Loading...
HomeMy WebLinkAboutReso - PC - 2021-09.13-8C\ DocuSign Envelope ID: 7144276C-216E-4AF9-ACA5-1A01E30AB5DE RECORDING REQUESTED BY: Planning Department City of Burlingame WHEN RECORDED MAIL TO: COMMUNITY DEVELOPMENT DEPARTMENT CITY OF BURLINGAME 501 PRIMROSE ROAD BURLINGAME, CA 94010 2021-166682 1:31 pm 12/06/21 R1 Fee: NO FEE Count of Pages 4 Rocorded in Official Records County of San Mateo Mark Church I illll I I lllli�i�lm11i11�11fim11 11�ii'i1�,��,��11111 11111111 •$R0003183038$• Resolution No. 2021-09.13.21-Sc 1114 EASTMOOR ROAD 025-242-130 TITLE OF DOCUMENT I hereby oertify this to be a full, true and correct oopy of the document it purports to be, the original of which is on file in my office. Date: Kevin Gardiner, AICP, Community Development Director 1. (E) PROPERTY LINE2. (E) FENCE TO REMAIN3. (E) OUTDOOR PARKING SPACE TO REMAIN4. (E) ELECTRIC METER TO REMAIN5. (E) NATURAL GAS METER TO BE RELOCATED6. (E) EXTERIOR WALL TO REMAIN. (N) WALLS TO BE BUILT ABOVE (E) FRAMING TO MATCH PROPOSED ROOF HEIGHT. ADD INSULATION AND GYP. BD. AT (E) EXTERIOR WALLS. SEE WALL ASSEMBILIES 1.1 @ A6.1 AND SEE SECTIONS @ A5.37. (E) EXTERIOR WALLS TO BE DEMOLISHED8. (E) ROOF TO BE DEMOLISHED9. (E) OUTDOOR CONCRETE PAVING TO BE MODIFIED10. (N) EXTENSION OF EXISTING WALLS11. (N) EXTENSION OF EXISTING CONCRETE FOUNDATION12. (N) ROOF WITH GUTTER SYSTEM13. (N) SINGLE-HUNG WINDOW, SEE WINDOW SCHEDULE @A8.1 AND WINDOW DETAILS @A8.214. (N) SLIDING WINDOW, SEE WINDOW SCHEDULE @A8.1 AND WINDOW DETAILS @A8.215. (N) ENTRY DOOR, SEE DOOR SCHEDULE @A8.1 AND DOOR DETAILS @A8.216. (N) FURNACE INSTALL AT ATTIC, TBD17. (N) TANKLESS WATER HEATER WITH 0.82 OR HIGHER ENERGY FACTOR WITH ENERGY CODE COMPLIANCE AND INSTALL AT ATTIC, TBD18. (N) WASHER & DRYER19. (N) WATER CLOSET20. (N) BATHROOM VANITY AND SINK, WIDTH SIZE OF 25" MAX. VIF. 21. (N) SHOWER, SIZE 3' X 5'. VIF.22. (N) BATHTUB, SIZE 3' X 5'. VIF. 23. (N) SKYLIGHT AT ROOF, SEE SIZE AT A8.1.24. (E) TREE.25. (N) DOWN SPOUT.26. (E) CLEANOUT.27. (N) A GAS FIREPLACE. COMPLIY WITH 2019 CEC.28. (E) A BACKFLOW PREVENTION DIVIDE / DOUBLE CHECK VALUE TO BE RELOACTED.29. (N) KITCHEN WALL MOUNT POT FILLER.30. (E) SEWER LATERAL CONNECTION; REMOVE / REPLACE SEWER LATERAL, SIDEWALK, CURB, AND GUTTER PER PUBLIC WORKS INSPECTOR IF DEEMED NECESSARY.31. (E) WATER METER, AND WATER LINE TO CONNECT THE WATER MAIN; INSTALL FIRE LINE AND REPLACE SIDEWALK, CURB, AND GUTTER PER FIRE DEPARTMENT INSPECTOR IF DEEMED NECESSARY.1NOTED:1. (N) EXTERIOR DOORS AND WINDOWS ARE MEASUREED FROM EXTERIOR FACE OF STUD TO THE CENTER. VIF.2. INT. DIMENSIONS ARE MEASURED FROM FINISH TO FINISH (INCLUDE 5/8" GWB AND 1" TILE AT BATHROOOM; 5/8" GWB AT BEDROOM). SEE ENLARGED PLAN A4.3JAMES HARDIE LAP SIDING BRICKSTUCCOCOMPOSITION SHINGLE ROOFINGWOOD SHUTTERSGLASSWOODSTUCCOPRINTEDDESIGNER:SHAN (SANBY) YUC: 1 (415) 335 - 0705E: syu133design@gmail.comU:DESIGNTWO EMBARCADERO CENTER, 8TH FLOORSAN FRANCISCO, CA 94111CONSULTANTSTAMPISSUE DATESHEET SCALE: PROJECT #:SHEET SIZE: PROJECT INFORMATION24" X 36" 8/25/2021 2:18:55 PM1/4" = 1'-0"A5.0PROPOSED 3DRENDERING1114 EASTMOOR ROAD, BURLINGAME, CA 94010LOURIDAS' RESIDENCEISSUE FOR PLAN CHECK 01/ 22/ 2021Project NumberNEW BEDROOMS AND BATHROOMS EXPANSION13D RENDERING VIEW 01KEY NOTESMATERIAL COLOR SAMPLES23D RENDERING VIEW 0243D RENDERING VIEW 0433D RENDERING VIEW 0311REVISION 1 08/12/20211 JAMES HARDIE LAP SIDING BRICKSTUCCOCOMPOSITION SHINGLE ROOFINGWOOD SHUTTERSGLASSWOODSTUCCO1. (E) PROPERTY LINE2. (E) FENCE TO REMAIN3. (E) OUTDOOR PARKING SPACE TO REMAIN4. (E) ELECTRIC METER TO REMAIN5. (E) NATURAL GAS METER TO BE RELOCATED6. (E) EXTERIOR WALL TO REMAIN. (N) WALLS TO BE BUILT ABOVE (E) FRAMING TO MATCH PROPOSED ROOF HEIGHT. ADD INSULATION AND GYP. BD. AT (E) EXTERIOR WALLS. SEE WALL ASSEMBILIES 1.1 @ A6.1 AND SEE SECTIONS @ A5.37. (E) EXTERIOR WALLS TO BE DEMOLISHED8. (E) ROOF TO BE DEMOLISHED9. (E) OUTDOOR CONCRETE PAVING TO BE MODIFIED10. (N) EXTENSION OF EXISTING WALLS11. (N) EXTENSION OF EXISTING CONCRETE FOUNDATION12. (N) ROOF WITH GUTTER SYSTEM13. (N) SINGLE-HUNG WINDOW, SEE WINDOW SCHEDULE @A8.1 AND WINDOW DETAILS @A8.214. (N) SLIDING WINDOW, SEE WINDOW SCHEDULE @A8.1 AND WINDOW DETAILS @A8.215. (N) ENTRY DOOR, SEE DOOR SCHEDULE @A8.1 AND DOOR DETAILS @A8.216. (N) FURNACE INSTALL AT ATTIC, TBD17. (N) TANKLESS WATER HEATER WITH 0.82 OR HIGHER ENERGY FACTOR WITH ENERGY CODE COMPLIANCE AND INSTALL AT ATTIC, TBD18. (N) WASHER & DRYER19. (N) WATER CLOSET20. (N) BATHROOM VANITY AND SINK, WIDTH SIZE OF 25" MAX. VIF. 21. (N) SHOWER, SIZE 3' X 5'. VIF.22. (N) BATHTUB, SIZE 3' X 5'. VIF. 23. (N) SKYLIGHT AT ROOF, SEE SIZE AT A8.1.24. (E) TREE.25. (N) DOWN SPOUT.26. (E) CLEANOUT.27. (N) A GAS FIREPLACE. COMPLIY WITH 2019 CEC.28. (E) A BACKFLOW PREVENTION DIVIDE / DOUBLE CHECK VALUE TO BE RELOACTED.29. (N) KITCHEN WALL MOUNT POT FILLER.30. (E) SEWER LATERAL CONNECTION; REMOVE / REPLACE SEWER LATERAL, SIDEWALK, CURB, AND GUTTER PER PUBLIC WORKS INSPECTOR IF DEEMED NECESSARY.31. (E) WATER METER, AND WATER LINE TO CONNECT THE WATER MAIN; INSTALL FIRE LINE AND REPLACE SIDEWALK, CURB, AND GUTTER PER FIRE DEPARTMENT INSPECTOR IF DEEMED NECESSARY.1NOTED:1. (N) EXTERIOR DOORS AND WINDOWS ARE MEASUREED FROM EXTERIOR FACE OF STUD TO THE CENTER. VIF.2. INT. DIMENSIONS ARE MEASURED FROM FINISH TO FINISH (INCLUDE 5/8" GWB AND 1" TILE AT BATHROOOM; 5/8" GWB AT BEDROOM). SEE ENLARGED PLAN A4.3LEVEL 12' -6"PROPERTY LINEPROPERTY LINETOP PLATE21' -0"LEVEL 212' -6"TOP OF RIDGE25' -6"(N)24"X54"(N)36"X54"(N)24"X54"(E)48"X60"(E) 16"X60"(N) 36"X54"(N)40"X20"3' - 0"(N) 36"X54"3' - 0"(N) 42" X 72"1' - 0"PLATE LEVEL 111' -6"4' - 6"9' - 0"SIDE SETBACK5' - 0"4 5 .0 0 °12' - 0"D.H.E. (97.34'+98.06') /2= 97.7'T.O.C. (96.63'+95.66') /2= 96.15'26' - 6".23' - 0"D.H.E. (96.26'+97.59') /2= 96.9'T.O.C. (96.63'+95.66') /2= 96.15'E.L. 98.65'(E) GRADEE.L. 121.65'E.L. 117.15'E.L. 108.65'E.L. 107.65'(N) 42" X 72"MAX. E.L. 126.15'4' - 6"8' - 6"1' - 0"ABOVE GRADE.29".7' - 6"SETBACK REQ.8' - 0" MIN.TYP. SIMULATED TRUE DIVIDED LIGHTTYP. WOOD FRAME WINDOW ANDERSON 400 SERIES WITH HARDIE TRIMTYP. WOOD SHUTTERSTYP. WOOD BRACKETS / CORBELSLEVEL 12' -6"PROPERTY LINEPROPERTY LINETOP PLATE21' -0"LEVEL 212' -6"TOP OF RIDGE25' -6"(N) 36"X54"(E)36"X54"(E)36"X54"(E)36"X54"(N) 48"X90"WOOD DOOR WITH SIDE WINDOW(N) WOOD RAILING& WOOD COLUMNS26' - 6".PLATE LEVEL 111' -6"D.H.E. (97.34'+98.06') /2= 97.7'T.O.C. (96.63'+95.66') /2= 96.15'4' - 6"9' - 0"23' - 0"D.H.E. (96.26'+97.59') /2= 96.9'T.O.C. (96.63'+95.66') /2= 96.15'E.L. 98.65'E.L. 121.65'E.L. 117.15'E.L. 108.65'E.L. 107.65'3' - 0"3' - 0"1' - 0"(N) 36"X54"(N) 36"X54"8' - 6"1' - 0"MAX. E.L. 126.15'4' - 6"(N)24"X48"5' - 0"ABOVE GRADE29".TYP. SIMULATED TRUE DIVIDED LIGHTTYP. WOOD FRAME WINDOW ANDERSON 400 SERIES WITH HARDIE TRIMTYP. WOOD SHUTTERSTYP. WOOD BRACKETS / CORBELSTYP. WOOD BRACKETS / CORBELS(N)108"X96"WOOD BARN DOORLEVEL 12' -6"PROPERTY LINEPROPERTY LINETOP PLATE21' -0"LEVEL 212' -6"TOP OF RIDGE25' -6"(N)36"X54"(N)20"X54"(N)108"X96"WOOD BARN DOOR(N) 40"X20"PLATE LEVEL 111' -6"D.H.E. (96.26'+97.59') /2= 96.9'T.O.C. (96.63'+95.66') /2= 96.15'26' - 6".23' - 0"9' - 0"4' - 6"D.H.E. (97.34'+98.06') /2= 97.7'T.O.C. (96.63'+95.66') /2= 96.15'E.L. 98.65'E.L. 121.65'E.L. 117.15'E.L. 108.65'E.L. 107.65'3' - 0"(N)20"X54"MAX. E.L. 126.15'8' - 6"1' - 0"4' - 6"12' - 0"45.00°7' - 6"SETBACK REQ.8' - 0" MIN.TYP. SIMULATED TRUE DIVIDED LIGHTTYP. WOOD FRAME WINDOW ANDERSON 400 SERIES WITH HARDIE TRIMTYP. WOOD SHUTTERSTYP. WOOD BRACKETS / CORBELSTYP. WOOD BRACKETS / CORBELSPRINTEDDESIGNER:SHAN (SANBY) YUC: 1 (415) 335 - 0705E: syu133design@gmail.comU:DESIGNTWO EMBARCADERO CENTER, 8TH FLOORSAN FRANCISCO, CA 94111CONSULTANTSTAMPISSUEDATESHEET SCALE: PROJECT #:SHEET SIZE: PROJECT INFORMATION24" X 36" 8/25/2021 2:32:47 PMAs indicatedA5.1PROPOSEDELEVATIONS1114 EASTMOOR ROAD, BURLINGAME, CA 94010LOURIDAS' RESIDENCEISSUE FOR PLAN CHECK 01/ 22/ 2021Project NumberNEW BEDROOMS AND BATHROOMS EXPANSIONMATERIAL COLOR SAMPLESKEY NOTES3/16" = 1'-0"1(N) EAST ELEVATION A3/16" = 1'-0"2(N) EAST ELEVATION B3/16" = 1'-0"3(N) EAST ELEVATION C11REVISION 1 08/12/20211 LEVEL 12' -6"PROPERTY LINEPROPERTY LINETOP PLATE21' -0"LEVEL 212' -6"TOP OF RIDGE25' -6"(N)36"X54"(N)24"X36"(E)18"X60"(N)36"X54"(N)36"X54"4' - 0"(N) 20"X20" (N) 20"X20"PLATE LEVEL 111' -6"23' - 0"9' - 0"4' - 6"E.L. 98.65'E.L. 121.65'E.L. 117.15'E.L. 108.65'E.L. 107.65'1' - 0"(N)24"X36"(N)24"X36"(N)18"X60"3' - 0"2' - 5"8' - 6"MAX. E.L. 126.15'4' - 6"TYP. SIMULATED TRUE DIVIDED LIGHTTYP. WOOD FRAME WINDOW ANDERSON 400 SERIES WITH HARDIE TRIMLEVEL 12' -6"TOP PLATE21' -0"LEVEL 212' -6"TOP OF RIDGE25' -6"(N)48"X30"(N)36"X54"(N)36"X60"(E)48"X24"5' - 0"(N)120"X90"(N)24"X36"(N)36"X54"(N)36"X54"(N)36"X54"(E)48"X24"(N)36"X80"(N)36"X60"3' - 0"(N)36"X60"12' - 0"PLATE LEVEL 111' -6"23' - 0"9' - 0"E.L. 98.65'E.L. 121.65'E.L. 117.15'E.L. 108.65'E.L. 107.65'1' - 0"(N)36"X54"8' - 6"4' - 6"MAX. E.L. 126.15'4' - 6"ABOVE GRADE29".D.H.E. (97.34'+98.06') /2= 97.7'T.O.C. (96.63'+95.66') /2= 96.15'PROPERTY LINESIDE SETBACK5' - 0"12' - 0"7' - 6"45.00°1' - 0"SETBACK REQ.8' - 0" MIN.TYP. SIMULATED TRUE DIVIDED LIGHTTYP. WOOD FRAME WINDOW ANDERSON 400 SERIES WITH HARDIE TRIMLEVEL 12' -6"PROPERTY LINEPROPERTY LINETOP PLATE21' -0"LEVEL 212' -6"TOP OF RIDGE25' -6"(N)36"X54"(N)48"X30"(N)36"X54"(E)48"X24"(N)36"X60"(N)120"X90"(E)48"X24"(N)36"X54"(N)36"X54"5' - 0"(N) WOOD FRAME WINDOWS(N)36"X60"(N)36"X60"(N)36"X60"12' - 0"2' - 0"10' - 0"PLATE LEVEL 111' -6"23' - 0"9' - 0"4' - 6"E.L. 98.65'E.L. 121.65'E.L. 117.15'E.L. 108.65'E.L. 107.65'1' - 0"(N)36"X54"3' - 0"8' - 6"4' - 6"MAX. E.L. 126.15'ABOVE GRADE29".TYP. SIMULATED TRUE DIVIDED LIGHTTYP. WOOD FRAME WINDOW ANDERSON 400 SERIES WITH HARDIE TRIM1. (E) PROPERTY LINE2. (E) FENCE TO REMAIN3. (E) OUTDOOR PARKING SPACE TO REMAIN4. (E) ELECTRIC METER TO REMAIN5. (E) NATURAL GAS METER TO BE RELOCATED6. (E) EXTERIOR WALL TO REMAIN. (N) WALLS TO BE BUILT ABOVE (E) FRAMING TO MATCH PROPOSED ROOF HEIGHT. ADD INSULATION AND GYP. BD. AT (E) EXTERIOR WALLS. SEE WALL ASSEMBILIES 1.1 @ A6.1 AND SEE SECTIONS @ A5.37. (E) EXTERIOR WALLS TO BE DEMOLISHED8. (E) ROOF TO BE DEMOLISHED9. (E) OUTDOOR CONCRETE PAVING TO BE MODIFIED10. (N) EXTENSION OF EXISTING WALLS11. (N) EXTENSION OF EXISTING CONCRETE FOUNDATION12. (N) ROOF WITH GUTTER SYSTEM13. (N) SINGLE-HUNG WINDOW, SEE WINDOW SCHEDULE @A8.1 AND WINDOW DETAILS @A8.214. (N) SLIDING WINDOW, SEE WINDOW SCHEDULE @A8.1 AND WINDOW DETAILS @A8.215. (N) ENTRY DOOR, SEE DOOR SCHEDULE @A8.1 AND DOOR DETAILS @A8.216. (N) FURNACE INSTALL AT ATTIC, TBD17. (N) TANKLESS WATER HEATER WITH 0.82 OR HIGHER ENERGY FACTOR WITH ENERGY CODE COMPLIANCE AND INSTALL AT ATTIC, TBD18. (N) WASHER & DRYER19. (N) WATER CLOSET20. (N) BATHROOM VANITY AND SINK, WIDTH SIZE OF 25" MAX. VIF. 21. (N) SHOWER, SIZE 3' X 5'. VIF.22. (N) BATHTUB, SIZE 3' X 5'. VIF. 23. (N) SKYLIGHT AT ROOF, SEE SIZE AT A8.1.24. (E) TREE.25. (N) DOWN SPOUT.26. (E) CLEANOUT.27. (N) A GAS FIREPLACE. COMPLIY WITH 2019 CEC.28. (E) A BACKFLOW PREVENTION DIVIDE / DOUBLE CHECK VALUE TO BE RELOACTED.29. (N) KITCHEN WALL MOUNT POT FILLER.30. (E) SEWER LATERAL CONNECTION; REMOVE / REPLACE SEWER LATERAL, SIDEWALK, CURB, AND GUTTER PER PUBLIC WORKS INSPECTOR IF DEEMED NECESSARY.31. (E) WATER METER, AND WATER LINE TO CONNECT THE WATER MAIN; INSTALL FIRE LINE AND REPLACE SIDEWALK, CURB, AND GUTTER PER FIRE DEPARTMENT INSPECTOR IF DEEMED NECESSARY.1NOTED:1. (N) EXTERIOR DOORS AND WINDOWS ARE MEASUREED FROM EXTERIOR FACE OF STUD TO THE CENTER. VIF.2. INT. DIMENSIONS ARE MEASURED FROM FINISH TO FINISH (INCLUDE 5/8" GWB AND 1" TILE AT BATHROOOM; 5/8" GWB AT BEDROOM). SEE ENLARGED PLAN A4.3JAMES HARDIE LAP SIDING BRICKSTUCCOCOMPOSITION SHINGLE ROOFINGWOOD SHUTTERSGLASSWOODSTUCCOPRINTEDDESIGNER:SHAN (SANBY) YUC: 1 (415) 335 - 0705E: syu133design@gmail.comU:DESIGNTWO EMBARCADERO CENTER, 8TH FLOORSAN FRANCISCO, CA 94111CONSULTANTSTAMPISSUE DATESHEET SCALE: PROJECT #:SHEET SIZE: PROJECT INFORMATION24" X 36" 8/25/2021 2:19:07 PMAs indicatedA5.2PROPOSEDELEVATIONS1114 EASTMOOR ROAD, BURLINGAME, CA 94010LOURIDAS' RESIDENCEISSUE FOR PLAN CHECK 01/ 22/ 2021Project NumberNEW BEDROOMS AND BATHROOMS EXPANSION3/16" = 1'-0"1(N) SOUTH ELEVATION3/16" = 1'-0"2(N) WEST ELEVATION3/16" = 1'-0"3(N) NORTH ELEVATIONKEY NOTESMATERIAL COLOR SAMPLES11REVISION 1 08/12/20211 PROPERTY LINE(N)108"X96"BARN DOOR(E) SIDE SETBACK3' - 0"D.H.E. (96.26'+97.59') /2= 96.9'T.O.C. (96.63'+95.66') /2= 96.15'T.O.RIDGE 108.9'12' - 0"PROPERTY LINE12' - 0"1. (E) PROPERTY LINE2. (E) FENCE TO REMAIN3. (E) OUTDOOR PARKING SPACE TO REMAIN4. (E) ELECTRIC METER TO REMAIN5. (E) NATURAL GAS METER TO BE RELOCATED6. (E) EXTERIOR WALL TO REMAIN. (N) WALLS TO BE BUILT ABOVE (E) FRAMING TO MATCH PROPOSED ROOF HEIGHT. ADD INSULATION AND GYP. BD. AT (E) EXTERIOR WALLS. SEE WALL ASSEMBILIES 1.1 @ A6.1 AND SEE SECTIONS @ A5.37. (E) EXTERIOR WALLS TO BE DEMOLISHED8. (E) ROOF TO BE DEMOLISHED9. (E) OUTDOOR CONCRETE PAVING TO BE MODIFIED10. (N) EXTENSION OF EXISTING WALLS11. (N) EXTENSION OF EXISTING CONCRETE FOUNDATION12. (N) ROOF WITH GUTTER SYSTEM13. (N) SINGLE-HUNG WINDOW, SEE WINDOW SCHEDULE @A8.1 AND WINDOW DETAILS @A8.214. (N) SLIDING WINDOW, SEE WINDOW SCHEDULE @A8.1 AND WINDOW DETAILS @A8.215. (N) ENTRY DOOR, SEE DOOR SCHEDULE @A8.1 AND DOOR DETAILS @A8.216. (N) FURNACE INSTALL AT ATTIC, TBD17. (N) TANKLESS WATER HEATER WITH 0.82 OR HIGHER ENERGY FACTOR WITH ENERGY CODE COMPLIANCE AND INSTALL AT ATTIC, TBD18. (N) WASHER & DRYER19. (N) WATER CLOSET20. (N) BATHROOM VANITY AND SINK, WIDTH SIZE OF 25" MAX. VIF. 21. (N) SHOWER, SIZE 3' X 5'. VIF.22. (N) BATHTUB, SIZE 3' X 5'. VIF. 23. (N) SKYLIGHT AT ROOF, SEE SIZE AT A8.1.24. (E) TREE.25. (N) DOWN SPOUT.26. (E) CLEANOUT.27. (N) A GAS FIREPLACE. COMPLIY WITH 2019 CEC.28. (E) A BACKFLOW PREVENTION DIVIDE / DOUBLE CHECK VALUE TO BE RELOACTED.29. (N) KITCHEN WALL MOUNT POT FILLER.30. (E) SEWER LATERAL CONNECTION; REMOVE / REPLACE SEWER LATERAL, SIDEWALK, CURB, AND GUTTER PER PUBLIC WORKS INSPECTOR IF DEEMED NECESSARY.31. (E) WATER METER, AND WATER LINE TO CONNECT THE WATER MAIN; INSTALL FIRE LINE AND REPLACE SIDEWALK, CURB, AND GUTTER PER FIRE DEPARTMENT INSPECTOR IF DEEMED NECESSARY.1NOTED:1. (N) EXTERIOR DOORS AND WINDOWS ARE MEASUREED FROM EXTERIOR FACE OF STUD TO THE CENTER. VIF.2. INT. DIMENSIONS ARE MEASURED FROM FINISH TO FINISH (INCLUDE 5/8" GWB AND 1" TILE AT BATHROOOM; 5/8" GWB AT BEDROOM). SEE ENLARGED PLAN A4.3JAMES HARDIE LAP SIDING BRICKSTUCCOCOMPOSITION SHINGLE ROOFINGWOOD SHUTTERSGLASSWOODSTUCCOPROPERTY LINE(E) SIDE SETBACK3' - 0"(N)24"X36"(N)36"X80"MILGARD TUSCANY VINYL WINDOWST.O.RIDGE 108.9'D.H.E. (96.26'+97.59') /2= 96.9'T.O.C. (96.63'+95.66') /2= 96.15'10' - 0"4' - 0"PROPERTY LINE(N)36"X80"12' - 0"7' - 0"9' - 0"PROPERTY LINE3' - 0"D.H.E. (96.26'+97.59') /2= 96.9'T.O.C. (96.63'+95.66') /2= 96.15'T.O.RIDGE 108.9'12' - 0"9' - 0"12' - 0"PROPERTY LINE(E) FRONT SETBACK21' - 6"9' - 0"PRINTEDDESIGNER:SHAN (SANBY) YUC: 1 (415) 335 - 0705E: syu133design@gmail.comU:DESIGNTWO EMBARCADERO CENTER, 8TH FLOORSAN FRANCISCO, CA 94111CONSULTANTSTAMPISSUE DATESHEET SCALE: PROJECT #:SHEET SIZE: PROJECT INFORMATION24" X 36" 8/25/2021 2:19:13 PMAs indicatedA5.4PROPOSEDELEVATIONS1114 EASTMOOR ROAD, BURLINGAME, CA 94010LOURIDAS' RESIDENCEISSUE FOR PLAN CHECK 01/ 22/ 2021Project NumberNEW BEDROOMS AND BATHROOMS EXPANSION3/16" = 1'-0"1(N) EAST ELEVATION C - GARAGE3/16" = 1'-0"4(N) NORTH ELEVATION - GARAGEKEY NOTESMATERIAL COLOR SAMPLES3/16" = 1'-0"3(N) WEST ELEVATION - GARAGE3/16" = 1'-0"2(N) SOUTH ELEVATOIN - GARAGE3/16" = 1'-0"5GARAGE SECTION A3/16" = 1'-0"6GARAGE SECTION B11REVISION 1 08/12/2021 LEVEL 12' -6"B.O.CEILING10' -4"GRADE0' -0"PROPERTY LINEPROPERTY LINELEVEL 12' -6"B.O.CEILING10' -4"GRADE0' -0"PROPERTY LINEPROPERTY LINELEVEL 12' -6"B.O.CEILING10' -4"GRADE0' -0"PROPERTY LINEPROPERTY LINEPRINTEDDESIGNER:SHAN (SANBY) YUC: 1 (415) 335 - 0705E: syu133design@gmail.comU:DESIGNTWO EMBARCADERO CENTER, 8TH FLOORSAN FRANCISCO, CA 94111CONSULTANTSTAMPISSUEDATESHEET SCALE: PROJECT #:SHEET SIZE: PROJECT INFORMATION24" X 36" 10/21/2020 5:53:14 PM3/16" = 1'-0"A3.1EXISTINGELEVATIONS1114 EASTMOOR ROAD, BURLINGAME, CA 94010LOURIDAS' RESIDENCE1ST ISSUE 10 / XX / 2020Project NumberNEW BEDROOMS AND BATHROOMS EXPANSION3/16" = 1'-0"1(E) EAST ELEVATION A3/16" = 1'-0"2(E) EAST ELEVATION B3/16" = 1'-0"3(E) EAST ELEVATION C LEVEL 12' -6"B.O.CEILING10' -4"GRADE0' -0"PROPERTY LINEPROPERTY LINE65' - 0"21' - 4"21' - 6"107' - 10"LEVEL 12' -6"B.O.CEILING10' -4"GRADE0' -0"LEVEL 12' -6"B.O.CEILING10' -4"GRADE0' -0"PROPERTY LINEPROPERTY LINE24' - 8"54' - 1"21' - 6"100' - 3"PRINTEDDESIGNER:SHAN (SANBY) YUC: 1 (415) 335 - 0705E: syu133design@gmail.comU:DESIGNTWO EMBARCADERO CENTER, 8TH FLOORSAN FRANCISCO, CA 94111CONSULTANTSTAMPISSUEDATESHEET SCALE: PROJECT #:SHEET SIZE: PROJECT INFORMATION24" X 36" 10/21/2020 5:51:02 PM3/16" = 1'-0"A3.2EXISTINGELEVATIONS1114 EASTMOOR ROAD, BURLINGAME, CA 94010LOURIDAS' RESIDENCE1ST ISSUE 10 / XX / 2020Project NumberNEW BEDROOMS AND BATHROOMS EXPANSION3/16" = 1'-0"3(E) NORTH ELEVATION3/16" = 1'-0"2(E) WEST ELEVATION3/16" = 1'-0"1(E) SOUTH ELEVATION 1. (E) PROPERTY LINE2. (E) FENCE TO REMAIN3. (E) OUTDOOR PARKING SPACE TO REMAIN4. (E) ELECTRIC METER TO REMAIN5. (E) NATURAL GAS METER TO BE RELOCATED6. (E) EXTERIOR WALL TO REMAIN. (N) WALLS TO BE BUILT ABOVE (E) FRAMING TO MATCH PROPOSED ROOF HEIGHT. ADD INSULATION AND GYP. BD. AT (E) EXTERIOR WALLS. SEE WALL ASSEMBILIES 1.1 @ A6.1 AND SEE SECTIONS @ A5.37. (E) EXTERIOR WALLS TO BE DEMOLISHED8. (E) ROOF TO BE DEMOLISHED9. (E) OUTDOOR CONCRETE PAVING TO BE MODIFIED10. (N) EXTENSION OF EXISTING WALLS11. (N) EXTENSION OF EXISTING CONCRETE FOUNDATION12. (N) ROOF WITH GUTTER SYSTEM13. (N) SINGLE-HUNG WINDOW, SEE WINDOW SCHEDULE @A8.1 AND WINDOW DETAILS @A8.214. (N) SLIDING WINDOW, SEE WINDOW SCHEDULE @A8.1 AND WINDOW DETAILS @A8.215. (N) ENTRY DOOR, SEE DOOR SCHEDULE @A8.1 AND DOOR DETAILS @A8.216. (N) FURNACE INSTALL AT ATTIC, TBD17. (N) TANKLESS WATER HEATER WITH 0.82 OR HIGHER ENERGY FACTOR WITH ENERGY CODE COMPLIANCE AND INSTALL AT ATTIC, TBD18. (N) WASHER & DRYER19. (N) WATER CLOSET20. (N) BATHROOM VANITY AND SINK, WIDTH SIZE OF 25" MAX. VIF. 21. (N) SHOWER, SIZE 3' X 5'. VIF.22. (N) BATHTUB, SIZE 3' X 5'. VIF. 23. (N) SKYLIGHT AT ROOF, SEE SIZE AT A8.1.24. (E) TREE.25. (N) DOWN SPOUT.26. (E) CLEANOUT.27. (N) A GAS FIREPLACE. COMPLIY WITH 2019 CEC.28. (E) A BACKFLOW PREVENTION DIVIDE / DOUBLE CHECK VALUE TO BE RELOACTED.29. (N) KITCHEN WALL MOUNT POT FILLER.30. (E) SEWER LATERAL CONNECTION; REMOVE / REPLACE SEWER LATERAL, SIDEWALK, CURB, AND GUTTER PER PUBLIC WORKS INSPECTOR IF DEEMED NECESSARY.31. (E) WATER METER, AND WATER LINE TO CONNECT THE WATER MAIN; INSTALL FIRE LINE AND REPLACE SIDEWALK, CURB, AND GUTTER PER FIRE DEPARTMENT INSPECTOR IF DEEMED NECESSARY.1NOTED:1. (N) EXTERIOR DOORS AND WINDOWS ARE MEASUREED FROM EXTERIOR FACE OF STUD TO THE CENTER. VIF.2. INT. DIMENSIONS ARE MEASURED FROM FINISH TO FINISH (INCLUDE 5/8" GWB AND 1" TILE AT BATHROOOM; 5/8" GWB AT BEDROOM). SEE ENLARGED PLAN A4.3LEVEL 12' -6"TOP PLATE21' -0"LEVEL 212' -6"TOP OF RIDGE25' -6"PROPERTY LINE4 5 .0 0 °7' - 6"(E) SIDE SETBACK5' - 0"SETBACK REQ. 8' - 0" MIN.12' - 0"9' - 0"PLATE LEVEL 111' -6"E.L. 98.65'E.L. 121.65'E.L. 117.15'E.L. 108.65'E.L. 107.65'23' - 0"4' - 6"8' - 6"1' - 0"9' - 0"8' - 6"D.H.E. (97.34'+98.06') /2= 97.7'T.O.C. (96.63'+95.66') /2= 96.15'12' - 0"MAX. E.L. 126.15'LEVEL 12' -6"TOP PLATE21' -0"LEVEL 212' -6"TOP OF RIDGE25' -6"7' - 0"2' - 6"3' - 6"6' - 9"3' - 0"8' - 8"9' - 0"9' - 0"2' - 0"10' - 0"PLATE LEVEL 111' -6"E.L. 98.65'E.L. 121.65'E.L. 117.15'E.L. 108.65'E.L. 107.65'23' - 0"4' - 6"8' - 6"1' - 0"9' - 0"8' - 6"LEVEL 12' -6"TOP PLATE21' -0"LEVEL 212' -6"9' - 0"TOP OF RIDGE25' -6"2' - 0"10' - 0"PLATE LEVEL 111' -6"E.L. 98.65'E.L. 121.65'E.L. 117.15'E.L. 108.65'E.L. 107.65'23' - 0"4' - 6"8' - 6"1' - 0"9' - 0"1' - 6"6' - 0"1' - 6"8' - 6"LEVEL 12' -6"TOP PLATE21' -0"LEVEL 212' -6"TOP OF RIDGE25' -6"PROPERTY LINE4 5 .0 0 °(E) SIDE SETBACK5' - 0"SETBACK REQ.8' - 0" MIN.12' - 0"PLATE LEVEL 111' -6"E.L. 98.65'E.L. 121.65'E.L. 117.15'E.L. 108.65'E.L. 107.65'23' - 0"4' - 6"8' - 6"1' - 0"9' - 0"8' - 6"9' - 0"12' - 0"7' - 6"D.H.E. (97.34'+98.06') /2= 97.7'T.O.C. (96.63'+95.66') /2= 96.15'MAX. E.L. 126.15'LEVEL 12' -6"TOP PLATE21' -0"LEVEL 212' -6"TOP OF RIDGE25' -6"9' - 0"8' - 6"2' - 0"10' - 0"PLATE LEVEL 111' -6"E.L. 98.65'E.L. 121.65'E.L. 117.15'E.L. 108.65'E.L. 107.65'23' - 0"4' - 6"8' - 6"1' - 0"9' - 0"PRINTEDDESIGNER:SHAN (SANBY) YUC: 1 (415) 335 - 0705E: syu133design@gmail.comU:DESIGNTWO EMBARCADERO CENTER, 8TH FLOORSAN FRANCISCO, CA 94111CONSULTANTSTAMPISSUE DATESHEET SCALE: PROJECT #:SHEET SIZE: PROJECT INFORMATION24" X 36" 8/25/2021 2:19:09 PMAs indicatedA5.3PROPOSED SECTION1114 EASTMOOR ROAD, BURLINGAME, CA 94010LOURIDAS' RESIDENCEISSUE FOR PLAN CHECK 01/ 22/ 2021Project NumberNEW BEDROOMS AND BATHROOMS EXPANSIONKEY NOTES1/8" = 1'-0"4PROPOSED SECTION 041/8" = 1'-0"1PROPOSED SECTION 011/8" = 1'-0"2PROPOSED SECTION 021/8" = 1'-0"5PROPOSED SECTION 051/8" = 1'-0"3PROPOSED SECTION 0311REVISION 1 08/12/2021 A5.11A5.12A5.13A5.23A5.21A5.224A5.31A5.32A5.35A5.33A5.3PARCEL NUMBER: 025-242-120PARCEL NUMBER: 025-242-1403" / 1'-0"3" / 1'-0"3" / 1'-0"3" / 1'-0"3" / 1'-0"6" / 1'-0"6" / 1'-0"3" / 1'-0"3" / 1'-0"4" / 1'-0"4" / 1'-0"3" / 1'-0"A5.41A5.44A5.43A5.425A5.46A5.43" / 1'-0 "3" / 1'-0"1. (E) PROPERTY LINE2. (E) FENCE TO REMAIN3. (E) OUTDOOR PARKING SPACE TO REMAIN4. (E) ELECTRIC METER TO REMAIN5. (E) NATURAL GAS METER TO BE RELOCATED6. (E) EXTERIOR WALL TO REMAIN. (N) WALLS TO BE BUILT ABOVE (E) FRAMING TO MATCH PROPOSED ROOF HEIGHT. ADD INSULATION AND GYP. BD. AT (E) EXTERIOR WALLS. SEE WALL ASSEMBILIES 1.1 @ A6.1 AND SEE SECTIONS @ A5.37. (E) EXTERIOR WALLS TO BE DEMOLISHED8. (E) ROOF TO BE DEMOLISHED9. (E) OUTDOOR CONCRETE PAVING TO BE MODIFIED10. (N) EXTENSION OF EXISTING WALLS11. (N) EXTENSION OF EXISTING CONCRETE FOUNDATION12. (N) ROOF WITH GUTTER SYSTEM13. (N) SINGLE-HUNG WINDOW, SEE WINDOW SCHEDULE @A8.1 AND WINDOW DETAILS @A8.214. (N) SLIDING WINDOW, SEE WINDOW SCHEDULE @A8.1 AND WINDOW DETAILS @A8.215. (N) ENTRY DOOR, SEE DOOR SCHEDULE @A8.1 AND DOOR DETAILS @A8.216. (N) FURNACE INSTALL AT ATTIC, TBD17. (N) TANKLESS WATER HEATER WITH 0.82 OR HIGHER ENERGY FACTOR WITH ENERGY CODE COMPLIANCE AND INSTALL AT ATTIC, TBD18. (N) WASHER & DRYER19. (N) WATER CLOSET20. (N) BATHROOM VANITY AND SINK, WIDTH SIZE OF 25" MAX. VIF. 21. (N) SHOWER, SIZE 3' X 5'. VIF.22. (N) BATHTUB, SIZE 3' X 5'. VIF. 23. (N) SKYLIGHT AT ROOF, SEE SIZE AT A8.1.24. (E) TREE.25. (N) DOWN SPOUT.26. (E) CLEANOUT.27. (N) A GAS FIREPLACE. COMPLIY WITH 2019 CEC.28. (E) A BACKFLOW PREVENTION DIVIDE / DOUBLE CHECK VALUE TO BE RELOACTED.29. (N) KITCHEN WALL MOUNT POT FILLER.30. (E) SEWER LATERAL CONNECTION; REMOVE / REPLACE SEWER LATERAL, SIDEWALK, CURB, AND GUTTER PER PUBLIC WORKS INSPECTOR IF DEEMED NECESSARY.31. (E) WATER METER, AND WATER LINE TO CONNECT THE WATER MAIN; INSTALL FIRE LINE AND REPLACE SIDEWALK, CURB, AND GUTTER PER FIRE DEPARTMENT INSPECTOR IF DEEMED NECESSARY.1NOTED:1. (N) EXTERIOR DOORS AND WINDOWS ARE MEASUREED FROM EXTERIOR FACE OF STUD TO THE CENTER. VIF.2. INT. DIMENSIONS ARE MEASURED FROM FINISH TO FINISH (INCLUDE 5/8" GWB AND 1" TILE AT BATHROOOM; 5/8" GWB AT BEDROOM). SEE ENLARGED PLAN A4.31tWINDOW TAGDOOR TAG1REVISION CALLOUT TAG DWG. # SHT. # PROPERTY LINE CENTER LINE ALIGN ALIGN FACES A1011SIMROOM NAME / NUMBERSTRUCTURAL GRID LINEROOM NAME1.1KEY NOTEDRAWING / DETAIL REFERENCE1SECTION REFERENCE1ELEVATION REFERENCE1A1.1A1.1PARTITION TYPE, SEE SHT. A9.01 & A9.02A1.1REFERENCE TARGET1-0111(N) LIVING AREADEMOLITION WALLSDEMO (E) WALLS AND BUILD (N) WALLS(E) WALLS(N) GARAGE & WORKSHOP(N) INACCESSIBLE SPACE @ ROOFDEMOLITION EXTERIOR WALLSPRINTEDDESIGNER:SHAN (SANBY) YUC: 1 (415) 335 - 0705E: syu133design@gmail.comU:DESIGNTWO EMBARCADERO CENTER, 8TH FLOORSAN FRANCISCO, CA 94111CONSULTANTSTAMPISSUE DATESHEET SCALE: PROJECT #:SHEET SIZE: PROJECT INFORMATION24" X 36" 8/25/2021 2:18:48 PM1/4" = 1'-0"A4.5PROPOSEDENLARGED PLAN -ROOF1114 EASTMOOR ROAD, BURLINGAME, CA 94010LOURIDAS' RESIDENCEISSUE FOR PLAN CHECK 01/ 22/ 2021Project NumberNEW BEDROOMS AND BATHROOMS EXPANSION1/4" = 1'-0"1PROPOSED ENLARGED PLAN - ROOFKEY NOTESSYMBOL LEGEND11REVISION 1 08/12/2021