HomeMy WebLinkAboutReso - PC - 2020.04.27 - 8D2DocuSign Enveloie tD: DEA7B943- 19924629-840A-8EcD93E4sD97
RECORDING REQUESTED BY:
Planning Department
Ci$ of Burlingame
WHEN RECORDED MAIL TO:
COMMUNITY DEVELOPMENT DEPARTMENT
CITY OF BURLINGAME
501 PRIMROSE ROAD
BURLINGAME, CA 94010
2021-167797
10:37 am 12tOAt21 Rl Fee: NO FEE
Count of pages 6Rocorded in Officlal Records
County of San Mateo
Mark Church
fl 1t
ililfliilqtlilLru ilt[llrift m[iffinrry il1ll
Resolution No. 2020-04.27 -8d-2
RIGHT-OF-WAY ADJACENT TO 1480 BROADWAY
APN: N/A, lN RIGHT-OF-WAY
I hereby certify this to be a full, true and correct copy ofthe
document it purports to be, the original of which is on file in my
office.
October 2021
,.r{rstE
Date:
Kevin Gardiner, AICP,
k,^itn"
Development Di
(
RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF BURLINGAME
APPROVING AN APPLICATION FOR A CONDITIONAL USE PERMIT TO INSTALL A NEW
SMALL CELL WRELESS FACILITY (ANTENNA AND EQUIPMENT) ON AN EXISTING
WOOD UTILITY POLE LOCATED WTHIN THE RIGHT-OF.WAY ADJACENT
TO 1480 BROADWAY (EXIST|NG UTtLtTy POLE tS LOCATED ALONG EL CAMTNO REAL)
WHEREAS, on September 28, 2017, Abigait Reed, an agent for AT&T, filed an application
with the city of Burlingame community Development Department - Planning Division requesting
approval of the following request:
WHEREAS, on December 19, 2019 the Planning Commission conducted a noticed public
hearing (action meeting) to review and comment upon the proposed project. At that time the
Commission continued the application with the direction for the applicant to provide alternative
designs and information regarding the necessity to close significant gaps in coverage; and
WHEREAS, on April 27, 2020 the Planning Commission conducted a noticed public
hearing (action meeting). Following consideration of all information contained in the April 27,
2020 staff report to the Planning Commission regarding the project, all written correspondence,
and all public comments received at the public hearing, the Planning commission grants approval
of the application for a Conditional Use Permit based on the following findings:
That the proposed wireless facility complies with all the requirements of Chapter 25.77
and with all applicable requirements of other chapters of the Burlingame Municipal Code;
That the proposed wireless facility, at the proposed location, will not be detrimental or
injurious to property or improvements in the vicinity and will not be detrimental to the public
health, safety, general welfare, or convenience, because 'l)the proposed wireless facility
is located adjacent to an existing commercial use, 2) the proposed wireless facility
complies with the Federal Communications Commission's radio frequency (RF) emissions
regulations (confirmed by an evaluation of the proposed wireless facility prepared by
Hammett & Edison, lnc., Consulting Engineers, dated Septembet 26, 2017, and an
independent review by CTC Technology & Energy, dated December 2019) and 3) the
proposed wireless facility, consisting of an antenna and associated equipment mounted
on an existing PG&E owned wood utility pole, will be slightly wider than the existing pole
and will be concealed with a shield and painted to match the utility pole.
That the proposed use will be located and conducted in a manner in accord with the
Burlingame General Plan and the purposes of the Zoning Code.
1
RESOLUTION NO. 2020-04.27-8d2-Broadway
' Conditional Use Permit to install a new small cell wireless facility (antenna and equipment)
on an existing wood utility pole located within the righlof-way adjacent to ,1480 Broadway.
Conditional Use Permit Findinqs:
A,
RESO LUTION NO. RESOLUTION NO. 2020-04 .27 -gdz-Brcadw ay
NOW, THEREFORE, BE lT RESOLVED by the Planning Commission of the City of Burtingame,
that:
On the basis of the documents submitted and reviewed, and comments received and
evaluated, the Planning Commission finds that there is no substantial evidence that the
project set forth above will have a significant effect on the environment. The Planning
Commission further finds that categorical exemption, per CEQA Section 15303, which
states that construction and location of limited numbers of new, small facilities or
structures; installation of small new equipment and facilities in small structures; and the
conversion of existing small structures from one use to another where only minor
modifications are made in the exterior of the structure, is applicable to this project and is
approved.
A Conditional Use Permit is approved for the project subject to the following conditions of
approval. Findings for the Conditional Use Permit are set forth in the staff report, minutes,
and recordings of the said meeting. Conditions of approval:
that the conditional use permit to install a new small cell wireless communication facility
on an existing PG&E wood utility pole, located within the right-of-way adjacent to 1480
Broadway, consisting of a cylindrical antenna, extension on top of the utility pole, one
smartpole meter, two radio remote units, two twin diplexers, one ground bar, and one
electric load center, shall be valid for ten (10) years from the date of approval. At least
one hundred twenty (120) days prior to the expiration of the initial ten (10) year term, the
applicant shall complete and submit a renewal application to the Community Development
Director;
that the project shall be built as shown on the plans submitted to the Planning Division
date stamped April 18, 201 9, sheets T-1 , cN-1 , A-1 through A-4.2, E-1 and E-2;
that prior to commencing any work at the site, the contractor commissioned by the
applicant to perform the work shall obtain all required permits, such as a construction
Encroachment Permit and Stormwater Pollution Prevention Permit from the Department
of Public Works - Engineering Division;
that all units must be at least seven (7) feet clear and above the highest adjacent finished
grade, no exceptions shall be allowed;
that the wireless communication facility shall operate in conformance with all applicable
provisions of Chaptet 25.77 of the Burlingame Municipal Code (Wireless
Communications); where any conflicts exist between the applicable provisions of that
chapter and this approval, the more restrictive provision shall apply;
B
2
4
q
2
1.
A
RESOLUTION NO. RESOLUTION NO. 2020-04.27-8d2-Broadway
that the facility shall meet or exceed current standards and regulations of the FCC, the
FAA, and any other agency ofthe state orfederal government with the authority to regulate
wireless communication facilities. lf such standards and regulations are changed and are
made applicable to existing facilities, the owners of the facilities governed by this chapter
shall bring such facilities into compliance with such revised standards and regulations
within six (6) months of the effective date of such standards and regulations, unless a
different compliance schedule is mandated by the controlling state or federal agency.
Failure to bring the facility into compliance with such revised standards and regulations
shall constitute grounds for the removal of the facilities at the owner's expense, revocation
of any permit or imposition of any other applicable penalty;
that the facility shall be constructed of graffiti-resistant materials and shall be painted w1h
non-reflective material consistent with the color scheme on the utility pole;
that signage in, on or near the facility shall be prohibited with the exception of warning and
informational signs, which shall be designed with minimal aesthetic impact;
that within forty-five (45) days of commencement of the facility operation, the applicant
shall conduct a post-installation field test to confirm that the radio frequency (RF) exposure
levels comply with FCC Rules and Regulations and with City noise regulations, shall
submit the comprehensive report to the City, and if necessary, agree to prompfly correct
any noncompliance;
that the applicant shall procure and maintain a City business license, contact information
for the applicant, for the agent responsible for maintenance of the facility and for
emergency contact;
that the applicant shall either secure a bond, letter of credit or other similar financial
assurance, in a form acceptable to the City, for the removal of the facility in the event that
its use is abandoned, its operation is ceased or the approval is terminated;
that maintenance and repairs to facility shall be permitted provided that such maintenance
and repair does not enlarge or extend the facility structure or equipment enclosures or
change the number, type, dimensions, of the antenna or related equipment;
7
o
o
11
12.
13.
J
10. that the applicant shall report to the City every five (5) years from the date of
commencement of the facility operation, a review of the condition of the facility, of the
facility's compliance with federal and state regulations and of the facility's compliance with
the provisions of this chapter and the conditions of approval. The applicant shall also
provide updated contact information for the owner and the applicant and verifiable
confirmation information as to what carrier(s) are using the facility;
14
15
16
17
18.
20
RESOLUTIO N NO. RESOLUTI ON NO. 2020-04 .27 -8d2-Br oadw ay
that if the applicant intends to substitute the equipment installed pursuant to this permit
with subsequently-developed technology, such as "5G" equipment, the applicant or
responsible party shall provide sixty (60) days prior notice to the City and secure any
necessary permits before commencing such work;
that current contact information of the person or entity responsible for maintaining and
repairing the facility shall be provided to and maintained by the Community Development
Department;
that the facility shall be kept clean and free of graffiti, litter and debris. Lighting, walls,
fences, shields, cabinets, and poles, shall be maintained in good repair and free of graffiti
and other forms of vandalism, and any damage from any cause, including degradation
from wind and weather, shall be repaired as soon as reasonably possible to minimize
occurrences of dangerous conditions or visual blight. Graffiti shall be removed from any
facility as soon as practicable, and in no instance more than two (2) business days from
the time of notification by any person or entity;
that except for emergency repairs, testing and maintenance activities that will be audible
beyond the property line shall only occur between the hours of 8:00 a.m. and 6:00 p.m. on
Monday through Friday, excluding holidays;
that the service provider shall notify the community Development Director of the intent to
vacate a site at least thirty (30) days prior to the vacation;
(1)The Community Development Director has determined that the same operator
resumed operation; or
The City has received an application to transfer the permit to another service
provider.
(2)
that no later than ninety (90) days from the date the facility is determined to have ceased
operation or the Provider has notified the community Development Director of the intent
to vacate the site, the owner of the wireless communication facilities or the owner of the
property on which the facility is sited shall remove all equipment and improvements
associated with the use and shall restore the site to its original condition as required by
the community Development Director. The provider or owner may use any bond or other
assurances provided by the operator to do so. The owner or his or her agent shall provide
written verification of the removal of the facility within thirty (30) days of the date the
removal is completed.
19. that if the facility site is not operated for a continuous period of twelve ('t2) months, the
Conditional Use Permit shall be deemed terminated unless before the end of the twelve
('12) month period:
4
RESOLUTION NO. RESOLUTION NO. 2020 -04.27 -Bd2-Broadway
Chairperson
Richard Terrones Secretary of the Planning Commission of
the City of Burlingame, do hereby certify that the foregoing resolution was introduced and adopted
at a regular meeting of the Planning Commission held on the 27th dav of Aoril, 2020. by the
following vote:
Secreta ry
t,
1480 Broadw t _-.RESO 2020{4.27{.t2€roadvavAYES: COIiAROTO, GAUL, LOflS,
-
SARGEiIT, SCHf,ID, TERROT{ES, TSENOES: NONE
ABSEI'IT: NONE
RECUSED: NOI{E
5
T-1
TITLE SHEET
TITLE SHEET T-1
SHEET INDEX PROJECT INFORMATION
Property Information:
Site Name: CRAN_RSFR_SFOK2_016
Site Number: SFOK2_016
Site Address: ACROSS FROM: 1480 BROADWAY
BURLINGAME, CA, 94010
A.P.N. Number: ----
Current Zoning: N/A - PUBLIC RIGHT OF WAY
Jurisdiction: BURLINGAME
Latitude: N 37 35' 03.61"
Longitude: W 122 21' 58.92"
Elevation: 36± AMSL AT GROUND (NAVD 88)
Power Agency:
PG&E
1 MARKET STREET, SPEAR TOWER
SAN FRANCISCO, CA 94105-1126
Telephone Agency:
AT&T
525 MARKET STREET
SAN FRANCISCO, CA 94105
ph: (415) 778-1231
PROJECT TEAM
Agent:
Jimmy Stillman
Modus-Corporation, Inc.
240 Stockton Street, 3rd Floor
San Francisco, CA 94108
ph: (530) 913-9577
email: jstillman@modus-corp.com
GENERAL CONTRACTOR NOTES
DO NOT SCALE DRAWINGS
THESE DRAWINGS ARE FORMATTED TO BE FULL SIZE AT 36" x 24" (D1). CONTRACTOR SHALL VERIFY ALL
PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOBSITE AND SHALL IMMEDIATELY
NOTIFY THE ARCHITECT/ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH
THE WORK OR MATERIAL ORDERS OR BE RESPONSIBLE FOR THE SAME.
DIRECTIONS FROM AT&T's OFFICE
DIRECTIONS FROM AT&T's OFFICE AT 5001 EXECUTIVE PARKWAY, SAN RAMON, CA
1.HEAD NORTHEAST ON BISHOP DR TOWARD SUNSET DR
2.TURN RIGHT ONTO SUNSET DR
3.USE THE RIGHT 2 LANES TO TURN RIGHT ONTO BOLLINGER CANYON RD
4.USE THE RIGHT LANE TO MERGE ONTO I-680 S VIA THE RAMP TO SAN JOSE
5.MERGE ONTO I-680 S
6.TAKE EXIT 30B TO MERGE ONTO I-580 W TOWARD DUBLIN/OAKLAND
7.KEEP LEFT AT THE FORK TO CONTINUE ON I-238 N, FOLLOW SIGNS FOR I-880
8.USE THE RIGHT 2 LANES TO TAKE EXIT 16A FOR INTERSTATE 880 S TOWARD SAN JOSE/SAN MATEO
BRIDGE
9.MERGE ONTO I-880 S
10.USE THE RIGHT 2 LANES TO TAKE EXIT 27 TO MERGE ONTO CA-92 W TOWARD SAN MATEO
BRIDGE/JACKSON ST
11.USE THE RIGHT 2 LANES TO TAKE EXIT 13B TO MERGE ONTO US-101 N TOWARD SAN FRANCISCO
12.USE THE RIGHT 2 LANES TO TAKE EXIT 419B FOR BROADWAY
13.TURN RIGHT ONTO BROADWAY
14.1480 BROADWAY
VICINITY MAP
THIS IS AN UNMANNED WIRELESS TELECOMMUNICATION FACILITY FOR AT&T
MOBILITY CONSISTING OF THE INSTALLATION AND OPERATION OF AN ANTENNA
AND ASSOCIATED EQUIPMENT ON AN EXISTING WOOD UTILITY POLE IN THE
PUBLIC RIGHT OF WAY.
OCCUPANCY AND CONSTRUCTION TYPE
OCCUPANCY : N/A
CONSTRUCTION TYPE: G.O. 128 AND 2009 AASHTO 5TH EDITION
STANDARD
ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN
ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS
ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE
PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE
CODES.
1.2016 CALIFORNIA ADMINISTRATIVE CODES (INCL. TITLES 24 & 25)
2.2016 CALIFORNIA BUILDING CODE
3.2016 CALIFORNIA ELECTRICAL CODE
4.2016 CALIFORNIA MECHANICAL CODE
5.2016 CALIFORNIA PLUMBING CODE
6.2016 CALIFORNIA FIRE CODE
7.2016 CALIFORNIA GREEN BUILDING CODE
8.2016 CALIFORNIA ENERGY CODE
9.2016 SAN FRANCISCO CODE AMENDMENTS
10.2016 SAN FRANCISCO BUILDING CODE AMENDMENTS
11.2016 SAN FRANCISCO ELECTRICAL CODE AMENDMENTS
12.2016 SAN FRANCISCO MECHANICAL CODE AMENDMENTS
13.2016 SAN FRANCISCO PLUMBING CODE AMENDMENTS
14.2016 SAN FRANCISCO FIRE CODE AMENDMENTS
15.2016 SAN FRANCISCO GREEN BUILDING CODE AMENDMENTS
16.2016 SAN FRANCISCO HOUSING CODE
DISABLED ACCESS REQUIREMENTS
FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION, ACCESSIBILITY
REQUIREMENTS ARE NOT REQUIRED, IN ACCORDANCE WITH CALIFORNIA
BUILDING CODE, CODE OF REGULATIONS, TITLE 24, PART 2, VOLUME 1,
CHAPTER 11B, DIVISION 2, SECTION 11B-203.5
CODE COMPLIANCE
SURVEYC-1
Project Manager:
Jimmy Stillman
Modus-Corporation, Inc.
240 Stockton Street, 3rd Floor
San Francisco, CA 94108
ph: (530) 913-9577
email: jstillman@modus-corp.com
Construction Manager:
Kresston Haynes
Modus-Corporation, Inc.
240 Stockton Street, 3rd Floor
San Francisco, CA 94108
ph: (209) 938-7251
email: khaynes@modus-corp.com
Architect / Engineer of Record:
Borges Architectural Group, Inc.
1478 Stone Point Drive, Suite 350
Roseville, CA 95661
contact: Brendan P. McNulty
ph: (916) 782-7200
email: telecomgroup@borgesarch.com
AT&T Project Manager:
Marc Grabisch, SAQ PM
AT&T Mobility
5001 Executive Parkway
San Ramon, CA 94583
ph: (925) 549-9671
email: mg387k@att.com
RF Manager:
Jeric Lizardo
AT&T Mobility
5001 Executive Parkway
San Ramon, CA 94583
ph: (925) 365-0155
email: j8771@att.com
SHEET NO.SHEET TITLE
SITE PLANA-1
ENLARGED SITE PLAN & ANTENNA PLANA-2
ELEVATIONSA-3
GENERAL NOTESGN-1
PROJECT DESCRIPTION
SCOPE OF WORK & SITE COMPLETION CHECKLIST
AT&T Construction Manager:
Leo Ruazol, CX PM
AT&T Mobility
5001 Executive Parkway
San Ramon, CA 94583
ph: (650) 787-6814
email: LR2164@att.com
SITE
Plot Date:6/12/2019 8:49:00 AM File NameT:\2016\T-16509_Modus_SF_CRAN_AT&T\SFOK2_016-85\SFOK2_016\Sheets\Building A\T-1 Title Sheet.dwg Plotted By:Brendan McNulty1478 STONE POINT DRIVE, SUITE 350
ROSEVILLE CA 95661
TEL
FAX
borgesarch.com
916 782 7200
916 773 3037
SHEET NO.
SHEET TITLE
DRAWN BY: A.P.E.
CHECK BY: B.P.M.
PROJECT NO.: T-16509-85
STAMP
REV DESCRIPTIONDATE
240 STOCKTON STREET, 3RD FLOOR
SAN FRANCISCO, CA 94108
modus-corp.com
5001 EXECUTIVE PARKWAY
SAN RAMON, CA 94583
No. C11535
0 09/13/17 90% CD Submittal
SITE NUMBER:
SFOK2_016
SITE ADDRESS:
1480 BROADWAY
BURLINGAME, CA, 94010
1 09/25/17 100% CD Submittal
2 02/22/18 100% CD Rev 1
3 06/11/19 100% CD Rev 2
DETAILSA-4.1
SINGLE LINE DIAGRAM & PANEL SCHEDULEE-1
POLE GROUND & RISER DIAGRAM & DETAILSE-2
SITE NUMBER: SFOK2_016
FA#: 13789365
SITE NAME: CRAN_RSFR_SFK02_016
SITE ADDRESS: 1480 BROADWAY
BURLINGAME, CA, 94010
COUNTY: SAN MATEO
SITE TYPE:PG&E WOOD UTILITY POLE
HUB LOCATION:SNFCCA21 611 FOLSOM ST
POLE OWNER:JPA
·ANTENNA & ASSOCIATED EQUIPMENT BOXES - INSTALL A NEW
TELECOMMUNICATION ANTENNA AND EQUIPMENT BOXES ON AN
EXISTING WOOD UTILITY POLE ON GO95 COMPLIANT STANDOFF BRACKET.
INSTALLATION CONSISTS OF (1) CANISTER ANTENNA, (2) TWIN DIPLEXERS,
(1) 4415 RADIO WITH PSU-08 & (1) 4426 RADIO WITH PSU-08 IN SOLAR
SHIELDS , (1) SMARTPOLE METER, (1) LOAD CENTER.
·CABLING - CABLING TO BE INSTALLED IN A TIDY MANNER WITHOUT EXCESS
CABLE LOOPS
·SPACING OF SUPPORT ELEMENTS - SUPPORT EQUIPMENT (E.G. RRUS) TO BE
CLUSTERED (VERTICALLY) AS CLOSE AS TECHNICALLY FEASIBLE ON POLE.
·LOGO REMOVAL - ALL EQUIPMENT LOGOS, OTHER THAN THOSE REQUIRED
BY REGULATION (E.G. NODE IDENTIFICATION) SHALL BE PAINTED OVER OR
REMOVED. RAISED OR DEPRESSED TEXT ON RRUS OR OTHER EQUIPMENT, IF
PRESENT, SHALL BE SANDED OFF OR SIMILARLY REMOVED / FILLED.
·SIGNAGE - FCC MANDATED RF WARNING SIGNAGE SHALL FACE OUT TO
STREET WHEN PLACED IN FRONT OF, OR NEAR A WINDOW. SIGNAGE
SHALL FACE TOWARD A BUILDING IF THERE IS NO WINDOW.
·ALL CABLING, ANTENNAS, AND EQUIPMENT TO BE PAINTED TO MATCH
POLE
DETAILSA-4.2
Plot Date:6/12/2019 8:49:11 AM File NameT:\2016\T-16509_Modus_SF_CRAN_AT&T\SFOK2_016-85\SFOK2_016\Sheets\Building A\GN-1 General Notes.dwg Plotted By:Brendan McNulty1478 STONE POINT DRIVE, SUITE 350
ROSEVILLE CA 95661
TEL
FAX
borgesarch.com
916 782 7200
916 773 3037
SHEET NO.
SHEET TITLE
DRAWN BY: A.P.E.
CHECK BY: B.P.M.
PROJECT NO.: T-16509-85
STAMP
REV DESCRIPTIONDATE
240 STOCKTON STREET, 3RD FLOOR
SAN FRANCISCO, CA 94108
modus-corp.com
5001 EXECUTIVE PARKWAY
SAN RAMON, CA 94583
No. C11535
0 09/13/17 90% CD Submittal
SITE NUMBER:
SFOK2_016
SITE ADDRESS:
1480 BROADWAY
BURLINGAME, CA, 94010
1 09/25/17 100% CD Submittal
2 02/22/18 100% CD Rev 1
3 06/11/19 100% CD Rev 2
GN-1
GENERAL NOTES
1.THESE NOTES SHALL BE CONSIDERED A PART OF THE WRITTEN SPECIFICATIONS, CONTRACT AND CONSTRUCTION DOCUMENTS.
2.THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES, AND LABOR NECESSARY TO COMPLETE ALL
INSTALLATIONS AS INDICATED ON THE PLANS AND IN THE CONTRACT DOCUMENTS.
3.PRIOR TO THE SUBMISSION OF BIDS, THE CONTRACTOR(S) SHALL VISIT THE JOB SITE(S) AND BE RESPONSIBLE FOR ALL CONTRACT
DOCUMENTS, FIELD CONDITIONS AND DIMENSIONS, AND CONFIRM THE WORK MAY BE ACCOMPLISHED PER THE CONTRACT DRAWINGS.
ANY DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION OF THE IMPLEMENTATION ENGINEER AND ARCHITECT / ENGINEER PRIOR TO
BID SUBMITTAL.
4.THE CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED ON ANY WORK NOT CLEARLY DEFINED OR IDENTIFIED IN THE
CONTRACT AND CONSTRUCTION DOCUMENTS BEFORE STARTING ANY WORK.
5.ALL WORK PERFORMED AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND
ORDINANCES, INCLUDING APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS.
6.THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS. IF THE
RECOMMENDATIONS ARE IN CONFLICT WITH THE CONTRACT AND CONSTRUCTION DOCUMENTS AND/OR APPLICABLE CODES OR
REGULATIONS, REVIEW AND RESOLVE THE CONFLICT WITH DIRECTION FROM THE IMPLEMENTATION ENGINEER AND ARCHITECT/ENGINEER
OF RECORD PRIOR TO PROCEEDING.
7.THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND
PROCEDURES AND FOR COORDINATION OF ALL PORTIONS OF THE WORK UNDER THE CONTRACT INCLUDING CONTACT AND
COORDINATION WITH THE IMPLEMENTATION ENGINEER AND WITH THE AUTHORIZED REPRESENTATIVE OF ANY OUTSIDE POLE OR PROPERTY
OWNER.
8.THE CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS, INCLUDING BUT NOT LIMITED TO PAVING,
CURBS, VEGETATION, GALVANIZED SURFACE OR OTHER EXISTING ELEMENTS AND UPON COMPLETION OF THE WORK, REPAIR AND
DAMAGE THAT OCCURRED DURING CONSTRUCTION TO THE SATISFACTION OF AT&T MOBILITY.
9.CONTRACTOR IS TO KEEP THE GENERAL AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DIRT, DEBRIS, RUBBISH, AND REMOVE
EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY. LEAVE PREMISES IN CLEAN CONDITION DAILY.
10.PLANS ARE INTENDED TO BE DIAGRAMMATIC ONLY AND SHOULD NOT BE SCALED UNLESS OTHERWISE NOTED. RELY ONLY ON ANNOTATED
DIMENSIONS AND REQUEST INFORMATION IF ADDITIONAL DIMENSIONS ARE REQUIRED.
11.THE EXISTENCE AND LOCATION OF UTILITIES AND OTHER AGENCY'S FACILITIES WERE OBTAINED BY A SEARCH OF AVAILABLE RECORDS.
OTHER FACILITIES MAY EXIST. CONTRACTOR SHALL VERIFY LOCATIONS PRIOR TO START OF CONSTRUCTION AND USE EXTREME CARE AND
PROTECTIVE MEASURES TO PREVENT DAMAGE TO THE FACILITIES. CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF UTILITIES OR
OTHER AGENCY'S FACILITIES WITHIN THE LIMITS OF THE WORK, WHETHER THEY ARE IDENTIFIED IN THE CONTRACT DOCUMENTS OR NOT.
12.THE CONTRACTOR SHALL NOTIFY UNDERGROUND SERVICE ALERT (800) 227-2600, AT LEAST TWO WORKING DAYS PRIOR TO START OF ANY
EXCAVATION.
GENERAL NOTES:
DEFINITIONS:
1."TYPICAL" OR "TYP" MEANS THAT THIS ITEM IS SUBSTANTIALLY THE SAME ACROSS SIMILAR CONDITIONS. "TYP" SHALL BE UNDERSTOOD TO
MEAN "TYPICAL WHERE OCCURS" AND SHALL NOT BE CONSIDERED AS WITHOUT EXCEPTION OR CONSIDERATION OF SPECIFIC
CONDITIONS.
2."SIMILAR" MEANS COMPARABLE TO CHARACTERISTICS FOR THE CONDITION NOTED. VERIFY DIMENSIONS AND ORIENTATION ON PLAN.
3."AS REQUIRED" MEANS AS REQUIRED BY REGULATORY REQUIREMENTS, BY REFERENCES STANDARDS, BY EXISTING CONDITIONS, BY
GENERALLY ACCEPTED CONSTRUCTION PRACTICE, OR BY THE CONTRACT DOCUMENTS.
4."ALIGN" MEANS ACCURATELY LOCATE FINISH FACES OF MATERIALS IN THE SAME PLANE.
5.THE TERM "VERIFY" OF "V.I.F." SHALL BE UNDERSTOOD TO MEAN "VERIFY IN FIELD WITH ENGINEER" AND REQUIRES THAT THE CONTRACTOR
CONFIRM INTENTION REGARDING NOTED CONDITION AND PROCEED ONLY AFTER RECEIVING DIRECTION.
6.WHERE THE WORDS "OR EQUAL" OR WORDS OF SIMILAR INTENT FOLLOW A MATERIAL SPECIFICATION, THEY SHALL BE UNDERSTOOD TO
REQUIRE SIGNED APPROVAL OF ANY DEVIATION TO SAID SPECIFICATION PRIOR TO CONTRACTOR'S ORDERING OR INSTALLATION OF SUCH
PROPOSED EQUAL PRODUCT.
7."FURNISH" MEANS SUPPLY ONLY, OTHERS TO INSTALL.
8."INSTALL" MEANS INSTALL ITEMS FURNISHED BY OTHERS.
9."PROVIDE" MEANS FURNISH AND INSTALL.
OFFICE
101 ROOM NUMBER
WALL TYPE MARK
KEYNOTE,
CONSTRUCTION ITEM
KEYNOTE,
DIMENSION ITEM
ROOM NAME
WALL SECTION
DETAIL
W-3
BLDG. SECTIONA-300
1
A-500
D5
A-310
A5
A-113
C1
A-113
C4
A-113
A1
A-113
A4 ELEVATION
3
2
CENTERLINE
ELEVATION DATUM
TILT-UP PANEL MARK
WINDOW SYMBOL
DOOR SYMBOL
PROPERTY LINE
3
±0"
001
10
A GRID/COLUMN LINE
A-300
1
GROUT OR PLASTER
(E) BRICK
(E) MASONRY
CONCRETE
EARTH
GRAVEL
PLYWOOD
SAND
PLYWOOD
SAND
(E) STEEL
MATCH LINE
GROUND CONDUCTOR
TELEPHONE CONDUIT
POWER CONDUIT
COAXIAL CABLE
Tel
Pwr
Coax
CHAIN LINK FENCE
OVERHEAD SERVICE CONDUCTORSOH
WOOD FENCE
SYMBOL LEGEND:
A.B.ANCHOR BOLT
ABV.ABOVE
ACCA ANTENNA CABLE COVER ASSEMBLY
ADD'L ADDITIONAL
A.F.F.ABOVE FINISHED FLOOR
A.F.G.ABOVE FINISHED GRADE
ALUM.ALUMINUM
ALT.ALTERNATE
ANT.ANTENNA
APPRX.APPROXIMATE(LY)
ARCH.ARCHITECT(URAL)
AWG.AMERICAN WIRE GAUGE
BLDG.BUILDING
BLK.BLOCK
BLKG.BLOCKING
BM.BEAM
B.N.BOUNDARY NAILING
BTCW.BARE TINNED COPPER WIRE
B.O.F.BOTTOM OF FOOTING
B/U BACK-UP CABINET
CAB.CABINET
CANT.CANTILEVER(ED)
C.I.P.CAST IN PLACE
CLG.CEILING
CLR.CLEAR
COL.COLUMN
CONC.CONCRETE
CONN.CONNECTION(OR)
CONST.CONSTRUCTION
CONT.CONTINUOUS
d PENNY (NAILS)
DBL.DOUBLE
DEPT.DEPARTMENT
D.F.DOUGLAS FIR
DIA.DIAMETER
DIAG.DIAGONAL
DIM.DIMENSION
DWG.DRAWING(S)
DWL.DOWEL(S)
EA.EACH
EL.ELEVATION
ELEC.ELECTRICAL
ELEV.ELEVATOR
EMT.ELECTRICAL METALLIC TUBING
E.N.EDGE NAIL
ENG.ENGINEER
EQ.EQUAL
EXP.EXPANSION
EXST.(E)EXISTING
EXT.EXTERIOR
FAB.FABRICATION(OR)
F.F.FINISH FLOOR
F.G.FINISH GRADE
FIN.FINISH(ED)
FLR.FLOOR
FDN.FOUNDATION
F.O.C.FACE OF CONCRETE
F.O.M.FACE OF MASONRY
F.O.S.FACE OF STUD
F.O.W.FACE OF WALL
F.S.FINISH SURFACE
FT.( ' )FOOT (FEET)
FTG.FOOTING
G.GROWTH (CABINET)
GA.GAUGE
GI.GALVANIZE(D)
G.F.I.GROUND FAULT CIRCUIT INTERRUPTER
GLB. (GLU-LAM)GLUE LAMINATED BEAM
GPS GLOBAL POSITIONING SYSTEM
GRND.GROUND
HDR.HEADER
HGR.HANGER
HT.HEIGHT
ICGB.ISOLATED COPPER GROUND BUS
IN. ( " )INCH(ES)
INT.INTERIOR
LB.(#)POUND(S)
L.B.LAG BOLTS
L.F.LINEAR FEET (FOOT)
L.LONG(ITUDINAL)
MAS.MASONRY
MAX.MAXIMUM
M.B.MACHINE BOLT
MECH.MECHANICAL
MFR.MANUFACTURER
MIN.MINIMUM
MISC.MISCELLANEOUS
MTL.METAL
(N)NEW
NO.(#)NUMBER
N.T.S.NOT TO SCALE
O.C.ON CENTER
OPNG.OPENING
P/C PRECAST CONCRETE
PCS PERSONAL COMMUNICATION SERVICES
PLY.PLYWOOD
PPC POWER PROTECTION CABINET
PRC PRIMARY RADIO CABINET
P.S.F.POUNDS PER SQUARE FOOT
P.S.I.POUNDS PER SQUARE INCH
P.T.PRESSURE TREATED
PWR.POWER (CABINET)
QTY.QUANTITY
RAD.(R)RADIUS
REF.REFERENCE
REINF.REINFORCEMENT(ING)
REQ'D/REQUIRED
RGS.RIGID GALVANIZED STEEL
SCH.SCHEDULE
SHT.SHEET
SIM.SIMILAR
SPEC.SPECIFICATIONS
SQ.SQUARE
S.S.STAINLESS STEEL
STD.STANDARD
STL.STEEL
STRUC.STRUCTURAL
TEMP.TEMPORARY
THK.THICK(NESS)
T.N.TOE NAIL
T.O.A.TOP OF ANTENNA
T.O.C.TOP OF CURB
T.O.F.TOP OF FOUNDATION
T.O.P.TOP OF PLATE (PARAPET)
T.O.S.TOP OF STEEL
T.O.W.TOP OF WALL
TYP.TYPICAL
U.G.UNDER GROUND
U.L. UNDERWRITERS LABORATORY
U.N.O.UNLESS NOTED OTHERWISE
V.I.F.VERIFY IN FIELD
W WIDE (WIDTH)
w/WITH
WD.WOOD
W.P.WEATHERPROOF
WT.WEIGHT
C CENTERLINE
P PLATE, PROPERTY LINE
L
L
ABBREVIATIONS:
17 1/8" = 1'-0"
OVERALL SITE PLAN
A-2
17
(E) WOOD UTILITY POLE
HT. 30.5'±
(E) TRAFFIC VAULT
(E) ELECTRICAL VAULT
(E) WOOD UTILITY POLE
(E) TRAFFIC VAULT
(E) GAS STATION SIGN
(E) LIGHT VAULT
(E) GAS VALVE
(E) TRAFFIC VAULT
(E) TRAFFIC
SIGNAL POLE
(E) OVERHEAD
UTILITY LINES
(E) TRAFFIC VAULT
(E) COMMUNICATION
VAULT
(E) TRAFFIC VAULT
(E) OVERHEAD
UTILITY LINES
(E) OVERHEAD
UTILITY LINES
(E) STREET LIGHT POLE
(E) WATER METER
(E) VAULT
(E) CONCRETE SIDEWALK
(E) CONCRETE SIDEWALK
(E) CONCRETE SIDEWALK
EL
C
A
M
I
N
O
R
E
A
L BROADWAYAPN: 0026-212-280
(E) BUILDING
(E) BUILDING
APN: 0026-096-170
(E) GAS PUMP CANOPY
(E) GAS PUMP CANOPY
(E
)
P
R
O
P
E
R
T
Y
B
O
U
N
D
A
R
Y (E) PROPERTY BOUNDARY(E) PROPERTY BOUNDARY(E) LIP OF GUTTER
(E) OVERHEAD
UTILITY LINES
(E) STREET LIGHT
LEGEND:
WATER:
SANITARY SEWER:
STORM DRAIN:
OVERHEAD UTILITY LINES:
(P) ANTENNA MOUNTED ON TOP OF (E) UTILITY
POLE w/ (1) 4415 RADIO w/ PSU-08 & (1) 4426
RADIO W/ PSU-08 INSIDE (P) SOLAR SHIELD
MOUNTED ON (E) UTILITY POLE
Plot Date:6/12/2019 8:49:27 AM File NameT:\2016\T-16509_Modus_SF_CRAN_AT&T\SFOK2_016-85\SFOK2_016\Sheets\Building A\A-1 Site Plan.dwg Plotted By:Brendan McNulty1478 STONE POINT DRIVE, SUITE 350
ROSEVILLE CA 95661
TEL
FAX
borgesarch.com
916 782 7200
916 773 3037
SHEET NO.
SHEET TITLE
DRAWN BY: A.P.E.
CHECK BY: B.P.M.
PROJECT NO.: T-16509-85
STAMP
REV DESCRIPTIONDATE
240 STOCKTON STREET, 3RD FLOOR
SAN FRANCISCO, CA 94108
modus-corp.com
5001 EXECUTIVE PARKWAY
SAN RAMON, CA 94583
No. C11535
0 09/13/17 90% CD Submittal
SITE NUMBER:
SFOK2_016
SITE ADDRESS:
1480 BROADWAY
BURLINGAME, CA, 94010
1 09/25/17 100% CD Submittal
2 02/22/18 100% CD Rev 1
3 06/11/19 100% CD Rev 2
A-1
SITE PLAN
8'4'8'16'
1/8"=1'-0"
00
N
17 1/2" = 1'-0"
ENLARGED SITE PLAN
(E) OVERHEAD UTILITY LINE (E) PROPERTY BOUNDARYA-2
5
(E) OVERHEAD UTILITY LINE
(E) BUILDING
(E) WOOD UTILITY POLE
HT. 30.5'±
(E) GAS STATION SIGN
(E) GAS VALVE
(E) TRAFFIC
SIGNAL POLE
(E) TRAFFIC VAULT
(E) STREET LIGHT POLE
(E) WATER METER
(E) VAULT
(E) LIP OF GUTTER
E
L
C
AM
I
NO
R
E
A
L
(E) CONCRETE SIDEWALK
LEGEND:
WATER:
SANITARY SEWER:
STORM DRAIN:
OVERHEAD UTILITY LINES:
(P) ANTENNA MOUNTED ON TOP OF (E) UTILITY
POLE w/ (1) 4415 RADIO w/ PSU-08 & (1) 4426
RADIO W/ PSU-08 INSIDE (P) SOLAR SHIELD
MOUNTED ON (E) UTILITY POLE
5 1" = 1'-0"
ENLARGED ANTENNA PLAN
(P) ANTENNA MOUNTED ON
TOP OF (E) UTILITY POLE
(P) 3" COAX RISER
(P) 1 1/2" AC POWER RISER
(P) (1) 4415 RADIO w/ PSU-08
& (1) 4426 RADIO W/ PSU-08
INSIDE (P) SOLAR SHIELD
MOUNTED ON (E) UTILITY POLE
4 3" = 1'-0"
TWIN DIPLEXER DETAIL
TWIN DIPLEXER MAKE AND MODEL:
MANUFACTURER: COMMSCOPE
MODEL: CBC1923T-4310-E11F13P06
DIMENSIONS, HxWxD: 8.3" x 4.6" x 1.8"
WEIGHT: 5.5 lbs PER UNIT
4 5/8"2 1/2"1 3/4"TOP:
SIDE:FRONT:
8 3/8"8 7/8"(2) TWIN DIPLEXERS
3 1" = 1'-0"
POWER METER MOUNTING DETAIL
12
3
6
(P) SMARTPOLE METER
9 4"NOTE: 30"X30"
UNOBSTRUCTED
CLIMBING SPACE
(P) 2" SQ. STEEL TUBE
(P) 3/8" "C" ALUMINUM
CHANNEL, 8" WIDE
(P) 1 1/2" CONDUIT
(P) UNISTRUT P1000 OR EQ.
(P) 5/8" ANTI-SPLIT
GALVANIZED
THRU-BOLT (TYP)
(E) UTILITY POLE
8 1" = 1'-0"
RRUS-32 MOUNTING DETAIL
12
3
6 NOTE: 30"X30"
UNOBSTRUCTED
CLIMBING SPACE
(P) 2" SQ. STEEL TUBE
(P) 5/8" ANTI-SPLIT
GALVANIZED
THRU-BOLT (TYP)
(P) 3/8" "C" ALUMINUM
CHANNEL, 8" WIDE
(E) UTILITY POLE
(P) 1 1/2" CONDUIT
(P) 3" COAX CONDUIT
9 4"(1) (P) 4415 RADIO w/ PSU-08 & (1) (P) 4426
RADIO w/ PSU-08 INSIDE (P) SOLAR SHIELD
(P) UNISTRUT P1000 OR EQ.
8 1" = 1'-0"
RRUS-32 MOUNTING DETAIL
12
3
6 NOTE: 30"X30"
UNOBSTRUCTED
CLIMBING SPACE
(P) 2" SQ. STEEL TUBE
(P) 5/8" ANTI-SPLIT
GALVANIZED
THRU-BOLT (TYP)
(P) 3/8" "C" ALUMINUM
CHANNEL, 8" WIDE
(E) UTILITY POLE
(P) 1 1/2" CONDUIT
(P) 3" COAX CONDUIT
9 4"(1) (P) 4415 RADIO w/ PSU-08 & (1) (P) 4426
RADIO w/ PSU-08 INSIDE (P) SOLAR SHIELD
(P) UNISTRUT P1000 OR EQ.Plot Date:6/12/2019 8:50:07 AM File NameT:\2016\T-16509_Modus_SF_CRAN_AT&T\SFOK2_016-85\SFOK2_016\Sheets\Building A\A-2 Enlarged Site Plan & Antenna Plan.dwg Plotted By:Brendan McNulty1478 STONE POINT DRIVE, SUITE 350
ROSEVILLE CA 95661
TEL
FAX
borgesarch.com
916 782 7200
916 773 3037
SHEET NO.
SHEET TITLE
DRAWN BY: A.P.E.
CHECK BY: B.P.M.
PROJECT NO.: T-16509-85
STAMP
REV DESCRIPTIONDATE
240 STOCKTON STREET, 3RD FLOOR
SAN FRANCISCO, CA 94108
modus-corp.com
5001 EXECUTIVE PARKWAY
SAN RAMON, CA 94583
No. C11535
0 09/13/17 90% CD Submittal
SITE NUMBER:
SFOK2_016
SITE ADDRESS:
1480 BROADWAY
BURLINGAME, CA, 94010
1 09/25/17 100% CD Submittal
2 02/22/18 100% CD Rev 1
3 06/11/19 100% CD Rev 2
A-2
ENLARGED SITE
PLAN & ANTENNA
PLAN
1/2"=1'-0"
01'2'2'4'0
N
1'0.5'1'2'0
1"=1'-0"
0
N
17 1/2" = 1'-0"
EXISTING NORTH ELEVATION
(E) WOOD UTILITY POLE
0'-0"
GRADE LEVEL
24'-0"
TOP OF (E) UTILITY LINE AND ANCHOR POINT
28'-0"
BOTTOM OF (E) LIGHT ARM
28'-11"
TOP OF (E) STREET LIGHT
30'-6"
TOP OF (E)WOOD UTILITY POLE
(E) STREET LIGHT
(E) UTILITY LINES AND
ANCHOR POINTS
(E) ROW
(E) CONCRETE SIDEWALK
9 1/2" = 1'-0"
PROPOSED NORTH ELEVATION
7
30'-6"
TOP OF (E) WOOD UTILITY POLE
24'-0"
TOP OF (E) UTILITY LINE AND ANCHOR POINT
(P) 2'-0" COMMUNICATIONS
SAFETY ZONE PER GO95
0'-0"
GROUND LEVEL
28'-0"
BOTTOM OF (E) LIGHT ARM
28'-11"
TOP OF (E) STREET LIGHT
(E) WOOD UTILITY POLE
(E) STREET LIGHT
(E) UTILITY LINES AND
ANCHOR POINTS
(E) CONCRETE SIDEWALK
(P) AT&T ANTENNA MOUNTED TO
(P) 7' EXTENSION ON TOP OF (E)
UTILITY POLE
(P) 6'-0" POWER SAFETY
ZONE PER GO 95
38'-9"
RAD CENTER OF (P) AT&T ANTENNA
39'-10"
TOP OF (P) AT&T ANTENNA
(P) 3" COAX RISER
(P) RF WARNING SIGN
37'-3"
TOP OF COAX RISER / BOTTOM OF
(P) ANTENNA BRACKET
(P) AT&T FIBER P.O.C.
(P) 2" FIBER RISER FROM AT&T TO (P) FIBER
DEMARK ENCLOSURE NEXT TO LOAD
CENTER ON POLE
(P) SMARTPOLE METER
(P) ELECTRIC LOAD CENTER
(P) SOLAR SHIELD TO HAVE SLATS
ON BOTH SIDES, TOP AND
BOTTOM TO REMAIN OPEN
16'-0"
TOP OF (P) SOLAR SHIELD
7'-0"
BOTTOM OF (P) LOAD CENTER
8'-1"
TOP OF (P) LOAD CENTER
8'-7"
BOTTOM OF (P) SMARTPOLE METER
9'-2"
TOP OF (P) SMARTPOLE METER
10'-2"
BOTTOM OF (P) SOLAR SHIELD
(P) 4426 RADIO w/
PSU-08 INSIDE (P)
SOLAR SHROUD
(P) 4415 RADIO w/ PSU-08, (P) (2)
TWIN DIPLEXERS, AND (P)
GROUND BAR INSIDE (P) SOLAR
SHROUD
(P) (2) TWIN DIPLEXERS
(P) GROUND BAR
Plot Date:6/12/2019 8:50:32 AM File NameT:\2016\T-16509_Modus_SF_CRAN_AT&T\SFOK2_016-85\SFOK2_016\Sheets\Building A\A-3 Elevations.dwg Plotted By:Brendan McNulty1478 STONE POINT DRIVE, SUITE 350
ROSEVILLE CA 95661
TEL
FAX
borgesarch.com
916 782 7200
916 773 3037
SHEET NO.
SHEET TITLE
DRAWN BY: A.P.E.
CHECK BY: B.P.M.
PROJECT NO.: T-16509-85
STAMP
REV DESCRIPTIONDATE
240 STOCKTON STREET, 3RD FLOOR
SAN FRANCISCO, CA 94108
modus-corp.com
5001 EXECUTIVE PARKWAY
SAN RAMON, CA 94583
No. C11535
0 09/13/17 90% CD Submittal
SITE NUMBER:
SFOK2_016
SITE ADDRESS:
1480 BROADWAY
BURLINGAME, CA, 94010
1 09/25/17 100% CD Submittal
2 02/22/18 100% CD Rev 1
3 06/11/19 100% CD Rev 2
A-3
ELEVATIONS
NOTES:
1.PAINT RRU SOLAR SHIELD, MOUNTING COMPONENTS & CABLE SWEEP TO MATCH (E) POLE.
NEW 5-3/4" SQUARE
WOOD EXTENSION FOR
(E) WOOD UTILITY POLE
15 1" = 1'-0"
CANISTER ANTENNA MOUNTING DETAIL
(P) 6"X6"X6"X1/4"
TUBE STEEL CAP
(2) (P) 5/8" DIA. THRU BOLTS
(P) WAGON WHEEL FOR
13" DIA RADOME
5 1' = 1'-0"
NOTICE SIGNAGE
NOTICE
Transmitting Antenna(s)
Radio frequency fields beyond this point MAY
EXCEED the FCC General Population exposure limit.
Obey all posted signs and site guidelines
Call AT&T Mobility at 1 800-832-6662 PRIOR to
working beyond this point.
STATE:________SWITCH:__________________
SITE ID:_________________________________
SECTOR / NODE: ________________________
MINIMUM APPROACH DISTANCE = 6'-0"
NOTE:
SIGN BACKGROUND COLOR TO MATCH (E) POLE
ALL TEXT AND SYMBOLS TO BE WHITE
MINIMUM APPROACH DISTANCE - 6'
SFOK2_016
4 1" = 1'-0"
WIRE DIAGRAM
CANISTER
ANTENNA
RETRETRETRETCOAX COAX
COAXCOAX COAX
COAXCOAXCOAX(P) (4) 1/2"
SUPERFLEX COAX
(P) (4) 1/2"
SUPERFLEX COAX
(P) RET CABLE
COAXCOAXCOAXCOAX
COAXCOAXCOAX
COAXPLAN VIEW
NEW 3/8" C ALUMINUM
CHANNEL, 10" WIDE
NEW 2" SQ. STEEL TUBE OR
ROUND STOCK. 6" MIN. TYP.
OF 4
NEW 1/2"Ø MOUNTING
BOLT PER CABINET
BOLTING PATTERN
NEW UNISTRUT P1000
OR EQUAL (TYP.)- HORIZONTAL
- LENGTH AS REQUIRED PER
CABINET
5/8" Ø ANTI - SPLIT
GALVANIZED THRU BOLT
(TYP.)
EXISTING WOODEN
UTILITY POLE
REQUIREDVERIFYPERCABINETBOLTINGPATTERN6" MIN
4" MIN
CLEARANCE
PER GO 95(E) 1 1/2" CONDUIT
17 3/4" = 1'-0"
EQUIPMENT MOUNTING DETAIL
(N) 3" COAX CONDUIT
5/8" Ø ANTI - SPLIT
GALVANIZED THRU - BOLT
(TYP.)
NEW 3/8" C ALUMINUM CHANNEL, 6"
WIDE MIN.
NEW 1/2"Ø MOUNTING
BOLT (CONTRACTOR
TO VERIFY WITH
CABINET MFG. SPEC.)
NEW 2" SQ. STL. TUBE
STEEL
11'-0"NOTE:
ALL CABINETS MOUNTED TO UTILITY POLE
SHALL HAVE A MINIMUM TOP & BOTTOM
CLEARANCE OF 7".
ELEVATION VEW
6"1'-0"2'-5"3'-3"3'-4"1'-0"NEW UNISTRUT P 1000
OR EQUAL (TYP.)- HORIZONTAL -
LENGTH AS REQUIRED PER
CABINET 14 1 1/2" = 1'-0"
CONDUIT STRAP DETAIL
(E) WOOD UTILITY POLE
(P) 1/2" DIA. 3" ANTI-SPLIT
LAG SCREW
(P) 2-HOLE GALVANIZED
CONDUIT STRAP
(P) 3" COAX RISER
UPPER BRACKET
STEP
5/8'Ø X10" BOLT AND
LOCKNUT (SUPPLIED)
LOWER BRACKET
STEP
13/16" HOLES FOR
3/4" BOLTS
BRACKET ADAPTER (FOR
POLE TOP DIAMETERS LESS
THAN 8")
EXISTING POLE
EXTENSION BAYONET 5
3/4" SQUARE PRESSURE
TREATED DOUGLAS FIR
BRACKET ASSEMBLY
(SEE DETAIL A)
ANTI- SPLIT BOLT
EXISTING POLE
DETAIL A
BRACKET ASSEMBLY
NOTE:
NEW BRACKET ASSEMBLY
TO BE PROVIDED BY UTILITY
COMPANY
DETAIL B
WOOD EXTENSION
ASSEMBLY
12"
5"
7-1/2"
7-1/2"
7 3/4" = 1'-0"
WOOD POLE EXTENSION
9 3/4" = 1'-0"
ANTENNA EQUIPMENT FRONT ELEVATION
(P) ELECTRIC LOAD CENTER
(P) 2'-0" TELECOMMUNICATIONS
SAFETY ZONE AS PER GO95
(P) PLACE SHUT DOWN PROTOCOLS
ON THE INSIDE COVER OF THE LOAD
CENTER TO BE PROVIDED BY AT&T
(P) GROUND BAR
(P) (2) TWIN DIPLEXERS
(P) 4415 RADIO INSIDE
PROPOSED SOLAR
SHIELD w/ PSU-08
(P) 4426 RADIO INSIDE
PROPOSED SOLAR
SHIELD w/ PSU-08
(P) SMARTPOLE METER
1'-3"9'-0"1'-10"7"6"1'-1"1'-3"1'-1"1'-4"1'-1"2"1 1' = 1'-0"
SHUT DOWN PROTOCOL SIGNAGE
NORMAL SHUT-DOWN PROTOCOLS:
1.CALL (800) 638-2588 NOC 24 HRS. PRIOR TO
SCHEDULE A SHUT-DOWN DAY AND TIME.
2.GIVE NOC THE NODE NUMBER _______________
3.ON SCHEDULED DAY OF SHUT-DOWN, PULL THE
DISCONNECT HANDLE TO THE *OFF* POSITION.
4.CAL NOC WHEN WORK IS COMPLETED.
EMERGENCY SHUT-DOWN PROTOCOLS:
1.CALL NOC (800) 638-2588
2.GIVE NOC THE NODE NUMBER _______________
3.PULL THE DISCONNECT HANDLE TO THE OFF POSITION.
4.CALL NOC WHEN WORK IS COMPLETED.
NOTE:
INSIDE AND OUTSIDE PANEL DOOR SHOWING
SHUT-DOWN PROTOCOL ON 3"X4" LABEL
SHUT DOWN DISCONNECT
1" = 1'-0"
FRONT SIDE
ELEC LOAD CENTER MAKE AND MODEL:
MANUFACTURER: SQUARE D
MODEL: QO612L100RB
DIMENSIONS, HxWxD.in: 12.64" x8.9" x 4.27"
WEIGHT: 9.7 lbs
MOUNTING
BRACKET FOR (P)
EQUIPMENT
ELEC LOAD CENTER
8.9"
TOP
12.64"4.27"
NOTE:
RF SHUTDOWN SIGNAGE TO BE ON THE
INSIDE AND OUTSIDE OF THE LOAD CENTER
3 1 1/2" = 1'-0"
CANISTER ANTENNA
9.45"
ANTENNA =CANISTER
WEIGHT =33.1 LBS
CONNECTOR =10 X 4.3-10 DIN (FEMALE) / BOTTOM
DIMENSIONS =9.45"(DIA.) X 23.63"23.63"16 3" = 1'-0"
SMART POLE METER DETAIL
NOTES:
1.PG&E CODE #M241490 & #M241572
2.PG&E TO PERFORM RF SIGNAL TEST.
3.INSTALL IN STRICT ACCODANCE WITH PG&E UTILITY
BULLETIN FOR SMARTPOLE METER SERVICE
PG&E SMARTPOLE METER DIMENSIONS:
DIAMETER:+/- 4.63"
HEIGHT:+/- 7.17"
WEIGHT:+/- 12 LBS
7.17"4.18"4.11"
4.63"4.12"3 POLE, 3 WIRE
LOCKING
RECEPTACLE
NEMA 3R
ENCLOSURE
BOX
A-4.1
DETAILS
Plot Date:6/12/2019 8:52:28 AM File NameT:\2016\T-16509_Modus_SF_CRAN_AT&T\SFOK2_016-85\SFOK2_016\Sheets\Building A\A-4.1 Details.dwg Plotted By:Brendan McNulty1478 STONE POINT DRIVE, SUITE 350
ROSEVILLE CA 95661
TEL
FAX
borgesarch.com
916 782 7200
916 773 3037
SHEET NO.
SHEET TITLE
DRAWN BY: A.P.E.
CHECK BY: B.P.M.
PROJECT NO.: T-16509-85
STAMP
REV DESCRIPTIONDATE
240 STOCKTON STREET, 3RD FLOOR
SAN FRANCISCO, CA 94108
modus-corp.com
5001 EXECUTIVE PARKWAY
SAN RAMON, CA 94583
No. C11535
0 09/13/17 90% CD Submittal
SITE NUMBER:
SFOK2_016
SITE ADDRESS:
1480 BROADWAY
BURLINGAME, CA, 94010
1 09/25/17 100% CD Submittal
2 02/22/18 100% CD Rev 1
3 06/11/19 100% CD Rev 2
1 1 1/2" = 1'-0"
RRUS 4415
ERICSSON RRUS-4415 REMOTE RADIO UNIT
COLOR:WHITE
DIMENSIONS:14.96" TALL X 13.19" WIDE X 5.39" DEEP (INCLUDING SUNSHIELD)
VOLUME:0.6155 CU. FT.
WEIGHT:+/- 44.0 LBS. (EXCLUDING MOUNTING HARDWARE)
SIDE VIEW
MFR'S STANDARD MOUNTING BRACKETS
TOP VIEW
MFR'S STANDARD
MOUNTING
BRACKETS
SUNSHIELD
RRUS WITH SUNSHIELD
12" CLR.16" CLR.FRONT VIEW
MOUNTING POLE
14.965.3913.19"
5 1 1/2" = 1'-0"
RRUS 4426
ERICSSON RRUS 4426 REMOTE RADIO UNIT
COLOR:WHITE
DIMENSIONS:14.9" TALL X 13.19" WIDE X 5.8" DEEP (INCLUDING SUNSHIELD)
WIEGHT:+/- 48.5 LBS. (EXCLUDING MOUNTING HARDWARE)
SIDE VIEW
PSU-08
TOP VIEW
P1000 UNISTRUT
PSU-08
SUNSHIELD
RRUS WITH SUNSHIELD
12" CLR.16" CLR.FRONT VIEW
MOUNTING CHANNEL
5.8
14.9613.19
Plot Date:6/12/2019 8:52:52 AM File NameT:\2016\T-16509_Modus_SF_CRAN_AT&T\SFOK2_016-85\SFOK2_016\Sheets\Building A\A-4.2 Details.dwg Plotted By:Brendan McNulty1478 STONE POINT DRIVE, SUITE 350
ROSEVILLE CA 95661
TEL
FAX
borgesarch.com
916 782 7200
916 773 3037
SHEET NO.
SHEET TITLE
DRAWN BY: A.P.E.
CHECK BY: B.P.M.
PROJECT NO.: T-16509-85
STAMP
REV DESCRIPTIONDATE
240 STOCKTON STREET, 3RD FLOOR
SAN FRANCISCO, CA 94108
modus-corp.com
5001 EXECUTIVE PARKWAY
SAN RAMON, CA 94583
No. C11535
0 09/13/17 90% CD Submittal
SITE NUMBER:
SFOK2_016
SITE ADDRESS:
1480 BROADWAY
BURLINGAME, CA, 94010
1 09/25/17 100% CD Submittal
2 02/22/18 100% CD Rev 1
3 06/11/19 100% CD Rev 2
A-4.2
DETAILS
EMERGENCY SHUTDOWN
DISCONNECT SWITCH LOCATED
ABOVE ELECTRIC LOAD CENTER 3"4"
NOTE:
NEW VINYL SIGN TO BE PROVIDED BY AT&T AND BE LOCATED ON
THE SIDE OF THE METER BOX. SIGN TO BE YELLOW.
4 NOT TO SCALE
SHUTDOWN DISCONNECT SIGNAGE
Plot Date:6/12/2019 8:53:07 AM File NameT:\2016\T-16509_Modus_SF_CRAN_AT&T\SFOK2_016-85\SFOK2_016\Sheets\Building A\E-1 SINGLE LINE DIAGRAM & PANEL SCHEDULE.dwg Plotted By:Brendan McNulty1478 STONE POINT DRIVE, SUITE 350
ROSEVILLE CA 95661
TEL
FAX
borgesarch.com
916 782 7200
916 773 3037
SHEET NO.
SHEET TITLE
DRAWN BY: A.P.E.
CHECK BY: B.P.M.
PROJECT NO.: T-16509-85
STAMP
REV DESCRIPTIONDATE
240 STOCKTON STREET, 3RD FLOOR
SAN FRANCISCO, CA 94108
modus-corp.com
5001 EXECUTIVE PARKWAY
SAN RAMON, CA 94583
No. C11535
0 09/13/17 90% CD Submittal
SITE NUMBER:
SFOK2_016
SITE ADDRESS:
1480 BROADWAY
BURLINGAME, CA, 94010
1 09/25/17 100% CD Submittal
2 02/22/18 100% CD Rev 1
3 06/11/19 100% CD Rev 2
E-1
SINGLE LINE
DIAGRAM & PANEL
SCHEDULE
ELECTRICAL NOTES
GENERAL REQUIREMENTS:
1. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE LATEST RULES AND
REGULATIONS OF THE NATIONAL ELECTRICAL CODE AND ALL STATE AND LOCAL CODES.
NOTHING IN THESE PLANS OR SPECIFICATIONS SHALL BE CONSTRUED AS TO PERMIT
WORK NOT CONFORMING TO THE MOST STRINGENT OF THESE CODES. SHOULD
CHANGES BE NECESSARY IN THE DRAWINGS OR SPECIFICATIONS TO MAKE THE WORK
COMPLY WITH THESE REQUIREMENTS, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE
ARCHITECT IN WRITING AND CEASE WORK ON PARTS OF THE CONTRACT WHICH ARE
AFFECTED.
2. THE CONTRACTOR SHALL MAKE A SITE VISIT PRIOR TO BIDDING AND CONSTRUCTION TO
VERIFY ALL EXISTING CONDITIONS AND SHALL NOTIFY ARCHITECT IMMEDIATELY UPON
DISCOVERY OF ANY DISCREPANCIES. THE CONTRACTOR ASSUMES ALL LIABILITY FOR
FAILURE TO COMPLY WITH THIS PROVISION.
3. THE EXTENT OF THE WORK IS INDICATED BY THE DRAWINGS, SCHEDULES, AND
SPECIFICATIONS AND IS SUBJECT TO THE TERMS AND CONDITIONS OF THE CONTRACT.
THE WORK SHALL CONSIST OF FURNISHING ALL LABOR, EQUIPMENT, MATERIALS, AND
SUPPLIES NECESSARY FOR A COMPLETE AND OPERATIONAL ELECTRICAL SYSTEM. THE
WORK SHALL ALSO INCLUDE THE COMPLETION OF ALL ELECTRICAL WORK NOT
MENTIONED OR SHOWN WHICH IS NECESSARY FOR SUCCESSFUL OPERATION OF ALL
SYSTEMS.
4. THE CONTRACTOR SHALL PREPARE A BID FOR A COMPLETE AND OPERATIONAL SYSTEM,
WHICH INCLUDES THE COST FOR MATERIAL AND LABOR.
5. WORKMANSHIP AND NEAT APPEARANCE SHALL BE AS IMPORTANT AS THE OPERATION.
DEFECTIVE OR DAMAGED MATERIALS SHALL BE REPLACED OR REPAIRED PRIOR TO FINAL
ACCEPTANCE IN A MANNER ACCEPTABLE TO OWNER AND ENGINEER.
6. COMPLETE THE ENTIRE INSTALLATION AS SOON AS THE PROGRESS OF THE WORK WILL
PERMIT. ARRANGE ANY OUTAGE OF SERVICE WITH THE OWNER AND BUILDING
MANAGER IN ADVANCE. MINIMIZE DOWNTIME ON THE BUILDING ELECTRICAL SYSTEM.
7. THE ENTIRE ELECTRICAL SYSTEM INSTALLED UNDER THIS CONTRACT SHALL BE DELIVERED IN
PROPER WORKING ORDER. REPLACE, WITHOUT ADDITIONAL COST TO THE OWNER, ANY
DEFECTIVE MATERIAL AND EQUIPMENT WITHIN ONE YEAR FROM THE DATE OF FINAL
ACCEPTANCE.
8. ANY ERROR, OMISSION OR DESIGN DESCREPANCY ON THE DRWINGS SHALL BE BROUGHT
TO THE ATTENTION OF THE ENGINEER FOR CLARIFICATION OR CORRECTION BEFORE
CONSTRUCTION.
9. "PROVIDE" INDICATES THAT ALL ITEMS ARE TO BE FURNISHED, INSTALLED AND
CONNECTED IN PLACE.
10. CONTRACTOR SHALL SECURE ALL NECESSARY BUILDING PERMITS AND PAY ALL
REQUIRED FEES.
EQUIPMENT LOCATION:
1. THE DRAWINGS INDICATE DIAGRAMMATICALLY THE DESIRED LOCATIONS OR
ARRANGEMENTS OF CONDUIT RUNS, OUTLETS, EQUIPMENT, ETC., AND ARE TO BE
FOLLOWED AS CLOSELY AS POSSIBLE. PROPER JUDGEMENT MUST BE EXERCISED IN
EXECUTING THE WORK SO AS TO SECURE THE BEST POSSIBLE INSTALLATION IN THE
AVAILABLE SPACE LIMITATIONS OR INTERFERENCE OF STRUCTURE CONDITIONS
ENCOUNTERED.
2. IN THE EVENT CHANGES IN THE INDICATED LOCATIONS OR ARRANGEMENTS ARE
NECESSARY, DUE TO FIELD CONDITIONS IN THE BUILDING CONSTRUCTION OR
REARRANGEMENT OF FURNISHINGS OR EQUIPMENT, SUCH CHANGES SHALL BE MADE
WITHOUT COST, PROVIDING THE CHANGE IS ORDERED BEFORE THE CONDUIT RUNS, ETC.,
AND WORK DIRECTLY CONNECTED TO THE SAME IS INSTALLED AND NO EXTRA MATERIALS
ARE REQUIRED.
3. LIGHTING FIXTURES ARE SHOWN IN THEIR APPROXIMATE LOCATIONS ONLY. COORDINATE
THE FIXTURE LOCATION WITH MECHANICAL EQUIPMENT TO AVOID INTERFERENCE.
4. COORDINATE THE WORK OF THIS SECTION WITH THAT OF ALL OTHER TRADES, WHERE
CONFLICTS OCCUR, CONSULT WITH THE RESPECTIVE CONTRACTOR AND COME TO
AGREEMENT AS TO CHANGES NECESSARY, OBTAIN WRITTEN ACCEPTANCE FROM
ENGINEER FOR THE PROPOSED CHANGES BEFORE PROCEEDING.
SHOP DRAWINGS:
1. N/A UNLESS NOTED OTHERWISE.
SUBSTITUTIONS:
1. NO SUBSTITUTIONS ARE ALLOWED
TESTS:
1. BEFORE FINAL ACCEPTANCE OF WORK, THE CONTRACTOR SHALL INSURE THAT ALL
EQUIPMENT, SYSTEMS, FIXTURES, ETC., ARE WORKING SATISFACTORILY AND TO THE INTENT
OF THE DRAWINGS.
PERMITS:
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR TAKING OUT AND PAYING FOR ALL
REQUIRED PERMITS, INSPECTION AND EXAMINATION WITHOUT ADDITIONAL EXPENSE TO
THE OWNER.
GROUNDING:
1. THE CONTRACTOR SHALL PROVIDE A COMPLETE, AND APPROVED GROUNDING SYSTEM
INCLUDING ELECTRODES, ELECTRODE CONDUCTOR, BONDING CONDUCTORS, AND
EQUIPMENT CONDUCTORS AS REQUIRED BY ARTICLE 250 OF THE NATIONAL ELECTRICAL
CODE.
2. CONDUITS CONNECTED TO EQUIPMENT AND DEVICES SHALL BE METALICALY JOINED
TOGETHER TO PROVIDE EFFECTIVE ELECTRICAL CONTINUITY.
3. FEEDERS AND BRANCH CIRCUIT WIRING INSTALLED IN A NONMETALLIC CONDUIT SHALL
INCLUDE A CODE SIZED GROUNDING CONDUCTOR HAVING GREEN INSULATION. THE
GROUND CONDUCTOR SHALL BE PROPERLY CONNECTED AT BOTH ENDS TO MAINTAIN
ELECTRICAL CONTINUITY.
4. REFER TO GROUND BUS DETAILS. PROVIDE NEW GROUND SYSTEM COMPLETE WITH
CONDUCTORS, GROUND ROD AND DESCRIBED TERMINATIONS.
5. ALL GROUNDING CONDUCTORS SHALL BE SOLID TINNED COPPER AND ANNEALED #2
UNLESS NOTED OTHERWISE.
6. ALL NON-DIRECT BURIED TELEPHONE EQUIPMENT GROUND CONDUCTORS SHALL BE #2
STRANDED THHN (GREEN) INSULATION.
7. ALL GROUND CONNECTIONS SHALL BE MADE WITH "HYGROUND" COMPRESSION SYSTEM
BURNDY CONNECTORS EXCEPT WHERE NOTED OTHERWISE.
8. PAINT AT ALL GROUND CONNECTIONS SHALL BE REMOVED.
9. GROUNDING SYSTEM RESISTANCE SHALL NOT EXCEED 5 OHMS. IF THE RESISTANCE VALUE
IS EXCEEDED, NOTIFY THE OWNER FOR FUTURE INSTRUCTION ON METHODS FOR
REDUCING THE RESISTANCE VALUE. SUBMIT TEST REPORTS AND FURNISH TO SMART SMR
ONE COMPLETE SET OF PRINTS SHOWING "INSTALLED WORK".
UTILITY SERVICE:
1. TELEPHONE AND ELECTRICAL METERING FACILITIES SHALL CONFORM TO THE
REQUIREMENTS OF THE SERVING UTILITY COMPANIES. CONTRACTOR SHALL VERIFY
SERVICE LOCATIONS AND REQUIREMENTS. SERVICE INFORMATION WILL BE FURNISHED BY
THE SERVING UTILITIES.
2. CONFORM TO ALL REQUIREMENTS OF THE SERVING UTILITY COMPANIES.
PRODUCTS:
1. ALL MATERIALS SHALL BE NEW, CONFORMING WITH NEC, ANSI, NEMA, AND THEY SHALL
BE U.L. LISTED AND LABELED.
2. CONDUIT:
A) RIGID CONDUIT SHALL BE U.L. LABEL GALVANIZED ZINC COATED WITH ZINC
INTERIOR AND SHALL BE USED WHEN INSTALLED IN OR UNDER CONCRETE SLABS,
IN CONTACT WITH THE EARTH, UNDER PUBLIC ROADWAYS, IN MASONRY WALLS
OR EXPOSED ON BUILDING EXTERIOR, RIGID CONDUIT IN CONTACT WITH EARTH
SHALL BE 1/2 LAPPED WRAPPED WITH HUNTS WRAP PROCESS NO. 3.
B) ELECTRICAL METALLIC TUBING SHALL U.L. LABEL, FITTINGS SHALL BE
COMPRESSION TYPE. EMT SHALL BE USED ONLY FOR INTERIOR RUNS.
C) FLEXIBLE METALLIC CONDUIT SHALL HAVE U.L. LISTED LABEL AND MAY BE USED
WHERE PERMITTED BY CODE. FITTINGS SHALL BE "JAKE" OR "SQUEEZE" TYPE. SEAL
TIGHT FLEXIBLE CONDUIT. ALL CONDUIT EXCESS OF SIX FEET IN LENGTH SHALL
HAVE FULL SIZE GROUND WIRE.
D) CONDUIT RUNS MAY BE SURFACE MOUNTED IN CEILING OR WALLS UNLESS
INDICATED OTHERWISE. CONDUIT INDICATED SHALL RUN PARALLEL OR AT RIGHT
ANGLES TO CEILING, FLOOR OR BEAMS. VERIFY EXACT ROUTING OF ALL
EXPOSED CONDUIT WITH ARCHITECT PRIOR TO INSTALLING.
E) ALL UNDERGROUND CONDUITS SHALL BE PVC SCHEDULE 40 (UNLEES NOTED
OTHERWISE) AT A MINIMUM DEPTH OF 24" BELOW GRADE
F) ALL CONDUIT ONLY (C.O.) SHALL HAVE PULL ROPE.
G) CONDUITS RUN ON ROOFS SHALL BE INSTALLED ON 4x4 REDWOOD SLEEPERS,
6'-0" ON CENTER, SET IN NON-HARDENING MASTIC.
3. ALL WIRE AND CABLE SHALL BE COPPER, 600 VOLT, #12 AWG MINIMUM UNLESS
SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. CONDUCTORS #10 AWG AND
SMALLER SHALL BE SOLID. CONDUCTORS #8 AWG AND LARGER SHALL BE STRANDED.
TYPE THHN INSULATION USED UNLESS CONDUCTORS INSTALLED IN CONDUIT EXPOSED TO
WEATHER, IN WHICH CASE TYPE THWN INSULATION SHALL BE USED.
4. PROVIDE GALVANIZED COATED STEEL BOXES AND ACCESSORIES SIZED PER CODE TO
ACCOMMODATE ALL DEVICES AND WIRING.
5. DUPLEX RECEPTACLES SHALL BE SPECIFICATION GRADE WITH WHITE FINISH (UNLESS
NOTED BY ENGINEER), 20 AMP, 125 VOLT, THREE WIRE GROUNDING TYPE, NEMA 5-20R.
MOUNT RECEPTACLE AT +12" ABOVE FINISHED FLOOR UNLESS OTHERWISE INDICATED ON
DRAWINGS OR IN DETAILS. WEATHERPROOF RECEPTACLES SHALL BE GROUND FAULT
INTERRUPTER TYPE WITH SIERRA #WPD-8 LIFT COVERPLATES.
6. TOGGLE SWITCHES SHALL BE 20 AMP, 120 VOLT AC, SPECIFICATION GRADE WHITE
(UNLESS NOTED OTHERWISE) FINISH. MOUNT SWITCHES AT +48" ABOVE FINISHED FLOOR.
7. PANELBOARDS SHALL BE DEAD FRONT SAFETY TYPE WITH ANTI-BURN SOLDERLESS
COMPRESSION APPROVED FOR COPPER CONDUCTORS, COPPER BUS BARS, FULL SIZED
NEUTRAL BUS, GROUND BUS AND EQUIPPED WITH QUICK-MAKE QUICK-BREAK BOLT-IN
TYPE THERMAL MAGNETIC CIRCUIT BREAKERS. MOUNT TOP OF THE PANELBOARDS AT
6'-3" ABOVE FINISHED FLOOR. PROVIDE TYPE WRITTEN CIRCUIT DIRECTORY.
8. ALL CIRCUIT BREAKERS, MAGNETIC STARTERS AND OTHER ELECTRICAL EQUIPMENT SHALL
HAVE AN INTERRUPTING RATING NOT LESS THAN MAXIMUM SHORT CIRCUIT CURRENT TO
WHICH THEY MAY BE SUBJECTED.
9. GROUND RODS SHALL BE COPPER CLAD STEEL, 5/8" ROUND AND 10' LONG.
COPPERWELD OR APPROVED EQUAL.
INSTALLATION:
1. PROVIDE SUPPORTING DEVICES FOR ALL ELECTRICAL EQUIPMENT, FIXTURES, BOXES,
PANEL, ETC., SUPPORT LUMINARIES FROM UNDERSIDE OF STRUCTURAL CEILING,
EQUIPMENT SHALL BE BRACED TO WITHSTAND HORIZONTAL FORCES IN ACCORDANCE
WITH STATE AND LOCAL CODE REQUIREMENTS. PROVIDE PRIOR ALIGNMENT AND
LEVELING OF ALL DEVICES AND FIXTURES.
2. CUTTING, PATCHING, CHASES, OPENINGS: PROVIDE LAYOUT IN ADVANCE TO ELIMINATE
UNNECESSARY CUTTING OR DRILLING OF WALLS, FLOORS CEILINGS, AND ROOFS. ANY
DAMAGE TO BUILDING STRUCTURE OR EQUIPMENT SHALL BE REPAIRED BY THE
CONTRACTOR. OBTAIN PERMISSION FROM THE ENGINEER BEFORE CORING.
3. IN DRILLING HOLES INTO CONCRETE WHETHER FOR FASTENING OR ANCHORING
PURPOSES, OR PENETRATIONS THROUGH THE FLOOR FOR CONDUIT RUNS, PIPE RUNS,
ETC., IT MUST BE CLEARLY UNDERSTOOD THAT TENDONS AND/OR REINFORCING STEEL
WILL NOT BE DRILLED INTO, CUT OR DAMAED UNDER THE CIRCUMSTANCES.
4. LOCATION OF TENDONS AND/OR REINFORCING STEEL ARE NOT DEFINITELY KNOWN AND
THEREFORE, MUST BE SEARCHED FOR BY APPROPRIATE METHODS AND EQUIPMENT VIA
X-RAY OR OTHER DEVICES THAT CAN ACCURATELY LOCATE THE REINFORCING AND/OR
STEEL TENDONS.
5. PENETRATIONS IN FIRE RATED WALLS SHALL BE FIRE STOPPED IN ACCORDANCE WITH THE
REQUIREMENTS OF THE C.B.C.
PROJECT CLOSEOUT:
1. UPON COMPLETION OF WORK, CONDUCT CONTINUITY, SHORT CIRCUIT, AND FALL
POTENTIAL GROUNDING TESTS FOR APPROVAL. SUBMIT TEST REPORTS TO PROJECT
MANAGER. CLEAN PREMISES OF ALLS DEBRIS RESULTING FROM WORK AND LEAVE WORK
IN A COMPLETE AND UNDAMAGED CONDITION.
2. PROVIDE PROJECT MANAGER WITH ONE SET OF COMPLETE ELECTRICAL "AS INSTALLED"
DRAWINGS AT THE COMPLETION OF THE JOB, SHOWING ACTUAL DIMENSIONS,
ROUTINGS AND CIRCUITS.
3. ALL BROCHURES, OPERATING MANUALS, CATALOG, SHOP DRAWINGS, ETC., SHALL BE
TURNED OVER TO OWNER AT JOB COMPLETION.
GROUNDING NOTES:
1. ALL DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL GROUNDING INSTALLATION
REQUIREMENTS AND CONSTRUCTION ACCORDING TO SITE CONDITIONS.
2. ALL GROUNDING CONDUCTORS: #2 AWG SOLID BARE TINNED COPPER WIRE UNLESS
OTHERWISE NOTED.
3. GROUND BAR LOCATED IN BASE OF EQUIPMENT WILL BE PROVIDED, FURNISHED AND
INSTALLED BY THE VENDOR.
4. ALL BELOW GRADE CONNECTIONS: EXOTHERMIC WELD TYPE, ABOVE GRADE
CONNECTIONS: EXOTHERMIC WELD TYPE.
5. GROUND RING SHALL BE LOCATED A MINIMUM OF 24" BELOW GRADE OR 6" MINIMUM
BELOW THE FROST LINE.
6. INSTALL GROUND CONDUCTORS AND GROUND ROD MINIMUM OF 1'-0" FROM
EQUIPMENT CONCRETE SLAB, SPREAD FOOTING, OR FENCE.
7. EXOTHERMIC WELD GROUND CONNECTION TO FENCE POST: TREAT WITH A COLD
GALVANIZED SPRAY.
8. GROUND BARS:
A) EQUIPMENT GROUND BUS BAR (EGB) LOCATED AT THE BOTTOM OF ANTENNA
POLE/MAST FOR MAKING GROUNDING JUMPER CONNECTIONS TO COAX
FEEDER CABLES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL
CONTRACTOR. JUMPERS (FURNISHED BY OWNERS) SHALL BE INSTALLED AND
CONNECTED BY ELECTRICAL CONTRACTOR.
9. ALL GROUNDING INSTALLATIONS AND CONNECTIONS SHALL BE MADE BY ELECTRICAL
CONTRACTOR.
10. OBSERVE N.E.C. AND LOCAL UTILITY REQUIREMENTS FOR ELECTRICAL SERVICE
GROUNDING.
11. GROUNDING ATTACHMENT TO TOWER SHALL BE AS PER MANUFACTURER'S
RECOMMENDATIONS OR AT GROUNDING POINTS PROVIDED (2 MINIMUM).
12. IF EQUIPMENT IS IN A C.L. FENCE ENCLOSURE, GROUND ONLY CORNER POSTS AND
SUPPORT POSTS OF GATE. IF CHAIN LINK LID IS USED, THEN GROUND LID ALSO.
13. GROUNDING AT PPC CABINET SHALL BE VERTICALLY INSTALLED.
14. ALL GROUNDING FOR ANTENNAS SHALL BE CONNECTED SO THAT IT WILL BY-PASS MAIN
BUSS BAR.
15. ALL EMT RUNS SHALL BE GROUNDED AND HAVE A BUSHING, NO PVC ABOVE GROUND.
16. USE SEPARATE HOLES FOR GROUNDING AT BUSS BAR. NO "DOUBLE-UP" OF LUGS.
17. POWER AND TELCO CABINETS SHALL BE GROUNDED (BONDED) TOGETHER.
18. NO LB'S ALLOWED ON GROUNDING.
19. PROVIDE STAINLESS STEEL CLAMP AND BRASS TAGS ON COAX AT ANTENNAS AND
DOGHOUSE.
5 N.T.S.
ELECTRICAL NOTES
M
(1) 3" C
(2) 4/0 THWN AL
(1) 1/0 AL NEUTRAL
METER
N G
#2 GROUNDING ELECTRODE, #2
BOND TO GROUNDING ROD
UTILITY
DISTRIBUTION PANEL
100 AMP, 1 PHASE, 120/240V AC
6 POSITION LOAD CENTER
N G
30/2
#2 GROUNDING ELECTRODE
CONDUCTOR TO GROUND RING
100/2 - MAIN BREAKER
RG
30/2
RRH RRH
(2) RRH
(1) 4" C
(4) 1/2" COAX
1 1/2" C (3) #3/0, (1) #2 GROUND
1 1/2" C (3) #10, (1) #10 GROUND
1 1/2" C (3) #10, (1) #10 GROUND
ANTENNA
PSU-08PSU-08
NEW 3/8" DIA. HARDWOOD
MOLDING
NEW GALV IRON MOLDING
STAPLE TYP
NEW 1/2" PVC CONDUIT FOR
METER GROUND
6"
MIN
TYP MECHANICAL
CONNECTION
5/8" DIA. X 10'
GROUND ROD
NEW GROUND CONDUCTOR
#2 GREEN COATED SOLID
COPPER WIRE18"GROUND LEGEND
MECHANICAL CONNECTION
EXOTHERMIC CADWELD
TYP 5/8" DIA. X 10' LONG COPPER CLAD GROUND
ROD AT 10' O.C. MAX AND 18" MIN BELOW FINISH GRADE
15 1" = 1'-0"
GROUND DETAIL
EXISTING GRADE
5 1/2" = 1'-0"
GROUNDING PLAN
(P) 5/8" X 10" GROUNDING ROD
(P) CADWELD CONNECTION TYPE "GRI" MOLD
(P) MECHANICAL CONNECTION
(P) #2 GREEN COATED SOLID COPPER
WIRE ENCASED WITHIN WOODEN
MOLDING CONNECTED WITH
GALVANIZED STEEL STRAPS AT 3'-0"
O.C. PER PG& E REQUIREMENTS
(P) ANTENNA GROUND
(P) ANTENNA MAST GROUND
Plot Date:6/12/2019 8:53:29 AM File NameT:\2016\T-16509_Modus_SF_CRAN_AT&T\SFOK2_016-85\SFOK2_016\Sheets\Building A\E-2 POLE GROUND & RISER DIAGRAM & DETAILS.dwg Plotted By:Brendan McNulty1478 STONE POINT DRIVE, SUITE 350
ROSEVILLE CA 95661
TEL
FAX
borgesarch.com
916 782 7200
916 773 3037
SHEET NO.
SHEET TITLE
DRAWN BY: A.P.E.
CHECK BY: B.P.M.
PROJECT NO.: T-16509-85
STAMP
REV DESCRIPTIONDATE
240 STOCKTON STREET, 3RD FLOOR
SAN FRANCISCO, CA 94108
modus-corp.com
5001 EXECUTIVE PARKWAY
SAN RAMON, CA 94583
No. C11535
0 09/13/17 90% CD Submittal
SITE NUMBER:
SFOK2_016
SITE ADDRESS:
1480 BROADWAY
BURLINGAME, CA, 94010
1 09/25/17 100% CD Submittal
2 02/22/18 100% CD Rev 1
3 06/11/19 100% CD Rev 2
E-2
POLE GROUND &