ' 18'-11" ' 4'-0"
(exterior —1 S` flr): 4'-9"z 8'-0" 7'_6"
(e_rterior — 2"d flr): none average of 12'-0" ', average of 12'-0"
__ _ __ _ . ; _ _
Rear (Ist flr): 39'-2" to house 15'-0° 15'-0"
(2�td flr): none 20'-0" 20'-0"
_.. __ _. _ __ _. :. _
Lot Coverage: 1772 SF 1988 SF 1992 SF
35.5% 39.9% ' 40%
_ __ _ _ _. __ _
FAR: 1772 SF 2482 SF ' 2493 SF
036 FAR ' 0.50 FAR ' 0.50 FAR
_ . _
# of bedroonis: 2 ' 3 ', ---
__ _ __. _ __ _.. i _............
Parking: 1 covered 1 covered 1 covered
�lo� X zo�) (io� X zo') (lo� X zo')
0 uncovered3 0 uncovered`� 1 uncovered
: (9' x 20')
Garage: detached attached5 special permit if
attached
_ _ __ _ __ _. ; _ _
Height: 19'-0" 27'-0" 30'-0"
DHE�rve[ope: n/a complies see code
' Existing nonconfornling interior side setback (3'-8" existing where 4'-0" is required).
2 Existing nonconforming exterior side setback (4'-9" existing where 7'-6" is required).
' Existing nonconforming on-site parking (one on-site parking space existing where a miniinum of
two parking spaces are required).
� Parking variance for number of on-site spaces (one parking space existing and provided (covered)
where a minimum of two parkin� spaces are required) (CS 25.70.030, b).
5 Special permit for an attached one-car garage (CS 25.28.035, a).
Staff Comments: See attached.
Ruben Hunn
Planner
c. Randy Grange, TRG Architects, applicant and architect
2