Loading...
HomeMy WebLinkAboutReso - PC - 2022.06.27 - 8ADocuSign Envelope lD: 7A4A3739-5554-4658-A1 CF-FEF67EA44D6D RECORDING REOUESTED BY Planning Department City of Burlingame COMMUNITY DEVELOPMENT DEPARTI\,1ENT CIry OF BURLINGAME 501 PRIMROSE ROAD BURLINGAME, CA 94010 2022-066364 3i37 pm 03/09/2022 R1 Feer NO FEE CounrofPages4 Pecord6d ih olticial Recor,s County ol San Mateo Marl Chrlch Assessor-Co unly Cierk-[iecoder 4 il il lt il illl ltll I llll llll ll. $R000128? 965$* Resolution No. 2022-06.27 -8A 620 TRENTON WAY APN 029-165-210 I hereby certify this to be a full, true and conect mpy of the document it purports to be, the original of wfiich is on file in my otfce JU 8, 2022 *"lw 6avli*r TITLE OF DOCUMENT CITY Date Kevin Gard ner AICP Community Development D ATEO.,'UHE b WHEN RECORDED fuIA L TO: BpFL!,ry-GF,uE RESOLUTION APPROVING CATEGORICAL EXEMPTION ANO DESIGN REVIEW RESOLVED, by the Planning Commission of the City of Burlingame that WHEREAS, a Categorical Exemption has been prepared and application has been made for Desiqn Review for a first and second storv ad diti on to an existino sinole-unit dwellino 620 T renton Wav, Zoned R-1 , Patricia and Griffin Tormev, oro pertv owners. APN: 029- 165-210 WHEREAS, said matters were heard by the Planning Commission of the City of Burlingame on June 27. 2O22, al which time it reviewed and considered the staff report and all other written materials and testimony presented at said hearing. NOW, THEREFORE, it is RESOLVED and DETERMINED by this Planning Commission that On the basrs of the lnitial Study and the documents submitted and reviewed, and comments received and addressed by this Commission, it is hereby found that there is no substantial evidence that the project set forth above will have a significant effect on the environment, and categorical exemption, per CEQA Section 15301(e)(2), which states that addrtions to existing structures are exempt from environmental review, provided the addition will not result in an increase of more than 10,000 SF in areas where all public services and facilities are available and the area in which the prolect is located is not environmentally sensitive, is hereby approved. 2 3 It is further directed th County of San Mateo. at a certified copy of this reso tion be recorded in the officia ords of the Chairpe n f, PFArr , Secretary of the Planning Commission of the City of Burlingame, do hereby certify that the foregoing resolution was introduced and adopted at a regular meeting of the Planning Commission held on the 27lh dav of June.2022 by the following vote: 520 TRETTON WAy - RESO 2022{t5-27{AAYES: CO AROTO, GAUL, HORAN, PFAFF, TSENOES: I{ONE ABSET{T: LOWENTHAI-SCHHID RECUSED: NONE ,n t-. l-, tary Said Design Review is approved subject to the conditions set forth in Exhibit "A" attached hereto. Findings for such Design Review are set forth in the staff report, minutes, and recording of said meeting. 1 EXHIBIT "A" Conditions of Approval for Categorical Exemption and Design Review 620 Trenton Way Effective July 7, 2022 Page'l 1 that the project shall be built as shown on the plans submitted to the Planning Division and date stamped June 21, 2022, sheets A0.0 through A5.1; 2 3 that any changes to building materials, exterior finishes, windows, architectural features, roof height or pitch, and amount or type of hardscape materials shall be subject to Planning Division or Planning Commission review (FYl or amendment to be determined by Planning staff); that any changes to the size or envelope of the first or second floors which would include adding or enlarging a dormer(s), shall require an amendment to this permit; that any recycling containers. debris boxes or dumpsters for the construction project shall be placed upon the private property if feasible, as determined by the Community Development Director, that prior to issuance of a building permit for construction of the project, the project construction plans shall be modified to include a cover sheet listing all conditions of approval adopted by the Planning Commission, or City Council on appeal, which shall remain a part of all sets of approved plans throughout the construction process. Compliance with all conditions of approval is required; the conditions of approval shall not be modified or changed without the approval of the Planning Commission, or City Council on appeal; that all air ducts, plumbing vents, and flues shall be combined, where possible, to a single termination and installed on the portions of the roof not visible from the street, and that these venting details shall be included and approved in the construction plans before a Building permit is issued; that the project shall comply with the Construction and Demolition Debris Recycling Ordinance which requires affected demolition, new construction and alteration projects to submit a Waste Reduction plan and meet recycling requirements; any partial or full demolition of a structure, interior or exterior, shall require a demolition permit; that the project shall meet all the requirements of the California Building and Uniform Fire Codes, in effecl at time of building permit submittal, as amended by the City of Burlingame; THE FOLLOWING CONDITIONS SHALL BE MET DURING THE BUILDING INSPECTION PROCESS PRIOR TO THE INSPECTIONS NOTED IN EACH CONDITION: that prior to scheduling the framing inspection the applicant shall provide a certification by the project architect or residential designer, or another architect or residential design professional, that demonstrates that the projecl falls at or below the maximum approved floor area ratio for the property; 4 6 7 8 I 10 that demolition for removal of the existing structures and any grading or earth moving on the site shall not occur until a building permit has been issued and such site work shall be required to comply with all the regulations of the Bay Area Air Quality Management District; EXHIBIT "A" Conditions of Approval for Categorical Exemption and Design Review 620 Trenton Way Effective July 7, 2022 Page 2 11 12. 13. that prior to scheduling the framing inspection the project architect or residentral designer, or another architect or residential design professional, shall provide an architectural certification that the architectural details shown in the approved design which should be evident at framing, such as window locations and bays, are built as shown on the approved plans; architectural certification documenting framing comp ance with approved design shall be submitted to the Building Division before the final framing inspection shall be scheduled: that prior to scheduling the roof deck inspectton, a licensed surveyor shall shoot the height of the roof ridge and provide certification of that height to the Building Division; and that prior to final inspection, Planning Division staff will inspect and note compliance of the architectural details (trim materials, window type, etc.) to verify that the project has been built according to the approved Planning and Building plans. DTA DreilingTeRonesArchitecture Inc. Tormey Residence at 620 Trenton Way Architecture I Infrastructure I Environments Massing Model 06/17/2022 T.O. Ridge EL ± 12'-2" T.O. Plate EL +8'-0" FF EL: 102.66' 0'-0" F.G. EL: 101.6' Finish Grade EL: 100.4' 12 4 0o E U I� (N) T.O. Ridge EL: ±22'-5" (N) 2nd FI. T.O. PlatE EL: / ±17'-6" / 0 0 I . o 00 / 20 s (N) 2nd FI. FF..EL: ±g'-6" T.O. Plate EL „ B.O. Bm. EL: +7'-4" I o a o � `00 FF EL: 102.66' 0'-01, F.G. EL: 101 e6' Avg. T.O.C. EL: 100. Existing Elevation: South 2 (N) Skylight F, 9 1 7191 16 MINE E110101 ME E11010 01010 (N) Skylight T 7typ- iiiiiiValm J_I❑_ ICJ 11111111 E. 11 T] �� i vy V \ i V, v ry u�'6' 0 0 I� 0 Al 2 19 14 21 4 9 6 typ. (N) Illuminated address number with (N) Wood entry door backplate, %" stroke x 4" high font rn--� Proposed Elevation: South 19 5 typ. T 19 1 I 116 12 �4 1 /4" = 1 '-0" (N) Photovoltaic panel, typ. 12 �4 1 /4'' = 1'-0" T.O.C. EL: 100.4' F. G. EL: 10 0. 1 ' .,, Exterior Finishes / Systems: • Painted (E) Exterior Cement Plaster at 1st Floor • Painted (E) Wood Siding at Garage • Stained (N) Cedar Shingle Siding at 2nd Floor • Painted (N) Wood Trims throughout • (N) Aluminum -clad Wood Windows throughout • (N) Brick -clad Plinth Walls at Front Porch • (N) Wood -clad Columns at Front Porch • (N) Asphalt Comp. Shingles, Class 'A', throughout • Painted (N) Wood Shutters and Window Boxes o 12 (E) Garage door to remain Avg. T.O.C. EL: 100.4' F. G. EL: 100.1 ' Typical Exterior Materials 1. Finished Grade (unchanged) 2. Existing Landscaping to remain 3. New Landscaping 4. New concrete porch / steps 5. New brick -clad seat wall 6. New brick -clad column base & painted wood column 7. New exterior support beam, from 4x8, painted 8. New wood bellyband, from 2x10, w/ watertable, from 2x4, painted 9. New wood fascia, from 2x8, painted 10. Exposed wood rafter tails 11. New wood trim, from 2x, painted 12. Existing wood siding, w/ new paint 13. New cedar shingles, stained 14. Existing exterior cement plaster, w/ new paint 15. New exterior cement plaster, painted 16. New asphalt composition shingles, Class 'A' 17. New GSM gutter and downspouts, painted 18. Existing window / door to remain 19. New aluminum -clad wood window w/ simulated true divided lites 20. New wood gable vent, painted 21. New exterior light - downcast light, max. output equivalent to 40W incandescent Avg. T.O. Curb = West Corner Elev. + East Corner Elev. 2 101.0' + 99.89' 2 100.4' [EW] Indicates Egress Windows that meet the requirements of the 2016 California Residential Code (CRC) Sec. 310 including, but not limited to the following: 1. Min opening area = 5.7 s.f. 2. Sill height no more than 44 inches above the floor 3. Min. opening height = 24 inches 4. Min. opening width = 20 inches 0 C N 0 �� O a a p U ) O o N uO N M E a 7 O) O c ,0 01 10 M U -� 00 v ^ a � �ma 10 c02a Or., U L D U N � 4 U N N 0 i i H N j �} N Q U U E 0 a) � N � U > Q w W V W N W }O Cie O Q > O o` p c"4 W >a > U-0 LO a <n � 0 N _ O L - E N 0 O o z Q -0 -O m Q Planning Submittal: 03/24/2022 ZL Planning Re -Submittal 01: 05/1 1 /2022 0 Planning Re -Submittal 02: 06/17/2022 Exterior Elevation: South A4. 1 2119 T.O. Ridge ±12'-2" T.O. Plate +8,-0" FF EL: 10, 0'-0" Garage FF ±-2'-2„ (N) T.O. R ±22'-5" (N) 2nd FI ±17'-6" (N) 2nd FI ±g'-6" T.O. Plate +8, 0„ FF EL: 10, 0' 0" Garage FF ±-2'-2„ 1 L /\ I J 1 1 1 1 L I V Y \.il I I V I 1• L t.il J I DG OF OE (DD 2 1 1 Vr.JVJV `1 Y 11V1 1. ` JI 1 /4" = 1 '-0" ( AD O C U p O pU nU O N u') N c) E 5 p c 7 O 10 10 -0 cn M � 00 v U — a � �ma � c�2a Or" U N L D U (D U N O a)DC: Q U U E N i C N 0 Q w V a N O /1/ 0 O p W > U -0 a <n � 0 N _ O - E N Q CN �O CD Q Planning Submittal: 03/24/2022 ZL Planning Re -Submittal 01: 05/1 1 /2022 0 Planning Re -Submittal 02: 06/17/2022 Exterior Elevation: East A4.2 2119 O O O O T.O. Ridge E f 12'-2" T.O. Plate El +8'-0" FF EL: 102.E 0'-0" F.G. EL: 100 N L/\IJ 1 11 1 V 11`JI I. 1 I I I 1 /4" = 1 '-0" 04 ( D3 ( D2 10 (N) T.O. Rid(, ±22'-5" Typical Exterior Materials 1. Finished Grade (unchanged) 2. Existing Landscaping to remain 3. New Landscaping 4. New concrete porch / steps 5. New brick -clad seat wall 6. New brick -clad column base & painted wood column 7. New exterior support beam, from 4x8, painted 8. New wood bellyband, from 2x10, w/ watertable, from 2x4, painted 9. New wood fascia, from 2x8, painted 10. Exposed wood rafter tails 11. New wood trim, from 2x, painted 12. Existing wood siding, w/ new paint 13. New cedar shingles, stained 14. Existing exterior cement plaster, w/ new paint 15. New exterior cement plaster, painted 16. New asphalt composition shingles, Class 'A' 17. New GSM gutter and downspouts, painted 18. Existing window / door to remain 19. New aluminum -clad wood window w/ simulated true divided lites 20. New wood gable vent, painted 21. New exterior light - downcast light, max. output equivalent to 40W incandescent 0 C p N O 5 p U O ) CD uO O N N M E 7 a ,0 O 10 32 CO M s3It rl� �ma 10 c�2a OK U Una U � N N O i i �} N Q U U E =� O � N � a) U > Q Sw L IU - ' •Cie • • I --j----- .I--I--.�..I '-` ' L---.I • I �aW�N�<I�� I I_ I i P .� I I LIj� �■Ik, L��■��LIJII�■�LI�c=-_- �■1 -� I I IN�N.IIH■N� ��Llll■���� I N L�I • _ �� �•��-� --- IYY1nll■n■■.■■■�■I■11■II■■I■I■II■1�-1 1I_nl■1■1��1 _ I___-- ___-- _ - - I I I • � •• • • • •_• wood Pointed • • • trims I 1■■■■1■1■11_II_■_I■_I■I IFF1117 I■I 111 11■■II■■■■■ .■11I L1I� �111U❑ ■ 1■11 I■nlu■IIEI-- I1�L�1■I.L.-.-..-.�-- .■-.. • • u_-❑I-❑ Nli�❑l --I�I. E L71. ❑❑ ❑❑❑iI❑❑ 1�1� ■:�■■:�1■:1■:1:1■:■��11�■■:■:�■■::1►I 11"�� u� i,.■�1■�■■:■ ■■1■1■11■I■1■ ■■■■■I■ � U❑i� �:�■�1.■■:.1■:n11:.1■:l■.■�■�.111. C: E 01 -_■1 ❑I II■11■■11■■■■■I■1■11 LLLLIJILL�41111L IIU❑��❑U� ❑ oilIo , . • ::I�f :l:m::::i�::la:i i::1 lil:lEmo:i o , �I II■11■■III■■■■1■1 CN D• (N) 2nd FL +9,-6„ T.O. Plate El +8, 0„ FF EL: 102.E 0'-0" F.G. EL: 100 /^ 1 1 `' r.J `1 J `1 �1 ` I `IV �1 I I `J I I. 1 `I `W I I I I \\ 1 1 /4" = 1 '-0" [EW] Indicates Egress Windows that meet the requirements of the 2016 California Residential Code (CRC) Sec. 310 including, but not limited to the following: 1. Min opening area = 5.7 s.f. 2. Sill height no more than 44 inches above the floor 3. Min. opening height = 24 inches 4. Min. opening width = 20 inches Planning Submittal: 03/24/2022 ZL Planning Re -Submittal 01: 05/1 1 /2022 0 Planning Re -Submittal 02: 06/17/2022 Exterior Elevations: North A4.3 1 2119 T.O. Rid( f 12'-2" T.O. Plat +8'-0" FF EL: 1 �ee F.G. EL: (N) T.O. ±22'-5" (N) 2nd ±17'-6" (N) 2nd +9,-6„ T.O. Plat +8, 0„ FF EL: 1 F.G. EL. 1 1 L/M ) 1 11 1�j LI V I It.JI 1. . . J I OA 1 /4" = 1'-0" OD 2 1 1`JNVJV`.1 `1`I Y...111`J1 1• .. VJI 1 /4" = 1 '-0" O C N p O pU nU O N uO N (OM E 5 p 7 O 10 01 10 M 00 a �ma � c02a Or" U N L U N ' U L N O L L �DC: Q U U E N i C 0 � N � U > Q � w V a N O /1/ 0 O p W > U -0 a <n � 0 N _ O - E N Q CN �O CD Q Planning Submittal: 03/24/2022 ZL Planning Re -Submittal 01: 05/1 1 /2022 0 Planning Re -Submittal 02: 06/17/2022 Exterior Elevations: West A4.4 2119 A D.S. 1'-4" Overhang (N) Class 'A' composition shingle roofing o/ 30# felt o/ (E) sheathing and roof framing (DB 2 A4.4 A5.1 (N) Class 'A' composition shingle roofing o/ 30# felt o/ (N) sheathing and roof framing, typ. E G D.S. T 2 2 A5.1 1 I I 1 I 1 2 A4.3 3 0 CII (N) Class 'A' composition shingle roofing o/ 30# felt o/ (N) sheathing and roof framing, typ. :12 1 1 4:12 (N) Skylight, typ. of (2) 1 2 Proposed Roof Plan I I I I 2 A5.1 2 A4.1 1 /4" = 1 '-0" Line of Second Fk wall below, typ. �— 2'-0" Overhang, UON Existina Roof Plan Line of First Floor wall below, typ. 1 /8" = 1 '-0" O C N p O a C3 pU nU O O N uO N 6 COM D O 0 7 O 10 -0 M cc) U—� v a - ma � c�2a OIr" U N L U N ' N L N } Q U U E i C } O N Q w W V N W O } �/ O O 0- O c� W U '0 a <n � N _ O L - C: E N O N O Z Q N -O CD Q Planning Submittal: 03/24/2022 ZL Planning Re -Submittal 01: 05/1 1 /2022 0 Planning Re -Submittal 02: 06/17/2022 Proposed Roof Plan A3. 1 2119 0 Storm Water Drainage: 1. All downspouts shall drain to planting areas. 2. Any new paving shall be sloped to drain into planting areas. 3. Rear Deck and Front Porch shall drain to planting areas 4. No drainage shall flow to adjacent properties. Equipment shall not exceed a maximum outdoor noise level (measured in A -weighted decibels, or dBA) of 60 dBA between the hours of 7:00 AM and 10:00 PM or 50 dBA between the hours of 10:00 PM and 7:00 AM, as measured from the property line of the property on which the equipment is located. All city or f per and othe Wat( necE (E) setb Site Plan 1 /8" = 1 '-0" r to assess all curb, 1 sidewalk Project Data Zoning R - 1 Occupancy R - 3 Al Building Code 2019 CBC Construction Type V-B ZL Lot Coverage Existing Lot Area 6,900 sf Allowed Lot Coverage, % 40 % Allowed Lot Coverage, sf 2,760 sf Lot Coverage - EXISTING (E) House 1 ,906 sf (E) Porch 139 sf Total 1,906 sf Existing Lot Coverage, % 28 sf Lot Coverage - PROPOSED (E) House 1 ,906 sf (N) Front Porch 200 sf (N) Rear Addition 162 sf (N) 2nd Floor Cantilever 79 sf Total 2,347 sf Proposed Lot Coverage, % 34 % Floor Area Ratio FAR, % 32 % FAR, sf 2,208 sf FAR, Additional sf 1,100 sf Total FA Allowed 3,308 sf Floor Area - EXISTING (E) House 1,906 sf Existing Floor Area 1 ,906 sf Floor Area - PROPOSED First Floor (inc. Garage) 2,014 sf (N) Front Porch 200 sf exempt, 25.30.060 Second Floor 1,236 sf Proposed Floor Area 3,250 sf Parking Proposed Bedrooms 7 rm Total Bedrooms 7 rm Req. Covered Parking 2 Req. Uncovered Parking 1 Total Parking 3 ZL [Impervious Areas Location Existing House + Garage Description Footprint Area 1,925 sf Exisitng Site Paving, Front Porch, 1,123 sf & Rear Deck Proposed House + Footprint 2,038 sf Garage Proposed Site Paving, Front Porch, & Rear Deck Existing Impervious Areas Proposed Impervious Areas 1,091 sf 3,048 sf (44.2% of 6,900 sf lot) 3,129 sf (45.3% of 6,900 sf lot) Site Notes 1. Topographic information used for design and contained in these Documents is derived from incidental measurements prepared by Architect and Civil Engineer. Contractor shall verify all grades during layout and coordinate discrepancies in conjunction with Architect and Civil Engineer. 2. All finished grades shall slope away from structure at 1 /4" per foot, for a min. 18" distance. 3. Drainage system components shown are schematic only. Contractor shall size all pipe, fittings, components to match plan. 4. Refer Building Floor Plans and Sections for all dimensional information. 5. Existing finish grades shall be restored upon completion of construction unless changes are specified in the Drawings. 6. Remove excess subgrade debris in work zone. Debris may include broken concrete, rocks, utilities and misc. submerged debris. 7. Roadways shall be maintained clear of construction equipment or materials at all times. Debris shall be removed from roadways and sidewalk immediately. Contractor shall sweep or wash road surfaces after operations that generate debris. 8. Dust control measures shall be implemented as necessary. 9. All backfill slopes shall be compacted to 90% min. 10. All exterior bearing walls less than five feet from the property line will be built of one hour fire -rated construction. 11. Addresses and Numbers shall contrast with their background, shall be a min. of 1 /2" stroke by 4" high. The power of such illumination shall not be normally switchable. 12. No trees are to be removed as part of this project. Public Works Notes 1. Any work in the City right-of-way, such as placement of debris bin in street, work in sidewalk area, public easements, and utility easements, is required to obtain an Encroachment Permit prior to starting work. Porta potty's are not allowed to be placed in the City right-of-way. 2. All work within City right-of-way shall comply with City Standards and Details. Standard Details are available at the City of Burlingame website. 3. Based on the scope of work, this is a "Type 1 " project that requires a Stormwater Construction Pollution Prevention Permit. This Permit is required prior to issuance of a Building Permit. An initial field inspection is required prior to the start of any construction (on private property or in the public right-of-way). 4. All damaged and displaced curb, gutter, and/or sidewalk fronting site must be replaced prior to final inspection of Building Permit. 5. Construction hours in the City Public right-of-way are limited to weekdays and non -City Holidays between 8am and 5pm. This includes construction hauling. 6. Per Municipal Code section 18.08.090, no storm water or underground water draining from any lot, building, or paved area shall be allowed to drain to adjacent properties nor shall this water be connected to the City's sanitary sewer system. Regardless of the slope of the source property, such water shall drain to either artificial or natural storm drainage facilities by gravity or pumping. 7. All water line connections to City water mains for services or fire line protection are to be installed per City standard procedures and material specifications. Contact City Water Department for connection fees. If required, all fire services and services 2" and over will be installed by builder. All underground fire service connections shall be submitted as separate Underground Fire Service permit for review and approval. 8. Sewer Backwater Protection Certification is required for the installation of any new sewer fixture per Ordinance No. 1710. The Sewer Backwater Protection Certificate is required prior to the issuance of Building Permit. 9. The project shall comply with the City's NPDES permit requirements to prevent storm water pollution. 10. All debris/garbage containers location shall be on property. In a situation where that is not possible, an encroachment permit is required from Public Works Department for placing debris/garbage containers in public right-of-way. No wet garbage fluid shall enter public right-of-way or the storm drain system. 11. It is the responsibility of the owner and/or contractor to notify Underground Service Alert (USA) at least 48 hours before the start of any excavation work. 12. No permanent structures are proposed beyond the property line and into the City Public right-of-way. Legend F Gas Meter Fw_1 Water Meter CO Sewer & Cleanout Cw (E) Cold water line S Sewer line E (E) Overhead electrical line D.S. (N) Down Spout 0 C p N O pU O nU u') O N N Cl)A � E 7 a ,0 _ O) O 0, CID (� v �ma 10 c�2a Or., U N (D ►• Zc N O H a) a� Q U U E �.� ��� i U > �0 Q Sw L IrA N W O } �/ O O O O` N L� a W -0 <n � O N _ O L O N O N OCN Z Q �o Coo_ Q Planning Submittal: 03/24/2022 ZL Planning Re -Submittal 01: 05/1 1 /2022 0 Planning Re -Submittal 02: 06/17/2022 Site Plan Al . I 1 P.A. Planting Area 2119