Loading...
HomeMy WebLinkAboutReso - PC - 2021.11.08 - 8BI DocuSign Envelope lD: 1 73F4EE4-1 4EF 4MB-n8B-D598D41 5FE4E RECORDING REQUESTED BY Planning Department City of Burlingame WHEN RECORDED MAIL TO: COMMUNITY DEVELOPMENT DEPARTMENT CIry OF BURLINGAME 501 PRIMROSE ROAD BURLINGAME, CA 94010 2022-A,I4154 1 :25 pm 02116122 R1 Fee: NO FEE Count of Pages 4 Recorded in Official Records CountY of San Mateo Mark Church I lur r l rilfl milfliifiiiliiiiliXfi llnlnlfi]ffinltl tt ttt illi';-$ R- o-o o 3 z 1 4 I o '1 $ * +{Resolution No. 2021-1 1.08.-88 2701 H!LLSIDE DRIVE APN 027-194-010 TITLE OF DOCUMENT I hereby certify this to be a full, true and conect copy of the document it purports to be, the original of which is on file in my office. 7 2022 h*iru hrliwy @dUNE a: Date: Kevin Development Director RESOLUTION APPROVING CATEGORICAL EXEMPTION, DESIGN REVIEW AND SPEGIAL PERMIT RESOLVED, by the Planning commission of the city of Burlingame that: WHEREAS, a Categorical Exemption has been proposed and application has been made for Desion Review and Special Permit for buildinq heiqht for a new. two-storv sinole familv dwellinq and detached qaraoe at 2701 Hillside Drive, zoned R-1: Alain and Mffi owners, APN: 027-1 94-01 0: WHEREAS, said matters were heard by the Planning Commission of the City of Burlingame on November 8, 2021, at which time it reviewed and considered the staff report ind all other written materials and testimony presented at said hearing; NOW, THEREFORE, it is RESOLVED and DETERMINED by this Planning Commission that: 1. lt is hereby found that the project set forth above is Categorically Exempt from environmental review pursuant to the California Environmental Quality nct (CEaA), per Section 15303 (a) of the CEQA Guidelines, which states that construction of a timiied number of new, small facilities or structures, including one single-family residence, or asecond dwelling unit in a residential zone, is exempt from environmental review. ln urbanized areas, this exemption may be applied to the construction or conversion of up to three (3) single-family residences as part of a project. 2. 3 said Design Review and special Permit are approved subject to the in Exhibit "A" attached hereto. Findings for such Design Review and set forth in the staff report, minutes, and recording of said meeting. It is further directed that a certified copy of th records of the County of San Mateo. conditions set forth Special Permit are in the official Secretary ame, do hereby certify that the foregoing regular meeting of the Planning Com mission he following vote: of the Planning Commission of the City of resolution was introduced and adopted at a ld on the 8th dav of November. 2021 by the 2701 HILLS|DE DR - RESO 2021-11.08€BAYES: COMAROTO, GAUL, LARIGS, LOFTIS, SCHUID, TERRONES, TSENOES: NONE ABSENT NONE REGUSED: NONE lutio t, EXHIBIT "A" 1 Conditions of approval for Categorical Exemption, Design Review and Special permit 2701 Hillside Drive Effective November 18, 2021 Page 1 that the project shall be built as shown on the plans submitted to the planning Division date stamped October 6, 2021, sheets A.1 through A.7, N.1, AC, L1.1, L2.1 and topographic survey plan; that any changes to building materials, exterior finishes, windows, architectural features, roof height or pitch, and amount or type of hardscape materials shall be subject to Planning Division or Planning commission review (Fyl or amendment to be determined by Planning staff); 2 ? 4 o that any changes to the size or envelope of the basement, first or second floors, orgarage, which would include adding or enlarging a dormer(s), shall require an amendment to this permit; that any recycling containers, debris boxes or dumpsters for the construction project shall be placed upon the private property, if feasible, as determined by the community Development Director; that demolition for removal of the existing structures and any grading or earth moving onthe site shall not occur until a building permit has been issuet and such site work ihall be required to comply with all the regulations of the Bay Area Air euality Management District; that prior to issuance of a building permit for construction of the project, the project construction plans shall be modified to include a cover sheet listing iI conditions ofapproval adopted by the Planning commisslon, or city council on appeal; which shallremain a part of all sets of approved plans throughout the constiuction process. compliance with all conditions of approval is required; the conditions of approval shallnot be..modified or changed without the approval of the planning commission, or cityCouncil on appeal; that all air.ducts, plumbing vents, and flues shall be combined, where possible, to a single termination and installed on the portions of the roof not visible from the streei; anJthat thes-e venting details shall.be included and approved in the construction iranibefore a Building permit is issued; that the project shall comply with the construction and Demolition Debris Recyclingordinance which requires affected demolition, new construction and atteration pi6ffi to submit a waste Reduction. plan and meet recycling requirements; any parti;l o'ifulldemolition of a structure, interior or exterior, shall requirl a demolition permii; that the project shall meet all the requirements of the california Building and UniformFire codes, in effect at time of buirding permit submittar, as amended ly tne city ofBurlingame; 7 o I EXHIBIT "A" Conditions of approval for Categorical Exemption, Design Review and Special permit 2701 Hillside Drive Effective November 18, 2021 Page 2 THE FOLLOWNG CONDITIONS SHALL BE MET DURING THE BUILDING INSPECTION PROCESS PRIOR TO THE INSPECTIONS NOTED IN EACH CONDITION: 10. that prior to scheduling the framing inspection the applicant shall provide a certification by the project architect or residential designer, or another architect or residential design professional, that demonstrates that the project falls at or below the maximum approved floor area ratio for the property; 12. 13 14. that prior to scheduling the foundation inspection, a licensed surveyor shall locate the property corners, set the building footprint and certify the first floor elevation of the new structure(s) based on the elevation at the top of the form boards per the approved plans; this survey shall be accepted by the City Engineer; that prior to scheduling the framing inspection the project architect or residential designer, or another architect or residential design professional, shall provide an architectural certification that the architectural details shown in the approved design which should be evident at framing, such as window locations and baG, are built isshown on the approved plans; architectural certification documenting framing compliance with approved design shall be submitted to the Building Division before th6 final framing inspection shall be scheduled; that prior to scheduling the roof deck inspection, a licensed surveyor shall shoot the height of the roof ridge and provide certification of that height to th; Building Division; and that prior to final inspection, Planning Division staff will inspect and note compliance of the architectural details (trim materials, window type, etc.) to verify that the pioject has been built according to the approved planning and Building plans. 11. I1'-0'' 51®E 5ETBACK MAIN FLOOR p.N.E. 154.53 = 153.9+155.1(o / T F MFTAI ATTI(•'. n..n r_vvi ii itr_ r-nMG/)alTlnNl LEFT SIDE ELEVATION VIEW FROM (BENITO AVENUE 00 A T U. 1 /AII-11 All TYF. ROOF FITON DIRECT VENT 2 THRU CHIMNEY. � --------------- I J i I i i i i / / / 511)E WALK 2x4 SKYLIGHT —1 5 INGLE ROOFINJC, F—VENT5METAL ATTIC F T, 'F GO, FRONT ELEVATION VIEW FROM (HILLSIDE DRIVE D.H.E. 161.,55 =161 +162.1 152.1 +155.1 2 TOF OF RID6F i TOF FLATE UPPER FLOOR PLATE LEVEL MAIN FLOOR EL. +1(o0.00 REVISIONS BY PLNG P01 08/25/21 PU V W o � O O a 00 00 U O� W �Q Q �DP o QUA 0 3 >w �. c> O 9b W Q O y CIS 03 w o 3 U N 0 Q. o t5 ' U cc3 F— 0 F--i uWW � W � � DATE: MAY 10,21 SCALE: AS NOTED DRAWN: MC JOB: SHEET NO. A04 OF SHEETS i MGTAI ATTIP' Tl'P. ROOF PITCH METAL ATTIC VENTS 12 ALUMINUM CLAD WOOD CASEMENT WINDOW6, DUAL GLAZING TYT>.- STUCCO, TYf. I i IT] QFFU I I W �rrr < N.E. IC 135=161+162.1 I I k I I I T.O.C. 153.6=152.1+155.1 2 COMP051 T I ON SHINGLE ROOFING E R SET5AC A'g l�� EZ ��� FEI ��� T] '01 12" lU0D SAND WOOD FRENCH LIGHT FIXTURE, 51-FOLDING WOOD DOORS 40 WATTS MAX. DOORS CORBELS (E) GRADE (N) GRADE I REAR ELEVATION SCALE.- 1/4"=1'-0" GUTTERS/DOWNSPOUT AND SCUPPER. TYF. \ tp \ �p 10'-0u FRONT SETBACK FROM 5ENITC AVENUE D.N.E. 154.53 = 153.9+155.16 ldf-1ar+l,yL 1'-0'' SIDE SETBACK REVISIONS BY PLNG P01 08/25/21 PU V W � O a 00 00 U O� W �Q Q �DP4 kn QUA 0 I o 3 >w �. c �W-> t,o ��•� U � 2a� c> O y 03 CJU O cd 3 F-� O -•C OU td F� uWW � � O Ilr�l I� ^� I W � � DATE: MAY 10,21 SCALE: AS NOTED DRAWN: MC JOB: SHEET NO. A,95 OF SHEETS CI AT GARAGE DOOR nv WATTS MAX. FRONT ELEVATION SCALE: 1/4"=1'-0" rl AT ---r REAR ELEVATION SCALE: 1/4"=1'-0" FLAT ROOF PLATE LEVEL Lu U SETBACK _Lu El Q GARAGE EL. +154.00 LIGHT FIXTURE, 40 STUCCO TYP, WATTS MAX. (E) 4 (N) GRADE RIGHT SIDE ELEVATION SCALE: 1/4"=1'-0" rl AT ---r LEFT SIDE ELEVATION SCALE: 1/4"=1'-0" N ONE HOUR FIRE -RATED ASSEMBLY EXTERIOR WALLS, SEE DETAIL I00.3, ONE HOUR TREATMENT FOR ANY PORTION OF THE ROOF THAT OVERHANGS AT THESE SAME WALLS NEAR THE PL. 8" RET, WAt L //77 I 1' — 011 SETBACK Lu z f I Lu f PROPERTY LINE - U 15'-2" GLR. w- 1 CAR GARAGE 0010 SECTIONAL GARAGE DOOR, PROVIDE ONE FIXED LOUVER WITHIN 6" OF THE GARAGE FLOOR AND THE AREA OF EACH OPENING SHALL BE 60 50 INCHES MIN. 31-31I 101-01l 31-311 GARAGE FLOOR PLAN SCALE: 1/4"=l'-0" GARAGE ROOF PLAN SCALE: 1/4"=1'-0" r I i REVISIONS BY PLNG P01 08/25/21 PU W o O� O 00 Z a 00 W �pM QUCJI 0 �o 3 un > 141 �. un 9W Q- -sM- CIS03 o o N to C5 O N U t5 110 ul A o o ; t) cc3 O r� O • uWW o W DATE: MAY 10,21 SCALE: AS NOTED DRAWN: MC JOB: SHEET NO. A.6 OF SHEETS GENERAL NOTES: I. SEE LANDSCAPE PLAN FOR DETAIL INFORMATION 2. MAXIMUM DRIVEWAY SLOPES SHALL NOT EXCEED FIFTEEN (15) PERCENT AT ANY POINT WITHOUT SPECIAL APPROVAL OF THE DEPARTMENT OF PUBLIC WORKS± SLOPES IN EXCESS OF TWENTY (20) PERCENT SHALL REQUIRE APPROVAL OF THE PLANNING COMMISSION. TRANSITIONAL SLOPES ARE REQUIRED FOR DRIVEWAYS WHICH EXCEED TEN (10) PERCENT MAXIMUM SLOPE. NO TRANSITIONAL SLOPE SHALL EXTEND INTO A REQUIRED PARKING SPACE, 3, TOPOGRAPHY IS PREPARED BY: QUIET RIVER LAND SERVICES, INC. 6141 SIERRA COURT, SUITE K DUBLIN, GA 94568 TEL: (925) 134-6188 4. A DEMOLITION PERMIT IS REQUIRED FOR SIDEWALK, SEWER AND WATER REPLACEMENT 5. REQUIRED PROTECTIVE FENCING MUST BE INSTALLED AND INSPECTED PRIOR TO DEMO PERMIT ISSUE. 6, SEWER BACKFLOW PROTECTION CERTIFICATE IS REQUIRED PER ORDINANCE O. 1110. A DRAFT CERTIFICATION SHALL BE SUBMITTED PRIOR TO THE ISSUANCE OF A BUILDING PERMIT. 1. THE SURVEYOR RECOMMENDS THE CITY VERIFY THAT THE PERTINENT RESIDENCES WERE USED IN THE CALCULATION. S. GARAGE FOOTING SHALL NOT EXTEND INTO ONE FOOT SETBACK WITHOUT A LICENCED SURVEY AND FIELD STAKING REVIEWED BY INSPECTOR. 9, NEW WATER METER SHALL NOT ON PRIVATE PROPERTY. IT MUCH BE LOCATED ON PUBLIC, PROPERTY FOR ACCESS BY METER READER. 10. NEW SEWER LINE WITH GLEANOUT FOR NEW HOUSE. CLEANOUT AT SEWER MAIN LINE TO BE IN PUBLIC EASEMENT FOR CITY ACCESS. IL CONTRACTOR SHALL ENSURE THE DOUBLE VALE ASSEMBLY FOR FIRE PROTECTION SHALL BE TESTED AND APPROVED BY A SAN MATEO COUNTY ENVIRONMENTAL HEALTH APPROVED CONTRACTOR PRIOR TO SCHEDULING WATER DEPARTMENT FINAL. 12. PROVIDE ADEQUATE FIRE FLOW BASED UPON CONSTRUCTION AND SIZE OF BUILDING , SEE UFG APPENDIX IIIA. MINIMUM 500 GPM REQUIRED, SEE TABLE NO. A-III-A-1. 13, MINIMUM P WATER METER REQUIRED 14, IF BACKWATER PROTECTION IS REQUIRED, CONTRACTOR SHALL PROVIDE AN ISOMETRIC DIAGRAM OF THE BUILDING SEWER INCLUDING ALL BACKWATER VALVES, RELIEF VALVES, AND ANY SEWER INJECTION SYSTEM DETAILS. CITY OF BURLINGAME MUNICIPAL CODE ORDINANCE 1110. 15. PROVIDE SURVEY STAKES PRIOR TO FOUNDATION INSPECTION TO VERIFY LOT LINES. 16. PROVIDE A PRESSURE ABSORBING DEVICES OR APPROVED MECHANICAL DEVICES ARE REQUIRED ON WATER LINES, LOCATED AS GLOBE AS POSSIBLE TO QUICK ACTING VALVES, THAT WILL ABSORB HIGH PRESSURES RESULTING FROM QUICK CLOSING OF QUICK -ACTING VALVES. CPC 5ECTION609.10 RO1-1C WORK NOTES 4 CONDITIONS: I. A REMOVE/REPLACE UTILITIES ENCROACHMENT PERMIT IS REQUIRED: • REPLACE ALL CURB, GUTTER, DRIVEWAY AND SIDEWALK FRONTING SITE. • PLUG ALL EXISTING SANITARY SEWER LATERAL CONNECTIONS AND INSTALL A NEW 6" LATERAL. • ALL WATER LINE CONNECTIONS TO CITYWATER MAINS FOR SERVICES OR FIRE LINE ARE TO BE INSTALLED PER CITY STANDARD PROCEDURES AND SPECIFICATION. • ANY OTHER UNDERGROUND UTILITY WORKS WITHIN CITY'S RIGHT OF WAY. 2. THE SANITARY SEWER LATERAL (BUILDING SEWER) SHALL BE TESTED PER ORDINANCE CODE CHAPTER 15.12. TESTING INFORMATION IS AVAILABLE AT THE BUILDING DEPARTMENT COUNTER. AN ENCROACHMENT PERMIT IS REQUIRED FROM THE PUBLIC WORKS DEPARTMENT WHENEVER THE CITY'S PORTION OF THE SEWER LATERAL OR CITY GLEANOUT IS TO BE LAID AND/OR CONNECTED TO THE SEWER MAINS. 3, SEWER BACKWATER PROTECTION CERTIFICATION IS REQUIRED FOR THE INSTALLATION OF ANY NEW SEWER FIXTURE PER ORDINANCE NO, 1110. THE SEWER BACKWATER PROTECTION CERTIFICATE IS REQUIRED PRIOR TO THE ISSUANCE OF BUILDING PERMIT. 4. ALL WATER LINE CONNECTIONS TO CITY WATER MAINS FOR SERVICES OR FIRE LINE PROTECTION ARE TO BE INSTALLED PER CITY STANDARD PROCEDURES AND MATERIAL SPECIFIGATIONS. CONTACT THE CITY WATER DEPARTMENT FOR CONNECTION FEES. ENCROACHMENT PERMIT IS REQUIRED FOR ANY WORK IN THE CITY'S RIGHT-OF-WAY. 5. A SURVEY BY A LIGENSED SURVEYOR OR ENGINEER IS REQUIRED. THE SURVEY SHALL SHOW HOW THE PROPERTY LINES WERE DETERMINED AO THAT THE PROPERTY GORNERS WERE SET WITH SURVEYORS LICENSE NUMBER50N DURABLE MONUMENTS. THIS SURVEY SHALL BE ATTACHED TO THE CONSTRUCTION PLANS. ALL CORNERS NEED TO BE MAINTAINED OR REINSTALLED BEFORE THE BUILDING FINAL. ALL PROPERTY CORNERS SHALL BE MAINTAINED DURING CONSTRUCTION OR RE-ESTABLISHED AT THE END OF THE PROJECT. 6, ENCROACHMENT PERMIT IS REQUIRED FOR ANY WORK IN THE CITY'S RIGHT-OF-WAY. 1, CONSTRUCTION AND BUILDING USE SHALL CONFORM TO CONDITIONS AS DESGRIBED BY PLANNING COMMISSION AND/OR CITY COUNCIL ACTIONS. S. THE PROJECT SHALL COMPLY WITH THE CITY'S NPDES PERMIT REQUIREMENTS TO PREVENT STORM WATER POLLUTION. 9. NEW DRIVEWAY OR DRIVEWAY WIDENING MUST BE APPROVED BY THE CITY ENGINEER. SHOW DISTANCE BETWEEN THE PROPOSED DRIVEWAY OPENING TO THE CLOSEST ADJACENT DRIVEWAY ON SITE PLAN. 11. NO STORM WATERS, UNDERGROUND WATERS DRAINING FROM ANY LOT, BUILDING, OR PAVED AREAS SHALL BE ALLOWED TO DRAIN TO ADJACENT PROPERTIES NOR SHALL THESE WATERS BE CONNECTED TO THE CITY'S SANITARY SEWER SYSTEM. THESE WATERS SHALL ALL DRAIN TO EITHER ARTIFICIAL OR NATURAL STORM DRAINAGE FACILITIES BY GRAVITY OR PUMPING REGARDLESS OF THE SLOPE OF THE PROPERTY." MUNICIPAL CODE SECTION 18.08.010 (I). • STORM WATER SHALL BE DRAINED THROUGH A CURB DRAIN OR TO THE STORM DRAINAGE SYSTEM. SEE CITY STANDARDS FOR CURB DRAIN DESIGN. • FLOOD ZONE 'C' REQUIRES FLOOD ZONE CONFIRMATION AND/OR PROTECTION OF HABITABLE SPACE. • PROVIDE ELEVATIONS TO CONFIRM DRAINAGE AO SITE DESIGN. 12, NEW DRIVEWAY OR DRIVEWAY WIDENING MUST BE APPROVED BY THE CITY ENGINEER. SHOW DISTANCE BETWEEN THE PROPOSED DRIVEWAY OPENING TO THE CLOSEST ADJACENT DRIVEWAY ON SITE PLAN. DRAINAGE NOTES: I II BUILDING SETBACK: I II ADDRESS FRONT SETBACK 3'-4" �(SITE) �Q, \ REAR 161 SETBACK 213013 21Y 2115 26.2' - TOTAL 43.3' 1�0 o AVERAGE 23.05' LLL LLLL LLL e Irol (W GARAGE \ LANDS OF HASSOUN TRUST PF EL 154.00 LOT ro, E�LOC rod I 5`-O" 22'-2" EASTON ADDTN. TO E�LIRL INCzAME #i 1 FLAT ROOF 1vt - (8 20) 21'-IC'I • Ni'PE�RFT. APN: 021-19,4-020 SLOPE CONCRETE 1327 5ENI70 AVENUE-0F EPAil0.5 SIDE SETBACK DN. j 159 1'=UFFER REAR ETBACK 43'-4" FIRST FLOOR REAk ETBACK \158- I -1 LI 11 LI I U Y \ ,(I - " 398.99' �w BFD DCV FIRE SPRINKLER V DOMESTIC WATER LEGEND: WM - WATER METER V - VALVE DCV - DOUBLE CHEGK VALVE WM MGv - MAIN CONTROL VALVE BPI) - BACK FLOW PREVENTION DEVICE -W- - WATER LINE 1-1/4"0 TYP. 1, PROVIDE A BAGFLOW PREVENTION DEVICE - USG APPROVED DOUBLE CHEGK VALVE ASSEMBLY. 2, CONTRACTOR SHALL ENSURE THE DOUBLE CHEGK VALVE ASSEMBLY FOR THE FIRE PROTECTION SHALL BE TESTED AND APPROVED BY A SAN MATEO COUNTY ENVIRONMENTAL HEALTH APPROVED CONTRACTOR PRIOR TO SCHEDULING WATER DEPARTMENT FINAL. 3, PROVIDE ADEQUATE FIRE FLOW BASED UPON CONSTRUCTION AND SIZE OF BUILDING, SEE UPC APPENDIX IIIA. 5CL4MATIC WATER LATERAL LI NOT TO 5GALE 11'-0" (N) DRIVEWAY APPROACH II \\ �- / 151FO" RETAINING Iro3 1ro2 lrol 1&0159 Ills\ I RIGHT SIDE / 15g TOG r*A WALL 162. I 55.1 I.IL 21 27F11DE FLOOR \ 2x SKYLI T 2 SKYLI T - - I_ JP T� M HILLSID FLAT RooF ����P/ LZ 2tk'4'LOOR FRONT S AC FROM DRIVE r RIDGE I 1 I 5g I I I I 75 p Ct LLI L _J + I I J + + BETE + / 153 , --- I m \ 157+ i A l I _ RE:TAINI`H, E l O O O } + + -- - - - O O O - 55.16+ + ++ -_ I 152.1 \� ----- ---- -- -- --- - --- / I 1 / ( (N) TOSCIIER LEANOAUT \ METER \-\ - ------------------- 0 , 13'-0" UPPER FLOOR LEFT SIDE SETBACK FROM BENITO AVE. 10'-0" FIRST FLOOR LEFT SIDE SETBACK FROM .BERITO AVE 155,02' - - -- BA515 01= B5ARINC-15 N BB°03'Iro" UJ 554,01' (I`-MON.) - - - - - (22 LLS 5e) BENITO AVEN� 50' UJIDE RICaHT-OF-UJAY - - - T�tn1=� NO. I� h1 /=A=1 -_---- MINIMUM REOUIRED FIRE FLOW 4 FLOW DURATION BUI1_DIN 5 FIRE AREA (square feet) FIRE FLOW [gallons FLOW FLOW fV X0.0929 for m2 minute) {hours] Type _F.R. I F.R.1 Type II One-HR. Ill One-HR.1 Type IV-H.T. V-One-Hr.1 Type II-N II-N1 Type V-N1 x 3.785 for Urnin. 0-22,700 0-12,700 M.200 M,900 03,600 1,500 2 22,70130,200 12,701-17,000 8,201-10,900 5,901-7.900 3.601-0,800 1,750 30,20138,700 17.001-21.800 10.901-12,900 7.901-9.800 4.801-6.200 2.000 36,701-48,300 21.801-24,200 12,901-17,400 9,801-12.600 6.201-7,700 2,250 46,301-59,000 24.201-33,200 17,401-21,300 12,601-15,400 7.701-9,400 2,500 59,001-70,900 33,201-39.700 21,301-25,500 15,401-18,400 9,401-11,300 2,750 70,901-83.700 39.701-47,100 25,50130,100 18,401-21,800 11,301-13.400 3,000 3 83,701-97,700 47,101-54,900 30,10135,200 21,801-25.900 13.401-15.800 3,250 97.701.112.700 54.901-63.400 35.201-40,600 25.901-29.300 15.601-18,000 3.500 112,701-128,700 63.401-72,400 40,601-46,400 29,301-33,500 18.001-20,600 3,750 128,701-145,900 72,401-82,100 46,401-5Z500 33,501-37.900 20,601-23,300 4,000 145,901-164,200 82,101-92,400 52,501'�59,100 37,901-42,700 23,361-26,300 4,250 164,201-1;83,400 92.401-103,100 59.101-66,000 42,701-47,700 26.301-29.300 4,500 183,401-203.700 103,101-114,600 56.001-73,300 47.701-53.000 29.301-32,800 4.750 203,701-225,200 114.601-126,700 73,301.81,100 53.001-58.600 32.601-36,000 5,000 225,201-247,700 126,701-139,400 81,101.89,200 58,601-65.400 36,001-39,600 5,260 247 1-271 200 ,70 1 4 1-1 fi 0 39, 0 52, 0 9 201-97 7 8 , 00 fi d 1-7 00 5, 0 0,fi 1-d 4 39,60 3, 00 5,5 00 271,201-295,900 152,601-166,500 97,701-106,5f10 70,601-77,000 43,401-47,400 5,750 4 295,901-Greater 186,601-Greater 106,501-115.800 77,001-83,700 47,401-51,500 6,000 " 115.801-125.500 83.701-90.600 51.501-55,700 5.250 " 125,501-136,500 90.601-97.900 55.701-60,200 6,500 ^ " 135,501-145,800 97,901-106,800 60.201-64,800 6,750 " 145,801-156,700 106,801-113,200 64,801.69,600 7,000 " 156,701-167.900 113,201-121,300 69.601-74.800 7,250 " 187,801-178,400 121,301-129,600 74,601-78,800 7,500 " 179,401-191,400 129,fi01-138,300 79,801-85,100 7,750 " 191,401-Greater 128,301-Greater 85,101-Greater 8,000 RAINWATER COLLECTION ALL NEW ROOF RAINWATER SHALL BE GOLLECTED BY MEANS OF GALVANIZED METAL GUTTERS, UNLESS NOTED OTHERWISE, FIRE NOTES: LOCATED AT THE EAVES. PAINT TO MATCH COLOR SCHEME OF RESIDENCE. GUTTER SHALL LEAD TO 2" X 4" RECTANGULAR METAL DOWNSPOUTS OR DOWNSPOUTS TO MATCH EXISTING AND/OR COPPER RAINWATER LEADER. DOWNSPOUTS SHALL CONTRACTOR SHALL OBTAIN S A AT FIRE SPRINKLER MIT FOR THE INSTALLATION OF THE FIRE S INK SYST M IN ACCORDANCE WITH SECTION IT.04.030 OF TH R R LL B EP R E RE PR LER PER R E LL E RE PR LER E RD E E E TERMINATE BELOW GRADE TO A PERIMETER 4 DIAMETER ABS SOLID DRAINPIPE. RUN 4 DIAMETER (OR SIZE AS NOTED ON MUNICIPAL CODE. THE MINIMUM SI SERVICE FOR FIRE SPRINKLER SYST M SHALL GONFO MS TO NF A 13 O 13 IS 2 . FOR NF A 13 SYST MS THE MINIMUM SI IS I BURLINGAME P L DE E ZE ER E R RE PR LER E LL R P R R R P D E E ZE SITE PLAN) SOLO PIPE THROUGH FACE OF CURB SO THAT WATER WILL EMPTY INTO THE STREET GUTTER SYSTEM. SLOPE ALL PIPES FOR ADEQUATE DRAINAGE. INSURE THAT THE LOCATION CHOSEN FOR THE PIPE TO GO THROUGH THE FACE OF CURB IS FIRE SPRINKLER SHOP DRAWINGS ARE TO BE SUBMITTED DIRECTLY TO THE BURLINGAME FIRE DEPARTMENT AT 1399 ROLLINS ROAD, BURLINGAME ONLY AFTER FIRE SPRINKLER ADEQUATE TO CARRY THE WATER FROM THE SITE TO A CITY MAINTAINED WATER COLLECTION SYSTEM. IN SINGLE-FAMILY UNDERGROUNDS HAVE BEEN SUBMITTED TO THE BURLINGAME BUILDING DEPARTMENT. RESIDENCES THE WATER MAY FLOW TO THE STREET BY GRAVITY METHOD PROVIDED THERE IS SUFFICIENT GRADE TO INSURE RN �V�� INS NOT: FLOW TO THE STREET GUTTER AND THAT WATER DOES NOT FLOW ONTO ADJOINING PROPERTIES. I. OJ CTS THAT ISTU SS THAN ON AG SHALL DEVELOP AN IMPLEMENT A AN TO MANAGE STORM WATER DRAINAGE DURING GONST UCTION. A M AG IS PR E D RB LE E RE LL DE EL P DPLAN GE R ER DR E D R R B P PAGE SUMP PUMP MAY BE REQUIRED (SEE SITE PLAN) SUFFICIENT. IF THE GRAVITY METHOD OF DRAINAGE CANNOT BE USED, PROVIDE A SUMP PUMP OF ADEQUATE SIZE TO CARRY ALL WATER THROUGH A 2" DIAMETER ABS PIPE THROUGH THE FACE OF THE CURB SO THAT THE WATER WILL EMPTY INTO THE GUTTER 2. PLANS SHALL INDICATE HOW GRADING AND PAVING WILL PREVENT SURFACE WATER FLOWS FROM ENTERING BUILDINGS. EXCEPTION: PROJECTS THAT DO NOT ALTER DRAINAGE SYSTEM. INSURE THAT THE LOCATION CHOSEN FOR THE PIPE TO GO THROUGH THE FACE OF CURB IS ADEQUATE TO CARRY THE PATH WATER FROM THE SITE TO A CITY MAINTAINED WATER COLLECTION SYSTEM. 3, ELECTRIC VEHICLE (EV) CHARGING, PARKING SPACES: COMPLY WITH ALL RELEVANT SECTIONS. PROVIDE A BACKFLOW PREVENTER/DEVICE AT A LOCATION NEAR THE TERMINATION OF THE SOLID PIPE THROUGH THE FACE OF CURB AS REQUIRED TO PREVENT RAINWATER FROM THE GUTTER SYSTEM ENTERING THE SUMP PUMP SYSTEM. SITE NOTE,5: SUMP PUMP AT A MINIMUM SHALL BE A 1/4 HP AUTOMATIC SUBMERSIBLE SUMP PUMP WITH PERFORMANCES AS LISTED BELOW 1. EXTERIOR BEARING WALLS LESS THAN 5 FEET FROM THE PROPERTY LINE WILL BE BUILT OF 1-HR FIRE RATED CONSTRUCTION. 2019 CBC TABLE 602, (MINIMUM). INSTALL AS PER MANUFACTURERS SPECIFICATIONS AND RECOMMENDATIONS. 2. ROOF EAVES WILL NOT PROJECT WITHIN 2 FEET OF THE PROPERTY LINE. DISCHARGE FEET OF HEAD 5 10 15 PERFORMANCE (GALLONS PER HOUR) 2200 1620 660 3. NO EXISTING TREE OVER 40 INCHES IN CIRCUMFERENCE AT 54 INCHES FORM BASE OF TREE MAY BE REMOVED WITHOUT A PROTECTED TREE REMOVAL PERMIT FROM THE PA S DIVISION. SUMP PIT- INSTALL PUMP IN SUMP PIT (CATCH BASIN) WITH THE MINIMUM CLEARANCES AND DEPTHS AS PER MANUFACTURER SPECIFICATIONS AND RECOMMENDATIONS. 4. NO PERMANENT STRUCTURES (RETAINING WALLS, FENCES, COLUMNS, MAILBOX, ETC.,) PROPOSED BEYOND THE PROPERTY LINE AND INTO THE PUBLIC RIGHT-OF-WAY. 5. NEW WOOD ROOFING MATERIAL WILL HAVE A MINIMUM CLASS B FIRE RATING. 5CCI-02 PROPOSED SITE PLAN SCALE: 1/8'=1'-0" N WILDING NOTES: 1. BASED ON THE SCOPE OF WORK, THIS PROJECT IS GONSIDERED A "TYPE i" PROJECT THAT REQUIRES A STORM WATER CONSTRUCTION POLLUTION PREVENTION PERMIT. NOTE: THIS PERMIT IS REQUIRED TO BE OBTAINED BY THE PUBLIC WORKS DEPARTMENT PRIOR TO THE ISSUANCE OF A BUILDING PERMIT. IN ADDITION, AN INITIAL FIELD INSPECTION BY THE PUBLIC WORKS INSPECTOR IS REQUIRED PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION WORK ON PRIVATE PROPERTY OR IN THE PUBLIG RIGHT-OF-WAY. 2. PUBLIC WORKS REQUIRE A SEWER BACKWATER PROTECTION CERTIFICATE PRIOR TO PERMIT BEING ISSUED. OWNER TO CONTACT PRIOR TO BUILDING PERMIT ISSUANCE, 3, DEMOLITION OF A STRUCTURE REQUIRE THE OWNER TO OBTAIN A PERMIT FROM BAAQMD AND REQUIRE SIGN -OFFS FROM THE WATER, SEWER, AND PLANNING AND RECYCLING DEPARTMENTS. THE DEMOLITION PERMIT APPLICATION, AVAILABLE ON THE CITY OF BURLINGAME BUILDING DEPARTMENTS WEB SITE, WILL NEED NEED TO BE COMPLETED PRIOR TO BUILDING DEPARTMENT APPROVAL AND THE START OF WORK. OWNER SHOULD CALL BAAQMD FOR QUESTIONS CONCERNING OBTAINING A PERMIT FROM THE BAY AREA QUALITY MANAGEMENT DISTRICT. 4. RECYCLING AN WAST REDUCTION FORM WILL N TO SUBMITTED AN RE L G D E RED R LL NEED BE B ED D APPROVED PRIOR TO ISSUANCE OF BUILDING PERMIT. THE OWNER SHOULD CONTACT JOE MAGLUSKEY RECYCLING SPECIALIST'a 650-558-1213 L I -I OJ CTS THAT CREATE AND/OR, AC 2500 SQUARE FEET TO 10000 SQUAB FEET PR E RE E D R REPL E RE EE E EE OF IMERVIOUS SURFACE (E.G., NEW ROOF, DRIVEWAY, OR OTHER NON -PERVIOUS SURFACE) 'MUST COMPLY WITH THE SAN FRANCISGO BAY MUNICIPAL REGIONAL STORMWATER NPDES ,PERMIT. PLEASE SHOW ON PLANS WHICH SITE DESIGN MEASURES) LISTED ON THE STORMWATER CHECKLIST FOR SMALL PROJECTS WILL BE INSTALLED TO MEET THIS >REQUIREMENT. A COPY OF THE SMALL PROJECTS CHECKLIST IS ACCESSIBLE HERE: https://www.burlireame.or/etarmwaterdevelopment. - DESIGN MEASURE: DIRECT ROOF RUNOFF ONTO VEGETATED AREAS USING A DISCONNECTED DOWNSPOUT AND PROVIDE CONSTRUCTION DETAILS OF SPLASH BLOCK OR CONNECT DOWNSPOUT TO DRAIN PIPE WITH POP-UP EMITTERS). AC NOTES: AC EQUIPMENT WILL NOT EXCEED A MAXIMUM , OUTDOOR NOISE LEVEL (dBA OF SIXTY (60) dBA DAYTIME (1:00 AM - 10:00 PM) OR FIFTY (50) dBA j NIGHTIME (10:00 PM - 7:00 AM) AS MEASURED FROM THE PROPERTY LINE. BMIG 25.55.050 \ � � I I. ANY WORK IN THE CITY RIGHT-OF-WAY, SUCH AS STREET, SIDEWALK AREA, PUBLIC EASEMENTS, AND UTILITY EASEMENTS, IS REQUIRED TO OBTAIN AN ENCROACHMENT PERMIT PRIOR TO STARTING WORK. 2. BASED ON THE SCOPE OF WORK, THIS IS A TYPE I PROJECT THAT REQUIRES A STORMWATER CONSTRUCTION POLLUTION PREVENTION PERMIT. THIS PERMIT IS REQUIRED PRIOR TO ISSUANCE OF A BUILDING PERMIT. AN INITIAL FIELD INSPECTION IS REQUIRED PRIOR TO THE START OF ANY CONSTRUCTION (ON PRIVATE PROPERTY OR IN THE PUBLIC RIGHT-OF-WAY). 3. A REMOVE/REPLACE UTILITIES ENCROACHMENT PERMIT IS REQUIRED TO (1) REPLACE ALL CURB, GUTTER, DRIVEWAY AND SIDEWALK FRONTING SITE, (2) PLUG ALL EXISTING SANITARY SEWER LATERAL CONNECTIONS AND INSTALL A NEW 4" LATERAL, (3) ALL WATER LINE CONNECTIONS TO CITY WATER MAINS FOR SERVICES OR FIRE LINE ARE TO BE INSTALLED PER CITY STANDARD PROCEDURES AND SPECIFICATION, (4) ANY OTHER UNDERGROUND UTILITY WORKS WITHIN CITY'S RIGHT-OFWAY. 4. CONSTRUCTION HOURS IN THE CITY PUBLIC RIGHT-OF-WAY ARE LIMITED TO WEEKDAYS AND NON -CITY HOLIDAYS BETWEEN S:COA.M. AND 5:00 P.M. THIS INCLUDES CONSTRUCTION HAULING. 5. NO STORM WATERS, UNDERGROUND WATERS DRAINING FROM ANY LOT, BUILDING, OR PAVED AREAS SHALL BE ALLOWED TO DRAIN TO ADJACENT PROPERTIES NOR SHALL THESE WATERS BE CONNECTED TO THE CITY'S SANITARY SEWER SYSTEM. THESE WATERS SHALL ALL DRAIN TO EITHER ARTIFICIAL OR NATURAL STORM DRAINAGE FACILITIES BY GRAVITY OR PUMPING REGARDLESS OF THE SLOPE OF THE PROPERTY. NO RAIN WATER FROM ROOFS OR OTHER RAIN WATER DRAINAGE SHALL DISCHARGE UPON A PUBLIC SIDEWALK (EXCEPT IN SINGLE FAMILY AREA) PER MUNICIPAL CODE SECTION 1,S.Oa.090. 6. ALL WATER LINES CONNECTIONS TO CITY WATER MAINS FOR SERVICES OR FIRE LINE PROTECTION ARE TO BE INSTALLED PER CITY STANDARD PROCEDURES AND MATERIAL SPECIFICATIONS. CONTACT THE CITY WATER DEPARTMENT FOR CONNECTION FEES. IF REQUIRED, ALL FIRE SERVICES AND SERVICES 2" AND OVER WILL BE INSTALLED BY BUILDER. ALL UNDERGROUND FIRE SERVICE CONNECTIONS SHALL BE SUBMITTED AS SEPARATE UNDERGROUND FIRE SERVICE PERMIT FOR REVIEW AND APPROVAL. 1. NO STRUCTURE SHALL BE BUILT INTO CITY'S RIGHT-OF-WAY 8. THE PROJECT SHALL COMPLY WITH THE CITY'S NPDES PERMIT REQUIREMENTS TO PREVENT STORM WATER POLLUTION. 9. ALL DEBRIS/GARBAGE CONTAINERS LOCATION SHALL BE ON PROPERTY. IN A SITUATION WHERE THAT IS NOT POSSIBLE, AN ENCROACHMENT PERMIT IS REQUIRED FROM PUBLIC WORKS DEPARTMENT FOR PLACING DEBRIS/GARBAGE CONTAINERS IN PUBLIC RIGHT-OF-WAY. NO WET GARBAGE FLUID SHALL ENTER PUBLIC RIGHT-OF-WAY OR THE STORM DRAIN SYSTEM. 10. IT IS THE RESPONSIBILITY OF THE OWNER AND/OR CONTRACTOR TO NOTIFY UNDERGROUND SERVICE ALERT (USA) AT LEAST 40 HOURS BEFORE THE START OF ANY EXCAVATION WORK. 11. IF PUBLIC WORKS REQUIRES SIDEWALK REPLACEMENT POLICY FOR EXPANDING WIDTH OF PLANTER STRIP MUST IMPLEMENTED D BE AROUND NEW OR EXISTING CITY STREET TREE. FUBL IC LUORK5 517E NOTES: I. DUE TO THE SCOPE OF WORK, SHOW THE REPLACEMENT OF ALL CURB, GUTTER, DRIVEWAY AND SIDEWALK FRONTING SITE, PLUG ALL EXISTING SANITARY SEWER LATERAL CONNECTIONS AND INSTALL A NEW 4" LATERAL, ALL WATER LINE CONNECTIONS TO CITY WATER MAINS FOR SERVICES OR FIRE LINE ARE TO BE INSTALLED PER CITY STANDARD PROCEDURES AND SPECIFICATION, AND ANY OTHER UNDERGROUND UTILITY WORKS WITHIN CITY'S RIGHT-OF-WAY. (PLEASE CALL -OUT THESE ITEMS TO BE REMOVED AND REPLACED ON THE SITE PLAN. ALL ABANDONED SEWER LATERAL OR WATER SERVICE SHALL BE DISCONNECTED AT THE MAIN AND PER CITY REQUIREMENTS.) AN ENCROACHMENT PERMIT WILL BE REQUIRED FOR THESE ITEMS, DUE TO THE EXTENSIVE SCOPE OF WORK, AND FROM THE PAST EXPERIENCE,THE CONCRETE FLATWORK WILL BECOME DAMAGE DURING CONSTRUCTION OF THE STRUCTURES. IF THE SIDEWALK HAS REED RECENTLY REPLACE OR IS IN GOOD CONDITION, PLEASE NOTE THAT "ALL DAMAGE SIDEWALK, CURB„ AND GUTTER DURING CONSTRUCTION WILL BE REPAIRED. AN INSPECTION BY THE CITY PUBLIC WORKS INSPECTOR WILL DETERMINE THE LIMITS OF THE REPAIRS POST -CONSTRUCTION. 2. REAR GARAGE AND ADU ROOF MUST DRAIN AND/OR BE INTERCEPTED WITHIN THE PROPERTY LIMITS. NO RUNOFF IS ALLOWED TO THE REAR ALLEY. 3. IF POST -CONSTRUCTION IMPERVIOUS AREA IS GREATER THAN 40% OF TOTAL LOT SIZE, MITIGATION OF THE ADDITIONAL STORM RUNOFF IN EXCESS OF 40% TOTAL LOT SIZE MUST BE ADDRESSED. PLEASE SHOW HOW THE POST-GONSTRUCTION DESIGN WILL ADDRESS THE ADDITIONAL STORMOFF. 4, NO PERMANENT STRUCTURES (RETAINING WALLS, FENCES, COLUMNS, MAILBOX, ETC.) PROPOSED BEYOND THE PROPERTY LINE AND INTO THE PUBLIC RIGHT-OF-WAY. REVISIONS BY PLNG PC1 08/25/21 0 PU CA W � v� O z/1 O W Z a00 ao aQ' U W �Q QUA I o 4 3 � CIO 78 a� >~ o >. H C> Q~Q a bj) 0 25 Q Cn a.)Jy ~ � � U CIS CIS U _ cn o co 8 t; 3 5 2 o c> � 3 C.> > F_^C O r� 0 I� W � O P-I DATE: MAY 10,21 SCALE: AS NOTED DRAWN: MC JOB: SHEET NO. A*201 OF SHEETS —1 Isa_5 SO.O- � 6 I d s d rc J I P P P (N) Unit Pavers Lei Garage It -F] hLY I 11�1-� 'I 1% �PERU�OUS tYy RiRocK BASE !m I � 150.8 i 150.8 X `✓'I , (N) STUCCO COLUMN TO MATCH EXT'G RETAINING WALL I T I x 15 1 (N) AUTOMATIC GATE 1 i I V x 1-1/4" TUBULAR STEEL rI DAu TO MATCH EXT'G RETAINING WALL w/integral color I ELEV 159.50 a(� AL:Lh rAL HEMER (N) WOOD FENCE, 6' H ROSA CO R I 55.6 N 4'-011 �2.5 BEABACK - s5.1 Q X x 163.2 1 1 I i + + p+ f` x + Concrete 2 + + * c�' _ Patio ° + . + FF EL 159.00 ° + + Z \ ° \ NAN DO n Residence ° + O R SACOR d° - - + + x LAV ANG r (N) RETAINING WALL O + + + N a - I MAG SOU 6'0HIGH 1F *++ ++ w/GUARDRAIL, 42"H 0 + + HEMER + + + BUD DAV + + + + \ HEBE 0 + ® \ \, CAM JAP 0 + + (E) TREES o +++ + ++ TO REMAIN + + _ —�. + _+ O 1 + +}+ + n n + + + * O + + * + I522 + n ° + + .+ + O + + + + + + + ..te + + + ___ __ MYO PAR + + - - - - - t O ° 6. + - - - -Ina +++ + + + + + _ toL. .. HEUCH •GATE OPEN POSITION r�r. - �� (E) TREES - - x 151.0 - I u REMAIN Benito Avenue 155.02' BASIS OF 5EARING6 N 5500316" W 554.01' (1"I0N.-MON.) (22 LLS 59J 3 Drivewa Gate Not to Scale PHOR LAV ANG Landscape Site Plan 1181, = 1'o" i 1514 EM ROSA COR RETAINING WALL / TO REMAIN 1. CONTRACTOR SHALL CONTACT UNDERGROUND SERVICES ADMINISTRATION PRIOR TO EXCAVATION AND GRADING. 2. ALL PLANTING AREAS SHALL BE CLEARED OF WEEDS AND OTHER DEBRIS. THE CONTRACTOR SHALL VERIFY WITH THE OWNER WHICH EXISTING PLANTS ARE TO REMAIN. EXISTING PLANTS TO BE REMOVED SHALL BE VERIFIED WITH OWNER PRIOR TO REMOVAL. ALL IVY IN PROJECT AREA SHALL BE REMOVED; IVY SHALL BE SPRAYED WITH HERBICIDE TWO WEEKS PRIOR TO REMOVAL. 3. SOIL TESTING SHALL BE UNDERTAKEN BY THE CONTRACTOR, AND PERFORMED BY A CERTIFIED LABORATORY. A COPY OF THE REPORT SHALL BE PROVIDED TO THE OWNER AND LANDSCAPE ARCHITECT. RECOMMENDATIONS FOR AMENDMENTS AND FERTILIZATION SHALL REFLECT THE NUTRIENT REQUIREMENTS OF SPECIFIED PLANT SPECIES. 4. SOIL AMENDMENTS SHALL BE FREE OF DEBRIS SUCH AS LITTER, BROKEN CLAY POTS, AND OTHER FOREIGN MATERIAL. ROCKS LARGER THAN ONE INCH DIAMETER WILL NOT BE PERMITTED. SOIL AMENDMENTS SHALL HAVE THE FOLLOWING CONTENT: REDWOOD NITRIFIED COMPOST 40%, COARSE SAND 30%, BLACK TOPSOIL 30%. S. PLANT HOLES SHALL BE DOUBLE THE SIZE OF THE CONTAINER (generally). THE WALLS AND BASES OF PLANT HOLES SHALL BE SCARIFIED. HOLES SHALL BE BACKFILLED WITH THE FOLLOWING MIXTURE: 80%TO 20% IMPORTED SOIL TO EXISTING SOIL. 6. SOIL BERMS SHALL BE FORMED AROUND ALL PLANTS 1 GALLON SIZE AND LARGER. BASINS SHALL BE MULCHED WITH A 3"LAYER OF BARK CHIPS, MINIMUM OF 1" IN SIZE. PLANTING AREAS SHALL BE COVERED WITH A TWO INCH LAYER OF BARK CHIPS. 7. ALL PLANTS SHALL BE FERTILIZED. FERTILIZER SHALL BE COMMERCIALLY AVAILABLE TYPE, AGRIFORM OR EQUIVALENT. APPLICATION SHALL BE ACCORDING TO MANUFACTURER'S INSTRUCTIONS. RESIDUAL WEED PRE -EMERGENT SHALL BE APPLIED BY THE CONTRACTOR. APPLICATION SHALL BE ACCORDING TO MANUFACTURER'S INSTRUCTIONS. 8. TREES SHALL BE STAKED WITH TWO PRESSURE TREATED 2" DIAMETER POLES. TREE TRUNK SHALL BE SECURED WITH TWO RUBBER TIES OR STRAPS FORMING A FIGURE -EIGHT BETWEEN Plant List No. Botanical Name Common Name Oty' Size WI Plant Type/ Remarks ACER PAL Acer palmatum Japanese Maple 2 24" Box M Decid Tree MAG SOU Magnolia soulangiana Saucer Magnolia 3 24" Box M Decid Tree BUD DAV Buddleia davidii Butterfly Bush 1 15 Gal M Decid Shrub CAM JAP Camellia japonica Japanese Camellia 5 Gal H Evgn Shrub HEBE Hebe'Veronica Lake' Veronica Lake Hebe 5 Gal M Evgn Shrub HEMER Hemerocallis'Yellow' Daylily 1 Gal M Low Shrub HEUCH Heuchera sanguinea Coral Bells 1 Gal L Perennial Jasmine LAV ANG Lavendula angustifolia English Lavender 5 Gal L Perennial NAN DOM Nandian domestba Heavenly Bamboo 5 Gal L Evgn Shrub PHOR Phonnium'Dwarf Red' Miniature Red Flax 1 Gal L Perennial PIT TEN I Pittosporum tenuifolium Black Stem 5 Gal I L Evgn Shrub 'Silver Sheen' Pittosporum PIT TOB Pittosporum tobira Varigated Japanese 5 Gal L Evgn Shrub Vadegata' Plttosporum ROSA COR Rosa Coral Drift Coral Drift Rose 2 Gal L Decid Sub -Shrub TRA JAS Trachebspennum Star Jasmine 15 Gal M Espalier Vine jasminoides MYO PAR Myoporum parvifolium Creeping Myopour —I L Groundcover Prostratum White' Note: Contractor to verify quantities Copy ge ie 9 Bruce A. Chan Landscape Architect CA LIa. # 002324 923 Arguello Street, Suite 200 Redwood City, California 94063 Tel (650) 346-7645 Fax (650)367-8139 Email: bacla®sbcglobal.net Landscape Architecture Environmental Design Site Planning N0.2314 DP 0>31a2v cor cAUFd? 9 TITLE Landscape Plan REVISIONS Date I Notes PROJECT#: DATE: 08-27-21 SHEET #: L 1A 0 2 4 6 B 10 12 14 16 1B A 4 At M N XI V N At N 0 t3 M M a 0 9 40 o st M a M % fa M R N fi " W a & & M 0 12 Y % !e IN 10 IN 1N IN 110 122 124 116 118 IN IV IN 125 11 I) 132 11 06 IN to