HomeMy WebLinkAboutReso - PC - 2020.08.10 - 8ADocuSign Envelope lD: DEA789.3-1 9924029-840A-8ECD93E4SD97
RECORDING REQUESTED BY:
Planning Department
City of Burlingame
WHEN RECORDED MAIL TO:
COMMUNITY DEVELOPMENT DEPARTMENT
CITY OF BURLINGAME
501 PRIMROSE ROAD
BURLINGAME, CA 94010
llulilltilt
'r$R
Resolution No. 2020-08.1 0-8a
2625 MARTINEZ DRIVE
025-062-080
2021-167808
10:37 am 12tOBt21 Rl Fee: NO FEE
Count of pages 4
Recorded in Official Records
County of San Mateo
Mark Church
Clerk-Recorder
liluiluilililiilil00031 illtlrllllill il[llllil llifl
TITLE OF DOCUMENT
I hereby certify this to be a full, true and correct copy of the
document it purports to be, the original of which is on file in my
office.
October 25 2021 a$$ffi&}rffq*&ryffi
r;Uh'€
.{
Date:
Kevin Gardiner, AICP, Community Development
,t(
RESOLUTION APPROVING CATEGORICAL EXEMPTION, DESIGN REVIEW, SPECIAL PERMIT,
AND HILLSIDE AREA CONSTRUCTION PERMIT
RESOLVED, by the Planning Commission of the City of Burlingame that:
WHEREAS, a Categorical Exemption has been prepared and application has been made for Desiqn
Review. Special Permit, and Hillside Area Construction Permit for a new one-story sinqle familv
dwellinq at 2625 Martinez Drive. Zoned R-1. Galen Ma and Tina Shi, propertv owners, APN: 025-062-
080;
WHEREAS, said matters were heard by the Planning Commission of the City of Burlingame on Auqust
10, at which time it reviewed and considered the staff report and all other written materials and
testimony presented at said hearing;
NOW, THEREFORE, it is RESOLVED and DETERMINED by this Planning Commission that
1. On the basis of the lnitial Study and the documents submitted and reviewed, and comments
received and addressed by this Commission, it is hereby found that there is no substantial evidence
that the project set forth above will have a significant effect on the environment, and categorical
exemption, per CEQA Section 15303 (a), which states that construction of a limited number of
new, small facilities or structures including one single family residence or a second dwelling unit
in a residential zone is exempt from environmental review. ln urbanized areas, up to three
single-family residences may be constructed or converted under this exception, is hereby
approved.
2. Said Design Review, Special Permit, and Hillside Area Construction Permit are approved
subject to the conditions set forth in Exhibit "A" attached hereto. Findings for such Design
Review, Special Permit, and Hillside Area Construction Permit are set forth in the staff report,
minutes, and recording of said meeting.
3. lt is further directed that a certified copy of this resolution be recorded in the official records of
the County of San Mateo.
Chairperson
T.St-*Mtb Secretary of the Planning Commission of the City of Burlingame, do
hereby certify that the foregoing resolution was introduced and adopted at a regular meeting of the
Planning Commission held on the 1Oth dav of Ausust.2020 by the following vote:
2625 tARTlltEZ DR - RESO 2020{18-10'8a
AYES: COilAROTO,GAUL
SARGENI SCHMID, TERRONES, TSE
NOES: NONE
ABSEiIT: LOFTIS
REGUSED: NONE
EXHIBIT ..A"
Conditions of Approval for Categorical Exemption, Design Review, Special Permit, & Hillside Area
Construction Permit
2625 Martinez Drive
Effective August 20, 2020
Page 1
1 that the project shall be built as shown on the plans submitted to the Planning Division date
stamped July 24, 2020, sheets A0.0 through L4.01 ;
that any changes to building materials, exterior finishes, windows, architectural features, roof
height or pitch, and amount or type of hardscape materials shall be subject to planning
Division or Planning Commission review (FYl or amendment to be determined by planning
staff);
that any changes to the size or envelope of the first or second floors, or garage which would
include adding or enlarging a dormer (s), shall require an amendment to this permit;
that any recycling containers, debris boxes or dumpsters for the construction project shall be
placed upon the private property, if feasible, as determined by the Community Development
Director; that demolition or removal of the existing structures and any grading or earth moving
on the site shall not occur until a building permit has been issued and such site work shall be
required to comply with all the regulations of the Bay Area Air Quality Management District;
that prior to issuance of a building permit for construction of the project, the project
construction plans shall be modified to include a cover sheet listing all conditions of approval
adopted by the Planning Commission, or City Council on appeal; which shall remain a part of
all sets of approved plans throughout the construction process. Compliance with all
conditions of approval is required; the conditions of approval shall not be modified or changed
without the approval of the Planning Commission, or City Council on appeal;
that all air ducts, plumbing vents, and flies shall be combined, where possible, to a single
termination and installed on the portions of the roof not visible from the street; and that these
venting details shall be included and approved in the construction plans before a Building
permit is issued;
that the project shall comply with the Construction and Demolition Debris Recycling
Ordinance which requires affected demolition, new construction and alteration projects to
submit a Waste Reduction plan and meet recycling requirements; any partial or full demolition
of a structure, interior or exterior, shall require a demolition permit;
4
A
b
7
8. that the project shall meet all the requirements of the California Building and Uniform Fire
Codes, in effect at time of building permit submittal, as amended by the City of Burlingame;
THE FOLLOWING CONDITIONS SHALL BE MET DURING THE BUILDING INSPECTION
PROCESS PRIOR TO THE INSPECTIONS NOTED IN EACH CONDITION:
that prior to scheduling the framing inspection the applicant shall provide a certification by the
project architect or residential designer, or another architect or residential design
professional, that demonstrates that the project falls at or below the maximum approved floor
area ratio for the property;
I
EXHIBIT'A"
Conditions of Approval for Categorical Exemption, Design Review, Special Permit, & Hillside Area
Construction Permit
2625 Martinez Drive
Effective August 20, 2020
Page 2
10 that prior to scheduling the foundation inspection, a licensed surveyor shall locate the
property corners, set the building footprint and certify the first floor elevation of the new
structure(s) based on the elevation at the top of the form boards per the approved plans; this
survey shall be accepted by the City Engineer;
11.prior to scheduling the framing inspection the project architect or residential designer, or
another architect or residential design professional, shall provide an architectural certification
that the architectural certification that the architectural details shown in the approved design
which should be evident at framing, such as window locations and bays, are built as shown
on the approved plans; architectural certification documenting framing compliance with
approved design shall be submitted to the Building Division before the final framing
inspection shall be scheduled:
12.that prior to scheduling the roof deck inspection, a licensed surveyor shall shoot the height of
the roof ridge and provide certification of that height to the Building Division; and
13.that prior to final inspection, Planning Division staff will inspect and note compliance of the
architectural details (trim materials, window type, etc.) to verify that the prqect has been build
according to the approved Planning and Building plans.
1
17�b � � � rF -r •y :_ '
V
f+{{^� 1
��
� Y
1y �y�•yF. �f t31ty
i �
II Fu
q 1
UPPER ROOF
+ 114'-9"
AMID ROOF N
+ 112'-3"
L1 FF
+ 100'-9"
FG AT BLDG
+ 100'-2"
ROOF CANOPY,
PTD FASCIA TYP.
PTD CLADDING
TO MATCH MTL-1
PROPOSED F.G., TYP.
(EXISTING FG SIMILAR)
PLAS-1, TYP.
(BLDG SETBACK 29'+ BYND)
WD DECK (AT GRADE)
DECLINING HEIGHT ENVELOPE (DASHED)
(N) TREE, SLD /
� / 1
Jr �
\
(J'
'+,- +.
}+
AVG FRONT + REAR \ — —
ELEVS AT SIDE YARD: i
(100 + 102.93) / 2 =
101.465' ... +:\++++++++++++++ + ++:+:++ + ........
I
6
o �
MTL-1
PROPOSED F.G., TYP. VPLAS-1, TYP. TRIM FRAME RAIN CHAIN
(EXISTING FG SIMILAR) SURROUND
WD-1 VERT.
SLAT SCREEN
0
0
MTL-1 CLAD DOOR
TILE-1 & SIDELITE PANEL
(TRANSLUCENT GLAZING)
0 I III 0 II /i II 0i
M BR
EGRESS
WD-1 VERT. SLAT SCREEN
ENTRY ROOF CANOPY,
PTD FASCIA
WD-1 CLAD GARAGE DOOR,
FLUSH W/ ADJ. SIDING
0
i/
ROOF CANOPY,
PTD FASCIA TYP.
MTL-
CLA DING
0 1' 2' 4'
� I
1 \
� 1
� � 1
l PLAS-1, SETBACK
40' & 17' BYN D
I
(N) TREE, SLD
\ 1 �
I
WD-1 SO
PLAS-1, T)
i
FINISH LEGEND:
PLAS-1:
3-COAT CEMENT PLASTER, SMOOTH OR FINE SAND FINISH,
WARM GRAY COLOR, TYP.
WD-1:
HORIZONTAL CEDAR T&G SIDING, SEMI -TRANSPARENT STAIN
VERTICAL CEDAR SLATS, SEMI -TRANSPARENT STAIN
TILE-1:
HORIZONTAL LINEAR TILE, WARM GRAY COLOR TO MATCH PLAS-1,
+/- 2" HT, RANDOM RUNNING BOND PATTERN
MTL-1:
DARK MTL PANEL TO MATCH WDW & DOOR FINISH, TYP.
FASCIAS:
SMOOTH FINISH, DARK PTD COLOR, TYP.
WDWS & DOORS:
ALUMINUM OR ALUM CLAD, DARK BRONZE ANODIZED FINISH TYP.
EGRESS OPENINGS FOR SLEEPING RMS:
ALL SLEEPING RMS SHALL HAVE EGRESS OPENINGS PER CRC R310 & SHALL HAVE 5.7
SF MIN. NET CLR OPENING AREA, 20" MIN. NET CLR WIDTH & 24" MIN. NET CLR HEIGHT.
BELOW ARE APPROX. NET CLEAR DIMS FOR BEDROOM EGRESS OPENINGS:
M BR: 43.1 SF 4'-5" W x 9'-9" H
BR 2: 12.3 SF 2'-2" W x 5'-8" H
BR 3: 12.3 SF 2'-2" W x 5'-8" H
BR 4: 10.7 SF 2'-2" W x 4'-11" H
0
i
<V
AVG FRONT + REAR
ELEVS AT SIDE YARD
(AT SETBACKS):
(99.34 + 98.45) / 2 =
0 1' 2' 4'
REAR ELEVATION
MAX HEIGHT
+ 129'-3"
(UPPER ROOF
AT ENTRY)
0
N MID ROOF
+ 112'-3" Y
LOW ROOF
+ 110'-9"
N
i
00
L1 FF
+ 100'-9"
MID ROOF
T.O. PLATE,,
INV
LOW ROOF
T.O. PLATE
EAST02
1 /4" = 1'
AVERAGE
FG AT BLDG T.O.CURB
+ 99'-3"
+ 100'-2"
AVG FRONT CORNER T.O. CURBS:
(99.95 + 98.53) / 2 = 99.24'
FRONT ELEVATION
EST011 /4" = 1'
In Al
ARCHITECTURE
WWW LNAL COM
650.678.4965
2625 Martinez Drive
Burlingame, GA 94010
APN#: 025-062-080
Private Residence
DRAWING RELEASE STATUS DATE
PLANNING 12/12/2019
PLANNING REVISION 1/15/2020
PLANNING REVISION 3/11/2020
PLANNING REVISION 5/21/2020
PLANNING REVISION Z L 7/10/2020
ISSUE --
DATE 11/11/2019
,JOB# 201913
SCALE AS NOTED
DRAWN BY --
SHEET TITLE
ELEVATIONS -
FRONT & REAR
SHEET #
A5ol
,LUPPER ROOF
+ 114'-9"
Co
AMID ROOF N
+ 112'-3"
L1 FF
+ 100'-9"
FG AT BLDG
+ 100'-2"
WD-1 VERT. SLAT
SCREEN BYND
FINISH I Fc.FNn.
PLAS-1:
3-COAT CEMENT PLASTER, SMOOTH OR FINE SAND FINISH,
WARM GRAY COLOR, TYP.
WD-1:
HORIZONTAL CEDAR T&G SIDING, SEMI -TRANSPARENT STAIN
VERTICAL CEDAR SLATS, SEMI -TRANSPARENT STAIN
TILE-1:
HORIZONTAL LINEAR TILE, WARM GRAY COLOR TO MATCH PLAS-1,
+/- 2" HT, RANDOM RUNNING BOND PATTERN
MTL-1:
DARK MTL PANEL TO MATCH WDW & DOOR FINISH, TYP.
FASCIAS:
SMOOTH FINISH, DARK PTD COLOR, TYP.
WDWS & DOORS:
ALUMINUM OR ALUM CLAD, DARK BRONZE ANODIZED FINISH TYP.
EGRESS OPENINGS FOR SLEEPING RMS:
ALL SLEEPING RIMS SHALL HAVE EGRESS OPENINGS PER CRC R310 & SHALL HAVE 5.7
SF MIN. NET CLR OPENING AREA, 20" MIN. NET CLR WIDTH & 24" MIN. NET CLR HEIGHT.
BELOW ARE APPROX. NET CLEAR DIMS FOR BEDROOM EGRESS OPENINGS:
M BR:
43.1 SF
4'-5" W x 9'-9" H
BR 2:
12.3 SF
2'-2" W x 5'-8" H
BR3:
12.3SF
2'-2" W x 5'-8" H
TILE-1
BR 4:
10.7 SF
2'-2" W x 4'-11" H
(BLDG SETBACK
33'+ BYND)
LOW ROOF W/
PTDFASCIA—\ +"+.++++"+.++++"+.++++"+.++++"+.++++"+.+++++,+.+++++,+.+++++,+.+++++,+.++++,. :,+:+:::+:+:++
+ :+::+:+ ++++ ............
+++ ++ +++
+++++++++++ ++ +:++.++++:+ + + + + + + + + + + + + + + ++:
............ ++ ........ : ... .. ..t+` - I+
t. ++i.
. . . . . . . . . . . . . +:+: ........ + .t++.+.+.+++++i+ + + + + + + ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ + + +++ +
t. ..
t+
\-+++++++++++++++++++++++ + + ++ + +\+++++++++++++++ +++++++++++++1 �:o ......... \ ++ + +
. . + . . . + + . . + . . . + . + 1 . . . + . .I . + . . . + . . . + . . . + . . . + . . .« . - + + . . + + . . + + . . + + . . . + . + . + . , + . . + . . . + . . . + + + + -
LOW ROOF CANOPY
W/ PTD FASCIA
ROOF CANOPY W/ PTD
FASCIA (SETBACK 43'+ BYND)
WD-1 VERT. �WD-1 SIDING \-PLAS-1, TYP. �DS OUTLETS, TYP. \-PLAS-1, TYP. �DS \-WD DECK (AT GRADE) \_WD-1 VERT VWD-1 VERT. SLAT PROPOSED F.G., TYP.
SLAT SCREEN SLATS 0/ SIDING SCREEN 0/ WDWS (EXISTING FG SIMILAR)
BYND
PLAS-1, TYP.
................
................
................
................
.................
................
................
...............+
................
.................
MTL-1 CLADDING
PLAS-1 (SETBACK 23'+ BYND)
...................
....................
.............
....................
...................
....................
...................
....... .......
+++++++++++++ +++++++++++++
i�
....... .......
....... .......
i�
....... .......
...... ......
....... .......
...... ......
....... .......
...... ......
....... .......
+++++++++++++L]+++++++++++++
...... ......
....... .....
--- �+
.�+
%+ %+
+4+ +�+
.o+o+
DS OUTLETS, TYP.
......... ..........
......... ..........
i�..+++.+++ +
BR 2
GRES
LOW -PROFILE
SKYLIGHTS BYND, TYP.
�i
BR 3
GRES
- - - - - - . .+O'.Q'
PROPOSED F.G., TYP.
(EXISTING FG SIMILAR)
PLAS-1, TYP.
0
//
(SIDE YARD LANDSCAPING NOT
SHOWN, SEE LANDSCAPE DWGS)
RIGHT SIDE ELEVATION (SOUTH) ng
1 /4" = 1'
0 1' 2' 4'
BR 4
EGRESS
00
0 1' 2' 4'
TILE-1 (SETBACK 20'+ BYND)
//
PTD
FASCIA MID ROOF
BYND � + 112'-3"
LOW ROOF
+ 110'-9"
L1 FF
+ 100'-9"
MTL-1 TRIM LWD-1 VERT.
FRAME SURROUND SLAT SCREEN FG AT BLDG
BYND + 100'-2"
LEFT SIDE ELEVATION (NORTH) n 1
1 /4" = 1'
In.
ARCHITECTURE
WWW. LNAL CCM
650.678.4965
2625 Martinez Drive
Burlingame, CA 94010
APN#: 025-062-080
Private Residence
DRAWING RELEASE STATUS DATE
PLANNING 12/12/2019
PLANNING REVISION 1/15/2020
PLANNING REVISION 3/11/2020
PLANNING REVISION 5/21/2020
PLANNING REVISION �4 7/10/2020
ISSUE --
DATE 11 /11 /2019
JOB # 201913
SCALE AS NOTED
DRAWN BY --
SHEET TITLE
ELEVATIONS -
LEFT & RIGHT SIDE
SHEET #
A5o2
4
MM
CURB = +99'-3"
IEW GARDEN
KIT
0 1' 2' 4'
0 1' 2' 4'
1
MID ROOF
+ 112'-3"
L1 FF
+ 100'-9°
FG AT "BLDG
+ 100'-2"
N-S SECTION LOOKING EAST 02
1 /4" = 1'
E-W SECTION LOOKING NORTH 0 1
1 /4" = 1'
In.
ARCHITECTURE
WWW. LNAL CCM
650.678.4965
2625 Martinez Drive
Burlingame, CA 94010
APN#: 025-062-080
Private Residence
DRAWING RELEASE STATUS DATE
PLANNING 12/12/2019
PLANNING REVISION 1/15/2020
PLANNING REVISION 3/11/2020
PLANNING REVISION 5/21/2020
PLANNING REVISION �4 7/10/2020
ISSUE
DATE 11 /11 /2019
JOB # 201913
SCALE AS NOTED
DRAWN BY --
SHEET TITLE
SECTIONS
SHEET #
A5o4
4
2621 MARTINEZ,
16.47' GARAGE SETBACK
(SEE SURVEY)
(N) TREE, SLD
`99
S,
99 96
20'-1"
100 11107.
A_- - - - -
F.O. CURB
(E) CONC.
r
SIDEWALK
EDGE OF
-
PLANTING
PROP LINE
I
(E) CURB
CUT
(SEELANDSCAPE
DWGS FOR ADDTL
(N) SS &
INFO)
SSCO
I
REPLACE
o------
____-----L
ALL CONC
FRONTING
SITE, SEE --
-
PUBLIC
I
WORK
NOTE #1
AT RIGHT
I
�
I
(N) NT Y
0 D
`AL
+ O�
IT
N
(N) DRIVE-
WAY
(N) STREET
TREE TO
REPLACE
(E) IN ROW
0
I
i�
+/ 5'-8" +/- 4'-6°
(VARIE
(N) DRIVEWAY
EXISTING HOUSE
ON ADJACENT
PROPERTY
99.9 i T T
k
GARDEN GARDEN
DS OUTLETS,
TYP.
EXT LIGHTING,
(SEE BLDG DEPT
NOTE #1)
I I
I I
I I
I
( FOR GARAGE
PARKING, SEE A2.1 )
(E) ON -SITE TREES TO BE
REMOVED, TYP. SEE
LANDSCAPE DWGS FOR
ADDTL INFO.
- 7
- - - - - - - - - - - - - --- - - - - - I /
SD b
FAC]
PROPOSED
RESIDENCE
( FOR ADDTL INFO,
SEE A2.1 )
L1 F.F. = +100' 9"
(N) TREE, SLD I
I
I
EXT LIGHTING,
(SEE BLDG DEPT
NOTE #1)�
GAS, WATER, DATA
& ELEC SERVICE
ENTRY POINTS, --
SD 9.8 TG 99�� SEE A2.1 DS OUTLETS,
TYP.
WATER OO --I N I O'O
— — — EEEL F_ gx
GAs Ha AC
('IT�`�o v -�'--
-- z--�----------------- ------
------ _ ---1-------+--Sp- ----- \ 99
018'-3„ \ o c� I ; ° O�
_ I I I
C C \ m
F / \ m \�
�:o I 71 EXISTING HOUSE
,2629 MARTINEZ, ON ADJACENT
14.98' GARAGE SETBACK PROPERTY
(SEE SURVEY)
� /
X
101
-- Co(+�-) 261 48 F
\ � IMASTER -- -
GARDEN
I I
I +
I SD
I
I
\ II o
ROOF OVERHANGS I
(DASHED), TYP. SEE
PLANS FOR INFO -
Q0 \I
� I
� I
C I
/ \ I
IOUTDOOR OUTDOOR / ---
DECK LAWN AREA
I
i I
(N) TREES & I
W PLANTS,SEE --- \
LANDSCAPE
SD
DWGS
I
I
ALL (E) NEIGHBOR TREES
TO REMAIN TYP, PROTECT
AS REQ'D
-A9g,91
CITY OF BURLINGAME PUBLIC WORK NOTES:
1 OWNER SHALL REPLACE ALL CURB, GUTTER, DRIVEWAY & SIDEWALK FRONTING SITE;
PLUG ALL EXISTING SANITARY SEWER LATERAL CONNECTIONS AND INSTALL A NEW 4"
LATERAL; ALL WATER LINE CONNECTIONS TO CITY WATER MAINS FOR SERVICES OR
FIRE LINE ARE TO BE INSTALLED PER CITY STANDARD PROCEDURES & SPECIFICATION,
AND ANY OTHER UNDERGROUND UTILITY WORKS WITHIN CITY'S RIGHT-OF-WAY.
ALL ABANDONED SEWER LATERAL OR WATER SERVICE SHALL BE DISCONNECTED AT
THE MAIN AND PER CITY REQUIREMENTS.) AN ENCROACHMENT PERMIT WILL BE
REQUIRED FOR THESE ITEMS.
2 NO PERMANENT FEATURES (WALLS, STEPS, ETC) SHALL EXTEND PAST OR ENCROACH
BEYOND THE PROPERTY LINES.
3. SEE SITE PLAN FOR PROPOSED UTILITY LOCATIONS; SEE SURVEY FOR (E) UTILITY
LOCATIONS.
4. PROPOSED FG AT PERIMETER OF HOUSE TO BE +/-100.17', SLOPE FG AWAY FROM
HOUSE AND TIE ALL DS TO STORM DRAIN SYSTEM, TYP. - SEE SITE PLAN.
STORM WATER SHALL NOT RUNOFF ONTO ADJACENT PROPERTIES, TYP.
CITY OF BURLINGAME BLDG DEPT. NOTES:
1 PROVIDE LIGHTING AT ALL EXTERIOR LANDINGS PER CRC 303.8 OR CBC 1008.2 & 1205.4.
2 MECHANICAL EQUIPMENT:
NEW A/C UNITS OR MECH EQPT INSTALLED ON THE EXT. OF THE BUILDING SHALL
NOT EXCEED A MAXIMUM OUTDOOR NOISE LEVEL (dBA) OF:
60 dBA DAYTIME ( 7AM - 10PM) OR 50 dBA NIGHTTIME (10PM - 7AM )
AS MEASURED FROM THE PROPERTY LINE (BMC 25.58.050).
Ar GENERAL SITE PLAN NOTES:
1 SEE SURVEY FOR ADDTL EXISTING INFO NOT NOTED HERE.
SEE SURVEY FOR ADDTL FRONT SETBACK INFO FOR THE BLOCK.
STORM DRAIN SYSTEM W/ AREA DRAINS -
TIE ALL DS TO SYSTEM & PROVIDE CURB 2 LANDSCAPE & HARDSCAPE INFO SHOWN HERE FOR GENERAL REFERENCE ONLY.
OUTLET TO STREET; SLOPE FG TO AREA SEE LANDSCAPE DWGS FOR ADDTL INFO NOT NOTED HERE.
DRAINS, TYP. (DESIGN BY PROJECT CIVIL
ENGINEER MACLEOD & ASSOCIATES)
3 SEE FLOOR PLANS A2.1 FOR BLDG DIMENSIONS AND INFO, TYP.
PROJECT
NORTH N
SITE PLAN 0 1
1 1 /8" = 1'-0
0 1' 4' "
InAl
ARCHITECTURE
WWW.LNALCOM
650.678.4965
2625 Martinez Drive
Burlingame, CA 94010
APN#: 025-062-080
Private Residence
DRAWING RELEASE STATUS DATE
PLANNING 12/12/2019
PLANNING REVISION 1/15/2020
PLANNING REVISION 3/11/2020
PLANNING REVISION 5/21/2020
PLANNING REVISION L4 7/10/2020
ISSUE --
DATE 11 /11 /2019
JOB # 201913
SCALE AS NOTED
DRAWN BY --
SHEET TITLE
SITE PLAN /
DEMO PLAN
SHEET #
Al ol