Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Reso - PC - 2021-03.22-8C
(DocuSJgr, Enveloi,e ID: 7141i276C-216E-4AF9-ACA5-1A01 E30AB5DE RECORDING REQUESTED BY: Planning Department City of Burlingame WHEN RECORDED MAIL TO: COMMUNITY DEVELOPMENT DEPARTMENT CITY OF BURLINGAME 501 PRIMROSE ROAD BURLINGAME, CA 94010 2021-165582 2:29 pm 12/02/21 R1 Fee: NO FEE Count of Pages 3 Recorded in Official Records County of San Mateo Mark Church 1111111111111f 1!iiHt11;11m1�1�1111i1�i1]ijJ111111m11111111111 *$R0003181727$, Resolution No. 2021-03.22-Bc 220 CALIFORNIA DRIVE APN 029-213-020 TITLE OF DOCUMENT I hereby certify this to be a full, true and correct copy of the document it purports to be, the original of which is on file in my office. Date: October 25, 2021 ------�����------ Kevin Gardiner, AICP, Community Development Directo UP UP D A C B 765432 1 A300 2 A300 A200 1 OFFICE 1 101 OFFICE 2 102 OFFICE 3 103 PRINT ROOM 104 COMMUNAL WORKSPACE 100 1 F.O. (E) WALL6' - 11 3/4"11' - 4 1/2"3' - 5 3/4"11' - 11 3/4"16' - 2 3/4"13' - 3 3/4"13' - 0"3' - 11"16' - 2"7' - 0 3/4"6' - 2 7/8" F.O. (E) WALL MATCH LINE, SEE DWG 1/A130 LOUNGE 105 GWB-01 KITCHEN 106 GWB-01 RESTROOM 1 107 GWB-01 107 P02 P01 P04 A A560 C G B BB G A200 3 A410 2 3 A411 7 6 5 8A411 3 2 1 4 A411 11 10 9 12 A411 16 15 14 13 A410 1 A4104 P03 B D 6' - 7"15' - 8"12' - 0 1/2"12' - 0 1/2"12' - 0 1/2"12' - 0 1/2"7' - 7 1/8"3" F.O. (E) COLUMN F.O. (E) COLUMN2 HR RATED ROLL DOWN SHUTTER (E) COLUMN TO BE REMOVED (E) COLUMN TO BE REMOVED (E) COLUMN TO BE REMOVED (N) COLUMN (N) COLUMN (E) COLUMN TO BE REMOVED F.O. (E) COLUMN F.O. (E) COLUMN F.O. (E) COLUMN F.O. (E) COLUMNC.L. (E) COLUMN F.O. (E) COLUMNF.O. (E) WALL(N) COLUMN (N) COLUMN MEZZANINE ABOVE (N) BEAM ABOVE (E) COLUMN TO BE REMOVED EXTEND (E) BEAM ABOVE (E) BEAM ABOVE (N) ROOF ABOVE MEZZ. ABOVE (N) COLUMN (E)(E) (E)(E)(E)(E) (E)(E) 5 EQ EQ EQ EQ 108 105 1 100 2 11" RUN, 7" RISE STAIR 1 A600 6 101 102 103 104 1' - 6"3' - 2"6' - 5 3/4"2' - 5 5/8"A4011 Sim E 5.2 6.5 A H H (E) COLUMN TO BE REMOVED B (N) COLUMN (N) COLUMN 30x48 60" CLR.24" CLR.CLR.24"6 0 " C L R .10' - 8 1/4"C L R .ø 5 ' - 0 "30X48 1 1 1 1 1 D A C B 765432 1 A300 2 A300 A200 1 OPEN TO BELOW LOUNGE 200 1 11' - 11 3/4"16' - 2 3/4"13' - 3 3/4"13' - 0"3' - 11"16' - 2"7' - 0 3/4"6' - 2 7/8"6' - 11 3/4"11' - 4 1/2"3' - 5 3/4"(N) MECHANICAL DUCT A A560 A200 3 OFFICE 4 201 RESTROOM 2 202 WC 203 B H A412 1 4 3 2 A412 5 8 7 6 F.O. (E) WALLF.O. (E) WALL F.O. (E) COLUMN F.O. (E) COLUMNF.O. (E) COLUMN F.O. (E) COLUMN F.O. (E) COLUMN F.O. (E) COLUMNC.L. (E) COLUMN F.O. (E) COLUMNF.O. (E) WALLH (N) BEAM (N) BEAM (E) BEAM EXTEND (E) BEAM ABOVE (E) COLUMN TO BE REMOVED (E) COLUMN TO BE REMOVED (N) COLUMN (N) COLUMN (E) (E) (E)(E)(E)(E) (E)(E) (N) PARAPET (N) PARAPET 4' - 0"CLR.2' - 4 1/2"P20 P21 P22 201 202 203 204 B G B A 11" RUN, 7" RISE STAIR 1 2 HR RATED ROLL DOWN SHUTTER MATCH LINE10' - 6 3/4"12' - 6 1/2"14' - 2 5/8" A600 6 6' - 10"2' - 6 1/4"(N) BEAM, TYP. (N) BEAM, TYP. (N) COLUMN A4021 Sim 5.2 6.5 10 A510 LEGEND: (N) WALL/PARTITION (E) CONCRETE WALL (E) CMU WALL (E) WALL/PARTITION X X X PARTITION TYPE DOOR REFERENCE WINDOW REFERENCE PROJECT: DATE: SCALE: STANDARD® LLP 4411 SANTA MONICA BLVD LOS ANGELES, CA 90029 INFO@STANDARDARCHITECTURE.COM TEL: 323 662 1000 ARCHITECT: PROJECT: AS NOTED ©2020 ALL RIGHTS RESERVED A101 220 California Dr Burlingame, CA 94010 CALIFORNIA DRIVE 12.14.20 PLAN CHECK SUBMITTAL 02.10.21 PLANNING CORRECTIONS∆1 2011 FLOOR PLANS 02/10/2021 SCALE: 1/4" = 1'-0"1ENLARGED FLOOR PLAN PLAN NOTES: 1. ALL DIMENSIONS ARE TO FACE OF STUD OR SHEATHING UNLESS OTHERWISE NOTED. 2. READ IN CONJUNCTION WITH STRUCTURAL, ELECTRICAL, AND MECHANICAL DRAWINGS; REPORT ANY DISCREPANCIES TO ARCHITECT FOR CLARIFICATION PRIOR TO PROCEEDING WITH AFFECTED AREA OF THE WALL. 3. CONTRACTOR SHALL VERIFY SIZE AND LOCATION OF DUCT OPENINGS AND PLUMBING RUNS WITH MECHANICAL AND PLUMBING SUBCONTRACTORS BEFORE FRAMING OPENINGS IN WALLS, FLOORS, CEILINGS, ROOF, ETC. 4. PROVIDE & LOCATE ACCESS DOORS AND PANELS IN WALL AND CEILING CONSTRUCTION AS REQUIRED TO PROVIDE ACCESS TO MECHANICAL, FIRE SPRINKLER, PLUMBING AND ELECTRICAL WORK. CONTRACTOR SHALL SUBMIT PLAN OF ALL PROPOSED ACCESS PANEL LOCATIONS TO ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. 5. ALL PLUMBING CLEANOUTS SHALL BE INSTALLED WHERE READILY ACCESSIBLE. CONTRACTOR SHALL COORDINATE LOCATION OF ALL CLEANOUTS WITH EQUIPMENT AND CABINETS. SUBMIT A PLAN OF CLEANOUT LOCATIONS TO ARCHITECT FOR APPROVAL PRIOR TO INSPECTION. 6. PROVIDE AND INSTALL STIFFENERS, BRACING, BACK UP PLATES, AND/ OR SUPPORTING BRACKETS AS REQUIRED FOR THE INSTALLATION OF WALL MOUNTED OR SUSPENDED EQUIPMENT OR ACCESSORIES. 7. ANY CORE, DEMISING, FIRE RESISTANT PARTITIONS EXISTING TO REMAIN ARE TO BE IMMEDIATELY REPAIRED TO RESTORE RATING OF WALL. THIS INCLUDES PATCHING OF ANY EXISTING FIREPROOFING THAT HAS BEEN DISTURBED ON ANY STRUCTURAL ELEMENTS (BEAMS, COLUMNS). PATCHING OF FIREPROOFING MUST BE OF EQUIVALENT RATING TO MATCH EXISTING. 8. ALL BLOCKING, PLYWOOD, AND REINFORCEMENT TO BE FIRE- RTARDANT-TREATED. 9. BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR ROOMS SHALL BE PROVIDED WITH ARTIFICIAL LIGHT AND A MECHANICAL VENTILATION OF 50 CFM INTERMITENT OR 25 CFM CONTINUOUS VENTILATION. 10. ALL DUCTWORK & PLUMBING RUNS TO BE ABOVE FINISHED CEILING UNLESS OTHERWISE NOTED. SCALE: 1/4" = 1'-0"2ENLARGED MEZZANINE PLAN UP UP 8 D A C B 76 3 A300 9 7' - 0 3/4"6' - 2 7/8"15' - 9 1/4"14' - 0 5/8" F.O. (E) WALL F.O. (E) WALLF.O. (E) WALL3' - 5 3/4"11' - 4 1/2"6' - 11 3/4"(N) ROLL-UP GATE C.L. (E) COLUMNF.O. (E) COLUMNF.O. (E) COLUMN F.O. (E) COLUMNF.O. (E) COLUMN2 HR RATED ROLL DOWN SHUTTER (E) COLUMN TO BE REMOVED (E) COLUMN TO BE REMOVED EXTEND (E) BEAM ABOVE A200 2 (N) GAS AND WATER METER LOCATIONS (E) (E)(N) (N) (N) MOMENT FRAME WAREHOUSE 108 4 A300 109 (N) EXIT DOOR RELOCATED ELECTRICAL PANEL MATCH LINE, SEE DWG 1/A101 11" RUN, 4 1/2" RISE STAIR 2 -0-3 1/2" 0'-0" -1-1 1/2" -1-1 1/2" -1-0 1/4" 1% SLOPE 2% SLOPE -0 -3 3/4" 60" -1-0 1/2" 1% SLOPE 1% SLOPE 110 105 6.5 A413 1 4 3 2 3"3"3"A5052 Sim S I D E W A L K7' - 0 "60" CLR.24" CLR.60" CLR.24" CLR.(N) SEWER CLEANOUT LOCATION 1 ? 8 D A C B 76 9 F.O. (E) WALL F.O. (E) WALLF.O. (E) WALL7' - 0 3/4"6' - 2 7/8"15' - 9 1/4"14' - 0 5/8" C.L. (E) COLUMNF.O. (E) COLUMNF.O. (E) COLUMN F.O. (E) COLUMNF.O. (E) COLUMN(N) MOMENT FRAME EXTEND (E) BEAM 3' - 5 3/4"11' - 4 1/2"6' - 11 3/4"MATCH LINE, SEE DWG 1/A111 E22 HR RATED ROLL DOWN SHUTTER 6.5 8 D A C B 76 9 F.O. (E) WALL F.O. (E) WALLF.O. (E) WALL7' - 0 3/4"6' - 2 7/8"15' - 9 1/4"14' - 0 5/8"3' - 5 3/4"11' - 4 1/2"6' - 11 3/4"C.L. (E) COLUMNF.O. (E) COLUMNF.O. (E) COLUMN F.O. (E) COLUMNF.O. (E) COLUMNMATCH LINE, SEE DWG 1/A120 DEDICATED FIRE SHUTTER MOTOR OUTLET 115V 6.5 8 D A C B 76 9 7' - 0 3/4"6' - 2 7/8"15' - 9 1/4"14' - 0 5/8" (E) ROOF EXTENSION 5' - 7 5/8" (E) SKYLIGHT (E) SKYLIGHT (E) SKYLIGHT (E) SLOPE (E) SLOPE (E) SLOPE AT RF. EXTENSION (E) SLOPE AT RF. EXTENSION (E) BLOCK PARAPET3' - 5 3/4"11' - 4 1/2"6' - 11 3/4"MATCH LINE, SEE DWG 1/A102 (E) LOWER ROOFEXTENDED LOWER ROOF F.O. (E) WALL F.O. (E) WALLF.O. (E) WALLC.L. (E) COLUMNF.O. (E) COLUMNF.O. (E) COLUMN F.O. (E) COLUMNF.O. (E) COLUMN6.5 APPROX. (E) IN-WALL DRAIN LOCATION, TYP. (E) DOWNSPOUT TO REMAIN(N) ROOF DRAIN W/ OVERFLOW, TYP. 1 1 PROJECT: DATE: SCALE: STANDARD® LLP 4411 SANTA MONICA BLVD LOS ANGELES, CA 90029 INFO@STANDARDARCHITECTURE.COM TEL: 323 662 1000 ARCHITECT: PROJECT: AS NOTED ©2020 ALL RIGHTS RESERVED A130 220 California Dr Burlingame, CA 94010 CALIFORNIA DRIVE 12.14.20 PLAN CHECK SUBMITTAL 02.10.21 PLANNING CORRECTIONS∆1 2011 WAREHOUSE FLOOR AND ROOF PLANS 02/10/2021 SCALE: 1/4" = 1'-0"1(N) WAREHOUSE FLOOR PLAN SCALE: 1/4" = 1'-0"3(N) WAREHOUSE RCP SCALE: 1/4" = 1'-0"4(N) WAREHOUSE POWER & DATA PLAN PLAN NOTES: 1. ALL STAIRWAYS SHALL HAVE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT-CANDLE (11LUX). (CBC 1205.4) 2. ALL DIMENSIONS ARE TO FACE OF STUD OR SHEATHING UNLESS OTHERWISE NOTED. 3. READ IN CONJUNCTION WITH STRUCTURAL, ELECTRICAL, AND MECHANICAL DRAWINGS; REPORT ANY DISCREPANCIES TO ARCHITECT FOR CLARIFICATION PRIOR TO PROCEEDING WITH AFFECTED AREA OF THE WALL. 4. CONTRACTOR SHALL VERIFY SIZE AND LOCATION OF DUCT OPENINGS AND PLUMBING RUNS WITH MECHANICAL AND PLUMBING SUBCONTRACTORS BEFORE FRAMING OPENINGS IN WALLS, FLOORS, CEILINGS, ROOF, ETC. 5. PROVIDE & LOCATE ACCESS DOORS AND PANELS IN WALL AND CEILING CONSTRUCTION AS REQUIRED TO PROVIDE ACCESS TO MECHANICAL, FIRE SPRINKLER, PLUMBING AND ELECTRICAL WORK. CONTRACTOR SHALL SUBMIT PLAN OF ALL PROPOSED ACCESS PANEL LOCATIONS TO ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. 6. ALL PLUMBING CLEANOUTS SHALL BE INSTALLED WHERE READILY ACCESSIBLE. CONTRACTOR SHALL COORDINATE LOCATION OF ALL CLEANOUTS WITH EQUIPMENT AND CABINETS. SUBMIT A PLAN OF CLEANOUT LOCATIONS TO ARCHITECT FOR APPROVAL PRIOR TO INSPECTION. 7. PROVIDE AND INSTALL STIFFENERS, BRACING, BACK UP PLATES, AND/ OR SUPPORTING BRACKETS AS REQUIRED FOR THE INSTALLATION OF WALL MOUNTED OR SUSPENDED EQUIPMENT OR ACCESSORIES. 8. HABITABLE SPACE, HALLWAYS, BATHROOMS, TOILET ROOMS, AND LAUNDRY ROOMS SHALL HAVE CEILING HEIGHT OF NO LESS THAN 7-FT. (R305.1) 9. BATHROOM SHALL HAVE A CEILING HEIGHT OF NO LESS THAN 6-FT. 8-IN. AT THE CENTER OF FRONT CLEARANCE AREA FOR FIXTURES. (R305.1 EX 2) 10. BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR ROOMS SHALL BE PROVIDED WITH MINIMUM GLAZED AREA OF 3-SF, ONE- HALF OF WHICH IS OPENABLE. THE GLAZED AREAS ARE NOT REQUIRED WHERE ARTIFICIAL LIGHT AND A MECHANICAL VENTILATION OF 50 CFM INTERMITTENT OR 25-CFM CONTINUOUS VENTILATION ARE PROVIDED. (R303.3) 11. AGGREGATE GLAZING AREA OF HABITABLE ROOMS MUST BE A MINIMUM OF 8% OF THE ROOM FLOOR AREA. EXCEPTIONS:SCALE: 1/4" = 1'-0"2(N) WAREHOUSE ROOF PLAN 8 D A C B 76 3 A300 9 A200 2 4 A3006.5 A413 1 4 3 2 MATCH LINE S I D E W A L K W I D T H7' - 0 " 4 0 ' - 0 " (E) SIDE WALK TO REMAIN WEST LANEPROJECT: DATE: SCALE: STANDARD® LLP 4411 SANTA MONICA BLVD LOS ANGELES, CA 90029 INFO@STANDARDARCHITECTURE.COM TEL: 323 662 1000 ARCHITECT: PROJECT: AS NOTED ©2020 ALL RIGHTS RESERVED A131 220 California Dr Burlingame, CA 94010 CALIFORNIA DRIVE 02.10.21 PLANNING CORRECTIONS∆1 2011 VEHICLE MANEUVER DIAGRAM 02/10/2021 SCALE: 1/4" = 1'-0"1VEHICLE MANEUVER DIAGRAM 1 PROJECT SITE: 220 CALIFORNIA DR. CALIFO RNIA DR EL CAMINO REAL FWY. P E N IN S U LA A V E H O W A R D A V E 1 A777 SIM A777 1 1 11 999 0' - 0" LEVEL SECTIONS SHEET NUMBER DWG NUMBER SHEET NUMBER DWG NUMBER ELEVATIONS DOOR REFERENCE WINDOW REFERENCE 999 PARTITION TYPE X HEIGHT REFERENCE T.O. (E) ROOF 17'-6" T.O. (N) ROOF 2-' 6 1/2" T.O. (E) ROOF 17' - 6" (E) PEDESTRIAN RAMP (E) STREET LIGHT (N) GAS AND WATER METER LOCATION (E ) S I D E W A L K12' - 0 " (N) ROOF ADDITION 220 CA DR. EXISTING BLDG TO REMAIN (N) STOREFRONT SIGN WEST LANENEIGHBORING LOT NEIGHBORING BLDG. PL PL 127' - 8" PROPERTY LENGTH 128' - 10" PROPERTY LENGTH24' - 2" PROPERTY WIDTH24' - 7" PROPERTY WI DTHCA DRIVE(E ) S I D E W A L K7' - 0 " RELOCATED ELECTRICAL PANEL (N) SEWER CLEANOUT LOCATION (E) SIDEWALK TO REMAIN 1 1 1 PROJECT: DATE: SCALE: STANDARD® LLP 4411 SANTA MONICA BLVD LOS ANGELES, CA 90029 INFO@STANDARDARCHITECTURE.COM TEL: 323 662 1000 ARCHITECT: PROJECT: AS NOTED ©2020 ALL RIGHTS RESERVED A000 220 California Dr Burlingame, CA 94010 CALIFORNIA DRIVE 12.14.20 PLAN CHECK SUBMITTAL 02.10.21 PLANNING CORRECTIONS∆1 2011 PROJECT INFORMATION 02/10/2021 PROJECT INFORMATION DIRECTORY SHEET INDEX DESCRIPTION OF WORK APPLICABLE CODES PROJECT DATA ADDRESS LEGAL DESCRIPTION CONSTRUCTION TYPE OCCUPANCY NUMBER OF FLOORS FLOOR AREA GROUND FLOOR MEZZANINE 220 CALIFORNIA DR BURLINGAME, CA 94010 APN: 029-213-020 TRACT: LOT: ARB: BLOCK: 16 TYPE-1 M- RETAIL 1 + MEZZANINE SALES AREA: 1,876 SF BATHROOM: 56 SF STORAGE: 1,017 SF SALES AREA: 718 SF TOTAL: 3,667 SF OWNER: JEMCOR Development Partners ARCHITECT: STANDARD LLP 4411 Santa Monica Blvd. Los Angeles, CA 90029 tel: 323 552 1000 e-mail: info@standardarchitecture.com EXISTING NO CHANGE NO CHANGE NO CHANGE NO CHANGE NO CHANGE NO CHANGE TYPE-1 (NON - SPRINKLERED) B- OFFICE NO CHANGE OFFICE SPACE: 1,700 SF BATHROOM: 65 SF STORAGE: 275 SF WAREHOUSE: 930 SF OFFICE SPACE: 395 SF BATHROOM: 125 SF TOTAL: 3, 490 SF PROPOSED CHANGE OF USE FROM AN EXISTING RETAIL SPACE (M OCCUPANCY) TO OFFICE SPACES (B OCCUPANCY). TENANT IMPROVEMENT, RAISE MEZZANINE CEILING, NEW STORE FRONT OCCUPANT LOAD LEVEL:AREA:OCC. TYPE: FLOOR 1 MEZZANINE 2,040 SF 930 SF 520 SF B S-2 B LOAD FACTOR: 150 SF GROSS 200 SF GROSS 150 SF GROSS TOTAL: OCCUPANT LOAD: 14 5 3 22 PLUMBING CALCULATIONS DESCRIPTION:AREA:OCC. TYPE: OFFICE 2,560 SF B LOAD FACTOR: 200 SF GROSS OCCUPANCY LOAD: 12 (6 MALE, 6 FEMALE) W.C. REQUIRED: 1* URINALS REQUIRED: 0* LAVATORIES REQUIRED: 1* NOTE: 1 DRINKING FOUNTAIN AND 1 SERVICE SINK REQUIRED AND PROVIDED *PER CPC 422.2, EXCEPTION 3A: IN BUSINESS OCCUPANCIES WITH A TOTAL OCCUPANT LOAD OF 50 OR LESS, ONE TOILET FACILITY SHALL BE PERMITTED FOR USE BY BOTH SEXES. PARKING 2,095 SF / 300 SF = 7 REQUIRED SPOTS 930 SF / 1000 SF = 1 REQUIRED SPOT TOTAL PARKING = 8 SPOTS NOTE: PER BMC 25.70.040, 1 SPACE FOR EACH 300 SQ. FT. REQUIRED AT OFFICES NOTE: PER BMC 25.70.040, 1 SPACE FOR EACH 1,000 SQ. FT. REQUIRED AT WAREHOUSES OFFICE AREA FLOOR 1: OFFICE AREA @ MEZZANINE: TOTAL OFFICE AREA: TOTAL WAREHOUSE AREA: REQUIRED PARKING SPOTS:GROSS SQUARE FOOTAGE CALCULATIONS: 1,700 SF 395 SF 2,095 SF 930 SF EXISTING PARKING: 8 SPACES REQUIRED NO SPACES PROVIDED ON EISTING SITE NO ADDITIONAL PARKING REQ'D. PROVIDED PARKING SPOTS: 2020 BURLINGAME MUNICIPAL CODE 2019 CALIFORNIA BUILDING CODE 2019 CALIFORNIA ELECTRICAL CODE 2019 CALIFORNIA MECHANICAL CODE 2019 CALIFORNIA PLUMBING CODE 2019 CALIFORNIA ENERGY CODE SCALE: 1" = 400'-0"1VICINITY MAP MEANS OF EGRESS: TRAVEL DISTANCE:OCCUPANCY: COMMON PATH OF TRAVEL (PER CBC TABLE 1006.2.1): FLOOR 1 MEZZANINE WAREHOUSE B B S-2 100' 100' 100' COMMON PATH OF TRAVEL (PER DIAGRAMS ON A005): 96' 94' 48' NOTES EXIT DOORS SERVING AN OCCUPANT LOAD OF 50 OR MORE SHALL SWING IN THE DIRECTION OF TRAVEL. EXISTING ACCESS TO PUBLIC WAY MAINTAINS MINIMUM REQUIRED BUILDING EXIT WIDTHS. ALL EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. HAND ACTIVATED DOOR OPENING HARDWARE SHALL BE CENTERED BETWEEN 30 AND 44 INCHES ABOVE THE FLOOR. ALL INTERIOR FINISHES SHALL COMPLY WITH CHAPTER 8 OF THE CBC AND HAVE A MINIMUM CLASS C FLAME SPREAD RATIG PER TABLE 8-B. ALL CHANGES TO THE WORK SHALL FIRST REQUIRE THE WRITTEN APPROVAL OF THE ARCHITECT PRIOR TO COMMENCING WORK. DIMENSIONS NOTED "CLEAR" ARE SHOWN TO FACE FINISH. IF DISCREPANCIES ARE ENCOUNTERED, THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY. INSTALLATION SHALL FOLLOW MANUFACTURER'S RECOMMENDATIONS AND PUBLISHED SPECIFICATIONS AND/OR TRADE STANDARDS IN ADDITION TO MEETING THE STANDARDS SET FOTH IN THE CONSTRUCTION DOCUMENTS. NO IMPACT TOOL SHALL BE USED FOR ANY PURPUSE ON AN UNREINFORCED MASONRY BUILDING. ANYONE WHO IS DOING BUSINESS IN THE CITY OF BURLINGAME MUST HAVE A CURRENT CITY OF BURLINGAME BUSINESS LICENSE. DUE TO THE EXTENSIVE NATURE OF THIS CONSTRUCTION PROJECT, THE CERTIFICATE OF OCCUPANCY WILL BE RESCINDED ONCE CONSTRUCTION BEGINS. A NEW COO WILL BE ISSUED AFTER THE PROJECT HAS BEEN FINAL. NO OCCUPANCY OF THE BUILDING IS TO OCCUR UNTIL A NEW COO HAS BEEN ISSUED. THE DEMOLITION PERMIT WILL OT BE ISSUED UNTIL A BUILDING PERMIT IS ISSUED FOR THE PROJECT. A LEVEL LANDING MUST BE PROVIDED ON EACH SIDE OF THE DOOR AT ALL REQUIRED ENTRANCES AND EXITS. ALL LEVEL LANDINGS SHOULD COMPLY WITH 11B-302, 11B-304.2, AND 11B-305.2 OF THE 2019 CBC. SYMBOLS SCALE: 1/8" = 1'-0"2N SITE PLAN A401 KITCHEN & RESTROOM INTERIOR ELEVATIONSA004 ADA DIAGRAMS A005 AREA TAKE OFF AND EGRESS DIAGRAMS A030 EXISTING FLOOR AND ROOF PLANS A040 EXISTING EXTERIOR ELEVATIONS A050 DEMOLITION PLANS A100 REFERENCE FLOOR PLANS A101 FLOOR PLANS A102 ROOF PLAN A130 WAREHOUSE FLOOR AND ROOF PLANS A131 VEHICLE MANEUVER DIAGRAM A200 EXTERIOR ELEVATIONS A201 COLORED ELEVATIONS & MATERIAL BOARD A202 NEIGHBORHOOD PHOTOGRAPHS WEEKDAYS: 8:00 A.M. - 7:00 P.M. SATURDAYS: 9:00 A.M. - 6:00 P.M. SUNDAYS AND HOLIDAYS: NO WORK ALLOWED (SEE CITY OF BURLINGAME MUNICIPAL CODE, SECTION 18.07.110 FOR DETAILS.) (SEE CITY OF BURLINGAME MUNICIPAL CODE, SECTION 13.04.100 FOR DETAILS.) CONSTRUCTION HOURS IN THE CITY PUBLIC RIGHT-OF-WAY ARE LIMITED TO WEEKDAYS AND NON-CITY HOLIDAYS BETWEEN 8:00 A.M. AND 5:00 P.M. NOTE: CONSTRUCTIO HOURS IN THE PUBLIC RIGHT OF WAY MUST NOW BE INCLUDED ON THE PLANS. CONSTRUCTION HOURS 1 1 1 1 4 3 2 6 2 4 3 5 5 1 6 STUCCO 1. BOARD FORMED CONCRETE EXISTING (RESTORE IF REQUIRED, AND PAINT) 2. CARBONIZED WOOD PANEL DELTA WOOD 3. STEEL STOREFRONT (POWDER COATED OIL RUBBED BRONZE) JADA WINDOWS OR SIMILAR 4. TEMPERED REFLECTIVE GLASS 5. CMU BLOCK EXISTING, PAINT 6. SMOOTH TROWELED STUCCO 'SANTA BARBARA MISSION FINISH' INTEGRAL COLOR WHITE, LA HABRA STUCCO PROJECT: DATE: SCALE: STANDARD® LLP 4411 SANTA MONICA BLVD LOS ANGELES, CA 90029 INFO@STANDARDARCHITECTURE.COM TEL: 323 662 1000 ARCHITECT: PROJECT: AS NOTED ©2020 ALL RIGHTS RESERVED A201 220 California Dr Burlingame, CA 94010 CALIFORNIA DRIVE 12.14.20 PLAN CHECK SUBMITTAL 02.10.21 PLANNING CORRECTIONS∆1 2011 COLORED ELEVATIONS & MATERIAL BOARD 02/10/2021 SCALE: 1/4" = 1'-0"1(N) EXT FRONT ELEV_W SCALE: 1/4" = 1'-0"2(N) EXT REAR ELEV_E SCALE: 3/16" = 1'-0"3(N) EXT ELEV_N N.T.S.4MATERIAL BOARD 1 FIN FLR 0' -0" MEZZANINE 9' -4" 13' - 0" T.O. (N) STOREFRONT (E) OPENING 17'-8" T.O. CONC. PARAPET (N) STEEL, WOOD AND GLASS STOREFRONT (E) CONCRETE WALLS TO REMAIN, PAINT WOOD INFILL (N) SIGN (UNDER SEPARATE PERMIT) (N) EXTERIOR WALL SCONCE, O LUCE-FRESNEL-1148-L 100 CONC-01 1 FIN FLR 0' -0" 8 7 6 5 4 3 2 MEZZANINE 9' -4" 19 (E) MURAL 53' X 14' 21' - 1 5/8 (N) PARAPET 20 ' 6 1/2" TOP OF (N) PITCHED ROOF (N) RAISED PARAPET ROOF 17'-8" T.O. CONC. PARAPET 16'-8" T.O. BLOCK PARAPET (E) CONCRETE BLOCK WALL (E) BOARD FORMED CONCRETE WALL, PAINT 5.26.5 STUCCO-01 CONC-01BLOCK-01 A5001 Sim 1 FIN FLR 0' -0" MEZZANINE 9' -4"13 1/2"RELOCATED GAS METER NICHE 109 16'-8" T.O. BLOCK PARAPET 11' - 10 1/2" T.O. CLERESTORY (E) CONCRETE BLOCK WALL 6' - 10 1/2" T.O. (N) GATE 13' - 0"8' - 0"STUCCO (N) EXTERIOR WALL SCONCE, KALEIDOSCOPE VAPERTITE SERIES RLW26HFLAGC-4 (N) SECURITY LIGHT WPLED26Y (N) ROLL-UP GATE 110 BLOCK-01 PROJECT: DATE: SCALE: STANDARD® LLP 4411 SANTA MONICA BLVD LOS ANGELES, CA 90029 INFO@STANDARDARCHITECTURE.COM TEL: 323 662 1000 ARCHITECT: PROJECT: AS NOTED ©2020 ALL RIGHTS RESERVED A200 220 California Dr Burlingame, CA 94010 CALIFORNIA DRIVE 12.14.20 PLAN CHECK SUBMITTAL 02.10.21 PLANNING CORRECTIONS∆1 2011 EXTERIOR ELEVATIONS 02/10/2021 SCALE: 1/4" = 1'-0"1(N) EXT FRONT ELEV_W SCALE: 3/16" = 1'-0"3(N) EXT NORTH ELEVATION SCALE: 1/4" = 1'-0"2(N) EXT REAR ELEV_E 220 1 FIN FLR 0' -0" MEZZANINE 9' -4" 220 1 FIN FLR 0' -0" MEZZANINE 9' -4" 219 13 1/2"16'-8" T.O. BLOCK PARAPET (E) CONCRETE BLOCK WALL (E) SLIDING GATE (E) GAS METER 1 FIN FLR 0' -0" 8 7 6 5 4 3 2 MEZZANINE 9' -4" 19 (E) MURAL 53' X 14' 17'-8" T.O. CONC. PARAPET 16'-8" T.O. BLOCK PARAPET (E) CONCRETE BLOCK WALL (E) BOARD FORMED CONCRETE WALL 220 2 2 0 220 17'-8" T.O. CONC. PARAPET PAINTED RED STUCCO (E) STOREFRONT (E) STONE PROJECT: DATE: SCALE: STANDARD® LLP 4411 SANTA MONICA BLVD LOS ANGELES, CA 90029 INFO@STANDARDARCHITECTURE.COM TEL: 323 662 1000 ARCHITECT: PROJECT: AS NOTED ©2020 ALL RIGHTS RESERVED A040 220 California Dr Burlingame, CA 94010 CALIFORNIA DRIVE 12.14.20 PLAN CHECK SUBMITTAL 02.10.21 PLANNING CORRECTIONS∆1 2011 EXISTING EXTERIOR ELEVATIONS 02/10/2021 SCALE: 1/4" = 1'-0"3(E) EXT ELEV_ENTRY W SCALE: 1/4" = 1'-0"4(E) EXT ELEV_ENTRY S SCALE: 1/4" = 1'-0"2(E) EXT ELEV_ENTRY N SCALE: 1/4" = 1'-0"5(E) EXT REAR ELEV_E SCALE: 3/16" = 1'-0"6(E) EXT NORTH ELEVATION SCALE: 1/4" = 1'-0"1(E) EXT FRONT ELEV_W