HomeMy WebLinkAboutReso - PC - 2020.04.27 - 8D3I
DocuSign Envelope lD: DEA78943-1 992-4629-840A-BECD93E45D97
RECORDING REQUESTED BY:
Planning Department
City of Burlingame
WHEN RECORDED MAIL TO:
COMMUNITY DEVELOPMENT DEPARTMENT
CITY OF BURLINGAME
501 PRIMROSE ROAD
BURLINGAME, CA 94010
2021-167795
10:37 am 12l$Al2'l Rl Fee: NO FEE
Count of Pages 6
Recorded in Official Records
CountY of San Mateo
Mark Church
tlltl rili[rilfir[ifi u nttxfinifinfm[fi [q tlp
Resolution No. 2020-04.27 -8d-3
RIGHT-OF.WAY ADJACENT TO 977 EL CAMINO REAL
APN: N/A, lN RIGHT-OF-WAY
TITLE OF DOCUMENT
I hereby certify this to be a full, true and correct copy of the
document it purports to be, the original of which is on file in my
office.
October 2021
&r*' 'ru hrli,nty
I.
E[*
*5
{rtrrthlfi
Date:
Kevin Gardiner, AICP, Community
t(
RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF BURLINGAi'E
APPROVING AN APPLICATION FOR A CONDITIONAL USE PERMIT TO INSTALL A NEW
SMALL CELL WIRELESS FACILITY (ANTENNA AND EQUIPMENT) ON AN EXISTING
WOOD UTILITY POLE LOCATED WTHIN THE RIGHT-OF-WAY ADJACENT
TO 977 EL CAMINO REAL
WHEREAS, on October 30,2017, Abigail Reed, an agent for AT&T, filed an application
with the city of Burlingame community Development Department - planning Division requesting
approval of the following request:
conditional use Permit to install a new small cell wireless facility (antenna and equipment)
on an existing wood utility pole located within the righfof-way adjacent to 977 El Camino
Real.
That the proposed wireless facility complies with all the requirements of chapter 25.77
and with all applicable requirements of other chapters of the Burlingame Municipal code;
That the proposed wireless facility, at the proposed location, will not be detrimental or
injurious to property or improvements in the vicinity and will not be detrimental to the public
health, safety, general welfare, or convenience, because 1) the proposed wireless facilityis located adjacent to an existing commercial use, 2) the proposed wireless facility
complies with the Federal communications commission's radio frequency (RF) emissions
regulations- (confirmed by an evaluation of the proposed wireless facility prepared by
Hammett & Edison, lnc., Consulting Engineers, dated September 26,'2017, and aiindependent review by CTC Technotogy & Energy, dated December 2019) and 3) the
proposed wireless facility, consisting of an antenna and associated equipment mounted
on an existing PG&E owned wood utility pole, will be slighfly wider than the existing pole
and will be concealed with a shield and painted to match the utility pole.
That the proposed use will be located and conducted in a manner in accord with the
Burlingame General Plan and the purposes of the Zoning Code.
1
RESOLUTTON NO. 2020-04.27-8d3-ECR
WHEREAS, on December'19, 2019 the Planning Commission conducted a noticed public
hearing (action meeting) to review and comment upon the proposed project. At that time the
Commission continued the application with the direction for the applicant to provide alternative
designs and information regarding the necessity to close significant gaps in coverage; and
WHEREAS, on April 27, 2020 the planning commission conducted a noticed public
hearing (action meeting). Following consideration of all information contained in the April 27,
2020 staff report to the Planning Commission regarding the project, all written correspondence,
and all public comments received at the public hearing, the Planning Commission grants approval
of the application for a Conditional Use Permit based on the following findings:
Conditional Use Permit Findinqs:
A
RESOLUTTON NO. 2020-04.27-8d3-ECR
NOW, THEREFORE, BE lT RESOLVED by the Planning Commission of the City of Burtingame,
that:
On the basis of the documents submitted and reviewed, and comments received and
evaluated, the Planning commission finds that there is no substantial evidence that the
project set forth above will have a significant effect on the environment. The planning
Commission further finds that categorical exemption, per CEeA Section 15303, which
states that construction and location of limited numbers of new, small facilities or
structures; installation of small new equipment and facilities in small structures; and the
conversion of existing small structures from one use to another where only minor
modifications are made in the exterior of the structure, is applicable to this project and is
approved.
A conditional Use Permit is approved for the project subject to the following conditions of
approval. Findings for the Conditional Use Permit are set forth in the staff report, minutes,
and recordings of the said meeting. Conditions of approval:
that the conditional use permit to install a new small cell wireless communication facility
on an existing PG&E wood utility pole, located within the right-of-way adjacent to 977 El
Camino Real, consisting of a cylindrical antenna, extension on top of the utility pole, one
smartpole meter, two radio remote units, two twin diplexers, one ground bar, and one
electric load center, shall be valid for ten ('10) years from the date of approval. At least
one hundred twenty (120) days prior to the expiration of the initial ten (.lO) year term, the
applicant shall complete and submit a renewal application to the Community Development
Director;
that the project shall be built as shown on the plans submitted to the planning Division
date stamped April 18, 201 9, sheets T-1 , cN-1 , A-1 through A-4.2, E-1 and E-2;
that prior to commencing any work at the site, the contractor commissioned by the
applicant to perform the work shall obtain all required permits, such as a construction
Encroachment Permit and stormwater Pollution Prevention permit from the Department
of Public Works - Engineering Division;
that all units must be at least seven (7) feet clear and above the highest adjacent finished
grade, no exceptions shall be allowed;
that the wireless communication facility shall operate in conformance with all applicable
provisions of Chapter 25.77 of the Burlingame Municipal Code (Wireless
communications); where any conflicts exist between the applicable provisions of that
chapter and this approval, the more restrictive provision shall apply;
1
4
2
B.
2.
3.
6
RESOLUTTON NO. 2020-04.27-8d3-ECR
that the facility shall meet or exceed current standards and regulations of the FCC, the
FAA, and any other agency of the state or federal government with the authority to regulate
wireless communication facilities. lf such standards and regulations are changed and are
made applicable to existing facilities, the owners of the facilities governed by this chapter
shall bring such facilities into compliance with such revised standards and regulations
within six (6) months of the effective date of such standards and regulations, unless a
different compliance schedule is mandated by the controlling state or federal agency.
Failure to bring the facility into compliance with such revised standards and regulations
shall constitute grounds for the removal of the facilities at the owner's expense, revocation
of any permit or imposition of any other applicable penalty;
that the facility shall be constructed of graffiti-resistant materials and shall be painted with
non-reflective material consistent with the color scheme on the utility pole;
that signage in, on or near the facility shall be prohibited with the exception of warning and
informational signs, which shall be designed with minimal aesthetic impact;
that within forty-five (45) days of commencement of the facility operation, the applicant
shall conduct a posf installation field test to confirm that the radio frequency (RF) exposure
levels comply with FCC Rules and Regulations and with City noise regulations, shall
submit the comprehensive report to the City, and if necessary, agree to prompfly correct
any noncompliance;
that the applicant shall report to the City every five (5) years from the date of
commencement of the facility operation, a review of the condition of the facility, of the
facility's compliance with federal and state regulations and of the facility's compliance with
the provisions of this chapter and the conditions of approval. The applicant shall also
provide updated contact information for the owner and the applicant and verifiable
confirmation information as to what carrier(s) are using the facility;
that the applicant shall procure and maintain a city business license, contact information
for the applicant, for the agent responsible for maintenance of the facility and for
emergency contact;
that the applicant shall either secure a bond, letter of credit or other similar financial
assurance, in a form acceptable to the city, for the removal ofthe facility in the event that
its use is abandoned, its operation is ceased or the approval is terminated;
that maintenance and repairs to facility shall be permitted provided that such maintenance
and repair does not enlarge or extend the facility structure or equipment enclosures or
change the number, type, dimensions, of the antenna or related equipment;
7
I
10
11
12
13
3
14.
'15
16
17
18
'19
20
RESOLUTTON NO. 2020-04.27-8d3-ECR
that if the applicant intends to substitute the equipment installed pursuant to this permit
with subsequently-developed technology, such as "5G" equipment, the applicant or
responsible party shall provide sixty (60) days prior notice to the City and secure any
necessary permits before commencing such work;
that current contact information of the person or entity responsible for maintaining and
repairing the facility shall be provided to and maintained by the community Development
Department;
that the facility shall be kept clean and free of graffiti, titter and debris. Lighting, walls,
fences, shields, cabinets, and poles, shall be maintained in good repair and free of graffiti
and other forms of vandalism, and any damage from any cause, including degradation
from wind and weather, shall be repaired as soon as reasonably possible to minimize
occurrences of dangerous conditions or visual blight. Graffiti shall be removed from any
facility as soon as practicable, and in no instance more than two (2) business days from
the time of notification by any person or entity;
that except for emergency repairs, testing and maintenance activities that will be audible
beyond the property line shall only occur between the hours of 8:00 a.m. and 6:00 p_m. on
Monday through Friday, excluding holidays;
that the service provider shall notify the community Development Director of the intent to
vacate a site at least thirty (30) days prior to the vacation;
that if the facility site is not operated for a continuous period of twelve (12) months, the
conditional use Permit shall be deemed terminated unless before the end of the twelve
(12) month period:
(1)The Community Development Director has determined that the same operator
resumed operation; or
The City has received an application to transfer the permit to another service
provider.
(2)
that no later than ninety (90) days from the date the facility is determined to have ceased
operation or the Provider has notified the community Development Director of the intent
to vacate the site, the owner of the wireless communication facilities or the owner of the
property on which the facility is sited shall remove all equipment and improvements
associated with the use and shall restore the site to its original condition as required by
the community Development Director. The provider or owner may use any bond or other
assurances provided by the operator to do so. The owner or his or her agent shall provide
written verification of the removal of the facility within thirty (30) days of the date the
removal is completed.
4
RESOLUTTON NO. 2020-04.27-8d3-ECR
Chairperson
I,
the City of Burlingame, do hereby certify that the foregoing resolution was introduced and adopted
at a regular meeting of the Planning Commission held on the 27th dav of April. 2020, by the
following vote:
97ZEL GAI|{9.REAL - REso 2020{I,r.27{d3+cRAYES: COiIAROTO, GAUL LOfuS,
-
SARGENI SCHI|D, TERROT{ES, TsENOES: NOiIE
ABSEI{T r{O]{E
RECUSED: NONE
Richard Teno nes
(
Secretary of the Planning Commission of
PROJECT DESCRIPTION
THIS IS AN UNMANNED WIRELESS TELECOMMUNICATION FACILITY FOR AT&T
MOBILITY CONSISTING OF THE INSTALLATION AND OPERATION OF AN ANTENNA
AND ASSOCIATED EQUIPMENT ON A PROPOSED WOOD UTILITY POLE IN THE
PUBLIC RIGHT OF WAY.
SCOPE OF WORK & SITE COMPLETION CHECKLIST
• ANTENNA & ASSOCIATED EQUIPMENT BOXES - INSTALL A NEW
TELECOMMUNICATION ANTENNA AND EQUIPMENT BOXES ON AN
PROPOSED WOOD UTILITY POLE ON G095 COMPLIANT STANDOFF
BRACKET. INSTALLATION CONSISTS OF (1) CANISTER ANTENNA, (2) TWIN
DIPLEXERS, (1) 4415 RADIO WITH PSU-08 & (1) 4426 RADIO WITH PSU-08 IN
SOLAR SHIELDS, (1) SMARTPOLE METER, (1) LOAD CENTER.
• CABLING - CABLING TO BE INSTALLED IN A TIDY MANNER WITHOUT EXCESS
CABLE LOOPS
• SPACING OF SUPPORT ELEMENTS - SUPPORT EQUIPMENT (E.G. RRUS) TO BE
CLUSTERED (VERTICALLY) AS CLOSE AS TECHNICALLY FEASIBLE ON POLE.
• LOGO REMOVAL - ALL EQUIPMENT LOGOS, OTHER THAN THOSE REQUIRED
BY REGULATION (E.G. NODE IDENTIFICATION) SHALL BE PAINTED OVER OR
REMOVED. RAISED OR DEPRESSED TEXT ON RRUS OR OTHER EQUIPMENT, IF
PRESENT, SHALL BE SANDED OFF OR SIMILARLY REMOVED / FILLED.
• SIGNAGE - FCC MANDATED RF WARNING SIGNAGE SHALL FACE OUT TO
STREET WHEN PLACED IN FRONT OF, OR NEAR A WINDOW. SIGNAGE
SHALL FACE TOWARD A BUILDING IF THERE IS NO WINDOW.
• ALL CABLING, ANTENNAS, AND EQUIPMENT TO BE PAINTED TO MATCH
POLE
CODE COMPLIANCE
ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN
ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS
ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE
PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE
CODES.
1. 2016 CALIFORNIA ADMINISTRATIVE CODES (INCL. TITLES 24 & 25)
2. 2016 CALIFORNIA BUILDING CODE
3. 2016 CALIFORNIA ELECTRICAL CODE
4. 2016 CALIFORNIA MECHANICAL CODE
5. 2016 CALIFORNIA PLUMBING CODE
6. 2016 CALIFORNIA FIRE CODE
7. 2016 CALIFORNIA GREEN BUILDING CODE
8. 2016 CALIFORNIA ENERGY CODE
9. 2016 SAN FRANCISCO CODE AMENDMENTS
10. 2016 SAN FRANCISCO BUILDING CODE AMENDMENTS
11. 2016 SAN FRANCISCO ELECTRICAL CODE AMENDMENTS
12. 2016 SAN FRANCISCO MECHANICAL CODE AMENDMENTS
13. 2016 SAN FRANCISCO PLUMBING CODE AMENDMENTS
14. 2016 SAN FRANCISCO FIRE CODE AMENDMENTS
15. 2016 SAN FRANCISCO GREEN BUILDING CODE AMENDMENTS
16. 2016 SAN FRANCISCO HOUSING CODE
DISABLED ACCESS REQUIREMENTS
FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION, ACCESSIBILITY
REQUIREMENTS ARE NOT REQUIRED, IN ACCORDANCE WITH CALIFORNIA
BUILDING CODE, CODE OF REGULATIONS, TITLE 24, PART 2, VOLUME 1,
CHAPTER 1 1 B, DIVISION 2, SECTION 11 B-203.5
VICINITY MAP
DIRECTIONS FROM AT&T's OFFICE
DIRECTIONS FROM AT&T's OFFICE AT 5001 EXECUTIVE PARKWAY, SAN RAMON, CA
1. HEAD NORTHEAST ON BISHOP DR TOWARD SUNSET DR
2. TURN RIGHT ONTO SUNSET DR
3. TURN RIGHT ONTO BOLLINGER CANYON RD
4. TURN LEFT ONTO NORRIS CANYON RD
5. TURN LEFT ONTO CROW CANYON RD
6. TURN LEFT ONTO E CASTRO VALLEY BLVD
7. TURN RIGHT TO MERGE ONTO 1-580 W
8. KEEP LEFT AT THE FORK TO CONTINUE ON 1-238 N, FOLLOW SIGNS FOR 1-880
9. TAKE EXIT 16A FOR INTERSTATE 880 S TOWARD SAN JOSE/SAN MATEO BRIDGE
10. TAKE EXIT 27 TO MERGE ONTO CA-92 W TOWARD SAN MATEO BRIDGE/JACKSON ST
11. TAKE EXIT 13B TO MERGE ONTO US- 101 N TOWARD SAN FRANCISCO
12. TAKE EXIT 419B FOR BROADWAY
13. TURN RIGHT ONTO OLD BAYSHORE HWY
14. TURN RIGHT ONTO BROADWAY
15. TURN LEFT ONTO CALIFORNIA DR
16. TURN RIGHT ONTO SANCHEZ AVE
17. TURN LEFT ONTO EL CAMINO REAL
OCCUPANCY AND CONSTRUCTION TYPE
OCCUPANCY: N/A
CONSTRUCTION TYPE: G.O. 128 AND 2009 AASHTO 5TH EDITION
STANDARD
SITE NUMBER
FA#:
SITE NAME:
SITE ADDRESS
COUNTY:
SITE TYPE:
HUB LOCATION:
POLE OWNER:
SFOK02 017
XXXXXXXX
CRAN RSFR SFOK2 017
977 EL CAMINO REAL
BURLINGAME, CA 94010
SAN MATED
PG&E WOOD UTILITY POLE
..�.�.�... .
PROJECT INFORMATION
Property Information:
Site Name: CRAN_RSFR_SFOK2_017
Site Number: SFOK02 017
Site Address: 977 EL CAMINO REAL
BURLINGAME, CA 94010
A.P.N. Number: ----
Current Zoning: N/A - PUBLIC RIGHT OF WAY
Jurisdiction: CITY OF BURLINGAME
Latitude: N 37 34' 52.61"
Longitude: W 122021' 40.41"
Elevation: +/- 37.9' AMSL (NAVD88)
Power Agency:
SFPUC
525 GOLDEN GATE AVENUE
SAN FRANCISCO, CA 94120
Telephone Agency:
AT&T
525 MARKET STREET
SAN FRANCISCO, CA 94105
ph: (415) 778-1231
PROJECT TEAM
Agent: Project Manager:
Jimmy Stillman
Jimmy Stillman
Modus-Corporation, Inc.
Modus-Corporation, Inc.
240 Stockton Street, 3rd Floor
240 Stockton Street, 3rd Floor
San Francisco, CA 94108
San Francisco, CA 94108
ph: (530) 913-9577
ph: (530) 913-9577
email: jstillman@modus-corp.com
email: jstillman@modus-corp.com
Construction Manager:
Architect / Engineer of Record:
Kresston Haynes
Borges Architectural Group, Inc.
Modus-Corporation, Inc.
1478 Stone Point Drive, Suite 350
240 Stockton Street, 3rd Floor
Roseville, CA 95661
San Francisco, CA 94108
contact: Brendan P. McNulty
ph: (209) 938-7251
ph: (916) 782-7200
email: khaynes@modus-corp.com
email: telecomgroup@borgesarch.com
AT&T Project Manager:
Marc Grabisch, SAQ PM
AT&T Mobility
5001 Executive Parkway
San Ramon, CA 94583
ph: (925) 549-9671
email: mg3871<@att.com
AT&T Construction Manager:
Leo Ruazol, CX PM
AT&T Mobility
5001 Executive Parkway
San Ramon, CA 94583
ph: (650) 787-6814
email: LR2164@att.com
RF Manager:
Jeric Lizardo
AT&T Mobility
5001 Executive Parkway
San Ramon, CA 94583
ph: (925) 365-0155
email:j8771@att.com
GENERAL CONTRACTOR NOTES
DO NOT SCALE DRAWINGS
THESE DRAWINGS ARE FORMATTED TO BE FULL SIZE AT 36" x 24" (D1). CONTRACTOR SHALL VERIFY ALL
PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOBSITE AND SHALL IMMEDIATELY
NOTIFY THE ARCHITECT/ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH
THE WORK OR MATERIAL ORDERS OR BE RESPONSIBLE FOR THE SAME.
SHEET INDEX
SHEET NO. SHEET TITLE
T-1
GN-1
TITLE SHEET
GENERAL NOTES
C-1
SURVEY
A-1
SITE PLAN
A-2
ENLARGED SITE PLAN & ANTENNA PLAN
A-3
ELEVATIONS
A-4
DETAILS
E-1 SINGLE LINE DIAGRAM &PANEL SCHEDULE
E-2 POLE GROUND & RISER DIAGRAM & DETAILS
800m227w2600
Call 2 Full Working Days In Advance
IS "Iftomm a t & t
5001 EXECUTIVE PARKWAY
SAN RAMON, CA 94583
M..
M0DU$
modus-corp.com
240 STOCKTON STREET, 3RD FLOOR
SAN FRANCISCO, CA 94108
borgesarch.com
1478 STONE POINT DRIVE, SUITE 350
ROSEVILLE CA 95661
916 782 7200 TEL
916 773 3037 FAX
3
06/12/19
100% CD Rev 2
2
02/22/18
100% CD Rev 1
1
12/04/17
100% CD Submittal
0
09/14/17
90% CD Submittal
REV
DATE
DESCRIPTION
SITE NUMBER:
SFOK02 017
SITE ADDRESS:
977 EL CAMINO REAL
BURLINGAME, CA 94010
STAMP
DMe y�r SA Fr
,
Fr
* m No. C11535
Jj9�Pq 09-31)1>,
tF OF CA \F
DRAWN BY: A.P.E. PROJECT NO.: T-16509-86
CHECK BY: B.P.M.
SHEET TITLE
TITLE SHEET
SHEET NO.
T=1
ABBREVIATIONS: SYMBOL LEGEND:
A.B. ANCHOR BOLT IN. (") INCH(ES)
ABV. ABOVE INT. INTERIOR
ACCA ANTENNA CABLE COVER ASSEMBLY LB.(#) POUND(S)
ADD'L ADDITIONAL L.B. LAG BOLTS 1 1
A.F.F. ABOVE FINISHED FLOOR L.F. LINEAR FEET (FOOT) A-300 A-300 BLDG. SECTION GROUT OR PLASTER
A.F.G. ABOVE FINISHED GRADE L. LONG(ITUDINAL)
ALUM. ALUMINUM MAS. MASONRY (E) BRICK
ALT. ALTERNATE MAX. MAXIMUM
ANT. ANTENNA M.B. MACHINE BOLT A5 WALL SECTION
APPRX. APPROXIMATE(LY) MECH. MECHANICAL A-slo (E) MASONRY
ARCH. ARCHITECT(URAL) MFR. MANUFACTURER
AWG. AMERICAN WIRE GAUGE MIN. MINIMUM CONCRETE
BLDG. BUILDING MISC. MISCELLANEOUS
BLK. BLOCK MTL. METAL D5 DETAIL = _ _ = EARTH
BLKG. BLOCKING (N) NEW A-soo
BM. BEAM NO.(#) NUMBER GRAVEL
B.N. BOUNDARY NAILING N.T.S. NOT TO SCALE CI
BTCW. BARE TINNED COPPER WIRE O.C. ON CENTER A-113 PLYWOOD
B.O.F. BOTTOM OF FOOTING OPNG. OPENING
B/U BACK-UP CABINET P/C PRECAST CONCRETE A4 C4 ELEVATION
CAB. CABINET PCs PERSONAL COMMUNICATION SERVICES A-113 A-]13 SAND
CANT. CANTILEVER (ED) PLY. PLYWOOD Al
C.I.P. CAST IN PLACE PPC POWER PROTECTION CABINET A-113 PLYWOOD
CLG. CEILING PRC PRIMARY RADIO CABINET
CLR. CLEAR P.S.F. POUNDS PER SQUARE FOOT SAND
COL. COLUMN P.S.I. POUNDS PER SQUARE INCH
CONC. CONCRETE P.T. PRESSURE TREATED 001 DOOR SYMBOL
CONN. CONNECTION(OR) PWR. POWER (CABINET) (E) STEEL
CONST. CONSTRUCTION QTY. QUANTITY
CONT. CONTINUOUS RAD.(R) RADIUS WINDOW SYMBOL
10 MATCH LINE
d PENNY (NAILS) REF. REFERENCE
DBL. DOUBLE REINF. REINFORCEMENT(ING) �3 TILT -UP PANEL MARK GROUND CONDUCTOR
DEPT. DEPARTMENT REQ'D/ REQUIRED
D.F. DOUGLAS FIR RGS. RIGID GALVANIZED STEEL OH OVERHEAD SERVICE CONDUCTORS
DIA. DIAMETER SCH. SCHEDULE — — PROPERTY LINE
DIAG. DIAGONAL SHT. SHEET Tel TELEPHONE CONDUIT
DIM. DIMENSION SIM. SIMILAR — CENTERLINE
DWG. DRAWING(S) SPEC. SPECIFICATIONS Pwr POWER CONDUIT
DWL. DOWEL(S) SQ. SQUARE+0
EA. EACH S.S. STAINLESS STEEL ELEVATION DATUM Coate- COAXIAL CABLE
EL. ELEVATION STD. STANDARD
ELEC. ELECTRICAL STL. STEEL A GRID/COLUMN LINE 0 CHAIN LINK FENCE
ELEV. ELEVATOR STRUC. STRUCTURAL
EMT. ELECTRICAL METALLIC TUBING TEMP. TEMPORARY WOOD FENCE
E.N. EDGE NAIL THK. THICK(NESS) 3 KEYNOTE,
ENG. ENGINEER T.N. TOE NAIL DIMENSION ITEM
EQ. EQUAL T.O.A. TOP OF ANTENNA
KEYNOTE,
EXP. EXPANSION T.O.C. TOP OF CURB 2
CONSTRUCTION ITEM
EXST.(E) EXISTING T.O.F. TOP OF FOUNDATION
EXT. EXTERIOR T.O.P. TOP OF PLATE (PARAPET) W 3 WALL TYPE MARK
FAB. FABRICATION(OR) T.O.S. TOP OF STEEL
F.F. FINISH FLOOR T.O.W. TOP OF WALL
F.G. FINISH GRADE TYP. TYPICAL OFFICE ROOM NAME
FIN. FINISH(ED) U.G. UNDER GROUND 101 ROOM NUMBER
FLR. FLOOR U.L. UNDERWRITERS LABORATORY
FDN. FOUNDATION U.N.O. UNLESS NOTED OTHERWISE
F.O.C. FACE OF CONCRETE V.I.F. VERIFY IN FIELD
F.O.M. FACE OF MASONRY W WIDE (WIDTH)
F.O.S. FACE OF STUD w/ WITH
F.O.W. FACE OF WALL WD. WOOD
F.S. FINISH SURFACE W.P. WEATHERPROOF
FT.(') FOOT (FEET) WT. WEIGHT
FTG. FOOTING CL CENTERLINE
G. GROWTH (CABINET) R PLATE, PROPERTY LINE
GA. GAUGE
GI. GALVANIZE(D)
G.F.I. GROUND FAULT CIRCUIT INTERRUPTER
GLB. (GLU-LAM) GLUE LAMINATED BEAM
GPS GLOBAL POSITIONING SYSTEM
GRND. GROUND
HDR. HEADER
HGR. HANGER
HT. HEIGHT
ICGB. ISOLATED COPPER GROUND BUS
[..FNFRAI NOTFS-
1. THESE NOTES SHALL BE CONSIDERED A PART OF THE WRITTEN SPECIFICATIONS, CONTRACT AND CONSTRUCTION DOCUMENTS.
2. THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES, AND LABOR NECESSARY TO COMPLETE ALL
INSTALLATIONS AS INDICATED ON THE PLANS AND IN THE CONTRACT DOCUMENTS.
3. PRIOR TO THE SUBMISSION OF BIDS, THE CONTRACTOR(S) SHALL VISIT THE JOB SITE(S) AND BE RESPONSIBLE FOR ALL CONTRACT
DOCUMENTS, FIELD CONDITIONS AND DIMENSIONS, AND CONFIRM THE WORK MAY BE ACCOMPLISHED PER THE CONTRACT DRAWINGS.
ANY DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION OF THE IMPLEMENTATION ENGINEER AND ARCHITECT / ENGINEER PRIOR TO
BID SUBMITTAL.
4. THE CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED ON ANY WORK NOT CLEARLY DEFINED OR IDENTIFIED IN THE
CONTRACT AND CONSTRUCTION DOCUMENTS BEFORE STARTING ANY WORK.
5. ALL WORK PERFORMED AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND
ORDINANCES, INCLUDING APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS.
6. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS. IF THE
RECOMMENDATIONS ARE IN CONFLICT WITH THE CONTRACT AND CONSTRUCTION DOCUMENTS AND/OR APPLICABLE CODES OR
REGULATIONS, REVIEW AND RESOLVE THE CONFLICT WITH DIRECTION FROM THE IMPLEMENTATION ENGINEER AND ARCHITECT/ENGINEER
OF RECORD PRIOR TO PROCEEDING.
7. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND
PROCEDURES AND FOR COORDINATION OF ALL PORTIONS OF THE WORK UNDER THE CONTRACT INCLUDING CONTACT AND
COORDINATION WITH THE IMPLEMENTATION ENGINEER AND WITH THE AUTHORIZED REPRESENTATIVE OF ANY OUTSIDE POLE OR PROPERTY
OWNER.
8. THE CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS, INCLUDING BUT NOT LIMITED TO PAVING,
CURBS, VEGETATION, GALVANIZED SURFACE OR OTHER EXISTING ELEMENTS AND UPON COMPLETION OF THE WORK, REPAIR AND
DAMAGE THAT OCCURRED DURING CONSTRUCTION TO THE SATISFACTION OF AT&T MOBILITY.
9. CONTRACTOR IS TO KEEP THE GENERAL AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DIRT, DEBRIS, RUBBISH, AND REMOVE
EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY. LEAVE PREMISES IN CLEAN CONDITION DAILY.
10. PLANS ARE INTENDED TO BE DIAGRAMMATIC ONLY AND SHOULD NOT BE SCALED UNLESS OTHERWISE NOTED. RELY ONLY ON ANNOTATED
DIMENSIONS AND REQUEST INFORMATION IF ADDITIONAL DIMENSIONS ARE REQUIRED.
11. THE EXISTENCE AND LOCATION OF UTILITIES AND OTHER AGENCY'S FACILITIES WERE OBTAINED BY A SEARCH OF AVAILABLE RECORDS.
OTHER FACILITIES MAY EXIST. CONTRACTOR SHALL VERIFY LOCATIONS PRIOR TO START OF CONSTRUCTION AND USE EXTREME CARE AND
PROTECTIVE MEASURES TO PREVENT DAMAGE TO THE FACILITIES. CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF UTILITIES OR
OTHER AGENCY'S FACILITIES WITHIN THE LIMITS OF THE WORK, WHETHER THEY ARE IDENTIFIED IN THE CONTRACT DOCUMENTS OR NOT.
12. THE CONTRACTOR SHALL NOTIFY UNDERGROUND SERVICE ALERT (800) 227-2600, AT LEAST TWO WORKING DAYS PRIOR TO START OF ANY
EXCAVATION.
DEFINITIONS:
1. "TYPICAL" OR "TYP" MEANS THAT THIS ITEM IS SUBSTANTIALLY THE SAME ACROSS SIMILAR CONDITIONS. "TYP" SHALL BE UNDERSTOOD TO
MEAN "TYPICAL WHERE OCCURS" AND SHALL NOT BE CONSIDERED AS WITHOUT EXCEPTION OR CONSIDERATION OF SPECIFIC
CONDITIONS.
2. "SIMILAR" MEANS COMPARABLE TO CHARACTERISTICS FOR THE CONDITION NOTED. VERIFY DIMENSIONS AND ORIENTATION ON PLAN.
3. "AS REQUIRED" MEANS AS REQUIRED BY REGULATORY REQUIREMENTS, BY REFERENCES STANDARDS, BY EXISTING CONDITIONS, BY
GENERALLY ACCEPTED CONSTRUCTION PRACTICE, OR BY THE CONTRACT DOCUMENTS.
4. "ALIGN" MEANS ACCURATELY LOCATE FINISH FACES OF MATERIALS IN THE SAME PLANE.
5. THE TERM "VERIFY" OF "V.I.F." SHALL BE UNDERSTOOD TO MEAN "VERIFY IN FIELD WITH ENGINEER" AND REQUIRES THAT THE CONTRACTOR
CONFIRM INTENTION REGARDING NOTED CONDITION AND PROCEED ONLY AFTER RECEIVING DIRECTION.
6. WHERE THE WORDS "OR EQUAL" OR WORDS OF SIMILAR INTENT FOLLOW A MATERIAL SPECIFICATION, THEY SHALL BE UNDERSTOOD TO
REQUIRE SIGNED APPROVAL OF ANY DEVIATION TO SAID SPECIFICATION PRIOR TO CONTRACTOR'S ORDERING OR INSTALLATION OF SUCH
PROPOSED EQUAL PRODUCT.
7. "FURNISH" MEANS SUPPLY ONLY, OTHERS TO INSTALL.
8. "INSTALL" MEANS INSTALL ITEMS FURNISHED BY OTHERS.
9. "PROVIDE" MEANS FURNISH AND INSTALL.
a 1
--'� at&t
5001 EXECUTIVE PARKWAY
SAN RAMON, CA 94583
fit O D U S
modus-corp.com
240 STOCKTON STREET, 3RD FLOOR
SAN FRANCISCO, CA 94108
borgesarch.com
1478 STONE POINT DRIVE, SUITE 350
ROSEVILLE CA 95661
916 782 7200 TEL
916 773 3037 FAX
3
06/12/19
100% CD Rev 2
2
02/22/18
100% CD Rev 1
1
12/04/17
100% CD Submittal
0
09/14/17
90% CD Submittal
REV
DATE
DESCRIPTION
SITE NUMBER:
SFOK02 017
SITE ADDRESS:
977 EL CAMINO REAL
BURLINGAME, CA 94010
STAMP
�ED ARc, ll
Ct
No. C11535 ;
J, �Pn 09-31),
41,
OF CA��F��
DRAWN BY: A.P.E. PROJECT NO.: T-16509-86
CHECK BY: B.P.M.
SHEET TITLE
GENERAL NOTES
SHEET NO.
GN=1
N
0
3
t
U
E
0
0
Ln
I
0
N
a
3
V)
0
a)
3
U
0
0
ut
I
2.7'f BACK OF POLE I
TO RIGHT—OF—WAY LINE
—Hf f0.7'0 BASE OF POLE
5.2'f FACE OF POLE
TO FACE OF CURB
GROUND EL: 37.9f
I — f1.0'0 BASE OF POLE
I
UTILITY POLE ELEVATION
CURB & GUTTER
V �l
38.5
\ CO,
S/
\
7't BACK OF POLE
RIGHT—OF—WAY LINE
SCALE: 1" = 5'
OVERHEAD
UTILITY LINES
5.2't FACE OF POLE
TO FACE OF CURB
STEEL LID
AT DRAIN INLET
�37.3 \
38. I
OVERHEAD
UTILITY LINES
w
J
O
it
J
H
D
Q
0
O
0
3:
0
w
Z Of
J C
H V)
0
J OfU
Z
J
0
o
Q
w
Z_
J
D
-H
w
U
Q
-
0)
N
It
-H
o
N
w
0
+
n
U
Z H
w
Lc�
N
O
r!J
+I N
J
0
w
aj N
+I
i�
0
N
EL CAMINO REAL
OVERHEAD /
UTILITY LINES /E
SITE
GPS POINT (NAD 83)
LAT: N 37'34'52.61"
LONG: W 122'21'40.41"
ELEV: 37.9f AMSL
(NAVD 88) AT GROUND
(E) WOOD UTILITY POLE
TOP POLE HT. 30.5't
7.
LLL
\ \
\I
V� LLLL
\
1.5'0 TREE \
HT. 45'f \ 38,8
\
8"0 TREE
r HT. 33't
I
\
\
TELEPHONE
i
MANHOLE
WOOD FENCE
\\
�, C3,
S
�\a�P
SS2
0 DO
4 F\
\
\
\ QUO
\
\
\
LANDS OF ANEZINOS
\
\
APN: 028-131-040
\
907 EL CAMINO REAL
\
\
\
\
HOUSE HT. 29't
\
\
2
ENLARGED
SITE PLAN
SCALE:
1 " = 5'
/
\
s SS
Soo \ APN: 029-011-020
F \ \
\ /
<cq�,. �\
GARAGE WALL / \ N.
�\ v, , - �
r \ (E) WOOD UTILITY POLE. . A 14 . S
TOP POLE HT. 30.5'f 'FIRE HYDRANT : • : �' '� S„
907 EL CAMINO REAL 0� >y 'j' • - \
bA
WOOD UTILITY POLE.'.**
\ I \ \ 7280
S00 \ W/ STREET LIGHT €
\
\
\ \ CABINET
LANDS OF ANEZINOS \ \ \ \
\ APN: 028-131-040 \ \
1500 FOREST VIEW AVENUE
\ APN: 028-131-050
1506 FOREST VIEW AVENUE / !'
100, low
Z-6,
S
24
MAGNETIC
0° NORTH
QUIET RIVER
Land Services Inc.
1 1/2 0 1
SCALE IN INCHES
MAGNETIC DECLINATION = 13030'
PER NOAA—NGDC
'0°
l SITE PLAN
SCALE: 1 " = 20'
SUFFICIENT SURVEY EVIDENCE WAS NOT RECOVERED TO ESTABLISH THE
POSITION OF THE BOUNDARY LINES SHOWN HEREON. THE BOUNDARY
REPRESENTED ON THIS MAP IS BASED ON COMPILED RECORD DATA AND
BEST FIT ONTO EXISTING IMPROVEMENTS. IT IS POSSIBLE FOR THE
LOCATION OF THE SUBJECT PROPERTY TO SHIFT FROM THE PLACEMENT
SHOWN HEREON WITH ADDITIONAL FIELD WORK AND RESEARCH.
THEREFORE, ANY SPATIAL REFERENCE MADE OR SHOWN BETWEEN THE
RELATIONSHIP OF THE BOUNDARY LINES AND EXISTING GROUND
FEATURES, EASEMENTS OR LEASE AREA SHOWN HEREON IS INTENDED TO
BE APPROXIMATE AND IS SUBJECT TO VERIFICATION BY RESOLVING THE
POSITION OF THE BOUNDARY LINES.
VICINITY MAP
NOT TO SCALE
0�
Fq�
�
o�Q
82 C ,<v
�O
0
SITE
BURLINGAME
SAN MATEO COUNTY
CALIFORNIA
S�P� I
SAN FRANCISCO BAY
TO
SAN MATEO
PROPERTY INFORMATION
Owner: CITY OF BURINGAME
Address: 501 PRIMROSE ROAD
BURLINGAME, CA 94010
Site: CRAN_RSFR—SFOK2-017
Address: 907 EL CAMINO REAL
BURLINGAME, CA 94010
Assessor's Parcel Number: PUBLIC RIGHT—OF—WAY
Height of BuildinglTower: 30.5't A.G.L. TOP OF (E) WOOD UTILITY POLE
Title Report:
NO TITLE REPORT FURNISHED. EXCEPTIONS TO THE TITLE AND RESERVATIONS
THEREFROM COULD NOT BE DETERMINED. BOUNDARY INFORMATION SHOWN IS
COMPILED FROM AVAILABLE RECORD DATA.
Legal Description:
PROPERTY SITUATED IN THE CITY OF BURLINGAME, COUNTY OF SAN MATEO,
STATE OF CALIFORNIA.
FEMA FLOOD ZONE DESIGNATION National Flood Insurance Program
County: SAN MATEO Effective Date: OCTOBER 16, 2012
Community —Panel Number: 06081 C-0153—E
The Flood Zone Designation for this site as plotted by scale is:
ZONE X (shaded) —Areas of 0.2% annual chance flood; areas of 1% annual
chance flood with average depths of less than 1 foot or with drainage areas
of less than one square mile; and area protected by levees from 1% annual
chance flood.
SURVEY DATA
NAD 83 Datum:
Lot: N 3734'52.61" Long: W 122'21'40.41"
Datum Base: NAD 83 Equipment Used: CHCX90D-0PUS Receiver
(See Note 2)
Site Ground Elevation: 37.9t AMSL (NAVD88) AT BASE OF SITE POLE
Basis of Elevations:
GLOBAL POSITIONING SYSTEM (GPS)
(SEE NOTE 2)
Basis of Bearings:
SPC83 CALIFORNIA COORDINATE SYSTEM, ZONE III AND BEST FIT WITH EXISTING
IMPROVEMENTS
Date of Field Survey: AUGUST 3, 2017
NOTES
1.) This is not a boundary survey. This is a specialized topographic map with property lines
and easements being a graphic depiction of various information gathered from preliminary
title reports, back—up documents of record, maps and available monuments found during the
field survey. No property monuments were set. No title research was performed by Quiet
River Land Services, Inc.
2.) The latitude, longitude and elevation shown hereon were derived from post —processed
L-1/L-2 data collected using Naystar Global Positioning System (GPS) and a CHCX90D—OPUS
Receiver. CHC Navigation specifications report decimeter level accuracy (horizontally) when
data is properly collected and processed. (Elevation = t3.0 feet.)
3.) Unless otherwise noted, no underground utility locating service company was contacted
prior to this map being prepared; therefore, there may be non —visible or obscure utilities
existing on the property not shown on this map — so CALL BEFORE YOU DIG.
4.) Any electronic digital media provided by Quiet River Land Services, Inc. to our client is a
courtesy and is not to be reproduced, distributed, sold, altered, revised, edited or amended
without the express written consent of an Officer of Quiet River Land Services, Inc. Further,
only the final stamped, signed and dated original "hard copy" version of our survey or map is
considered to be our legally recognized product.
SURVEYOR'S STATEMENT
I, the undersigned, a Registered Professional Land Surveyor licensed under the laws of the
State of California do hereby state that the information, measurements, easements, record
boundary lines, bearings and distances as shown hereon are based upon a field survey as
dated above and upon items of public record and data contained in a title report, as
referenced. Furthermore, the Latitude and Longitude coordinates are reported in NAD 83
Datum and are accurate to within ±15 feet horizontally, and the ground elevation, reported in
NAVD 1988 Datum, is within t3 feet vertically. The coordinate values and elevations are
within the 1—A Accuracy Code designation as listed in the A.S.A.C. Information Sheet 91:003
and are accurate to the best of my knowledge and belief.
SIGNATURE DATE
LEGEND
APN:
ASSESSOR'S PARCEL NUMBER
ASPHALT
CID
CONTROL POINT
CONCRETE
EL.
ELEVATION
FH
FIRE HYDRANT
®
CONTROL POINT
FND.
FOUND
O
FOUND MONUMENT
HT.
HEIGHT
MON.
MONUMENT
GPS POINT
(M—M)
MONUMENT TO MONUMENT
P 15.3
PARAPET/ROOF ELEVATIONS
P.O.B.
POINT OF BEGINNING
R 12.3
P.O.C.
POINT OF COMMENCEMENT
x 12.3
SPOT ELEVATION
PP
POWER POLE
19
TEMPORARY BENCHMARK
(TYP.)
TYPICAL
DATE:
AUGUST 11, 2017
DRAWN BY: MAS
FILE N0.: MDSC17111
REVISIONS
DATE
DESCRIPTION
INITIAL
8/8/17
100% COMPLETE
MAS
8/11 /17
CLIENT REDLINES
RO
�00
300
u7
J
L
LU rn
m
0_
U
O�
N
_
X
Q)
X
w
0
E
0
Of
06
QO
O
u7
�
/)
C/)
W
�
Y
N
0
00
r-
07 00
o Q
,i
c r7
Lin
CCU
N
� N
rn
a
EXISTING SITE CONDITIONS
I CRAN_RSFR_SFOK2_017 1
907 EL CAMINO REAL
BURLINGAME, CA 94010
C 1
OF 1 SHEET
0.2
Sf
\ LEGEND:
Sf
WATER: wS �
\ SANITARY SEWER: SS
Sf
\ STORM DRAIN: SD �
T, OVERHEAD UTILITY LINES:
(E) WOOD UTILITY POLE
(E) OVERHEA'D
UTILITY LINES TIP
Sf
Oy V \
� s
s
OyF
(E) GARAGE WALL
8' 4' 0 8' 16'
1 /8"=1 '-0"
1-7 OVERALL SITE PLAN
(E) TREES
— (E) TREES
\ (E) WOOD POLE I tS� (E) CURB AND GUTTER
W/ STREET LIGHT
`P.IWf
ss o � ws
� (E)OVERHEAD
UTILITY LIN S
ff
2
\ p q
\ i
\ (E) CURB AND GUTTER
0
S (P) ANTENNA MOUNTED ON TOP OF (E) UTILITY
POLE w/ (1) 4415 RADIO w/ PSU-08 & (1) 4426
RADIO W/ PSU-08 INSIDE (P) SOLAR SHIELD
\W MOUNTED ON (P) UTILITY POLE
Qy ( WOOD UltLITY POLE pN�
/ I )STEEL LID AT\
\ RAIN INLO
4�f
5
GO -
— (E) OVERHEAD
UTILITY LINES
�I -
S� S�
S� !'
O
�O
S�
Wf O
oNo�\
/ ws
(E) OVERHEAD
UTILITY LINES
(E) CURB AND GUTTER
(E) UTILITY POLE
(E) UTILITY POLE
(E) CABINET 0- _
(E) ELECTRICAL � ��G����
VAULT
Z _V v (E) FIRE HYDRANT
V (E) TEIPHONE MAANF40
OyF - 17 Ls
�- ♦ x \ L A-2 (E) TREES
V L
L Sf
` v
v
TIP
E TREES V Q \
(E) BUILDING V I
IV \ V (E)WOOD UTILITY POLE
APN: 0028-131-040 _ W/ STREET LIGHT\
V V _ — v TV f�
v
_ R s
V OyQ\ FT4�.S/e\ \ UTILITY R '�
ES \
(E) BUILDING
APN: 0028-131-040
��')G
NV \j
_ J i
V
i
T
(E) CAB14T
(E) BUILDING
APN: 0029-012-010 APN : 029-012-010
V
Sz . 7 �7
at&t
lztr�000'
5001 EXECUTIVE PARKWAY
SAN RAMON, CA 94583
modus-corp.com
240 STOCKTON STREET, 3RD FLOOR
SAN FRANCISCO, CA 94108
borgesarch.com
1478 STONE POINT DRIVE, SUITE 350
ROSEVILLE CA 95661
916 782 7200 TEL
916 773 3037 FAX
3
06/12/19
100% CD Rev 2
2
02/22/18
100% CD Rev 1
1
12/04/17
100% CD Submittal
0 09/14/17 90% CD Submittal
REV DATE DESCRIPTION
SITE NUMBER:
SFOK02 017
SITE ADDRESS:
977 EL CAMINO REAL
BURLINGAME, CA 94010
STAMP
D ARCy�T
sAM8 e
No. C11535
s� 09-30, �Q
qTF OF CAS\E0�
DRAWN BY: A.P.E. PROJECT NO.: T-16509-86
CHECK BY: B.P.M.
SHEET TITLE
SITE PLAN
SHEET NO.
1/8" = 1'-0"
2
SS O
SS 2
\ O
LEGEND:
WATER: WS WS
SANITARY SEWER: SS SS
STORM DRAIN: SD SD
OVERHEAD UTILITY LINES:
C 1. U L 4
1 /2"=1'-0"
(1) (P) 4415 RADIO w/
PSU-08 & (1) (P) 4426
RADIO w/ PSU-08 INSIDE
(P) SOLAR SHIELD
ilo
NOBSTRUCTED
LIMBING SPACE
RRUS MOUNTING DETAIL
V = 1'-0"
(P) ELECTRIC LOAD CENTER
GTE: 30"X30"
NOBSTRUCTED
(P) UNISTRUT P1000 OR EQ.
(P) 3/8" "C" ALUMINUM
CHANNEL, 8" WIDE
12 ----- (P) 2" SQ. STEEL TUBE
K
(P) 3" COAX CONDUIT
P)1 1/2" CONDUIT
(P) UTILITY POLE
5/8" ANTI -SPLIT
GALVANIZED
RU-BOLT (TYP)
(P) UNISTRUT P1000 OR EQ.
(P) 3/8" "C" ALUMINUM
CHANNEL, 8" WIDE
(P) 2" SQ. STEEL TUBE
T' (P) 1 1/2" CONDUIT
�\ 3
\
\\ (P) UTILITY POLE
(P) 5/8" ANTI -SPLIT
GALVANIZED
THRU-BOLT (TYP)
LOAD CENTER MOUNTING DETAIL
1" = 1'-0"
N
(P) 3" COAX RISER
(P) 1 1/2" AC POWER RIS
(P) (1) AA15 RADIO w/ PSU-08 P. (1) 4426 R.......
W/ PSU-08 INSIDE (P) SOLAR SHIELD MOUNTED
ON (E) UTILITY POLE
1' 0.5' 0 1' 2'
/M onnAnrnni E: METER
P1000 OR EQ.
JMINUM
VIDE
EEL TUBE
POWER METER MOUNTING DETAIL
1" = 1'-0"
(P) ANTENNA MOUNTED ON
TOP OF (P) UTILITY POLE
"' CONDUIT
(P) UTILITY POLE
5/8" ANTI -SPLIT
GALVANIZED
IRU-BOLT (TYP)
� at&t
5001 EXECUTIVE PARKWAY
SAN RAMON, CA 94583
modus-corp.com
240 STOCKTON STREET, 3RD FLOOR
SAN FRANCISCO, CA 94108
borgesarch.com
1478 STONE POINT DRIVE, SUITE 350
ROSEVILLE CA 95661
916 782 7200 TEL
916 773 3037 FAX
3
06/12/19
100% CD Rev 2
2
02/22/18
100% CD Rev 1
1
12/04/17
100% CD Submittal
0
09/14/17
90% CD Submittal
REV
DATE
DESCRIPTION
SITE NUMBER:
SFOK02 017
SITE ADDRESS:
977 EL CAMINO REAL
BURLINGAME, CA 94010
STAMP
D ARclil
SA
No. C11535 ;
�P
J ? 09-3C3 �Q
OF CAS\E0j
DRAWN BY: A.P.E. PROJECT NO.: T-16509-86
CHECK BY: B.P.M.
SHEET TITLE
ENLARGED SITE
PLAN & ANTENNA
PLAN
SHEET NO.
ENLARGED SITE PLAN
1/2" = 1'-0"
ENLARGED ANTENNA PLAN
1" = 1'-0"
A=2
NOTES:
1. PAINT RRU SOLAR SHIELD, MOUNTING COMPONENTS & CABLE SWEEP TO MATCH (E) POLE.
A 30'-6"
TOP OF (P) AT&T ANTENNA
RAID CENTER OF (P) AT&T ANTENNA
TOP OF (P) COAX RISER AND (P)
WOOD POLE
A 29'-0"ly _
TOP OF (E) CROSSARM
(P) RF WARNING SIGN -
MINIMUM APPROACH
DISTANCE = 6-0"
IV BOTTOM OF (E) BRACE
A 23'-6"" _ _
ly TOP OF (E) UTILITY LINE AND ANCHOR POINT
21 '-7" _ j
TOP OF (E)ELECTRICAL DROP —LINE
20'-7"
TOP OF (E) CROSS ARM
TOP OF (E) UTILITY LINE AND ANCHOR POINT
d% 0'-0°IV _
GRADE LEVEL
(P) 4426 RADIO w/
PSU-08 INSIDE (P)
SOLAR SHROUD
(P) SOLAR SHIELD TO HAVE SLATS
ON BOTH SIDES, TOP AND
BOTTOM TO REMAIN OPEN
(P) 4415 RADIO w/ PSU-08, (P) (2)
TWIN DIPLEXERS, AND (P)
GROUND BAR INSIDE (P) SOLAR
SHROUD
(P) (2) TWIN DIPLEXERS
(P) GROUND BAR
(P) SMARTPOLE METER
(P) ELECTRIC LOAD CENTER
(P) ANTENNA MOUNTED ON TOP
OF (P) WOOD POLE
1lJ
(P) 3" COAX RISER
(P) 6'-0" POWER SAFETY
ZONE PER GO 95
(P) 2'-0" COMMUNICATIONS
SAFETY ZONE PER G095
_ _ l
I
TOP OF (P) SOLAR SHIELD
L - I
I
F I
L
I-
10'-2"
- BOTTOM OF (P) SOLAR SHIELD
I_
9'-2" Ilk
- TOP OF (P) SMARTPOLE METER
I-
- 8,-7"
BOTTOM OF (P) SMARTPOLE METER
- 8' 1 '
_
9 TOP OF (P) LOAD CENTER
A-4 7- 0"
JBOTTOM
OF (P) LOAD CENT
(P) 2" FIBER RISER FROM AT&T TO (P) FIBER
DEMARK ENCLOSURE NEXT TO LOAD
CENTER ON POLE
(P) AT&T FIBER P.O.C.
at&t
5001 EXECUTIVE PARKWAY
SAN RAMON, CA 94583
modus-corp.com
240 STOCKTON STREET, 3RD FLOOR
SAN FRANCISCO, CA 94108
borgesarch.com
1478 STONE POINT DRIVE, SUITE 350
ROSEVILLE CA 95661
916 782 7200 TEL
916 773 3037 FAX
3
06/12/19
100% CD Rev 2
2
02/22/18
100% CD Rev 1
1
12/04/17
100% CD Submittal
0
09/14/17
90% CD Submittal
REV
DATE
DESCRIPTION
SITE NUMBER:
SFOK02 017
SITE ADDRESS:
977 EL CAMINO REAL
BURLINGAME, CA 94010
STAMP
-�,D A RCyiT
���� S A
No. C11535 ;
�P
09-30)
OF CA\\E0j
DRAWN BY: A.P.E. PROJECT NO.: T-16509-86
CHECK BY: B.P.M.
SHEET TITLE
ELEVATIONS
SHEET NO.
EXISTING NORTH ELEVATION
1 /2" = 1'-0''
PROPOSED NORTH ELEVATION
1 /2" = 1'-0"
A=3
6
NOTE:
ALL CABINETS MOUNTED TO UTILITY POLE
lo 6" SHALL HAVE A MINIMUM TOP & BOTTOM
CLEARANCE OF 7".
�IIIII
I!iy'I,I �I
=
NEW 2" SQ. STL. TUBE
STEEL
NEW 3/8" C ALUMINUM CHANNEL, 6"
WIDE MIN.
1
NEW UNISTRUT P 1000
OR EQUAL (TYP.)- HORIZONTAL -
LENGTH AS REQUIRED PER
CABINET
NEW 1/2"0 MOUNTING
BOLT(CONTRACTOR
TO VERIFY WITH
1 CABINET MFG. SPEC.)
5/8" 0 ANTI - SPLIT
GALVANIZED THRU - BOLT
ELEVATION VEW (TYP.)
EQUIPMENT MOUNTING DETAIL
3/4" = 1'-0"
C9191
PG&E SMARTPOLE METER DIMENSIONS:
DIAMETER: +/- 4.63"
HEIGHT: +/- 7.17"
WEIGHT: +/- 12 LBS
3 POLE, 3 WIRE
_OCKING
RECEPTACLE
NEMA 3R
ENCLOSURE U
BOX
4.18"
—�' NOTES:
1. PG&E CODE #M241490 & #M241572
2. PG&E TO PERFORM RF SIGNAL TEST.
3. INSTALL IN STRICT ACCODANCE WITH PG&E UTILITY
BULLETIN FOR SMARTPOLE METER SERVICE
SMART POLE METER DETAIL
3" = 1'-0"
(P) WAGON WHEEL FOR
13" DIA RADOME
0
(2) (P) 5/8" DIA. THRU BOLTS
(P) 6"X6"X6"X1/4"
TUBE STEEL CAP
NEW 5-3/4" SQUARE
WOOD EXTENSION FOR
V
(E) WOOD UTILITY POLE
CANISTER ANTENNA MOUNTING DETAIL
1' = 1'-0"
(E) WOOD UTILITY POLE
(P) 1/2" DIA. 3" ANTI -SPLIT
LAG SCREW
(P) 2-HOLE GALVANIZED
CONDUIT STRAP
CONDUIT STRAP DETAIL
1 1/2" = 1'-0"
NEW 3/8" C ALUMINUM
CHANNEL, 10" WIDE
NEW 2" SQ. STEEL TUBE OR —
ROUND STOCK. 6" MIN. TYP.
OF 4
(E)1 1/2" CONDUIT
EXISTING WOODEN
UTILITY POLE
5/8" 0 ANTI - SPLIT
GALVANIZED THRU BOLT
(TYP.)
(N) 3" COAX CONDUIT
NEW UNISTRUT P1000
OR EQUAL (TYP.)- HORIZONTAL
- LENGTH AS REQUIRED PER
CABINET
PLAN VIEW
(P) 3" COAX RISER
4" MIN
CLEARANCE
PER GO 95
} Z �
W Z � W
Lu Of
W m J ~ 5
> Q m a Lu
6" MIN
NEW 1/2"0 MOUNTING
BOLT PER CABINET
BOLTING PATTERN
NOTE: ELEC LOAD CENTER MAKE AND MODEL:
RF SHUTDOWN SIGNAGE TO BE ON THE MANUFACTURER: SQUARE D
INSIDE AND OUTSIDE OF THE LOAD CENTER MODEL: Q0612L100RB
DIMENSIONS, HxWxD.in: 12.64" x8.9" x 4.27"
WEIGHT: 9.7 Ibs
MOUNTING
BRACKET FOR (P)
EQUIPMENT
8.9"
TOP
v
ELEC LOAD CENTER Qol
4.27"
FRONT SIDE
ELEC LOAD CENTER DETAIL
8 3/8" 6.
ao
TWIN DIPLEXER MAKE AND MODEL:
MANUFACTURER:COMMSCOPE
MODEL: CBC1923T-4310-E11 F13P06
DIMENSIONS, HxWxD: 8.3" x 4.6" x 1.8"
WEIGHT: 5.5 Ibs PER UNIT
TOP: (2) TWIN DIPLEXERS
1 3/4"
FRONT:
TWIN DIPLEXER DETAIL
3" = 1'-0"
(P) 2'-0" TELECOMMUNICATIONS
SAFETY ZONE AS PER G095
L - J
(P) 4426 RADIO INSIDE J
PROPOSED SOLAR
SHIELD w/ PSU-08
(P) 4415 RADIO INSIDE I
PROPOSED SOLAR I
SHIELD w/ PSU-08
(P) (2) TWIN DIPLEXERS
(P) GROUND BAR
L - J
1'-3"
(P) SMARTPOLE METER
(P) ELECTRIC LOAD CENTER
(P) PLACE SHUT DOWN PROTOCOLS
ON THE INSIDE COVER OF THE LOAD
CENTER TO BE PROVIDED BY AT&T
A
M 0
i�
A
co
ANTENNA EQUIPMENT FRONT ELEVATION
3/4" = 1'-0"
NOTE
NEW BRACKET ASSEMBLY
TO BE PROVIDED BY UTILITY
COMPANY
5/8'0 X10" BOLT AND
LOCKNUT (SUPPLIED)
LOWER BRACKET .....................................................
STEP
4
ER (FOR
R
13/16" HOLES FO
3/4" BOLTS
BRACKET ADAPT
POLE TOP DIAMETERS LESS
THAN 8")
EXISTING POLE
DETAIL A
BRACKET ASSEMBLY
DETAIL B
WOOD EXTENSION
ASSEMBLY
WOOD POLE EXTENSION
3/4" = 1'-0"
UPPER BRACKET
STEP
II o I� 12"
5"
7-112"
n
EXISTING POLE
EXTENSION BAYONET 5
3/4" SQUARE PRESSURE
TREATED DOUGLAS FIR
BRACKET ASSEMBLY
(SEE DETAIL A)
ANTI- SPLIT BOLT
NOTE:
SIGN BACKGROUND COLOR TO MATCH (E) POLE
ALL TEXT AND SYMBOLS TO BE WHITE
MINIMUM APPROACH DISTANCE — 6'
NOTICE SIGNAGE
CANISTER
ANTENNA
(P) (4) 1/2"
SUPERFLEX COAX
T
0 yrt
CXAX
COAX
I � COA
+� COAX n
0 0 0 0
(P) RET CABLE- A x
I
Q Q
I I I I (P) (4) 1/2''
SUPERFLEX COAX
WIRE DIAGRAM
r;
N
ANTENNA = CANISTER
WEIGHT = 33.1 LBS
CONNECTOR = 10 X 4.3-10 DIN (FEMALE) / BOTTOM
DIMENSIONS = 9.45"(DIA.) X 23.63"
CANISTER ANTENNA
1 1/2" = 1'-0"
NOTE:
INSIDE AND OUTSIDE PANEL DOOR SHOWING
SHUT —DOWN PROTOCOL ON 3"X4" LABEL
SHUT DOWN PROTOCOL SIGNAGE
= I
S; —wow—
t'"
5001 EXECUTIVE PARKWAY
SAN RAMON, CA 94583
a t &t
modus-corp.com
240 STOCKTON STREET, 3RD FLOOR
SAN FRANCISCO, CA 94108
borgesarch.com
1478 STONE POINT DRIVE, SUITE 350
ROSEVILLE CA 95661
916 782 7200 TEL
916 773 3037 FAX
3
06/12/19
100% CD Rev 2
2
02/22/18
100% CD Rev 1
1
12/04/17
100% CD Submittal
0
09/14/17
90% CD Submittal
REV
DATE
DESCRIPTION
SITE NUMBER:
SFOK02 017
SITE ADDRESS:
977 EL CAMINO REAL
BURLINGAME, CA 94010
STAMP
D ARCy�T
SA�BU
cFA
* m No. C11535 ;
JJ9�Pn 09-3�
tF OF C A�
DRAWN BY: A.P.E. PROJECT NO.: T-16509-86
CHECK BY: B.P.M.
SHEET TITLE
DETAILS
SHEET NO.
A■
401
IY
J
U
CD
ERICSSON RRUS 4426 REMOTE RADIO UNIT
COLOR: WHITE
DIMENSIONS: 14.9" TALL X 13.19" WIDE X 5.8" DEEP (INCLUDING SUNSHIELD)
WIEGHT: +/- 48.5 LBS. (EXCLUDING MOUNTING HARDWARE)
^n1 I no
RRUS WITH SUNSHIELD
a;
13.19
FRONT VIEW
P 1000 U
PS
SUNSHIE
I Vh' VItVV
RAfll 1KITIAI!' r'LJAAIAIM
SIDE VIEW
J
U
co
J
U
N
ERICSSON RRUS-4415 REMOTE RADIO UNIT
COLOR: WHITE
DIMENSIONS: 14.96" TALL X 13.19" WIDE X 5.39" DEEP (INCLUDING SUNSHIELD)
VOLUME: 0.6155 CU. FT.
WEIGHT: +/- 44.0 LBS. (EXCLUDING MOUNTING HARDWARE)
MFR'S STANDARD N
RRUS WITH SUNSH
13 19"
FRONT VIEW
MOUNTING ^^'
MFR'S STA
MOUNTINC
BRACKET
SUNSHIEL
TOP VIEW
® j
5001 EXECUTIVE PARKWAY
SAN RAMON, CA 94583
at&t
IIl'1 Q D U S
modus-corp.com
240 STOCKTON STREET, 3RD FLOOR
SAN FRANCISCO, CA 94108
borgesarch.com
1478 STONE POINT DRIVE, SUITE 350
ROSEVILLE CA 95661
916 782 7200 TEL
916 773 3037 FAX
3
06/12/19
100% CD Rev 2
2
02/22/18
100% CD Rev 1
1
12/04/17
100% CD Submittal
0
09/14/17
90% CD Submittal
REV DATE DESCRIPTION
SITE NUMBER:
SFOK02 017
SITE ADDRESS:
977 EL CAMINO REAL
BURLINGAME, CA 94010
STAMP
SED A RCy�T
�pSAM9p `°cr
* m No. C11535
qTF OF CAS\F��
DRAWN BY: A.P.E. PROJECT NO.: T-16509-86
CHECK BY: B.P.M.
SHEET TITLE
DETAILS
SHEET NO.
RRUS 4426
1 1 /2" = V-0"
RRUS 4415
1 1/2" = 1'-0"
A=4m2
ELECTRICAL NOTES
0
GENERAL REQUIREMENTS:
1. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE LATEST RULES AND
REGULATIONS OF THE NATIONAL ELECTRICAL CODE AND ALL STATE AND LOCAL CODES.
NOTHING IN THESE PLANS OR SPECIFICATIONS SHALL BE CONSTRUED AS TO PERMIT
WORK NOT CONFORMING TO THE MOST STRINGENT OF THESE CODES. SHOULD
CHANGES BE NECESSARY IN THE DRAWINGS OR SPECIFICATIONS TO MAKE THE WORK
COMPLY WITH THESE REQUIREMENTS, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE
ARCHITECT IN WRITING AND CEASE WORK ON PARTS OF THE CONTRACT WHICH ARE
AFFECTED.
2. THE CONTRACTOR SHALL MAKE A SITE VISIT PRIOR TO BIDDING AND CONSTRUCTION TO
VERIFY ALL EXISTING CONDITIONS AND SHALL NOTIFY ARCHITECT IMMEDIATELY UPON
DISCOVERY OF ANY DISCREPANCIES. THE CONTRACTOR ASSUMES ALL LIABILITY FOR
FAILURE TO COMPLY WITH THIS PROVISION.
3. THE EXTENT OF THE WORK IS INDICATED BY THE DRAWINGS, SCHEDULES, AND
SPECIFICATIONS AND IS SUBJECT TO THE TERMS AND CONDITIONS OF THE CONTRACT.
THE WORK SHALL CONSIST OF FURNISHING ALL LABOR, EQUIPMENT, MATERIALS, AND
SUPPLIES NECESSARY FOR A COMPLETE AND OPERATIONAL ELECTRICAL SYSTEM. THE
WORK SHALL ALSO INCLUDE THE COMPLETION OF ALL ELECTRICAL WORK NOT
MENTIONED OR SHOWN WHICH IS NECESSARY FOR SUCCESSFUL OPERATION OF ALL
SYSTEMS.
4. THE CONTRACTOR SHALL PREPARE A BID FOR A COMPLETE AND OPERATIONAL SYSTEM,
WHICH INCLUDES THE COST FOR MATERIAL AND LABOR.
5. WORKMANSHIP AND NEAT APPEARANCE SHALL BE AS IMPORTANT AS THE OPERATION.
DEFECTIVE OR DAMAGED MATERIALS SHALL BE REPLACED OR REPAIRED PRIOR TO FINAL
ACCEPTANCE IN A MANNER ACCEPTABLE TO OWNER AND ENGINEER.
6. COMPLETE THE ENTIRE INSTALLATION AS SOON AS THE PROGRESS OF THE WORK WILL
PERMIT. ARRANGE ANY OUTAGE OF SERVICE WITH THE OWNER AND BUILDING
MANAGER IN ADVANCE. MINIMIZE DOWNTIME ON THE BUILDING ELECTRICAL SYSTEM.
7. THE ENTIRE ELECTRICAL SYSTEM INSTALLED UNDER THIS CONTRACT SHALL BE DELIVERED IN
PROPER WORKING ORDER. REPLACE, WITHOUT ADDITIONAL COST TO THE OWNER, ANY
DEFECTIVE MATERIAL AND EQUIPMENT WITHIN ONE YEAR FROM THE DATE OF FINAL
ACCEPTANCE.
8. ANY ERROR, OMISSION OR DESIGN DESCREPANCY ON THE DRWINGS SHALL BE BROUGHT
TO THE ATTENTION OF THE ENGINEER FOR CLARIFICATION OR CORRECTION BEFORE
CONSTRUCTION.
9. "PROVIDE" INDICATES THAT ALL ITEMS ARE TO BE FURNISHED, INSTALLED AND
CONNECTED IN PLACE.
10. CONTRACTOR SHALL SECURE ALL NECESSARY BUILDING PERMITS AND PAY ALL
REQUIRED FEES.
EQUIPMENT LOCATION:
1. THE DRAWINGS INDICATE DIAGRAMMATICALLY THE DESIRED LOCATIONS OR
ARRANGEMENTS OF CONDUIT RUNS, OUTLETS, EQUIPMENT, ETC., AND ARE TO BE
FOLLOWED AS CLOSELY AS POSSIBLE. PROPER JUDGEMENT MUST BE EXERCISED IN
EXECUTING THE WORK SO AS TO SECURE THE BEST POSSIBLE INSTALLATION IN THE
AVAILABLE SPACE LIMITATIONS OR INTERFERENCE OF STRUCTURE CONDITIONS
ENCOUNTERED.
2. IN THE EVENT CHANGES IN THE INDICATED LOCATIONS OR ARRANGEMENTS ARE
NECESSARY, DUE TO FIELD CONDITIONS IN THE BUILDING CONSTRUCTION OR
REARRANGEMENT OF FURNISHINGS OR EQUIPMENT, SUCH CHANGES SHALL BE MADE
WITHOUT COST, PROVIDING THE CHANGE IS ORDERED BEFORE THE CONDUIT RUNS, ETC.,
AND WORK DIRECTLY CONNECTED TO THE SAME IS INSTALLED AND NO EXTRA MATERIALS
ARE REQUIRED.
3. LIGHTING FIXTURES ARE SHOWN IN THEIR APPROXIMATE LOCATIONS ONLY. COORDINATE
THE FIXTURE LOCATION WITH MECHANICAL EQUIPMENT TO AVOID INTERFERENCE.
4. COORDINATE THE WORK OF THIS SECTION WITH THAT OF ALL OTHER TRADES, WHERE
CONFLICTS OCCUR, CONSULT WITH THE RESPECTIVE CONTRACTOR AND COME TO
AGREEMENT AS TO CHANGES NECESSARY, OBTAIN WRITTEN ACCEPTANCE FROM
ENGINEER FOR THE PROPOSED CHANGES BEFORE PROCEEDING.
SHOP DRAWINGS:
1. N/A UNLESS NOTED OTHERWISE.
SUBSTITUTIONS:
1. NO SUBSTITUTIONS ARE ALLOWED
TESTS:
1. BEFORE FINAL ACCEPTANCE OF WORK, THE CONTRACTOR SHALL INSURE THAT ALL
EQUIPMENT, SYSTEMS, FIXTURES, ETC., ARE WORKING SATISFACTORILY AND TO THE INTENT
OF THE DRAWINGS.
PERMITS:
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR TAKING OUT AND PAYING FOR ALL
REQUIRED PERMITS, INSPECTION AND EXAMINATION WITHOUT ADDITIONAL EXPENSE TO
THE OWNER.
1. THE CONTRACTOR SHALL PROVIDE A COMPLETE, AND APPROVED GROUNDING SYSTEM
INCLUDING ELECTRODES, ELECTRODE CONDUCTOR, BONDING CONDUCTORS, AND
EQUIPMENT CONDUCTORS AS REQUIRED BY ARTICLE 250 OF THE NATIONAL ELECTRICAL
CODE.
2. CONDUITS CONNECTED TO EQUIPMENT AND DEVICES SHALL BE METALICALY JOINED
TOGETHER TO PROVIDE EFFECTIVE ELECTRICAL CONTINUITY.
3. FEEDERS AND BRANCH CIRCUIT WIRING INSTALLED IN A NONMETALLIC CONDUIT SHALL
INCLUDE A CODE SIZED GROUNDING CONDUCTOR HAVING GREEN INSULATION. THE
GROUND CONDUCTOR SHALL BE PROPERLY CONNECTED AT BOTH ENDS TO MAINTAIN
ELECTRICAL CONTINUITY.
4. REFER TO GROUND BUS DETAILS. PROVIDE NEW GROUND SYSTEM COMPLETE WITH
CONDUCTORS, GROUND ROD AND DESCRIBED TERMINATIONS.
5. ALL GROUNDING CONDUCTORS SHALL BE SOLID TINNED COPPER AND ANNEALED #2
UNLESS NOTED OTHERWISE.
6. ALL NON -DIRECT BURIED TELEPHONE EQUIPMENT GROUND CONDUCTORS SHALL BE #2
STRANDED THHN (GREEN) INSULATION.
7. ALL GROUND CONNECTIONS SHALL BE MADE WITH "HYGROUND" COMPRESSION SYSTEM
BURNDY CONNECTORS EXCEPT WHERE NOTED OTHERWISE.
8. PAINT AT ALL GROUND CONNECTIONS SHALL BE REMOVED.
9. GROUNDING SYSTEM RESISTANCE SHALL NOT EXCEED 5 OHMS. IF THE RESISTANCE VALUE
IS EXCEEDED, NOTIFY THE OWNER FOR FUTURE INSTRUCTION ON METHODS FOR
REDUCING THE RESISTANCE VALUE. SUBMIT TEST REPORTS AND FURNISH TO SMART SMR
ONE COMPLETE SET OF PRINTS SHOWING "INSTALLED WORK".
UTILITY SERVICE:
1. TELEPHONE AND ELECTRICAL METERING FACILITIES SHALL CONFORM TO THE
REQUIREMENTS OF THE SERVING UTILITY COMPANIES. CONTRACTOR SHALL VERIFY
SERVICE LOCATIONS AND REQUIREMENTS. SERVICE INFORMATION WILL BE FURNISHED BY
THE SERVING UTILITIES.
2. CONFORM TO ALL REQUIREMENTS OF THE SERVING UTILITY COMPANIES.
PRODUCTS:
1. ALL MATERIALS SHALL BE NEW, CONFORMING WITH NEC, ANSI, NEMA, AND THEY SHALL
BE U.L. LISTED AND LABELED.
2. CONDUIT:
A) RIGID CONDUIT SHALL BE U.L. LABEL GALVANIZED ZINC COATED WITH ZINC
INTERIOR AND SHALL BE USED WHEN INSTALLED IN OR UNDER CONCRETE SLABS,
IN CONTACT WITH THE EARTH, UNDER PUBLIC ROADWAYS, IN MASONRY WALLS
OR EXPOSED ON BUILDING EXTERIOR, RIGID CONDUIT IN CONTACT WITH EARTH
SHALL BE 1/2 LAPPED WRAPPED WITH HUNTS WRAP PROCESS NO. 3.
B) ELECTRICAL METALLIC TUBING SHALL U.L. LABEL, FITTINGS SHALL BE
COMPRESSION TYPE. EMT SHALL BE USED ONLY FOR INTERIOR RUNS.
C) FLEXIBLE METALLIC CONDUIT SHALL HAVE U.L. LISTED LABEL AND MAY BE USED
WHERE PERMITTED BY CODE. FITTINGS SHALL BE "JAKE" OR "SQUEEZE" TYPE. SEAL
TIGHT FLEXIBLE CONDUIT. ALL CONDUIT EXCESS OF SIX FEET IN LENGTH SHALL
HAVE FULL SIZE GROUND WIRE.
D) CONDUIT RUNS MAY BE SURFACE MOUNTED IN CEILING OR WALLS UNLESS
INDICATED OTHERWISE. CONDUIT INDICATED SHALL RUN PARALLEL OR AT RIGHT
ANGLES TO CEILING, FLOOR OR BEAMS. VERIFY EXACT ROUTING OF ALL
EXPOSED CONDUIT WITH ARCHITECT PRIOR TO INSTALLING.
E) ALL UNDERGROUND CONDUITS SHALL BE PVC SCHEDULE 40 (UNLEES NOTED
OTHERWISE) AT A MINIMUM DEPTH OF 24" BELOW GRADE
F) ALL CONDUIT ONLY (C.O.) SHALL HAVE PULL ROPE.
G) CONDUITS RUN ON ROOFS SHALL BE INSTALLED ON 4x4 REDWOOD SLEEPERS,
C-0" ON CENTER, SET IN NON -HARDENING MASTIC.
3. ALL WIRE AND CABLE SHALL BE COPPER, 600 VOLT, # 12 AWG MINIMUM UNLESS
SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. CONDUCTORS # 10 AWG AND
SMALLER SHALL BE SOLID. CONDUCTORS #8 AWG AND LARGER SHALL BE STRANDED.
TYPE THHN INSULATION USED UNLESS CONDUCTORS INSTALLED IN CONDUIT EXPOSED TO
WEATHER, IN WHICH CASE TYPE THWN INSULATION SHALL BE USED.
4. PROVIDE GALVANIZED COATED STEEL BOXES AND ACCESSORIES SIZED PER CODE TO
ACCOMMODATE ALL DEVICES AND WIRING.
5. DUPLEX RECEPTACLES SHALL BE SPECIFICATION GRADE WITH WHITE FINISH (UNLESS
NOTED BY ENGINEER), 20 AMP, 125 VOLT, THREE WIRE GROUNDING TYPE, NEMA 5-20R.
MOUNT RECEPTACLE AT +12" ABOVE FINISHED FLOOR UNLESS OTHERWISE INDICATED ON
DRAWINGS OR IN DETAILS. WEATHERPROOF RECEPTACLES SHALL BE GROUND FAULT
INTERRUPTER TYPE WITH SIERRA #WPD-8 LIFT COVERPLATES.
6. TOGGLE SWITCHES SHALL BE 20 AMP, 120 VOLT AC, SPECIFICATION GRADE WHITE
(UNLESS NOTED OTHERWISE) FINISH. MOUNT SWITCHES AT +48" ABOVE FINISHED FLOOR.
7. PANELBOARDS SHALL BE DEAD FRONT SAFETY TYPE WITH ANTI -BURN SOLDERLESS
COMPRESSION APPROVED FOR COPPER CONDUCTORS, COPPER BUS BARS, FULL SIZED
NEUTRAL BUS, GROUND BUS AND EQUIPPED WITH QUICK -MAKE QUICK -BREAK BOLT -IN
TYPE THERMAL MAGNETIC CIRCUIT BREAKERS. MOUNT TOP OF THE PANELBOARDS AT
6'-3" ABOVE FINISHED FLOOR. PROVIDE TYPE WRITTEN CIRCUIT DIRECTORY.
8. ALL CIRCUIT BREAKERS, MAGNETIC STARTERS AND OTHER ELECTRICAL EQUIPMENT SHALL
HAVE AN INTERRUPTING RATING NOT LESS THAN MAXIMUM SHORT CIRCUIT CURRENT TO
WHICH THEY MAY BE SUBJECTED.
9. GROUND RODS SHALL BE COPPER CLAD STEEL, 5/8" ROUND AND 10' LONG.
COPPERWELD OR APPROVED EQUAL.
INSTALLATION:
1. PROVIDE SUPPORTING DEVICES FOR ALL ELECTRICAL EQUIPMENT, FIXTURES, BOXES,
PANEL, ETC., SUPPORT LUMINARIES FROM UNDERSIDE OF STRUCTURAL CEILING,
EQUIPMENT SHALL BE BRACED TO WITHSTAND HORIZONTAL FORCES IN ACCORDANCE
WITH STATE AND LOCAL CODE REQUIREMENTS. PROVIDE PRIOR ALIGNMENT AND
LEVELING OF ALL DEVICES AND FIXTURES.
2. CUTTING, PATCHING, CHASES, OPENINGS: PROVIDE LAYOUT IN ADVANCE TO ELIMINATE
UNNECESSARY CUTTING OR DRILLING OF WALLS, FLOORS CEILINGS, AND ROOFS. ANY
DAMAGE TO BUILDING STRUCTURE OR EQUIPMENT SHALL BE REPAIRED BY THE
CONTRACTOR. OBTAIN PERMISSION FROM THE ENGINEER BEFORE CORING.
3. IN DRILLING HOLES INTO CONCRETE WHETHER FOR FASTENING OR ANCHORING
PURPOSES, OR PENETRATIONS THROUGH THE FLOOR FOR CONDUIT RUNS, PIPE RUNS,
ETC., IT MUST BE CLEARLY UNDERSTOOD THAT TENDONS AND/OR REINFORCING STEEL
WILL NOT BE DRILLED INTO, CUT OR DAMAED UNDER THE CIRCUMSTANCES.
4. LOCATION OF TENDONS AND/OR REINFORCING STEEL ARE NOT DEFINITELY KNOWN AND
THEREFORE, MUST BE SEARCHED FOR BY APPROPRIATE METHODS AND EQUIPMENT VIA
X-RAY OR OTHER DEVICES THAT CAN ACCURATELY LOCATE THE REINFORCING AND/OR
STEEL TENDONS.
5. PENETRATIONS IN FIRE RATED WALLS SHALL BE FIRE STOPPED IN ACCORDANCE WITH THE
REQUIREMENTS OF THE C.B.C.
PROJECT CLOSEOUT:
1. UPON COMPLETION OF WORK, CONDUCT CONTINUITY, SHORT CIRCUIT, AND FALL
POTENTIAL GROUNDING TESTS FOR APPROVAL. SUBMIT TEST REPORTS TO PROJECT
MANAGER. CLEAN PREMISES OF ALLS DEBRIS RESULTING FROM WORK AND LEAVE WORK
IN A COMPLETE AND UNDAMAGED CONDITION.
2. PROVIDE PROJECT MANAGER WITH ONE SET OF COMPLETE ELECTRICAL "AS INSTALLED"
DRAWINGS AT THE COMPLETION OF THE JOB, SHOWING ACTUAL DIMENSIONS,
ROUTINGS AND CIRCUITS.
3. ALL BROCHURES, OPERATING MANUALS, CATALOG, SHOP DRAWINGS, ETC., SHALL BE
TURNED OVER TO OWNER AT JOB COMPLETION.
GROUNDING NOTES:
1. ALL DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL GROUNDING INSTALLATION
REQUIREMENTS AND CONSTRUCTION ACCORDING TO SITE CONDITIONS.
2. ALL GROUNDING CONDUCTORS: #2 AWG SOLID BARE TINNED COPPER WIRE UNLESS
OTHERWISE NOTED.
3. GROUND BAR LOCATED IN BASE OF EQUIPMENT WILL BE PROVIDED, FURNISHED AND
INSTALLED BY THE VENDOR.
4. ALL BELOW GRADE CONNECTIONS: EXOTHERMIC WELD TYPE, ABOVE GRADE
CONNECTIONS: EXOTHERMIC WELD TYPE.
5. GROUND RING SHALL BE LOCATED A MINIMUM OF 24" BELOW GRADE OR 6" MINIMUM
BELOW THE FROST LINE.
6. INSTALL GROUND CONDUCTORS AND GROUND ROD MINIMUM OF 1'-0" FROM
EQUIPMENT CONCRETE SLAB, SPREAD FOOTING, OR FENCE.
7. EXOTHERMIC WELD GROUND CONNECTION TO FENCE POST: TREAT WITH A COLD
GALVANIZED SPRAY.
8. GROUND BARS:
A) EQUIPMENT GROUND BUS BAR (EGB) LOCATED AT THE BOTTOM OF ANTENNA
POLE/MAST FOR MAKING GROUNDING JUMPER CONNECTIONS TO COAX
FEEDER CABLES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL
CONTRACTOR. JUMPERS (FURNISHED BY OWNERS) SHALL BE INSTALLED AND
CONNECTED BY ELECTRICAL CONTRACTOR.
9. ALL GROUNDING INSTALLATIONS AND CONNECTIONS SHALL BE MADE BY ELECTRICAL
CONTRACTOR.
10. OBSERVE N.E.C. AND LOCAL UTILITY REQUIREMENTS FOR ELECTRICAL SERVICE
GROUNDING.
11. GROUNDING ATTACHMENT TO TOWER SHALL BE AS PER MANUFACTURER'S
RECOMMENDATIONS OR AT GROUNDING POINTS PROVIDED (2 MINIMUM).
12. IF EQUIPMENT IS IN A C.L. FENCE ENCLOSURE, GROUND ONLY CORNER POSTS AND
SUPPORT POSTS OF GATE. IF CHAIN LINK LID IS USED, THEN GROUND LID ALSO.
13. GROUNDING AT PPC CABINET SHALL BE VERTICALLY INSTALLED.
14. ALL GROUNDING FOR ANTENNAS SHALL BE CONNECTED SO THAT IT WILL BY-PASS MAIN
BUSS BAR.
15. ALL EMT RUNS SHALL BE GROUNDED AND HAVE A BUSHING, NO PVC ABOVE GROUND.
16. USE SEPARATE HOLES FOR GROUNDING AT BUSS BAR. NO "DOUBLE -UP" OF LUGS.
17. POWER AND TELCO CABINETS SHALL BE GROUNDED (BONDED) TOGETHER.
18. NO LB'S ALLOWED ON GROUNDING.
19. PROVIDE STAINLESS STEEL CLAMP AND BRASS TAGS ON COAX AT ANTENNAS AND
DOGHOUSE.
NOTE:
NEW VINYL SIGN TO BE PROVIDED BY AT&T AND BE LOCATED ON
THE SIDE OF THE METER BOX. SIGN TO BE YELLOW.
SHUTDOWN DISCONNECT SIGNAGE
NOT TO SCALE
at&t
5001 EXECUTIVE PARKWAY
SAN RAMON, CA 94583
fit Q D U S
modus-corp.com
240 STOCKTON STREET, 3RD, FLOOR
SAN FRANCISCO, CA 94108
borgesarch.com
1478 STONE POINT DRIVE, SUITE 350
ROSEVILLE CA 95661
916 782 7200 TEL
916 773 3037 FAX
3
06/12/19
100% CD Rev 2
2
02/22/18
100% CD Rev 1
1
12/04/17
100% CD Submittal
0
09/14/17
90% CD Submittal
REV
DATE
DESCRIPTION
SITE NUMBER:
SFOK02 017
SITE ADDRESS:
977 EL CAMINO REAL
BURLINGAME, CA 94010
STAMP
�SED ARC
�pSAM9p `°cr
No. C11535
F OF CAX-\F
DRAWN BY: A.P.E. PROJECT NO.: T-16509-86
CHECK BY: B.P.M.
SHgNbLE LINE
DIAGRAM AND
NOTES
SHEET NO.
E=1
6"
MIN
NEW GROUND CONDUCTOR
#2 GREEN COATED SOLID
COPPER WIRE
GROUND DETAIL
I" = 1 '-0"
NEW GALV IRON MOLDING
STAPLE TYP
NEW 3/8" DIA. HARDWOOD
MOLDING
NEW 1/2" PVC CONDUIT FOR
METER GROUND
EXISTING
— TYP MECHANICAL
CONNECTION
— 5/8" DIA. X 10'
GROUND ROD
GROUND LEGEND
O MECHANICAL CONNECTION
EXOTHERMIC CADWELD
TYP 5/8" DIA. X 10' LONG COPPER CLAD GROUND
ROD AT 10' O.C. MAX AND 18" MIN BELOW FINISH GRADE
/1 AVAIbid -III IEWA TAISIII W
�t
5001 EXECUTIVE PARKWAY
SAN RAMON, CA 94583
at&t
modus-corp.com
240 STOCKTON STREET, 3RD FLOOR
SAN FRANCISCO, CA 94108
borgesarch.com
1478 STONE POINT DRIVE, SUITE 350
ROSEVILLE CA 95661
916 782 7200 TEL
916 773 3037 FAX
3
06/12/19
100% CD Rev 2
2
02/22/18
100% CD Rev 1
1
12/04/17
100% CD Submittal
0
09/14/17
90% CD Submittal
REV
DATE
DESCRIPTION
SITE NUMBER:
SFOK02 017
SITE ADDRESS:
977 EL CAMINO REAL
BURLINGAME, CA 94010
STAMP
/SAD ARC
�pSAM9p `°cr
No. C11535
F OF CAX-\F
DRAWN BY: A.P.E. PROJECT NO.: T-16509-86
CHECK BY: B.P.M.
SHEET TITLE
POLE GROUND AND
DETAILS
SHEET NO.
GROUNDING PLAN
1/2" = 1'-0"
E=2