Loading...
HomeMy WebLinkAboutReso - PC - 2021.09.13 - 8B; DocuSign Envelope lD: 7 1 44276C-21 6E-4AFg-ACAs-1A01 E30AB5DE RECORDING REQUESTED BYI Planning Department City of Burlingame WHEN RECORDED MAIL TO: COMMUNITY DEVELOPMENT DEPARTMENT CITY OF BURLINGAME 501 PRIMROSE ROAD BURLINGAME, CA 94010 2021-166681 1:31 Pm 'l2t1$l21 R1 Fee: NO FEE Count of Pages 4 Recorded in Official Records CountY of San Mateo Mark Church rlrl ! ill[i[rfl [r[il UuxfiniiiUi[fi UU tt t trr +(Resolution No. 2021-09. 1 3.21-8b 722 ACACIA AVENUE 029-044-250 TITLE OF DOCUMENT I hereby certify this to be a full, true and conect copy of the document it purports to be, the original of which is on file in my office. October 25 2021 k rlru T I rrUNg Date: Kevin Gardiner, AICP, Community Development Director RESOLUTION APPROVING CATEGORICAL EXEMPTION AND DESIGN REVIEW RESOLVED, by the Planning Commission of the City of Burlingame that: WHEREAS, a Categorical Exemption has been prepared and application has been made fo r Desiqn Review for a second storv addition to an existinq sinole familv dwelling at 722 Acacia Drive Zoned R-1 el and Alexander Em n owners APN: WHEREAS,said matters were heard by the Planning Commission of the City of Burlingame on Seotembe r 13.2021 at which time it reviewed and considered the staff report and all other written materials and testimony presented at said hearing; NOW, 1. 2. THEREFORE, it is RESOLVED and DETERMINED by this Planning Commission that: on the basis of the lnitial study and the documents submitted and reviewed, and comments received and addressed by this Commission, it is hereby found that there is no substantial evidence that the project set forth above will have a significant effect on the environment, and categorical exemption, per CEQA Section 15301 (e)(1) of the CEQA Guidelines, which states that additions to existing structures are exempt from environmental review, provided the addition will not result in an increase of more than 50% of the floor area of the structures before the addition are exempt from environmental review, is hereby approved. Said Design Review is approved subject to the conditions set forth in Exhibit "A" attached hereto. Findings for such Design Review are set forth in the staff report, minutes, and recording of said meeting. 3. lt is further directed that a certified copy of this resol the County of San Mateo. n be reco official records of c trman M.6A{JL , Secretary of the Planning Commission of the hereby certify that the foregoing resolution was introduced and adopted at a Planning Commission held on the 13th dav of September.2021 b 722 ACACA DR - RESO 2021{t9.13{bAYES: COIAROTO, GAUL LOmS, SCHTIID, TSEITOES: I{O E ABSEI{T: LARTOS,TERRONES RECUSED: NOlrlE City of Burlingame, do regular meeting of they the following vote: Secretary EXHIBIT ..A" Conditions of Approval for Categorical Exemption and Design Review 722 Acacia Drive Effective September 23, 2021 Page 'l 1 that the project shall be built as shown on the plans submitted to the Planning Division date stamped August 20, 2021 , sheets A1 through A7; that any changes to building materials, exterior finishes, windows, architectural features, roof height or pitch, and amount or type of hardscape materials shall be subject to Planning Divasion or Planning Commission review (FYl or amendment to be determined by Planning staff); that any changes to the size or envelope of the basement, first or second floors, or garage, which would include adding or enlarging a dormer(s), shall require an amendment to this permit; 2 ? 4 ( b 7 a I that any recycling containers, debris boxes or dumpsters for the construction project shall be placed upon the private property, if feasible, as determined by the Community Development Director; that demolition for removal of the existing structures and any grading or earth moving on the site shall not occur until a building permit has been issued and such site work shall be required to comply with all the regulations of the Bay Area Air Quality Management District; that prior to issuance of a building permit for construction of the project, the project construction plans shall be modified to include a cover sheet listing all conditions of approval adopted by the Planning Commission, or City Council on appeal; which shall remain a part of all sets of approved plans throughout the construction process. Compliance with all conditions of approval is required; the conditions of approval shall not be modified or changed without the approval of the Planning Commission, or City Council on appeal; that all air ducts, plumbing vents, and flues shall be combined, where possible, to a single termination and installed on the portions of the roof not visible from the street; and that these venting details shall be included and approved in the construction plans before a Building permit is issued; that the project shall comply with the Construction and Demolition Debris Recycling Ordinance which requires affected demolition, new construction and alteration projects to submit a Waste Reduction plan and meet recycling requirements; any partial or full demolition of a structure, interior or exterior, shall require a demolition permit; that the project shall meet all the requirements of the California Building and Uniform Fire Codes, in effect at time of building permit submittal, as amended by the City of Burlingame; THE FOLLOWING CONDITIONS SHALL BE MET DURING THE BUILDING INSPECTION PROCESS PRIOR TO THE INSPECTIONS NOTED IN EACH CONDITION: 10. that prior to scheduling the framing inspection the applicant shall provide a certification by the project architect or residential designer, or another architect or residential designprofessional, that demonstrates that the project falls at or below the maximum approved floor area ratio for the property; EXHIBIT "A" Conditions ofApproval for Categorical Exemption and Design Review 722 Acacia Dtive Effective September 23, 2021 Page 2 11 12 that prior to scheduling the framing inspection the project architect or residential designer, or another architect or residential design professional, shall provide an architectural cedification that the architectural details shown in the approved design which should be evident at framing, such as window locations and bays, are built as shown on the approved plans; architectural certification documenting framing compliance with approved design shall be submitted to the Building Division before the final framing inspection shall be scheduled; and that prior to final inspection, Planning Division staff will inspect and note compliance of the architectural details (trim materials, window type, etc.) to verify that the project has been built according to the approved Planning and Building plans. ± 0'-0"+9'-2"FIN. FLR1ST FIN. FLR 2ND(E) HT. OFHOUSE±21'-6"12121"12(N) SKYLIGHT PER ROOFPLAN & SCHEDULE,SEE DETAILS ON A8(N) SMALL EXPOSURECEDAR SIDING TOMATCH (E)CLASS "B" MODIFIED BITUMEN (TORCH DOWN)ROOFING RUBEROID TORCH GRANULE ORAPPROVED EQ. ON 30 # BUILDING PAPER OVER58" CD TYPE 'X' PLYWD. SHEATHING OVER (N)FRAMING PER STRUCTURAL SPEC.S. ROOFINGTO BE DONE BY QUALIFIED INSTALLER. COLORTO MATCH (E) SHINGLES IF POSSIBLE(N) CASEMENT WINDOW PER SCHEDULE,SEE DETAILS ON A8 FOR TYP. WINDOW TRIM.+ 16'-9"TOP PLATE(E)(E)(E)(E)(E)(N)(N) GUTTER& DOWNSPOUT(E) GUTTER& DOWNSPOUT(E) GUTTER& DOWNSPOUTPROPERTY LINE 45° 12'-0"DAY LIGHT PLANEPROPERTY LINE 12'-0"DAY LIGHT PLANE45°97.96 PROPERTYSPOT ELEVATION97.96 PROPERTYSPOT ELEVATION100.00FIN. FL.109.16FIN. FL.ALL (N) WINDOWS ARE DOUBLE PANEWHITE WOOD TO MATCH (E).FOR (E) WINDOWS MATERIALS, SEEEXISTING PLANS ON SHEETS A3 & A498.30POINT OFDEPARTURE98.38POINT OFDEPARTURE12121"12FIN. FLR1ST± 0'-0" FIN. FLR 2ND+9'-5"(E) HT. OFHOUSE±21'-6"REMOVE (E) DORMER& WINDOW(E)(E)(E)(E)(E)(E)(E) GUTTER& DOWNSPOUT(E) GUTTER& DOWNSPOUTFIN. FLR1ST± 0'-0" FIN. FLR 2ND+9'-5"(E) HT.OF HOUSE±21'-6"128REMOVE(E) DORMER& WINDOW(E)(E)(E)(E)(E)(E)(E)(E)(E) GUTTER(E) GUTTER& DOWNSPOUT(E) GUTTER& DOWNSPOUT(E) GUTTER& DOWNSPOUT100.00FIN. FL.109.16FIN. FL.REMOVE (E)WINDOWS. MAINTAIN(E) OPEN'G± 0'-0"+9'-2"(E) HT.OFHOUSE±21'-6"FIN. FLR1ST FIN. FLR 2ND128122(N) SKYLIGHT PERROOF PLAN &SCHEDULE,SEE DETAIL(N) SMALL EXPOSURECEDAR SIDING TOMATCH (E)CLASS "B" MODIFIED BITUMEN (TORCH DOWN) ROOFING RUBEROIDTORCH GRANULE OR APPROVED EQ. ON 30 # BUILDING PAPEROVER 58" CD TYPE 'X' PLYWD. SHEATHING OVER (N) FRAMING PERSTRUCTURAL SPEC.S. ROOFING TO BE DONE BY QUALIFIEDINSTALLER. COLOR TO MATCH (E) SHINGLES IF POSSIBLE8'-1"(N) 131 S.F. 2ND STORYDORMER ADDITIONTOP PLATE+16'-9"1'-10"(N) 24 S.F. 2ND STORYINTERIOR ADDITION(N) 39 S.F. 2ND STORY INTERIORADDITION ON OPP. SIDE OF HOUSE(E)(E)(E)(E)(E)(E)(N)(N) GUTTER& DOWNSPOUT(E) GUTTER(E) GUTTER& DOWNSPOUT(E) GUTTER& DOWNSPOUT(E) GUTTER& DOWNSPOUT(N) CASEMENT WINDOW IN EXISTING OPENING PERSCHEDULE, AS REQUIRED FOR RESCUE/EGRESS. DONOT DISRUPT SIDING IF POSSIBLE. SEE DETAILS ONA8 FOR TYP. WINDOW TRIM IF NEEDED.CUSTOM MULLIONS TO APPEAR ASDOUBLE HUNG WINDOW PAIRALL (N)WINDOWS AREDOUBLE PANEWHITE WOODTO MATCH (E).FOR (E)WINDOWSMATERIALS,SEE EXISTINGPLANS ONSHEETS A3& A4.1/4" = 1'-0"4.5.2021EXISTING & PROPOSED ELEVATIONS A6PROPOSED REAR ELEVATIONSCALE: 1/4" = 1'-0"James Neubert Architects 693 Third Avenue Redwood City, CA 94063 . . . . . . . . . . . . . . . . . . . . . Tel: 650.357.0408 www.jamesneubert.comSCALE: DATE:REVISIONS:THESE DRAWINGS ARE INTELLECTUAL PROPERTY, INTENDED FOR PUBLIC RECORD DOCUMENTS. IT IS UNLAWFUL TO COPY OR REPLICATE THESE CONFIGURATIONS IN ANY WAY THAT DEMONSTRATES APPROPRIATION OF THESE IDEAS, SUBJECT TO CRIMINAL PROSECUTION. 722 ACACIA DRIVE, BURLINGAME, CA 94010 EMANUEL RESIDENCE DEMOLITION REAR ELEVATIONSCALE: 1/4" = 1'-0"PROPOSED RIGHT ELEVATIONSCALE: 1/4" = 1'-0"DEMOLITION RIGHT ELEVATIONSCALE: 1/4" = 1'-0"38.18.20213NORTHEAST ELEVATIONNORTHEAST ELEVATIONSOUTHEAST ELEVATIONSOUTHEAST ELEVATION3 1STFLOORFIN.± 0'-0"2NDFLOORFIN.+9'-5"(E) TOPOF ROOF±21'-6"(E)(E)(E)(E)(E)(E)(E)(E)(N)(N) DOUBLE HUNG WINDOW IN EXISTING OPENINGPER SCHEDULE, AS REQUIRED FOR RESCUE/EGRESS.DO NOT DISRUPT SIDING IF POSSIBLE. SEE DETAILSON A8 FOR TYP. WINDOW TRIM IF NEEDED.(E) GUTTER(E) GUTTER& DOWNSPOUT(E) GUTTER& DOWNSPOUT1ST FLOORFIN.± 0'-0"(E) & (N)PLATEHEIGHT+8'-5"(E) GUTTER& DOWNSPOUT100.00FIN. FL.109.16FIN. FL.ALL (N) WINDOWS ARE DOUBLE PANEWHITE WOOD TO MATCH (E).FOR (E) WINDOWS MATERIALS, SEEEXISTING PLANS ON SHEETS A3 & A4(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)1ST FLOORFIN.± 0'-0"(E) & (N)PLATEHEIGHT+8'-5"1STFLOORFIN.± 0'-0"2NDFLOORFIN.+9'-5"(E) TOPOF ROOF±21'-6"(E) GUTTER& DOWNSPOUT(E) GUTTER(E) GUTTER& DOWNSPOUT(E) GUTTER& DOWNSPOUT100.00FIN. FL.109.16FIN. FL.REMOVE (E) WINDOWS.MAINTAIN (E) OPEN'G± 0'-0"+9'-2"FIN. FLR 1ST FIN. FLR 2ND(E) HT. OFHOUSE±21'-6"+ 17'-2"TOP PLATE(E)(E)(E)(E)(E)(E)(E)(E)(E)(E)ALL (N) WINDOWS ARE DOUBLE PANEWHITE WOOD TO MATCH (E).FOR (E) WINDOWS MATERIALS, SEEEXISTING PLANS ON SHEETS A3 & A4(E) GUTTER(E) GUTTER& DOWNSPOUTPROPERTY LINE 45° 12'-0"DAY LIGHT PLANEPROPERTY LINE12'-0"DAY LIGHT PLANE45°97.53TOP OFCURB97.44TOP OF CURB(E) GUTTER& DOWNSPOUT97.96 PROPERTYSPOT ELEVATION97.96PROPERTYSPOTELEVATION100.00FIN. FL.109.16FIN. FL.97.49AVERAGETOP OF CURB98.38POINT OFDEPARTURE98.30POINT OFDEPARTURE24'-0"(E) OVERALL HEIGHT FROMAVERAGE TOP OF CURB 1/4" = 1'-0"4.5.2021EXISTING & PROPOSED ELEVATIONS A6aPROPOSED LEFT ELEVATIONSCALE: 1/4" = 1'-0"James Neubert Architects 693 Third Avenue Redwood City, CA 94063 . . . . . . . . . . . . . . . . . . . . . Tel: 650.357.0408 www.jamesneubert.comSCALE: DATE:REVISIONS:THESE DRAWINGS ARE INTELLECTUAL PROPERTY, INTENDED FOR PUBLIC RECORD DOCUMENTS. IT IS UNLAWFUL TO COPY OR REPLICATE THESE CONFIGURATIONS IN ANY WAY THAT DEMONSTRATES APPROPRIATION OF THESE IDEAS, SUBJECT TO CRIMINAL PROSECUTION. 722 ACACIA DRIVE, BURLINGAME, CA 94010 EMANUEL RESIDENCE DEMOLITION LEFT ELEVATIONSCALE: 1/4" = 1'-0"EXISTING FRONT ELEVATIONSCALE: 1/4" = 1'-0"16.8.2021NORTHWEST ELEVATION NORTHWEST ELEVATION SOUTHWEST ELEVATION26.28.2021NO WORK AT THE FRONT OF HOUSE 1:12 SLOPE 1:12 SLOPE 12:12 SLOPE 12:12 SLOPE 8:12SLOPE8:12SLOPE8:12SLOPE8:12SLOPE4:12SLOPE12:12 SLOPE 12:12 SLOPE 8:12SLOPE8:12SLOPE(E) MAIN RIDGE OF HOUSE AREA OF (N) FRAMING FOR DORMERAREA OF (N) FRAMING FOR DORMER 2 D A9 D A9 D A9 D A9 12:12 SLOPE 12:12 SLOPE 2:12SLOPE8:12SLOPE8:12SLOPE8:12SLOPE2:12SLOPE12:12 SLOPE 12:12 SLOPE 3 A8 2 A8 8:12SLOPE8:12SLOPE(E) MAIN RIDGE OF HOUSE James Neubert Architects693 Third AvenueRedwood City, CA 94063. . . . . . . . . . . . . . . . . . . . . Tel: 650.357.0408www.jamesneubert.comSCALE: DATE: REVISIONS:THESE DRAWINGS ARE INTELLECTUAL PROPERTY, INTENDED FOR PUBLIC RECORD DOCUMENTS. IT IS UNLAWFUL TO COPY OR REPLICATE THESE CONFIGURATIONS IN ANY WAY THAT DEMONSTRATES APPROPRIATION OF THESE IDEAS, SUBJECT TO CRIMINAL PROSECUTION. 722 ACACIA DRIVE, BURLINGAME, CA 94010EMANUEL RESIDENCE 1/4" = 1'-0" 4.5.2021 EXISTING & PROPOSED ROOF PLANSA5 (N) 2x4 WOOD STUD WALL SYMBOL DESCRIPTION LEGEND EXISTING WALL TO REMAIN WALL TO BE REMOVED ELEVATION VIEW DRAWING NUMBER SHEET NUMBER DIRECTION OF CUT / VIEW X AX X/AX B A9 BUILDING SECTION VIEW NPROPOSED ROOF PLAN SCALE: 1/4" = 1'-0" DEMOLITION ROOF PLAN SCALE: 1/4" = 1'-0"NCLASS "B" MODIFIED BITUMEN (TORCH DOWN) ROOFING RUBEROID TORCH GRANULE OR APPROVED EQ. BY QUALIFIED INSTALLER. COLOR TO MATCH (E) SHINGLES IF POSSIBLE ALL NEW ROOF DRAINAGE TO BE DIRECTED TO LANDSCAPE AREAS TO THE EXTENT FEASIBLE AND NOT ONTO ADJACENT PROPERTIES. 3 8.18.2021 3 H.B.(E) CONC.DRIVEWAYA C A C I A D R I V E5'-0"(E)SETBACK(E)CONC.DRIVEWAYAPRONCONC. SIDEWALK50.00'50.00'133.00' 132.50'(E) WOOD FENCE(E) WOOD FENCE (E) WOOD FENCE(E) PORCH(E) LAWN(E) LAWN(E) ELEC. PANEL(200A) & POWERDROP LOCATION(E) GAS METER(E) 8" PLUMTREE(E) DRYWELL w/SUMP PUMP(E)UNDERGROUNDWATERPIPE(E) HOSEBIBB(E) GATE(E)IRRIGATIONCONTROLS& VALVES(E) 11'-8"H.B.(E) HOSE BIBB(E) WATERHEATEREXISTINGTWOSTORYHOUSEDN24 sfinterioraddition39 sfinterioraddition131 SFDORMERADDITION42'-6"(E) SET B A C K @ 1 s t F L O O R 58'-8"(E) SET B A C K @ 2 n d F L O O R (E) SE T B A C K @ 1 s t F L O O R 23'-8"10" Ø SILVERBIRCH TREES30'-9"(E) SE T B A C K @ 2 n d F L O O R 9'-8"(E) SETBACK @1st & 2ndFLOORS(E) 5'-0"(E) SETBACK @1st & 2ndFLOORS98.49NG98.18NG98.57NG98.10NG97.44TFC97.53TFC97.67TFC97.98TFC97.96PROPERTY SPOTELEVATION97.96PROPERTY SPOTELEVATION97.96PROPERTYSPOTELEVATION97.96PROPERTYSPOTELEVATIONEXISTINGGARAGE(E)SETBACK(E) WATERMETER BOX(E)SEWERCLEANOUT(E)CLEANOUTH.B.(E) CONC.DRIVEWAYA C A C I A D R I V E(E) SETBACK @ 1st FLOOR23'-8"9'-8"5'-0"(E)SETBACK(E)CONC.DRIVEWAYAPRONCONC. SIDEWALK50.00'50.00'133.00'132.50'10" Ø SILVERBIRCH TREES(E) WOOD FENCE(E) WOOD FENCE(E) WOOD FENCE(E) PORCH(E) LAWN(E) ELEC. PANEL(200A) & POWERDROP LOCATION(E) GAS METER(E) 8" PLUMTREE(E) DRY WELL w/SUMP PUMP(E) UNDERGROUNDWATER PIPE(E) HOSE BIBB(E) SETBACK @1st & 2ndFLOORS(E) GATE(E) IRRIGATIONCONTROLS &VALVES(E) 11'-8"(E) 5'-0"H.B.(E) HOSE BIBB(E) WATER HEATERDNEXISTINGTWO STORYHOUSE30'-9"(E) SETBACK @ 2nd FLOOR (E) LAWN42'-6"(E) SETBACK @ 1st FLOOR58'-8"(E) SETBACK @ 2nd FLOOR(E) SETBACK @1st & 2ndFLOORS98.49NG98.18NG98.57NG98.10NG97.44TFC97.53TFC97.67TFC97.98TFCEXISTINGGARAGE(E)SETBACKJames Neubert Architects 693 Third Avenue Redwood City, CA 94063 . . . . . . . . . . . . . . . . . . . . . Tel: 650.357.0408 www.jamesneubert.comSCALE: DATE:REVISIONS:THESE DRAWINGS ARE INTELLECTUAL PROPERTY, INTENDED FOR PUBLIC RECORD DOCUMENTS. IT IS UNLAWFUL TO COPY OR REPLICATE THESE CONFIGURATIONS IN ANY WAY THAT DEMONSTRATES APPROPRIATION OF THESE IDEAS, SUBJECT TO CRIMINAL PROSECUTION. 722 ACACIA DRIVE, BURLINGAME, CA 94010 EMANUEL RESIDENCE 1/8" = 1'-0"4.5.2021SITE PLAN & PROJECT DATA A1VICINITY MAPSCALE: NTSINDEX OF DRAWINGSA1SITE PLAN & PROJECT DATAA2SPECIFICATIONSA2a BEST MANAGEMENT PRACTICESA3EXISTING 1ST FLOOR PLANA4EXISTING & PROPOSED 2ND FLOOR PLANA5EXISTING & PROPOSED ROOF PLANSA6EXISTING & PROPOSED ELEVATIONSA6aEXISTING & PROPOSED ELEVATIONSA7BUILDING SECTIONSA8DETAILSA9REFLECTED CEILING PLAN & INTERIORSA10TITLE 24A11TITLE 24 & CAL GREENS1.1 GENERAL NOTES & TYPICAL DETAILSS2.1 FOUNDATION PLANS2.2 SECOND FLOOR FRAMING PLANS2.3 ROOF FRAMING PLANS3.1 SECTIONSS3.2 SECTIONSAPN #: 029-044-250Building Occupancy Group: R 3/UZoning District: R1BConstruction Type: VBNumber of stories: 2Gross Lot Size: 6,600 S.F.Existing: 1st Floor Habitable1781 sf 2nd Floor Habitable 765 sf Detached 2-Car tandem Garage 401 sf (E) Total Habitable 2546 sfPROPOSED ADDITION: 2ND FLOOR HABITABLE 194 SF (N) TOTAL HABITABLE 2740 SF (E) Lot Cov. 2546/6600 sf .38 UNCHANGED Existing Building Height21'- 6" UNCHANGEDPROJECT DATAPROPOSED WORK:Interior remodel at 2nd floor to reor-ganize bedrooms from 3 bedrooms withno hallway to 3 bedrooms with ahallway. Now the rooms are separate &private, instead of 2 private rooms offone common room. Also a dormeraddition.Two bedrooms being enlarged on theinterior, one by 24 sf; one by 39 sf.A new 131 sf dormer addition for abathroom & walk-in closet. Totaladdition size is 194 sf.No work at 1st floor, except for anystructural work required for seismic &live load engineering for 2nd floor work.THE FOLLOWING APPLICABLECODES & REGULATIONS GOVERNTHE PROJECT:2019 California Residential Code2019 California Building Code2019 California Energy Code2019 CA Green Building Standards2019 CA Plumbing Code2019 CA Mechanical Code2019 CA Electrical Code2019 California Fire CodeAll other state & local ordinances &regulations apply, as well.PROPOSED SITE PLANSCALE: 1/8" = 1'-0"NEXISTING SITE PLANSCALE: 1/8" = 1'-0"N ALL NEWROOFDRAINAGETO BEDIRECTEDTOLANDSCAPEAREAS TOTHE EXTENTFEASIBLEAND NOTONTOADJACENTPROPERTIES.THE FOLLOWING MEASURES WILLENSURE TITLE 24 COMPLIANCE:1.Insulation in new exterior walls tobe R15. (min. R13 per Title 24Report).2.Blown-in cellulose insulation inroof to be R38. Rigid or battinsulation may be substituted. 3. Attic furnace to be 94% efficient. 4. (E) tankless water heater to bemaintained (Noritz NR98 OD) 5. New windows to have a 0.32U-value, 0.67 SHGC.6.(E) 80% efficient furnace incrawlspace.ALL NEW WORK ISAT THE 2ND FLOORWith regard to the type, ,1) STORMWATER CONSTRUCTION POLLUTIONPREVENTION PERMIT IS REQUIRED PRIOR TOISSUANCE OF A BUILDING PERMIT. AN INITIALFIELD INSPECTION IS REQUIRED PRIOR TO THESTART OF ANY CONSTRUCTION (ON PRIVATEPROPERTY OR IN THE PUBLIC RIGHT-OF-WAY).2) SEWER BACKWATER PROTECTION CERTIFICATIONREQUIRED FOR INSTALLATION OF ANY NEWSEWER FIXTURE. THE SEWER BACKWATERPROTECTION CERTIFICATE IS REQUIRED PRIORTO THE ISSUANCE OF BUILDING PERMIT.3) THE SANITARY SEWER LATERAL SHALL BETESTED PER ORDINANCE CODE CHAPTER 15.12.TESTING INFORMATION IS AVAILABLE AT THEBUILDING DEPT. A SEWER LATERALENCROACHMENT PERMIT IS REQUIRED.4) ANY NEW MECHANICAL EQUIPMENT INSTALLEDON EXTERIOR OF BUILDING TO NOT EXCEEDMAXIMUM OUTDOOR NOISE LEVEL OF 60 dBAFROM 7:00 AM TO 10: PM AND 50 dBA FROM 10:00PM TO 7:00 AM AS MEASURED FROM THEPROPERTY LINE.ADDITIONAL NOTES16.8.2021