HomeMy WebLinkAboutAgenda Packet - PC - 2018.01.22Planning Commission
City of Burlingame
Meeting Agenda
BURLINGAME CITY HALL
501 PRIMROSE ROAD
BURLINGAME, CA 94010
Council Chambers7:00 PMMonday, January 22, 2018
1. CALL TO ORDER
2. ROLL CALL
3. APPROVAL OF MINUTES
4. APPROVAL OF AGENDA
5. PUBLIC COMMENTS, NON-AGENDA
Members of the public may speak about any item not on the agenda. Members of the public wishing to
suggest an item for a future Planning Commission agenda may do so during this public comment period .
The Ralph M. Brown Act (the State local agency open meeting law) prohibits the Planning Commission
from acting on any matter that is not on the agenda. Speakers are asked to fill out a "request to speak "
card located on the table by the door and hand it to staff, although the provision of a name, address or
other identifying information is optional. Speakers are limited to three minutes each; the Chair may adjust
the time limit in light of the number of anticipated speakers.
6. STUDY ITEMS
7. CONSENT CALENDAR
Items on the consent calendar are considered to be routine. They are acted on simultaneously unless
separate discussion and /or action is requested by the applicant, a member of the public or a
commissioner prior to the time the Commission votes on the motion to adopt.
1333 Bayshore Highway, zoned IB - Application for a Conditional Use Permit for renewal
of an existing tent structure. The project is Categorically Exempt from review pursuant to
the California Environmental Quality Act (CEQA), per Section 15301, Class 1(a) of the
CEQA Guidelines. (Greg Farmer, Hyatt Regency San Francisco Airport, applicant; HMC
Burlingame Hotel LP, property owner; Academy Tent and Canvas, Inc ., designer) (17
noticed) Staff contact: Catherine Keylon
a.
1333 Bayshore Hwy - Staff Report
1333 Bayshore Hwy - Attachments
1333 Bayshore - Photos - 01.22.18 (no plans)
Attachments:
8. REGULAR ACTION ITEMS
Page 1 City of Burlingame Printed on 1/19/2018
January 22, 2018Planning Commission Meeting Agenda
1345 Balboa Avenue, zoned R-1 - Application for Design Review Amendment for
changes to a previously approved application for a first and second story addition to an
existing single family dwelling. The project is Categorically Exempt from review pursuant to
the California Environmental Quality Act (CEQA), per Section 15301 (e)(1) of the CEQA
Guidelines. (Roberty Wehmeyer, RC Wehmeyer Design, applicant and designer; Adam
and Denise Steinberger, property owners) (48 noticed) Staff Contact: Catherine Keylon
a.
1345 Balboa Ave - Staff Report
1345 Balboa Ave - Attachments
1345 Balboa Ave - Plans - 01.22.18
Attachments:
1327 Castillo Avenue, zoned R -1- Application for Design Review for first and second floor
additions to an existing two -story single family dwelling with an attached garage. This
project is categorically exempt from the California Environmental Quality Act (CEQA)
pursuant to CEQA Guidelines Section 15301 (e)(1). (Eiki Tanaka, Studio 02, Inc.,
designer and applicant; Celeste and Eric Leung, property owners) (60 noticed) Staff
Contact: Erika Lewit
b.
1327 Castillo Ave - Staff Report
1327 Castillo Ave - Attachments 1
1327 Castillo Ave - Attachments 2
1327 Castillo Ave - Plans - 01.22.18
Attachments:
705 Walnut Avenue, zoned R -1 - Application for Design review for a new, two -story
single-family dwelling with a detached garage. This project is categorically exempt from
the California Environmental Quality Act (CEQA) pursuant to CEQA Guidelines Section
15303 (a). (James Chu, Chu Design Associates, applicant and designer; 705 Walnut
Burlingame LLC, property owner) (72 noticed) Staff Contact: 'Amelia Kolokihakaufisi
c.
705 Walnut Ave - Staff Report
705 Walnut Ave - Attachments
705 Walnut Ave - Plans - 01.22.18
Attachments:
1669 Bayshore Highway, Unit B, zoned IB - Application for Conditional Use Permit and
Parking Variance for a commercial recreation (CrossFit studio) business. This project is
categorically exempt from the California Environmental Quality Act (CEQA) pursuant to
CEQA Guidelines Section 15301 (a). (Craig Ranier Gadduang, applicant; Blaise
Descollonges, RSS Architecture, architect; 1669 & 1699 Bayshore LLC, property owner )
(17 noticed) Staff Contact: 'Amelia Kolokihakaufisi
d.
1669 Bayshore Hwy - Staff Report
1669 Bayshore Hwy - Attachments
1669 Bayshore Hwy - Plans - 01.22.18
Attachments:
Page 2 City of Burlingame Printed on 1/19/2018
January 22, 2018Planning Commission Meeting Agenda
615 Airport Boulevard, zoned AA - Application to renew a Conditional Use Permit for long
term airport parking as an interim use. This project is categorically exempt from the
California Environmental Quality Act (CEQA) pursuant to CEQA Guidelines Section
15301. (Airport Parking LLC, applicant and property owner) (30 noticed) Staff Contact:
Ruben Hurin
e.
615 Airport Blvd - Staff Report
615 Airport Blvd - Attachments
615 Airport Blvd - Plans - 01.22.18
Attachments:
9. DESIGN REVIEW STUDY
1245 Cabrillo Avenue, zoned R -1 - Application for Design Review and Special Permit for
building height for a first and second story addition to an existing single family dwelling
and new detached garage (Chu Design Associates Inc ., applicant and designer; Eric and
Jennifer Lai, property owners) (57 noticed) Staff Contact: Ruben Hurin
a.
1245 Cabrillo Ave - Staff Report
1245 Cabrillo Ave - Attachments
1245 Cabrillo Ave - Plans - 01.22.18
Attachments:
1402 Grove Avenue, zoned R-1 - Application for Design Review for a first and second
story addition to an existing single -family dwelling (Jesse Geurse, Geurse Conceptual
Designs, Inc., applicant and designer; Lisa Ley, property owner) (73 noticed) Staff
Contact: Sonal Aggarwal - THIS ITEM HAS BEEN CONTINUED
b.
2683 Summit Drive, zoned R-1 - Application for Design Review, Hillside Area
Construction Permit, Special Permit for building height and Front Setback Variance for a
first and second story addition to an existing single family dwelling (Samaneh Nili, TRG
Architecture + Interior Design, applicant and designer; Sunil and Katherine Koshie,
property owner) (38 noticed) Staff Contact: Sonal Aggarwal
c.
2683 Summit Dr - Staff Report
2683 Summit Dr - Attachments
2683 Summit Dr - Plans - 01.22.18
Attachments:
772 Walnut Avenue, zoned R -1 - Application for Design Review for first and second story
addition to an existing single family dwelling (Jessica Sin, JSD Architecture, applicant and
designer; Vivek and Pooja Shah, property owners) (129 noticed) Staff Contact: Sonal
Aggarwal
d.
772 Walnut Ave - Staff Report
772 Walnut Ave - Attachments
772 Walnut Ave - Plans - 01.22.18
Attachments:
10. COMMISSIONER’S REPORTS
Page 3 City of Burlingame Printed on 1/19/2018
January 22, 2018Planning Commission Meeting Agenda
11. DIRECTOR REPORTS
- Commission Communications
- City Council regular meeting January 16, 2018
12. ADJOURNMENT
Note: An action by the Planning Commission is appealable to the City Council within 10 days of the
Planning Commission's action on January 22, 2018. If the Planning Commission's action has not
been appealed or called up for review by the Council by 5:00 p.m. on February 1, 2018, the action
becomes final. In order to be effective, appeals must be in writing to the City Clerk and must be
accompanied by an appeal fee of $533, which includes noticing costs.
Any writings or documents provided to a majority of the Planning Commission regarding any item on
this agenda will be made available for public inspection during normal business hours at the
Community Development/Planning counter, City Hall, 501 Primrose Road, Burlingame, California.
Page 4 City of Burlingame Printed on 1/19/2018
Hyatt Regency San Francisco Airport, Burlingame, CA January 2018
BCL Project No. 04322 Engineering Assessment
Tent Structural Review
A-1
Photo 1. Overall view of tent structure.
Photo 2. View of typical frame at 10 ft. on center. Arrow indicates knee brace.
Hyatt Regency San Francisco Airport, Burlingame, CA January 2018
BCL Project No. 04322 Engineering Assessment
Tent Structural Review
A-2
Photo 3. View of ceiling of tent structure. Arrow indicates tension cable at frames.
Photo 4. Typical steel cable X-bracing between frames.
Hyatt Regency San Francisco Airport, Burlingame, CA January 2018
BCL Project No. 04322 Engineering Assessment
Tent Structural Review
A-3
Photo 5. Typical base plate with ground stakes.
1
A101
A101
1 SIM
GRAPHIC SYMBOLS
CENTERLINE
WINDOW TAG
WALL TAG
DOOR TAG
KEYNOTE
ROOM TAG
GRID HEAD
LEVEL HEAD
SPOT ELEVATION
SLOPE TRIANGLE
CALLOUT HEAD
SECTION/ ELEVATION
HEAD
INTERIOR ELEVATION
HEAD
REVISION TAG
REVISION CLOUD
NORTH ARROWPROJECT NORTHT
RUE
NORT
H101
Name
ElevationElevation +0.00
1i
Elevation +0.00
Location
1
?06 11 00.D5
1i
0
A101
1
6
4
Room name
ABBREVIATIONS
&And
@ At
(E)Existing
(N)New
ADJ Adjustable
AFF Above Finished Floor
ALUM Aluminum
APPROX Approximately
ARCH Architectural
BLDG Building
BLKG Blocking
BM Beam
BSMT Basement
BDRM Bedroom
BYND Beyond
BOT Bottom
CAB Cabinet
CL Centerline
CLG Ceiling
CLR Clear
CO Cased Opening
COL Column
CONC Concrete
CONT Continuous
CPT Carpet
CLO Closet
CONST Construction
DET Detail
DEPT Department
DBL Double
DEMO Demolish
DIA Diameter
DIM Dimension
DN Down
DR Door
DWG Drawing
DS Downspout
EA Each
EL Elevation
ELEC Electrical
ENG Engineer
EQ Equal
EXT Exterior
FAR Floor Area Ratio
FL Floor
FO Face Of
FND Foundation
FPL Fireplace
GA Gauge
GC General Contractor
GALV Galvanized
GFCI Ground Fault Interrupter
GYP Gypsum
HT Height
HR Hour
HVAC Heating, Ventilating,
And Air Conditioning
ILO In Lieu Of
IN Inch
INSUL Insulation
INT Interior
LO Low
MAT Material
MAX Maximum
MECH Mechanical
MEMBR Membrane
MIN Minimum
MTL Metal
MISC Miscellaneous
N/A Not Applicable
NIC Not In Contract
NTS Not to Scale
NO Number
NOM Nominal
OC On Center
OBS Obscure
OPG Opening
PLUMB Plumbing
PLYWD Plywood
PNT Paint
PBO Provided by owner
RBR Rubber
RCP Reflected Ceiling Plan
REQD Required
RM Room
REFR Refridgerator
RD Roof Drain
SCH Schedule
SECT Section
SF Square Foot
SIM Similar
SPEC Specification
SSTL Stainless Steel
STL Steel
STRUCT Structural
STOR Storage
SSD See Structural Drawings
TBD To Be Determined
TO Top Of
TOC Top Of Curb
TOS Top of Slab
TYP Typical
UON Unless Noted Otherwise
U/S Underside
VIF Verify In Field
W/With
W/O Without
WH Water Heater
WD Wood
WDW Window
DN
DNEEEEEEEEEEEEEEEOOOOOOOOOOOOOOOO
OOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOS SS
G GG
W WW
E EE
D DD
O OO
DN
DNE
EEEEEEEEEEEEEEOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOD DDDDDDD DDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDD50'-0"
N 87' - 11"E -11' - 1 25/32"
+23.40
T.O.C. ELEVATION
24.45
REAR PROPERTY
CORNER ELEVATION
N 62' - 11 21/32"E -54' - 5 3/32"
+26.71
REAR PROPERTY
CORNER ELEVATION
N -40' - 11 31/32"E 5' - 8 3/16"
+24.10
FRONT PROPERTY
CORNER ELEVATION
+21.28
T.O.C. ELEVATION
+21.67
FRONT PROPERTY
CORNER ELEVATION
N -16' - 0 7/16"E 48' - 10"
N -25' - 6"E 54' - 4 1/16"N -50' - 5 13/16"E 11' - 0 11/16"
4'-0"15'-0"15'-0"120'-0"3'-0" 5'-0" 3'-0"20'-0"20'-0"G
4'-0"11'-0"W
E 10'-0"21'-9"10'-0"
4'-0"56'-8"+/-4 1/2" / 12"
+/-4 1/2" / 12"+/-4 1/2" / 12"+/-4 1/2" / 12"+/-4 1/2" / 12"+/-4 1/2" / 12"+/-4 1/2" / 12"+/-4 1/2" / 12"+/-4 1/2" / 12"UTILITY LEGEND
G
S
W
E
WATER METER
SEWER CLEAN OUT
GAS METER
ELECTRICAL METER
BACKFLOW PREVENTION DEVICE
DOWNSPOUT
DIRECTION INDICATOR
WATER LINE
SEWER LINE
GAS LINE
OVERHEAD ELECTRICAL
SERVICE
DRAINAGE LINE
FENCE
B
(E) TREE
(E) SHADE BUSH W/
DIAMETER LESS THAN 6"
SHRUBBERY
ANNUALS
(N) TREE
SOFTSCAPE
CONCRETE
LANDSCAPING LEGEND
50'-0"
4'-0"15'-0"15'-0"120'-0"G
4'-0"
W
E 10'-0"21'-9"10'-0"4'-0"56'-8"4 1/4" / 12"
4 1/4" / 12"+/-4 1/2" / 12"+/-4 1/2" / 12"+/-4 1/2" / 12"+/-4 1/2" / 12"4 1/4" / 12"4 1/4" / 12"4 1/4" / 12"20'-0"20'-0"3'-0" 5'-0" 3'-0"11'-0"
UP
UP
UP
DN
UP
UP
UP
UP
UP
DN
UP
UP
UP
UP
UP
WALL LEGEND
EXISTING WALL
WALL TO BE DEMOLISHED
PROPOSED WALL
1-HR FIRE RATED WALL CONSTRUCTION
AT (E) EXTERIOR FRAMING
NEW WALL W/ 1-HR FIRE RATED
CONSTRUCTION
OVERHEAD ROOF LINE
OUTLINE OF WALLS BELOW
A3.3
1
A3.0
1
A3.2
1
A3.1
1
1
A3.4
2
A3.4 10'-6 1/2"11'-7"38'-8 1/2"3'-9"
4'-3"
11'-6"
EQ EQ
11'-6 1/2"13'-1 1/2"16'-8 1/2"22'-0"9'-9"4'-9"3'-5"3'-9"36'-0"37'-1 1/2"23'-11 1/2"
GARAGE
LAUNDRY/
SEWING ROOM
MEDIA ROOM
STORAGE
BATH 1
STORAGE 3
STORAGE 2
HALL 1
10'-3"
REF.
PATIO
W D
(5'-6" CLG)
(8'-8" CLG)
(7'-6" CLG)
(5'-11" CLG)38'-8 1/2"3'-9"
4'-3"
11'-6"
EQ EQ
11'-6 1/2"13'-1 1/2"16'-8 1/2"22'-0"9'-9"3'-5"3'-9"36'-0"37'-1 1/2"23'-11 1/2"
10'-3"
STORAGE 3
MEDIA ROOM
LAUNDRY/
SEWING ROOM
GARAGE
STORAGE 1
BATH 1
STORAGE 2
PATIO
HALL 1
REF.
W D
(5'-6" CLG)
(8'-8" CLG)
(7'-6" CLG)
(5'-11" CLG)
DN
UP
DN
DN
DN
DN
DN
DN
UP
DN
DN
DN
DN
A3.3
1
A3.0
1
A3.2
1
A3.1
1
1
A3.4
2
A3.4 2'-0"9'-3"
23'-11 1/2"
36'-0"38'-8 1/2"1'-9"15'-2 1/2"37'-1 1/2"12'-3 1/2"
3'-6"EQEQ4'-6"4'-6"48" REF PANTRY
48"
RANGE
DW
12'-3 1/2"21'-0"3'-2 1/2"9'-8"23'-0 1/2"16'-10 3/4"3'-0"EQ EQ
13'-10 1/4"7'-9"EQEQ7'-10 1/4"6'-0"17'-1 1/4"ALIGN
FAMILY ROOM
CLOSET
POWDER
LIVING ROOM
DINING ROOM
FOYER
KITCHEN
HALL 2
LOWER PATIO DECK
UPPER PATIO
FRONT PORCH5'-0"CLEAREQ EQ
WALL LEGEND
EXISTING WALL
WALL TO BE DEMOLISHED
PROPOSED WALL
1-HR FIRE RATED WALL CONSTRUCTION
AT (E) EXTERIOR FRAMING
NEW WALL W/ 1-HR FIRE RATED
CONSTRUCTION
OVERHEAD ROOF LINE
OUTLINE OF WALLS BELOW EQEQKITCHEN
OFFICE
POWDER
LIVING ROOM
DINING ROOM
FRONT PORCH
BREAKFAST
ROOM
FAMILY ROOM
FOYER
DECK
STOR.BR.COATS
EQ EQ 5'-0"CLEAR23'-11 1/2"
36'-0"38'-8 1/2"15'-2 1/2"37'-1 1/2"12'-3 1/2"
3'-6"
12'-3 1/2"21'-0"11'-4"13'-11 3/4"EQ EQ
14'-3"7'-9"
7'-10 1/4"6'-0"17'-1 1/4"PANRY
REF.
11'-3 3/4"5'-11"5'-0"CLEAR
DNDN
A3.3
1
A3.0
1
A3.2
1
A3.1
1
1
A3.4
2
A3.4
8'-0"
1'-0"6'-0 1/2"13'-11 1/2"2'-0"12'-3"11'-10 1/2"12'-8 1/2"9'-11 1/4"10'-4 1/4"2'-4 1/2"6'-5 1/4"12'-5"13'-1 1/4"9'-1 3/4"
EQ EQ
5'-0"
3'-4"2'-0"2'-0"31'-7"5'-4 3/4"9'-6"23'-11 1/2"
12'-4 1/2"
5'-0"8'-8"3'-6"5'-0 1/4"3'-7"
2'-4 1/2"
BEDROOM 3
CLOSET
BEDROOM 2
CLOSET
BATH 3
HALL 3
MASTER
CLOSET
MASTER
BEDROOM
MASTER BATH
2'-5 1/4"
DESK
DESK
9'-2"
8'-4 1/2"3'-0"12'-0"EQ EQ
WALL LEGEND
EXISTING WALL
WALL TO BE DEMOLISHED
PROPOSED WALL
1-HR FIRE RATED WALL CONSTRUCTION
AT (E) EXTERIOR FRAMING
NEW WALL W/ 1-HR FIRE RATED
CONSTRUCTION
OVERHEAD ROOF LINE
OUTLINE OF WALLS BELOW
BEDROOM 3 BEDROOM 2
CLOSET
MASTER BATH
HALL 3
MASTER
BEDROOM
MASTER
CLOSET
BATH 3
CLOSET
LINEN
8'-0"1'-0"6'-0 1/2"14'-5"2'-0"12'-3"
12'-8 1/2"9'-11 1/4"10'-4 1/4"2'-4 1/2"6'-5 1/4"12'-5"13'-1 1/4"
12'-3"
5'-0"3'-4"2'-0"2'-0"31'-7"5'-4 3/4"9'-6"23'-11 1/2"
5'-0"8'-8"3'-6"5'-0 1/4"
3'-7"
2'-4 1/2"
9'-2"
2'-0 1/2"11'-10 1/2"1'-11 3/4"SKYLIGHT
OVERHEAD
SKYLIGHT
OVERHEAD
5'-0"
LOWER LEVEL REAR
OF HOUSE
+20.71
FIRST FL. F.F.
+30.25
SECOND FLOOR F.F.
+40.13
FIRST FLOOR T.O.
PLATE
+39.00
SECOND FL. T.O.
PLATE
+47.63
AVG. TOC BALBOA
+22.34
T.O. RIDGE
+52.34
T.O.S. GARAGE
+21.884'-8 1/2"7'-6"1'-1 1/2"8'-9"8'-4 1/2"1'-2"30'-0"AVG. (E) GRADE ELEVATION
ON PROPERTY LINE AVG. (E) GRADE ELEVATION
ON PROPERTY LINE
+23.47+25.40 12'-0"12'-0"7'-6"7'-6"4 1/2"
12"
LOWER LEVEL REAR
OF HOUSE
+20.71
FIRST FL. F.F.
+30.25
SECOND FLOOR F.F.
+40.13
FIRST FLOOR T.O.
PLATE
+39.00
SECOND FL. T.O.
PLATE
+47.63
AVG. TOC BALBOA
+22.34
T.O. RIDGE
+52.34
T.O.S. GARAGE
+21.88
AVG. (E) GRADE ELEVATION
ON PROPERTY LINE AVG. (E) GRADE ELEVATION
ON PROPERTY LINE
+23.47+25.40 12'-0"12'-0"4'-8 1/2"7'-6"1'-1 1/2"8'-9"8'-4 1/2"1'-2"30'-0"7'-6"7'-6"4 1/4"
12"
4 1/4"
12"
4 1/2"
12"
+/-
LOWER LEVEL REAR
OF HOUSE
+20.71
FIRST FL. F.F.
+30.25
SECOND FLOOR F.F.
+40.13
FIRST FLOOR T.O.
PLATE
+39.00
SECOND FL. T.O.
PLATE
+47.63
AVG. TOC BALBOA
+22.34
T.O. RIDGE
+52.34
T.O.S. GARAGE
+21.88 4'-8 1/2"7'-6"1'-1 1/2"8'-9"9'-6 1/2"30'-0"LOWER LEVEL REAR
OF HOUSE
+20.71
FIRST FL. F.F.
+30.25
SECOND FLOOR F.F.
+40.13
FIRST FLOOR T.O.
PLATE
+39.00
SECOND FL. T.O.
PLATE
+47.63
AVG. TOC BALBOA
+22.34
T.O. RIDGE
+52.34
30'-0"T.O.S. GARAGE
+21.88 4'-8 1/2"7'-6"1'-1 1/2"8'-9"9'-6 1/2"MAX.5'-10 1/2"
LOWER LEVEL REAR
OF HOUSE
+20.71
FIRST FL. F.F.
+30.25
SECOND FLOOR F.F.
+40.13
FIRST FLOOR T.O.
PLATE
+39.00
SECOND FL. T.O.
PLATE
+47.63
AVG. TOC BALBOA
+22.34
T.O. RIDGE
+52.34
4'-8 1/2"7'-6"1'-1 1/2"8'-9"9'-6 1/2"AVG. (E) GRADE ELEVATION
ON PROPERTY LINEAVG. (E) GRADE ELEVATION
ON PROPERTY LINE
+23.47 +25.4012'-0"12'-0"7'-6"7'-6"+/-4'-8 1/2"30'-0"LOWER LEVEL REAR
OF HOUSE
+20.71
FIRST FL. F.F.
+30.25
SECOND FLOOR F.F.
+40.13
FIRST FLOOR T.O.
PLATE
+39.00
SECOND FL. T.O.
PLATE
+47.63
AVG. TOC BALBOA
+22.34
T.O. RIDGE
+52.34
4'-8 1/2"7'-6"1'-1 1/2"8'-9"9'-6 1/2"AVG. (E) GRADE ELEVATION
ON PROPERTY LINEAVG. (E) GRADE ELEVATION
ON PROPERTY LINE
+23.47 +25.4012'-0"12'-0"7'-6"7'-6"30'-0"
LOWER LEVEL REAR
OF HOUSE
+20.71
FIRST FL. F.F.
+30.25
SECOND FLOOR F.F.
+40.13
FIRST FLOOR T.O.
PLATE
+39.00
SECOND FL. T.O.
PLATE
+47.63
AVG. TOC BALBOA
+22.34
T.O. RIDGE
+52.34
30'-0"4'-8 1/2"7'-6"1'-1 1/2"8'-9"9'-6 1/2"LOWER LEVEL REAR
OF HOUSE
+20.71
FIRST FL. F.F.
+30.25
SECOND FLOOR F.F.
+40.13
FIRST FLOOR T.O.
PLATE
+39.00
SECOND FL. T.O.
PLATE
+47.63
AVG. TOC BALBOA
+22.34
T.O. RIDGE
+52.34
4'-8 1/2"7'-6"1'-1 1/2"8'-9"9'-6 1/2"30'-0"
LOWER LEVEL REAR
OF HOUSE
+20.71
FIRST FL. F.F.
+30.25
SECOND FLOOR F.F.
+40.13
FIRST FLOOR T.O.
PLATE
+39.00
SECOND FL. T.O.
PLATE
+47.63
AVG. TOC BALBOA
+22.34
T.O. RIDGE
+52.34
30'-0"4'-8 1/2"7'-6"9'-10 1/2"7'-11"1'-7 1/2"FAMILY ROOM
MEDIA ROOM
BEDROOM 2
HALL 3
FOYER
HALL 1
STORAGE
HALL 2
5'-11"5'-11"11'-2 1/2"8'-8"8'-9"7'-6"7'-6"8'-0"LOWER LEVEL REAR
OF HOUSE
+20.71
FIRST FL. F.F.
+30.25
SECOND FLOOR F.F.
+40.13
FIRST FLOOR T.O.
PLATE
+39.00
SECOND FL. T.O.
PLATE
+47.63
AVG. TOC BALBOA
+22.34
T.O. RIDGE
+52.34
30'-0"STORAGE 3
MEDIA ROOMLAUNDRY/
SEWING ROOM
FAMILY ROOM
MASTER
CLOSET
HALL 3
BATH 3
KITCHEN 8'-9"5'-6"1'-7 1/2"7'-11"9'-10 1/2"7'-6"4'-8 1/2"8'-8"A3.4
3
5'-6"3'-7"5'-6"8"
City of Burlingame
Conditional Use Permit and Parking Variance
Address: 1669 Bayshore Highway, Unit B Meeting Date: January 22, 2018
Request: Application for Conditional Use Permit for a commercial recreation use (CrossFit studio) and Parking
Variance.
Applicant: Craig Ranier Gadduang, Marvelous Performance APN: 026-302-530
Architect: Blaise Descollonges, RSS Architecture Lot Area: 52,898 SF
Property Owner: 1669 & 1699 Bayshore LLC Zoning: IB
Bayfront Specific Plan: Office and Warehouse; Bayshore Overlay Area
Environmental Review Status: The project is Categorically Exempt from review pursuant to the California
Environmental Quality Act (CEQA), per Section 15301 (a) which states that Interior or exterior alterations
involving such things as interior partitions, plumbing, and electrical conveniences are exempt from environmental
review.
Project History: This application is the result of code enforcement complaints about the business due to its
operating in a location where their use is not permitted . Prior to operating business at the current location, the
applicant opened a CrossFit (commercial recreation) studio at 384 Beach Road, zoned APS (Anza Point South),
in January 2014. Commercial recreation uses are prohibited in the APS Zoning District (Code Section 25.49.030
(f)). Based on a complaint and partial inspection conducted at the site, a Code Enforcement case (#CE14-0109)
was opened on December 22, 2014 for operating in a non-permitted zone. A letter (dated January 5, 2015) was
sent to the property owner, from the former Code Compliance Officer, to notify them about the violation.
In October 2016, the current Code Compliance Officer took over the case. The applicant made contact with the
Planning Division to seek out other site locations within the City that permits commercial recreation uses. Only
the SL (Shoreline Area) Zoning District permits commercial recreation uses by-right. Other zoning districts where
commercial recreation is allowed require a Conditional Use Permit, and in many instances also require a Parking
Variance depending on the nature of the site and building . Based on a deadline provided by the Code
Compliance Officer, the applicant moved out of 384 Beach Road in December 2016.
The Planning Division was notified in early March 2017 that a CrossFit studio was operating at 1669 Bayshore
Highway, zoned IB (Inner Bayshore). Based on this complaint, a code enforcement case was opened on March
13, 2017 (#CE17-0026) and a ‘Notice of Violation’ (dated March 13, 2017) was sent to the applicant and property
owner. In the IB Zoning District, commercial recreation uses with a Conditional Use Permit are allowed to
operate at properties that have frontage on Bayshore Highway (Code Section 25.43.045 (b)(3)). The parcel has
frontages on both Bayshore Highway and Stanton Road. On March 16, 2017, the applicant submitted Planning
application fees for a Conditional Use Permit and Parking Variance; a completed application to the Planning
Commission and plans were submitted on April 13, 2017.
Project Description: The applicant, Craig Ranier Gadduang of Marvelous Performance, is requesting a
Conditional Use Permit and Parking Variance to operate a CrossFit studio at 1669 Bayshore Highway, zoned IB.
The existing multi-tenant building consists of three tenant spaces/units and two tenants : the applicant (Unit B,
commercial recreation use) and Joe’s Café (Unit A, food establishment/restaurant use). The third tenant space
(Unit C) is vacant. Prior to Marvelous Performance, the furniture store business Repo Depot occupied both Units
Item No. 7a
Regular Action
Items
Conditional Use Permit and Parking Variance 1669 Bayshore Highway
2
B and C from 1981 until it closed operations in 2014 .
Please refer to the attached Letter of Explanation and the Commercial Application to review the proposed
commercial recreation use and the proposed hours. The applicant notes that the CrossFit studio offers both
small group classes (60 minutes long for each class session) and personal training. T he current and projected
maximum number of employees (full-time and part-time) that would be on-site at any one time is 8 to 12 and the
current and projected maximum number of clients on-site at any one time is 25 to 30 for a total maximum of 33 to
42 people on-site at any one time. The applicant also indicates that the business intends to remain at 1669
Bayshore Highway, Unit B for a duration less than 5 years.
There are a total of 57 on-site parking spaces which includes 1 ADA compliant parking space; of this total, 19
on-site parking spaces are designated for Marvelous Performance (includes the 1 ADA compliant parking
space). With the proposed use, a total of 76 on -site parking spaces are required where 48 on -site parking
spaces were required for the previous uses. The applicant is requesting a 28-space Parking Variance. Please
refer to the table below for a breakdown of the uses and par king required on-site.
The applicant is requesting approval of the following applications:
Conditional Use Permit for a commercial recreation use (CrossFit studio proposed) (Code Section
25.43.045(b)(3)); and
Parking Variance for an incremental increase in the number of parking spaces required on-site due to
the conversion of warehouse space to a commercial recreation use (increase of 28 spaces) (Code
Section 25.70.040).
This space intentionally left blank.
Conditional Use Permit and Parking Variance 1669 Bayshore Highway
3
1669 Bayshore Highway
Lot Area: 52,898 SF Plans date stamped: September 1, 2017
PREVIOUS/EXISTING PROPOSED ALLOWED/REQ’D
Use :
(includes total
SF, parking
ratio, and
parking
required)
Unit A (Joe’s Café)
restaurant
1,864 SF (1:200 SF, 10
spaces)
Unit B (formerly Repo
Depot)
office
1,516 SF (1:300 SF, 6
spaces)
storage
164 SF (1:1,000 SF, 1
space)
warehouse
7,330 SF (1:1,000 SF, 8
spaces)
Unit C (formerly Repo
Depot)
furniture store
13,526 SF (1:600 SF, 23
spaces)
Unit A (Joe’s Café)
no change
Unit B (Marvelous
Performance)1
office
1,467 SF (1:300 SF, 5
spaces)
storage
213 SF (1:1,000 SF, 1
space)
warehouse
153 SF (1:1,000 SF, 1
space)
commercial recreation
7,177 SF (1:200 SF, 36
spaces)
Unit C (formerly Repo
Depot)
no change, currently vacant
commercial recreation
use allowed with a
Conditional Use Permit
if located on a property
with frontage on
Bayshore Highway
(Code Section
25.43.045 (b)(3)).1
Parking: 48 spaces required (in total) 76 spaces required (in total) Variance required for
intensification of use
(28 parking space
increase)
Total On-Site
Parking:
58 spaces provided
57 spaces provided
(including 1 ADA space)
existing uses: 48
spaces
proposed uses: 76
spaces
Staff Comments: See attached memos from the Engineering, Building, Fire, Parks, a nd Stormwater Divisions.
Conditional Use Permit and Parking Variance 1669 Bayshore Highway
4
Study Meeting: At the Planning Commission study meeting on November 13, 2017, the Commission had a few
questions regarding this application (November 13, 2017 Planning Commission Minutes attached). The following
is a summary of the Commission’s questions and respective responses:
Were any of the code enforcement complaints related to parking?
None of the complaints were related to parking. Code enforcement is primarily due to the fact that the business
was operating in a zoning district where commercial recreation use is not permitted without a Conditional Use
Permit.
What is the justification for the Variance?
The applicant has conducted their own parking survey to demonstrate that the parking on -site is sufficient for
their use. Please see the applicant’s response letter and parking photos in the attachments.
How many people are on site on a typical day?
At the Study meeting, the applicant stated that class sizes are limited and that there is a range of 10 -20 people in
each class. The applicant has also pulled attendance records over specific time periods and found that the
overall average class size is less than 15 people; most classes have an average attendance of 10 people or
less. For more detail, please see applicant’s resp onse letter and attendance reports in the attachments.
Findings for a Conditional Use Permit: In order to grant a Conditional Use Permit, the Planning Commission
must find that the following conditions exist on the property (Code Section 25.52.020, a -c):
(a) The proposed use, at the proposed location, will not be detrimental or injurious to property or
improvements in the vicinity and will not be detrimental to the public health, safety, general welfare or
convenience;
(b) The proposed use will be located and conducted in a manner in accord with the Burlingame general plan
and the purposes of this title;
(c) The planning commission may impose such reasonable conditions or restrictions as it deems necessary
to secure the purposes of this title and to ass ure operation of the use in a manner compatible with the
aesthetics, mass, bulk and character of existing and potential uses on adjoining properties in the general
vicinity.
Required Findings for Parking Variance: In order to grant a Parking Variance the Planning Commission must
find that the following conditions exist on the property (Code Section 25.54.020 a -d):
(a) there are exceptional or extraordinary circumstances or conditions applicable to the property involved
that do not apply generally to property in the same district;
(b) the granting of the application is necessary for the preservation and enjoyment of a substantial property
right of the applicant, and to prevent unreasonable property loss or unnecessary hardship;
(c) the granting of the application will not be detrimental or injurious to property or improvements in the
vicinity and will not be detrimental to the public health, safety, general welfare or convenience; and
(d) that the use of the property will be compatible with the aesthetics , mass, bulk and character of existing
and potential uses of properties in the general vicinity.
Conditional Use Permit and Parking Variance 1669 Bayshore Highway
5
Suggested Variance Findings (Parking): That the proposed commercial recreation use operates in a less
intense manner than typical gymnasiums because it will be used for personal training and will therefore generate
less traffic and fewer parking needs. The other existing tenant on the site has been made aware of the
application and supports the use. Operating before and after main hours of neighboring busine sses, the
attendance reports, and the parking survey indicate available on -site parking during the hours of operation
proposed for the commercial recreation use and that the site can therefore accommodate the proposed use.
Planning Commission Action: The Planning Commission should conduct a public hearing on the application,
and consider public testimony and the analysis contained within the staff report. Action should include specific
findings supporting the Planning Commission’s decision, and should be affirmed by resolution of the Planning
Commission. The reasons for any action should be stated clearly for the record. At the public hearing the
following conditions should be considered:
1. that the project shall be built as shown on the plans submitted to the Planning Division date stamped
September 1, 2017, sheets A0.0 through A4.0; and that the business owner shall apply for a Burlingame
Business License prior to submitting to the Building Division for the required Building permit;
2. that any changes to the size or envelope of building, which would include changing or adding exterior
walls or parapet walls or increasing the size of the mezzanine, shall require an amendment to this
conditional use permit;
3. that any changes in operation, floor area, use, number of employees, or number of customers shall
require an amendment to this use permit;
4. that demolition or removal of the existing structures and any grading or earth moving on the site shall not
occur until a building permit has been issued and such s ite work shall be required to comply with all the
regulations of the Bay Area Air Quality Management District;
5. that the project shall comply with the Construction and Demolition Debris Recycling Ordinance which
requires affected demolition, new constructi on and alteration projects to submit a Waste Reduction plan
and meet recycling requirements; any partial or full demolition of a structure, interior or exterior, shall
require a demolition permit;
6. that if the structure is demolished or the envelope chang ed at a later date, or if the use in the existing
space is changed, the parking variance as well as any other exceptions to the code granted here will
become void; and
7. that the project shall meet all the requirements of the California Building and Unif orm Fire Codes, 2013
Edition, as amended by the City of Burlingame.
‘Amelia Kolokihakaufisi
Associate Planner
c. Craig Ranier Gadduang, Marvelous Performance, applicant
Blaise Descollonges, RSS Architecture , architect
Conditional Use Permit and Parking Variance 1669 Bayshore Highway
6
Attachments:
November 13, 2017 Planning Commission Minutes
Applicant’s Response Letter
Parking Photos
Attendance Reports
Updated Commercial Application
Letter of Support from Joe’s Cafe
Application to the Planning Commission
Commercial Application
Letter of Explanation from Applicant
Conditional Use Permit Application
Parking Variance Application
Staff Comments
Planning Commission Resolution (Proposed)
Notice of Public Hearing – Mailed November 3, 2017
Aerial Photo
City of Burlingame
Design Review and Special Permit
Address: 1245 Cabrillo Avenue Meeting Date: January 22, 2018
Request: Application for Design Review and Special Permit for building height for a first and second story addition
to an existing single family dwelling and new detached garage.
Applicant and Designer: Chu Design Associates APN: 026-171-050
Property Owners: Eric and Jennifer Lai Lot Area: 6,119 SF
General Plan: Low Density Residential Zoning: R-1
Project Description: The existing two-story house and two-story detached accessory structure contain 2,793 SF
(0.46 FAR) of floor area. The applicant is proposing to demolish the existing accessory structure, build a new
detached garage and add onto the first and second floors of the existing house. The proposed project will increase
the total floor area to 3,257 SF (0.53 FAR), where 3,278 SF (0.53 FAR) is the maximum allowed. The project is 21
SF below the maximum allowable floor area and is therefore within 1% of the maximum allowed FAR.
The roof ridge of the existing house measures 30’-2” above average top of curb. The applicant is proposing to
match the existing roof ridge at the addition. Therefore, a request for a Special Permit is required for overall
building height (30’-2” proposed where between 30’-0” and 36’-0” is allowed with a Special Permit).
The existing house has four bedrooms and there is no change in the number of bedrooms with this project. Two
parking spaces, one of which must be covered, are required on-site. One covered parking space is provided in the
new detached garage (10’ x 20’ clear interior dimensions); one uncovered parking space (9’ x 20’) is provided in the
driveway. All other Zoning Code requirements have been met.
Planning staff would note that Easton Creek runs along the rear of the property. The existing two-story accessory
structure, which contains a garage and storage areas, will be removed as a part of this project. A portion of the rear
of the accessory structure extends beyond the top of creek bank (see sheets A.2.1 and Topographic Survey Plan).
No improvements are proposed beyond the top of bank after the accessory structure is removed. The proposed
detached garage is located above the top of bank (see sheets A.2 and L1.0).
The application includes removing a protected size Lawson cypress (Port Orford cedar), measuring 35.8 inches in
diameter and located in the rear third of the lot. The arborist report, prepared by Kielty Arborist Services (Kielty),
dated December 15, 2017 (attached), notes that the tree is in fair condition and that “the poor location of the tree
being surrounded by non-pervious paving has caused the aggressive surface roots to cause severe damage to the
property”.
In order for it to be located above the top of creek bank, the new detached garage is proposed to be built closer to
the cypress tree than the existing garage. This will require severing a high percentage of surface roots, resulting in
35-40% root loss and causing a poor performing unstable tree. Kielty notes that “impacts to the tree will be
moderate to severe with decline expected in the tree” and that “root loss will also reduce the structural integrity of
the tree.” Kielty recommends removing the existing cypress tree and replacing it with a red maple or Chinese
pistache or comparable tree planted in a location where it will thrive without damaging the new detached garage.
Two new Japanese maple trees, one at the front and one at the rear of the site, are proposed on the site (see
Landscape Plan, sheet L1.0).
In his memo dated December 27, 2017, the City Arborist notes that an application for a Protected Tree Removal
Permit to remove the cypress tree “was denied in December 2016 because the tree was in good condition and there
was no effort to explore a means to preserve the tree and eliminate tripping hazard”. His memo also acknowledges
Item No. 9a
Design Review Study
Design Review and Special Permit 1245 Cabrillo Avenue
2
that an application is now being proposed on the site that would adversely affect the tree and notes that “the tree
will most likely be approved for removal since the demolition and construction of the new garage and patio will
damage the roots and cause the tree to decline.”
A Protected Tree Removal Permit will be required for removal of the cypress tree. The City Arborist notes that it will
not be effective until the Planning Commission review and approves the project.
The applicant is requesting the following applications:
Design Review for a first and second story addition to an existing single family dwelling and new detached
garage (C.S. 25.57.010 (a) (2)); and
Special Permit for overall building height (30’-2” existing and proposed where between 30’-0” and 36'-0" is
allowed with a Special Permit) (C.S. 25.26.060 (a) (1)).
1245 Cabrillo Avenue
Lot Area: 6,119 SF Plans date stamped: January 8, 2018
EXISTING PROPOSED ALLOWED/REQ'D
SETBACKS
Front (1st flr):
(2nd flr):
17'-1"
19’-7”
no change
no change
18'-9" (block average)
20'-0"
Side (left):
(right):
1'-6" ¹
10'-6"
no change (1st floor)
8’-4” (2nd floor)
11’-3” (1st floor)
10’-6” (2nd floor)
4'-0"
4'-0"
Rear (1st flr):
(2nd flr):
39'-0"
65’-0”
40’-7”
49'-7"
15'-0"
20'-0"
Lot Coverage: 2498 SF
40.8%
2420 SF
39.5%
2447 SF
40%
FAR: 2793 SF
0.46 FAR
3257 SF
0.53 FAR
3278 SF ²
0.53 FAR
# of bedrooms: 4 4 ---
Off-Street Parking: 1 covered
1 uncovered
1 covered
(10’ x 20')
1 uncovered
(9' x 20')
1 covered
(10' x 20')
1 uncovered
(9' x 20')
Building Height: 30'-2" 30'-2" ³ 30'-0"
DH Envelope: complies complies C.S. 25.26.075
¹ Existing nonconforming left side setback.
² (0.32 x 6,119 SF) + 1100 SF + 220 SF = 3,278 SF (0.53 FAR)
³ Special Permit requested for overall building height (30’-2” existing and proposed where between
30’-0” and 36'-0" is allowed with a Special Permit).
Design Review and Special Permit 1245 Cabrillo Avenue
3
Staff Comments: See attached memos from the Parks and Engineering Divisions.
Ruben Hurin
Senior Planner
c. Chu Design Associates, applicant and designer
Eric and Jennifer Lai, property owners
Attachments:
Application to the Planning Commission
Special Permit Application
Report Prepared by Kielty Arborist Services, dated December 15, 2017
Staff Comments
Notice of Public Hearing – Mailed January 12, 2018
Aerial Photo
N 34°56'16" E 119.87'N 34°56'16" E 124.87'S 55°03'44" E25.00'S 34°56'16" W5.00'S 55°03'44" E 25.00'S 55°03'44" E 50.00'464746464646454445444
4
4343434242426"PRIVET32"CEDAR13"BIRCH6"PEAR12"PRUNUS8"ESCALLONIA16"PITTOSPORUM12"PITTOSPORUM8"RHUS8"RHUS8"RHUS8"RHUS18"GINKGO222222233336444668857777533311111111111111111111111111111188333BAG1G1G1RESIDENCE(E)GARAGE(N)C A B R I L L O A V E N U E50' R.O.W.(E)LAWN(N)UNIT PAVERDRIVEWAYCONCRETE(N)UNIT PAVERDRIVEWAYCONCRETE(E)VEGETATION(E)LAWN(E)PORCH(E)PORCH(E) FENCINGTO REMAIN(E) FENCINGTO REMAINADJACENTBUILDINGADJACENTBUILDING(E) WALLTO REMAIN(N) WOODFENCING*MATCH (E)(E) EVERGREENTREES(E) FENCINGTO REMAIN(E) TREESTO REMAIN(E) WATERMETER(E) CONCRETESIDEWALK(E) BIRCHTREE TOREMAIN(E) TREESTO REMAIN(E) CEDARTREE TO BEREMOVED(E) FENCINGTO REMAIN(E) STEPS(E) LANDING /STEPS(E) VEGETATION(E) CONCRETEDRIVEWAY APRON46474646464645444544444343434242
42RESIDENCE(E)GARAGE(N)C A B R I L L O A V E N U E50' R.O.W.ADJACENTBUILDINGADJACENTBUILDING(E)IRRIGATION(E)IRRIGATION(N) VALVE*CONNECT TO (E)IRRIGATION MAINLINEL1.0DATE:NOVEMBER 21, 2017SCALE: 1/8" = 1'-0"LANDSCAPE PLANTITLE:SHEET NO:PLANLANDSCAPEREVISIONSLAI RESIDENCE
1245 CABRILLO AVE. BURLINGAME, CALIFORNIASCALE: 1/8" = 1'-0"IRRIGATION PLANPLANTING NOTES1. LANDSCAPE CONTRACTOR SHALL VERIFY PLANT AND SOD QUANTITIES PRIOR TO SUBMITTING BID FOR WORK.2. ALL PLANT MATERIAL SHALL COMPLY WITH THE LATEST STANDARDS OF NURSERY STOCK, PUBLISHED BY THE AMERICAN NURSERY & LANDSCAPEASSOCIATION.3. PLANT MATERIAL CANNOT BE GUARANTEED AS DEER RESISTANT DUE TO CHANGING HABITS OF DEER.4. ALL PLANTING AREAS SHALL BE COVERED WITH A LAYER OF BARK MULCH TO A MINIMUM DEPTH OF 2 INCHES, WITH A CHIP SIZE OF NO LESS THANONE INCH. A 2 INCH LAYER OF GREENWASTE MULCH UNDER THE BARK MULCH IS RECOMMENDED.5. SOIL AMENDMENTS SHALL BE USED AS NECESSARY. SOIL AMENDMENT SHALL BE FREE OF DEBRIS. ROCKS LARGER THAN ONE INCH DIAMETERWILL NOT BE PERMITTED. SOIL AMENDMENTS ARE NOT PERMITTED IN TYPICAL NATIVE PLANT LANDSCAPE AREAS.6. PLANTING HOLES SHALL GENERALLY BE 2x - 3x THE SIZE OF THE ROOT BALL. THE WALLS AND BASES OF PLANT HOLES SHALL BE SCARIFIED.HOLES SHALL BE BACKFILLED WITH 5% ORGANIC COMPOST & 95% EXISTING SOIL. PLANTING HOLES OF NATIVE PLANT MATERIAL SHOULD BEINOCULATED WITH MYCORRHIZAL FUNGI, PER MANUFACTURER'S SPECS.7. TREES SHALL BE STAKED WITH TWO PRESSURE TREATED 2" DIA. POLES. TREE TRUNK SHALL BE SECURED WITH TWO RUBBER TIES OR STRAPSFORMING A FIGURE-EIGHT BETWEEN TRUNK AND STAKE.8. RESIDUAL WEED PRE-EMERGENT SHALL BE APPLIED BY THE CONTRACTOR AS NECESSARY. APPLICATION SHALL BE ACCORDING TOMANUFACTURER'S INSTRUCTIONS.9. LAWN SHALL NOT BE INSTALLED ON SLOPES GREATER THAN 25%. ALL TURF AREAS SHALL BE FERTILIZED AT TIME OF INSTALLATION.RAINBIRD XERI-POP W/ MPR NOZZLEHUNTER MPR40 BODY W/ MP ROTATOR SERIES30-55(C)-CORNER, (1)-1000 etc.(5)-5 SERIES, (8)-8 SERIESCL(L)-LEFT, (S)-SIDE, (R)-RIGHTRAINBIRD XERI-POP W/ SQ NOZZLE(Q)-QUARTER, (H)-HALF, (F)-FULL5FILTER / PRESSURE REGULATORFEBCO 825Y REDUCED PRESSURE ASSEMBLYPVC SCH 40 SLEEVINGIRRIGATION LEGENDDESCRIPTIONPVC SCH 40 LATERAL PIPINGPVC SCH 40 MAINLINEIRRITROL 100 SERIES CONTROL VALVESHUT-OFF VALVESYMUNDER ALL PAVING / WALLS AS NEEDED PER MFR'S SPECSSIZING TBD BY CONTRACTORW/ GLOBE VALVEW/ SHUT-OFF VALVESBRASS BALL VALVEREMARKSSEE PLAN FOR SIZINGW/ WEATHER STATIONWEATHERMATIC SMARTLINE SERIES CONTROLLERHOSEBIB30" TALL BRASS LINE & FIXTURE60-10030-55--60-10060-100-175 max.PSI30-5510-3060-10020-5020-50RAINBIRD XERI-BUBBLER SPIKE *NOT SHOWNAS NEEDED, SEE DETAIL15-30-INSTALL PER MFR'S SPECSHUNTER MPR40 BODY W/ MP STRIP SERIESGPM.07-2.63.14-.55-----.02-.41.13-.52.02-.22------QSIZING TBD BY CONTRACTORIRRIGATION METHODWATER USE(SPY: SPRAY DRP: DRIP BUB: BUBBLER SUB: SUB-SURFACE)(VL: VERY LOW L: LOW M: MEDIUM H: HIGH MX: MIXED)MXDRPNETAFIM TECHLINE CV DRIPLINENETAFIM TECHLINE CV (SUBSURFACE)IRRIGATION NOTES1. THE CONCEPTS ON THE IRRIGATION PLAN ARE SCHEMATIC MINIMUM REQUIREMENTS, THE FULL EXTENT OF WHICH ARE TO BE DETERMINED BY THECONTRACTOR. THE CONTRACTOR SHALL MAKE ADJUSTMENTS AS NECESSARY BASED ON ACTUAL SITE CONDITIONS.2. ALL IRRIGATION SYSTEM COMPONENTS SHALL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. MANUFACTURER'S SPECIFICATIONSSUPERSEDE ANY SPECS ON THESE PLANS / DETAILS.3. IRRIGATION SYSTEM SHALL USE PRESSURE REGULATORS AS NEEDED TO KEEP ALL COMPONENTS WITHIN OPTIMAL PSI RANGE, PERMANUFACTURER'S SPECS.4. CONTROLLER TYPE SHALL BE A SMART CONTROLLER. RAIN SENSORS AND / OR WEATHER STATIONS ARE RECOMMENDED.5. CONTROLLER SHALL BE SET TO IRRIGATE BETWEEN THE HOURS OF 8PM AND 10AM. CONTROLLER SHALL BE SET TO IRRIGATE DEEPLY AND LESSFREQUENTLY TO ENCOURAGE DROUGHT RESISTANT ROOT GROWTH. IRRIGATION SCHEDULE TO BE DETERMINED BY AUDITOR / CONTRACTOR.6. PIPING BETWEEN THE WATER METER AND A REDUCED PRESSURE ASSEMBLY SHALL BE BRASS OR COPPER TYPE 'K'.7. THE BOTTOM OF THE REDUCED PRESSURE ASSEMBLY SHALL BE INSTALLED MIN. 12" ABOVE THE GROUND.8. A 100 MESH FILTER SHALL BE INSTALLED ON THE MAINLINE BEFORE THE REDUCED PRESSURE ASSEMBLY.9. VALVES SHALL BE HOUSED IN WEATHER-PROOF PLASTIC BOXES, WITH LOCKABLE LIDS MARKED WATER.10. CONTROL WIRE CONNECTIONS SHALL BE MADE WITH WATERPROOF PLASTIC WIRE NUTS.11. MAIN SUPPLY LINES & FITTINGS SHALL BE PVC SCH 40, SIZE AS NOTED ON PLAN, BURIED 12" - 16" DEEP.12. LATERAL SUPPLY LINES & FITTINGS SHALL BE PVC SCH 40, SIZE TO BE DETERMINED BY CONTRACTOR, BURIED 9" - 12" DEEP.13. FLEXIBLE POLY PIPE TO BE 12" -34", DETERMINED BY CONTRACTOR . ALL 14" FLEXIBLE DISTRIBUTION LINES TO BE A MAXIMUM OF 5'-0" IN LENGTH& ARE TO BE STAKED.14. BUBBLERS SHALL BE SPACED TO CREATE AN EVEN WET ZONE ABOUT THE SIZE OF THE CANOPY OF ALL NEW SHRUBS, NEW TREES & EXISTINGIMMATURE NON-NATIVE TREES. BUBBLERS SHALL BE PLACED TO AVOID AS MUCH AS POSSIBLE IRRIGATING OAK TREES & ANY OTHER EXISTING,MATURE NATIVE OR DROUGHT TOLERANT PLANTS.15. HOSE BIBS SHALL BE MOUNTED ON GALVANIZED STEEL RISERS 30" ABOVE FINISHED GRADE. SECURE TO A #4 STEEL BAR DRIVEN 18" INTOSOLID GROUND.16. CHECK VALVES SHALL BE INSTALLED ON ALL DOWNHILL DRIPLINE & DISTRIBUTION LINE.17. RISER HEIGHT IN LAWN AREAS SHALL BE 4". RISER HEIGHT IN MEADOW AREAS AND OTHER LANDSCAPE AREAS SHALL BE 12". THE RISERS FORSPRINKLERS ON SLOPES SHALL BE SET APPROXIMATELY PERPENDICULAR TO THE PLANE OF THE SLOPE.18. IF LOCATION OF A SUPPLY LINE INTERFERES WITH THE DRILLING OF THE PLANT HOLES, THE PLANT HOLES SHALL BE LOCATED AS TO CLEAR THESUPPLY LINES.18. ALL LINES SHALL BE THOROUGHLY FLUSHED OUT PRIOR TO ATTACHMENT OF VALVES, SPRINKLERS, EMITTERS, & OTHER TERMINAL FITTINGS.19. THE CONTRACTOR SHALL MAKE FINAL ADJUSTMENTS TO THE IRRIGATION SYSTEM TO ENSURE PROPER COVERAGE AND PREVENT WATER RUN-OFFAND EXCESS SPRAY.20. ALL SPRAY AND DRIP ZONES TO BE MIN. 5'-0" AND PREFERABLY 10'-0" AWAY FROM OAK TREE TRUNKS.7/31/19
PROJECT LOCATION
2683 Summit Drive
Item No. 9c
Design Review Study
City of Burlingame
Design Review, Special Permit and Variance
Address: 2683 Summit Drive Meeting Date: January 22, 2018
Request: Design Review for the new second-story, Special Permit for height, and Variance for front setback of
the second-story addition.
Applicant and Designer: Samaneh Nili, TRG Architects+ Interior Design APN: 029-182-140
Property Owners: Sunil and Katherine Koshie Lot Area: 10,164 SF
General Plan: Low Density Residential Zoning: R-1
Project Description: The subject property is located on Summit Drive on the second lot from the corner in the
Hillside Area Construction Region . The site is located on a sloping lot, which slopes from back to front with a
grade difference of 15 feet from the average at the rear property line (112.76’) to the average top of the curb
(97.85’). The applicant proposes to extend the kitchen, family room and living room on the first-floor and move
the master bedroom on the second-floor. The proposed project will contain a living/dining room, a family room,
an office and a guest bedroom on the first-floor and three (3) bedrooms on the second floor, making it a total of
four (4) bedrooms in the house.
The total proposed floor area of the project is 3711 SF (0.36 FAR), where 4352 SF (0.42 FAR) is the maximum
allowed (including covered porch exemptions). The proposed house is 641 SF below the maximum allowed floor
area and 1626 SF below the maximum permissible lot coverage, where 2444 SF (24%) is the lot coverage
proposed and 4070 SF (40%) is the maximum allowed as per the code.
The existing front setback of the house is 24’-6” and there is a block average of 46’-0” on Summit Drive. The new
second-story is proposed to be built keeping the same setback as the existing f irst-story 24’-6”, and therefore,
the applicant requests for a Variance to the second-story front setback requirement. All other setbacks comply.
The proposed height is 35’-11” and an application for Special Permit for height greater than 30 feet is also
requested for the project.
The existing house has three (3) bedrooms and would increase to four (4) bedrooms, which requires two parking
spaces, one of which must be covered. The house has an existing two (2) car attached garage with (clear
interior dimensions 19’-4 ½” X 19’-5”) and therefore meets the current parking code requirements, which requires
one covered (10’-0” X 20’-0”) space and one uncovered (9’-0” X 20’-0”) parking space. A new driveway is also
proposed with the construction, which would remove three trees from the front yard (one 8” Oak, one 12” Oak
and one 17” multi-trunk Pine). These are not protected trees. All other Zoning Code requirements have been
met.
The applicant requests the following applications:
▪ Design Review for a second story addition (C.S. 25.57.010 (a) (2));
▪ Variance for front setback for the second-story which is less than block average of 46’-0” (C.S. 25.26.072
(3)); and
▪ Special Permit for building height between thirty (30) and thirty-six (36) feet (35’-5” proposed) (C.S.
25.26.060 (a) (1)).
Item No. 9c
Design Review Study
Design Review, Special Permit and Variance 2683 Summit Drive
-2-
2683 Summit Drive
Lot Area: 10,164 SF Plans date stamped: January 5, 2018
EXISTING PROPOSED ALLOWED/REQ'D
SETBACKS
Front (1st flr):
(2nd flr):
24'-6"
---
24'-6"
24'-6" 1
15'-0" or block average
46'-0" (block average)
Side (left):
(right):
10'-0"
10’-0”
7’ 2 3/8”
10’-0”
7'-0"
7'-0"
Rear (1st flr):
(2nd flr):
35’-1 ½”
---
35’- 1 ½”
35’-1 ½”
15'-0"
20'-0"
Lot Coverage: 2,430 SF
23.9%
2,444 SF
24%
4,070 SF 2
40%
FAR: 2,250 SF
0.22 FAR
3,711 SF
0.36 FAR
4,352 SF 3
0.42 FAR
# of bedrooms: 3 4 ---
Parking: 2 covered
(19-4 ½” x 19'-5”)
1 uncovered
No change
1 covered
(10' x 20')
1 uncovered
(9' x 20')
Height: 26'- 5 7/8” 35'-11" 4 30'-0"
DH Envelope: --- complies CS 25.26.075
1 Variance required for second-story front setback less than the block average of 46’.
2 (0.40 X 10,164 SF) = 4,070 SF (40%)
3 (0.32 x 10,164 SF) + 1100 SF = 4,352 SF (0.42 FAR).
4 Special Permit required for height greater than 30’-0”.
Staff Comments: See attached memos from the Chief Building Official, Fire Division, Engineering Division,
Parks Division, and Stormwater Division.
Design Review Criteria: The criteria for design review as established in Ordinance No. 1591 adopted by the
Council on April 20, 1998 are outlined as follows:
1. Compatibility of the architectural style with that of the existing character of the neighborhood;
2. Respect for the parking and garage patterns in th e neighborhood;
3. Architectural style and mass and bulk of structure;
4. Interface of the proposed structure with the structures on adjacent properties; and
5. Landscaping and its proportion to mass and bulk of structural components.
Design Review, Special Permit and Variance 2683 Summit Drive
-3-
Required Findings for Variance: In order to grant a Variance, the Planning Commission must find that the
following conditions exist on the property (Code Section 25.54.020 a -d):
(a) there are exceptional or extraordinary circumstances or conditions applicable to the pr operty involved
that do not apply generally to property in the same district;
(b) the granting of the application is necessary for the preservation and enjoyment of a substantial property
right of the applicant, and to prevent unreasonable property loss o r unnecessary hardship;
(c) the granting of the application will not be detrimental or injurious to property or improvements in the
vicinity and will not be detrimental to the public health, safety, general welfare or convenience; and
(d) that the use of the property will be compatible with the aesthetics, mass, bulk and character of existing
and potential uses of properties in the general vicinity.
Findings for a Special Permit: In order to grant a Special Permit, the Planning Commission must find that the
following conditions exist on the property (Code Section 25.51.020 a -d):
(a) The blend of mass, scale and dominant structural characteristics of the new construction or addition are
consistent with the existing structure's design and with the existing street and neighborhood;
(b) The variety of roof line, facade, exterior finish materials and elevations of the proposed new structure or
addition are consistent with the existing structure, street and neighborhood;
(c) The proposed project is consistent with the residential design guidelines adopted by the city; and
(d) Removal of any trees located within the footprint of any new structure or addition is necessary and is
consistent with the city's reforestation requirements, and the mitigation for the removal that is proposed is
appropriate.
Sonal Aggarwal
Contract Planner
c. Samaneh Nilli, applicant and architect
Sunil and Katherien Koshie, property owners
Attachments:
Application to the Planning Commission
Variance Form
Special Permit Form
Staff Comments
Notice of Public Hearing – Mailed January 12, 2018
Aerial Photo
1014 Howard Ave, San Mateo, CA 94401 ● 650.579.5762 voice ● 650.579.0115 fax ● admin@trgarch.com
January 10, 2018
Planning Commission
City of Burlingame
501 Primrose Road
Burlingame, CA 94010
Re: 2683 Summit Dr.
Dear Commissioner,
Thank you for reviewing this proposal to remodel the house at 2683 Summit Dr. This is a deceptively
tricky site to work with, and we have strived to find the best composition of elements possible. The project
requirement for a special permit for height due to topography, and setback variance to b uild on top of the
existing footprint, are addressed in the other write-ups, and will be covered in detail at the meeting.
For the owners, the most concerning issue with the is the dangerous existing driveway. In its current
configuration, it is extremely steep, and backing out is hazardous for both the residents and those driving
on Summit. There is virtually no visibility for one when backing out right into a blind curve where traffic
certainly moves at least at the speed limit. We studied numerous options to improve the situation;
lowering the garage to lessen the slope of the driveway, moving the garage to the other side of the house
etc… What we are proposing is to lengthen the driveway in order to reduce its pitch, and enter into
Summit Dr. further away from the blind curve to improve visibility for all.
There has been an ongoing effort to reach out to immediate neighbors, to share the plans, and assess
any potential impacts; especially the neighbor to the left. The owners of 2683 Summit (this proje ct) left a
letter with their contact information early on in the design process. Once plans were developed, a
complete set of drawings, including 3D images, was delivered to the neighbor with additional contact
information.
Thanks for taking the time to review this project. We look forward to the meeting.
Sincerely,
Randy Grange AIA LEED AP
Project Address: 2683 Summit Drive, zoned R-1, APN: 027-224-020
Description: Request for Design Review and Hillside Area Construction Permit for a first
and second floor addition to an existing single-story house and Special
Permit for building height.
From: Christine Reed
Fire Dept.
Please address the following comments at this time; provide a written response and revised
plans with your resubmittal:
The following comments do not need to be addressed now, but you should be aware of them as
they will need to be addressed at time of building permit submittal:
Provide a residential fire sprinkler system throughout the residence:
1. Provide a 1-inch water meter or size to accommodate sprinkler system flow demand.
2. Provide a backflow prevention device/double check valve assembly – A schematic of water
lateral line after meter shall be shown on Building permit plans prior to approval indicating location of
the device after the split between domestic and fire protection lines.
3. Drawings submitted to Building Department for review and approval shall clearly indicate fire
sprinklers shall be installed under a separate deferred fire permit, approved by the Fire Department
prior to installation.
4. Fire flow shall meet requirements of Calif ornia Fire Code Appendix B. Contact Burlingame
Engineering Department for fire flow information.
Reviewed By: Christine Reed Date: 11/11/17
650-558-7617
Project Comments – Planning Application
Project Address: 2683 Summit Drive, zoned R-1, APN: 027-224-020
Description: Request for Design Review and Hillside Area Construction Permit for a first
and second floor addition to an existing single-story house and Special
Permit for building height.
From: Carolyn Critz
Stormwater
Please address the following comments at this time; provide a written response and revised
plans with your resubmittal:
Project does not create or replace >2,500 square feet of impervious surface or use architectural
copper. Nothing further needed at this time.
The following comments do not need to be addressed now, but you should be aware of them as
they will need to be addressed at time of building permit submittal.
1. Any construction project in the City, regardless of size, shall comply with the city’s stormwater
NPDES permit to prevent construction activity stormwater pollution. Project proponents shall
ensure that all contractors implement appropriate and effective Best Management Practices
(BMPs) during all phases of construction, including demolition. When submitting plans for a
building permit, please include a list of construction BMPs as project notes, preferably on a
separate full size (2’x 3’ or larger) plan sheet. A downloadable electronic file is available at:
http://www.flowstobay.org/Construction under Construction BMP Brochures: Construction
BMP Plan Sheet.
For further assistance regarding stormwater, please contact Carolyn Critz, Environmental Compliance
Manager, at (650) 342 3727, ext. 118, or carolyn.critz@veolia.com
Reviewed By: Carolyn Critz Date: November 7, 2017
(650) 342 3727, ext. 118
Project Comments – Planning Application
Project Address: 2683 Summit Drive, zoned R-1, APN: 027-224-020
Description: Request for Design Review and Hillside Area Construction Permit for a first
and second floor addition to an existing single-story house and Special
Permit for building height.
From: Martin Quan
Public Works Engineering
Please address the following comments at this time; provide a written response and revised
plans with your resubmittal:
1. No comments at this time.
The following comments do not need to be addressed now, but you should be aware of them as they will need to
be addressed at time of building permit submittal.
1. Based on the scope of work, this is a “Type II” project that requires a Stormwater Construction Pollution
Prevention Permit. This permit is required prior to issuance of a Building Permit. An initial field inspection is
required prior to the start of any construction (on private property or in the public right-of-way).
2. Any work in the City right-of-way, such as placement of debris bin in street, work in sidewalk area, public
easements, and utility easements, is required to obtain an Encroachment Permit prior to starting work.
3. Construction hours in the City Public right-of-way are limited to weekdays and non-City Holidays between
8:00 a.m. and 5:00 p.m. for all activities (including hauling).
4. The project shall comply with the City’s NPDES permit requirements to prevent storm water pollution.
5. Replace damaged and displaced curb, gutter and/or sidewalk fronting site.
6. All water lines connections to city water mains for services or fire line protection are to be installed per city
standard procedures and material specifications. Contact the city Water department for connection fees. If
required, all fire services and services 2" and over will be installed by buil der. All underground fire service
connections shall be submitted as separate Underground Fire Service permit for review and approval.
7. Sewer Backwater Protection Certification is required for the installation of any new sewer fixture per
Ordinance No. 1710. The Sewer Backwater Protection Certificate is required prior to the issuance of Building
Permit.
8. The sanitary sewer lateral (building sewer) shall be tested per ordinance code chapter 15.12. Testing
information is available at the Building department counter. A Sewer Lateral Test encroachment permit is
required.
9. Insert the ‘Best Management Practices’, updated June 2014, construction sheet into the plans set. A copy can
be found at http://www.flowstobay.org/sites/default/files/Countywide%20Program%20BMP%20Plan%20Sheet -
June%202014%20Update.pdf#overlay-context=brochures or http://www.flowstobay.org/brochures then click
“construction bmp plan sheet”
Reviewed By: Martin Quan Date: 11/9/17
650-558-7245
Project Comments – Planning Application
Project Address: 2683 Summit Drive, zoned R-1, APN: 027-224-020
Description: Request for Design Review and Hillside Area Construction Permit for a first
and second floor addition to an existing single-story house and Special
Permit for building height.
From: Bob Disco
Parks Division
Please address the following comments at this time; provide a written response and revised
plans with your resubmittal:
1. No further comments.
The following comments do not need to be addressed now, but you should be aware of them as they
will need to be addressed at time of building permit submittal.
Reviewed By: BD Date: 12.14.17
650.558.7330
Project Comments –
Planning Application
Project Address: 2683 Summit Drive, zoned R-1, APN: 027-224-020
Description: Request for Design Review and Hillside Area Construction Permit for a first
and second floor addition to an existing single-story house and Special
Permit for building height.
From: Rick Caro III
Building Division
Please address the following comments at this time; provide a written response and revised
plans with your resubmittal:
No Comment
The following comments do not need to be addressed now, but you should be aware of them as
they will need to be addressed at time of building permit submittal.
7) Provide lighting at all exterior landings. Was not shown on plan / sheet A2.1 per comment
response from applicant. Note: that I did not see a legend or sign table indicating what would
represent the exterior lighting being provided. Also the elevation drawings did not reflect that
there were exterior lighting provided.
10) As of January 1, 2014, SB 407 (2009) requires non-compliant plumbing fixtures to be replaced
by water-conserving plumbing fixtures when a property is undergoing alterations or
improvements. This law applies to all residential and commercial property built prior to
January 1, 1994. Details can be found at http://www.leginfo.ca.gov/pub/09-
10/bill/sen/sb_0401-0450/sb_407_bill_20091011_chaptered.html. Revise the plans to
show compliance with this requirement.
11) Provide two completed copies of the Mandatory Measures with the submittal of your plans for
Building Code compliance plan check. In addition, replicate this completed document on the
plans. Note: On the Checklist you must provide a reference that indicates the page of the plans
on which each Measure can be found.
12) When you submit your plans to the Building Division for plan review provide a completed
Supplemental Demolition Permit Application. NOTE: The Demolition Permit will not be
issued until a Building Permit is issued for the project.
Reviewed By: Rick Caro III Date: December 27, 2017
650 558-7270
Project Comments – Planning Application
2683 Summit Drive, R-1
2683 SUMMIT DRIVEA D D I T I O N A N D R E M O D E LA0.0COVER SHEETPROPOSED SITE PLANA1.1EXISTING FLOOR PLANA2.0EEXISTING ROOF PLANA2.01EPROP0SED FIRST FLOOR PLANA2.1A2.2PROPOSED ROOF PLANA2.3TRG ARCHITECTS, INC.1014 HOWARD AVENUE,SAN MATEO, CA 94401650.579.5762 tel650.579.0115 faxCIVIL ENGINEERPRECISION ENGINEERING901 WALTERMIRE ST.BELMONT, CA 94002415.743.0527 teltlutze@gmail.comARCHITECTSURVEYORB & H SURVEYING, INC.901 WALTERMIRE ST.BELMONT, CA 94002650.637.1590 tel650.637.1059 faxSUBJECT PROPERTY2683 SUMMIT DR.BURLINGAME, CA94010027-224-02010,164 SF4,066 sf4,352 sfPROJECT ADDRESS:OWNER: SUNIL & KATHERINE KOSHIEPARCEL NUMBER:LOT AREA:MAX. LOT COVER (40%):MAX. FLOOR AREA (32%+1,100)1,847.14 sf402.6 sf86 sf1151.36 sf70 sf-70 sf3,487 sfPROPOSED FLOOR AREA:(E) 1st FLOOR:(E) GARAGE: (N) ADDITION:(N) 2nd FLOOR:(N) COVERED PORCH:(200sf exemption)TOTAL FLOOR AREA:1847.14 sf86 sf70 sf402.6 sf-48 sf2358 sf23.2 %PROPOSED LOT COVERAGE:(E) HOUSE(N) ADDITION (STAIRWELL+SEATING AREA)(N) PORCH ENTRANCE(E) GARAGE:(E) ENTRY STAIRS(N) TOTAL LOT COVERAGE:LOT COVERAGE %:A1SheetsOfSheet:Status:REVISIONSNo.RevisionsChecked By:Date:Job:Appr.DateByScale:Drawn by:Consultant(s):FAX 650.579.0115E-Mail: admin@trgarch.com650.579.5762Architect:San Mateo, California 944011014 Howard Avenue1/16" = 1'-0"GRAPHIC SCALES:5'01/8" = 1'-0"3/16" = 1'-0"50'05'25'01'15'3/4" = 1'-0"1" = 1'-0"04'01'3'3" = 1'-0"IF THIS SHEET IS NOT 36"x24" , IT ISA REDUCED PRINT - SCALE ACCORDINGLY01'1/4" = 1'-0"01'12'5'10'5'10'1'1-1/2" = 1'-0"02'1'These plans are copyrighted and are subject to copyright protection as an"architectural work" under Sec. 102 of the Copyright Act, 17 U.S.O. asamended December 1990 and known as Architectural Works CopyrightProtection Act of 1990. This protection includes, but is not limited to theoverall form as well as the arrangement and composition of spaces andelements of the design. Under such protection, unauthorized use ofthese plans, work, or project represented, can legally result in thecessation of construction or building being seized and/or monetarycompensation to TRG Architects.Project:Owner(s):Sheet Contents:AS NOTEDTRG10-31-2017PLANNING SUBMITTALPROP0SED SECOND FLOOR PLANEXISTING & PROPOSED FRONT ELEVATIONA3.1A3.2A3.3A3.4EXISTING & PROPOSED LEFT ELEVATIONEXISTING & PROPOSED REAR ELEVATIONEXISTING & PROPOSED RIGHT ELEVATIONC0.1SITE SURVEYEXISTING SITE PLANA1.0A4.1SECTION12-04-17CAPLANNING COMMENTS12-22-17CAPLANNING COMMENTSL1.0LANDSCAPE PLAN1,847.14 sf402.6 sf126+48+6 sf2,430 sfEXISTING LOT COVERAGE:(E) HOUSE(E) GARAGE:(E) PORCH & ENTRANCE STEPS:1,847.14 sf402.6 sf48 sf126+6=132 sf-132 sf2298 sfEXISTING FLOOR AREA:(E) 1st FLOOR:(E) GARAGE(E) ENTRANCE STEPS(E) PORCH (200sf exemption)01-05-18CAPLANNING COMMENTS
SheetsOfSheet:Status:REVISIONSNo.RevisionsChecked By:Date:Job:Appr.DateByScale:Drawn by:Consultant(s):FAX 650.579.0115E-Mail: admin@trgarch.com650.579.5762Architect:San Mateo, California 944011014 Howard Avenue1/16" = 1'-0"GRAPHIC SCALES:5'01/8" = 1'-0"3/16" = 1'-0"50'05'25'01'15'3/4" = 1'-0"1" = 1'-0"04'01'3'3" = 1'-0"IF THIS SHEET IS NOT 36"x24" , IT ISA REDUCED PRINT - SCALE ACCORDINGLY01'1/4" = 1'-0"01'12'5'10'5'10'1'1-1/2" = 1'-0"02'1'These plans are copyrighted and are subject to copyright protection as an"architectural work" under Sec. 102 of the Copyright Act, 17 U.S.O. asamended December 1990 and known as Architectural Works CopyrightProtection Act of 1990. This protection includes, but is not limited to theoverall form as well as the arrangement and composition of spaces andelements of the design. Under such protection, unauthorized use ofthese plans, work, or project represented, can legally result in thecessation of construction or building being seized and/or monetarycompensation to TRG Architects.Project:Owner(s):Sheet Contents:AS NOTEDTRG10-31-2017PLANNING SUBMITTAL12-04-17CAPLANNING COMMENTS12-22-17CAPLANNING COMMENTS01-05-18CAPLANNING COMMENTS
SheetsOfSheet:Status:REVISIONSNo.RevisionsChecked By:Date:Job:Appr.DateByScale:Drawn by:Consultant(s):FAX 650.579.0115E-Mail: admin@trgarch.com650.579.5762Architect:San Mateo, California 944011014 Howard Avenue1/16" = 1'-0"GRAPHIC SCALES:5'01/8" = 1'-0"3/16" = 1'-0"50'05'25'01'15'3/4" = 1'-0"1" = 1'-0"04'01'3'3" = 1'-0"IF THIS SHEET IS NOT 36"x24" , IT ISA REDUCED PRINT - SCALE ACCORDINGLY01'1/4" = 1'-0"01'12'5'10'5'10'1'1-1/2" = 1'-0"02'1'These plans are copyrighted and are subject to copyright protection as an"architectural work" under Sec. 102 of the Copyright Act, 17 U.S.O. asamended December 1990 and known as Architectural Works CopyrightProtection Act of 1990. This protection includes, but is not limited to theoverall form as well as the arrangement and composition of spaces andelements of the design. Under such protection, unauthorized use ofthese plans, work, or project represented, can legally result in thecessation of construction or building being seized and/or monetarycompensation to TRG Architects.Project:Owner(s):Sheet Contents:AS NOTEDTRG10-31-2017PLANNING SUBMITTALSOUTH ELEVATION ELEVATION 7'-0" FROM PROPERTY LINETOTAL WALL AREA, 7 FEET FROM PROPERTY LINE: 858 SQFT75.25 SQFTTOTAL OPENING AREA:PERCENTAGE ALLOWED PER 2016 CBC, TABLE 705.8: 25%PERCENTAGE PROPOSED: 8.9%PERCENTAGE ALLOWED PER 2016 CRC, TABLE R302.1(1) FOR WALLS BEYOND 5 FEET: UNLIMITED12-04-17CAPLANNING COMMENTS12-22-17CAPLANNING COMMENTS01-05-18CAPLANNING COMMENTS
SheetsOfSheet:Status:REVISIONSNo.RevisionsChecked By:Date:Job:Appr.DateByScale:Drawn by:Consultant(s):FAX 650.579.0115E-Mail: admin@trgarch.com650.579.5762Architect:San Mateo, California 944011014 Howard Avenue1/16" = 1'-0"GRAPHIC SCALES:5'01/8" = 1'-0"3/16" = 1'-0"50'05'25'01'15'3/4" = 1'-0"1" = 1'-0"04'01'3'3" = 1'-0"IF THIS SHEET IS NOT 36"x24" , IT ISA REDUCED PRINT - SCALE ACCORDINGLY01'1/4" = 1'-0"01'12'5'10'5'10'1'1-1/2" = 1'-0"02'1'These plans are copyrighted and are subject to copyright protection as an"architectural work" under Sec. 102 of the Copyright Act, 17 U.S.O. asamended December 1990 and known as Architectural Works CopyrightProtection Act of 1990. This protection includes, but is not limited to theoverall form as well as the arrangement and composition of spaces andelements of the design. Under such protection, unauthorized use ofthese plans, work, or project represented, can legally result in thecessation of construction or building being seized and/or monetarycompensation to TRG Architects.Project:Owner(s):Sheet Contents:AS NOTEDTRG10-31-2017PLANNING SUBMITTALEXIT WINDOW CHARTWINDOW NET CLEAR AREA, HEIGHT & WIDTH260" X 60"12-04-17CAPLANNING COMMENTS12-22-17CAPLANNING COMMENTS01-05-18CAPLANNING COMMENTS
SheetsOfSheet:Status:REVISIONSNo.RevisionsChecked By:Date:Job:Appr.DateByScale:Drawn by:Consultant(s):FAX 650.579.0115E-Mail: admin@trgarch.com650.579.5762Architect:San Mateo, California 944011014 Howard Avenue1/16" = 1'-0"GRAPHIC SCALES:5'01/8" = 1'-0"3/16" = 1'-0"50'05'25'01'15'3/4" = 1'-0"1" = 1'-0"04'01'3'3" = 1'-0"IF THIS SHEET IS NOT 36"x24" , IT ISA REDUCED PRINT - SCALE ACCORDINGLY01'1/4" = 1'-0"01'12'5'10'5'10'1'1-1/2" = 1'-0"02'1'These plans are copyrighted and are subject to copyright protection as an"architectural work" under Sec. 102 of the Copyright Act, 17 U.S.O. asamended December 1990 and known as Architectural Works CopyrightProtection Act of 1990. This protection includes, but is not limited to theoverall form as well as the arrangement and composition of spaces andelements of the design. Under such protection, unauthorized use ofthese plans, work, or project represented, can legally result in thecessation of construction or building being seized and/or monetarycompensation to TRG Architects.Project:Owner(s):Sheet Contents:AS NOTEDTRG10-31-2017PLANNING SUBMITTALEXIT WINDOW CHARTWINDOW NET CLEAR AREA, HEIGHT & WIDTH136" X 60" CHART OF OPENINGWEST ELEVATION ELEVATION 7'-0" FROM PROPERTY LINETOTAL WALL AREA, 7 FEET FROM PROPERTY LINE: 858 SQFT58.5 SQFTTOTAL OPENING AREA:PERCENTAGE ALLOWED PER 2016 CBC, TABLE 705.8: 45%PERCENTAGE PROPOSED: 8.9%PERCENTAGE ALLOWED PER 2016 CRC, TABLE R302.1(1) FOR WALLS BEYOND 5 FEET: UNLIMITED12-04-17CAPLANNING COMMENTS12-22-17CAPLANNING COMMENTS01-05-18CAPLANNING COMMENTS
SETBACK LINE12"OAK12"CLUSTER18"CLUSTER12"CLUSTER14"CLUSTER24"CLUSTER12"TREE30"CLUSTER15"CLUSTER15"CLUSTER12"CLUSTER7" ORANGE TREE8" TREE OAKSheetsOfSheet:Status:REVISIONSNo.RevisionsChecked By:Date:Job:Appr.DateByScale:Drawn by:Consultant(s):FAX 650.579.0115E-Mail: admin@trgarch.com650.579.5762Architect:San Mateo, California 944011014 Howard Avenue1/16" = 1'-0"GRAPHIC SCALES:5'01/8" = 1'-0"3/16" = 1'-0"50'05'25'01'15'3/4" = 1'-0"1" = 1'-0"04'01'3'3" = 1'-0"IF THIS SHEET IS NOT 36"x24" , IT ISA REDUCED PRINT - SCALE ACCORDINGLY01'1/4" = 1'-0"01'12'5'10'5'10'1'1-1/2" = 1'-0"02'1'These plans are copyrighted and are subject to copyright protection as an"architectural work" under Sec. 102 of the Copyright Act, 17 U.S.O. asamended December 1990 and known as Architectural Works CopyrightProtection Act of 1990. This protection includes, but is not limited to theoverall form as well as the arrangement and composition of spaces andelements of the design. Under such protection, unauthorized use ofthese plans, work, or project represented, can legally result in thecessation of construction or building being seized and/or monetarycompensation to TRG Architects.Project:Owner(s):Sheet Contents:AS NOTEDTRG10-31-2017PLANNING SUBMITTAL12-04-17CAPLANNING COMMENTS12-22-17CAPLANNING COMMENTS01-05-18CAPLANNING COMMENTS
REMODELED RESIDENCEAPN: 027-224-020LOT AREA: 10,164 sfPROPERTY LINESETBACK LINE12"OAK12"CLUSTER18"CLUSTER12"CLUSTER14"CLUSTER24"CLUSTER12"TREE30"CLUSTER15"CLUSTER15"CLUSTER12"CLUSTER7" ORANGE TREE8" TREE OAKSheetsOfSheet:Status:REVISIONSNo.RevisionsChecked By:Date:Job:Appr.DateByScale:Drawn by:Consultant(s):FAX 650.579.0115E-Mail: admin@trgarch.com650.579.5762Architect:San Mateo, California 944011014 Howard Avenue1/16" = 1'-0"GRAPHIC SCALES:5'01/8" = 1'-0"3/16" = 1'-0"50'05'25'01'15'3/4" = 1'-0"1" = 1'-0"04'01'3'3" = 1'-0"IF THIS SHEET IS NOT 36"x24" , IT ISA REDUCED PRINT - SCALE ACCORDINGLY01'1/4" = 1'-0"01'12'5'10'5'10'1'1-1/2" = 1'-0"02'1'These plans are copyrighted and are subject to copyright protection as an"architectural work" under Sec. 102 of the Copyright Act, 17 U.S.O. asamended December 1990 and known as Architectural Works CopyrightProtection Act of 1990. This protection includes, but is not limited to theoverall form as well as the arrangement and composition of spaces andelements of the design. Under such protection, unauthorized use ofthese plans, work, or project represented, can legally result in thecessation of construction or building being seized and/or monetarycompensation to TRG Architects.Project:Owner(s):Sheet Contents:AS NOTEDTRG10-31-2017PLANNING SUBMITTAL12-04-17CAPLANNING COMMENTS12-22-17CAPLANNING COMMENTS01-05-18CAPLANNING COMMENTS
PROPERTY LINESETBACK LINE12"OAK12"CLUSTER18"CLUSTER12"CLUSTER14"CLUSTER24"CLUSTER12"TREE30"CLUSTER15"CLUSTER15"CLUSTER12"CLUSTER7" ORANGE TREE8" TREE OAKSheetsOfSheet:Status:REVISIONSNo.RevisionsChecked By:Date:Job:Appr.DateByScale:Drawn by:Consultant(s):FAX 650.579.0115E-Mail: admin@trgarch.com650.579.5762Architect:San Mateo, California 944011014 Howard Avenue1/16" = 1'-0"GRAPHIC SCALES:5'01/8" = 1'-0"3/16" = 1'-0"50'05'25'01'15'3/4" = 1'-0"1" = 1'-0"04'01'3'3" = 1'-0"IF THIS SHEET IS NOT 36"x24" , IT ISA REDUCED PRINT - SCALE ACCORDINGLY01'1/4" = 1'-0"01'12'5'10'5'10'1'1-1/2" = 1'-0"02'1'These plans are copyrighted and are subject to copyright protection as an"architectural work" under Sec. 102 of the Copyright Act, 17 U.S.O. asamended December 1990 and known as Architectural Works CopyrightProtection Act of 1990. This protection includes, but is not limited to theoverall form as well as the arrangement and composition of spaces andelements of the design. Under such protection, unauthorized use ofthese plans, work, or project represented, can legally result in thecessation of construction or building being seized and/or monetarycompensation to TRG Architects.Project:Owner(s):Sheet Contents:AS NOTEDTRG10-31-2017PLANNING SUBMITTAL12-04-17CAPLANNING COMMENTS12-22-17CAPLANNING COMMENTS01-05-18CAPLANNING COMMENTS
Item No. 9d
Design Review Study City of Burlingame
Design Review
Address: 772 Walnut Avenue Meeting Date: January 22, 2018
Request: Application for Design Review for first and second-story addition to an existing single-family dwelling
Applicant and Architect: Jessica Sin, JSD Architecture + Interiors APN: 281-141-200
Property Owner: Vivek and Pooja Shah Lot Area: 9,015 SF
General Plan: Low Density Residential Zoning: R-1
Project Description: The subject property is located on an interior lot and is surrounded by single-family
houses. The applicant proposes to expand the kitchen and add a family room and patio by adding 202 SF on the
first- floor and expand the master bedroom on the second -floor by adding 204 SF. The total proposed floor area
of the project is 3,922 SF (0.43 Floor Area Ratio, FAR), where 3,985 SF (0.44 FAR) is the maximum allowed per
code. The proposed project is 63 SF below the maximum allowed floor area and 815 SF below the maximum
allowed lot coverage, with 2,791 SF (31%) proposed, where 3,606 SF (40%) is the maximum allowed lot
coverage per code (CS 25.26.065).
The existing house has a non-conforming left side setback (0-11”), which will be maintained during the
construction. All other setback requirements have been met.
The proposal will reduce the bedroom count from six (6) to five (5) bedrooms. The house will include one
bedroom, one family and a dining room on the first-floor and four (4) bedrooms on the second-floor. The code
requires two (2) covered and one (1) uncovered parking spaces for houses with more than four (4) bedrooms.
The existing house has a one-car garage that is non-conforming because the site requires 2 covered side-by-
side and 1 uncovered space. However, as the bedroom count reduces from six (6) to five (5) bedrooms, the
project may retain the existing non-conforming parking since the number of bedrooms is not increasing . The
interior dimensions of the garage will be modified with the project t o provide space for a new pantry and mud
room; however, a clear internal space of 10’-0” X 20’-0” is maintained to meet the parking requirement. One
uncovered parking space (10’-0” x 20’-0”) is provided in the driveway. All other Zoning Code requirements have
been met.
The applicant is requesting the following:
Design Review for second-story addition (C.S. 25.57.010 (a)(2));
772 Walnut Avenue
Lot Size: 9,015 SF Plans date stamped: January 9, 2018
EXISTING PROPOSED ALLOWED/REQ’D
SETBACKS
Front (1st flr): 19’-8 ¼” No change 15’-0” or block average
(2nd flr): 19’-8 ¼” No change 20'-0"or block average
Side (left):
(right):
0’-11” 1
5’-10”
No change
4’-10 ½”
4'-0"
4'-0"
Rear (1st flr):
(2nd flr):
67’-0 ¼”
67’-0 ¼”
67’-0 ¼”
100’-5”
15'-0"
20'-0"
Lot Coverage: 2253 SF
24%
2791 SF
31%
3606 SF 2
40%
Design Review 772 Walnut Avenue
2
772 Walnut Avenue
Lot Size: 9,015 SF Plans date stamped: January 9, 2018
EXISTING PROPOSED ALLOWED/REQ’D
FAR: 3516
0.39 FAR
3922 SF
0.43 FAR
3985 SF 3
0.44 FAR
# of bedrooms: 6 5 ---
Off-Street Parking:
1 covered (10’X20’) 4
1 uncovered (10’X20’)
1 covered (10’X20’)
1 uncovered (10’X20’)
2 covered (20’x20’)
1 uncovered (9'x20')
Height: 28’-0” 28’-0” 30'-0"
DH Envelope: Doesn’t comply complies CS 25.26.075
1 Existing non-conforming side setback
2 (0.40 x 9015 SF) = 3606 SF (40%)
3 (0.32 x 9015 SF) + 1100 SF = 3985 SF (0.44 FAR)
4 Existing non-conforming one car garage
Staff Comments: See attached memos from the Engineering, Building, Fire, Parks and Stormwater Divisions.
Design Review Criteria: The criteria for design review as established in Ordinance No. 1591 adopted by the
Council on April 20, 1998 are outlined as follows:
1. Compatibility of the architectural style with that of the existing character of the neighborhood;
2. Respect for the parking and garage patterns in the neighborhood;
3. Architectural style and mass and bulk of structure;
4. Interface of the proposed structure with the structures on adjacent properties; and
5. Landscaping and its proportion to mass and bulk of structural components.
Sonal Aggarwal
Contract Planner
c. Jessica Sin, applicant
Vivek and Pooja Shah, property owner
Attachments:
Application to the Planning Commission
Staff Comments
Notice of Public Hearing – Mailed January 12, 2018
Aerial Photo
Project Address: 772 Walnut Avenue, zoned R-1, APN: 028-141-200
Description: Request for Design Review for a first and second story addition to an
existing two-story house.
From: Christine Reed
Fire Dept.
Please address the following comments at this time; provide a written response and revised
plans with your resubmittal:
1. BBQ unit providing an open flame shall be installed at least 15’ from the structure or provide fire
wall construction separation between the structure and BBQ unit that also provides both
horizontal and vertical separation from the unit, based on manufacturer’s specifications.
12/21/17 – Item addressed.
The following comments do not need to be addressed now, but you should be aware of them as
they will need to be addressed at time of building permit submittal:
Provide a residential fire sprinkler system throughout the residence:
1. Provide a 1-inch water meter or size to accommodate sprinkler system flow demand.
2. Provide a backflow prevention device/double check valve assembly – A schematic of water
lateral line after meter shall be shown on Building permit plans prior to approval indicating location of
the device after the split between domestic and fire protection lines.
3. Drawings submitted to Building Department for review and approval shall clearly indicate fire
sprinklers shall be installed under a separate deferred fire permit, approved by the Fire Department
prior to installation.
4. Fire flow shall meet requirements of California Fire Code Appendix B. Contact Burlingame
Engineering Department for fire flow information.
Reviewed By: Christine Reed Date: 12/21/17
650-558-7617
Project Comments – Planning Application
Project Address: 772 Walnut Avenue, zoned R-1, APN: 028-141-200
Description: Request for Design Review for a first and second story addition to an
existing two-story house.
From: Martin Quan
Public Works Engineering
Please address the following comments at this time; provide a written response and revised
plans with your resubmittal:
1. On the site plan, please show the location of all the existing or proposed locations for utilities (PG&E, water,
sewer, and sewer cleanout).
2. Please relocate or remove the existing brick retaining wall that is within the City’s right-of-way to the property
line.
3. No further comments at this time.
The following comments do not need to be addressed now, but you should be aware of them as they will need to
be addressed at time of building permit submittal.
4. Based on the scope of work, this is a “Type I” project that requires a Stormwater Construction Pollution
Prevention Permit. This permit is required prior to issuance of a Building Permit. An initial field inspection is
required prior to the start of any construction (on private property or in the public right-of-way).
5. Any work in the City right-of-way, such as placement of debris bin in street, work in sidewalk area, public
easements, and utility easements, is required to obtain an Encroachment Permit prior to starting work.
6. Construction hours in the City Public right-of-way are limited to weekdays and non-City Holidays between
8:00 a.m. and 5:00 p.m. for all activities (including hauling).
7. The project shall comply with the City’s NPDES permit requirements to prevent storm water pollution.
8. Replace damaged and displaced curb, gutter and/or sidewalk fronting site.
9. All water lines connections to city water mains for services or fire line protection are to be installed per ci ty
standard procedures and material specifications. Contact the city Water department for connection fees. If
required, all fire services and services 2" and over will be installed by builder. All underground fire service
connections shall be submitted as separate Underground Fire Service permit for review and approval.
10. Sewer Backwater Protection Certification is required for the installation of any new sewer fixture per
Ordinance No. 1710. The Sewer Backwater Protection Certificate is required prior to the issuance of Building
Permit.
11. The sanitary sewer lateral (building sewer) shall be tested per ordinance code chapter 15.12. Testing
information is available at the Building department counter. A Sewer Lateral Test encroachment permit is
required.
12. Insert the ‘Best Management Practices’, updated June 2014, construction sheet into the plans set. A copy can
be found at http://www.flowstobay.org/sites/default/files/Countywide%20Program%20BMP%20Plan%20Sheet -
June%202014%20Update.pdf#overlay-context=brochures or http://www.flowstobay.org/brochures then click
“construction bmp plan sheet”
Reviewed By: Martin Quan Date: 12/18/17
650-558-7245
Project Comments – Planning Application
Project Address: 772 Walnut Avenue, zoned R-1, APN: 028-141-200
Description: Request for Design Review for a first and second story addition to an
existing two-story house.
From: Rick Caro III
Building Division
Please address the following comments at this time; provide a written response and revised
plans with your resubmittal:
No Comment
The following comments do not need to be addressed now, but you should be aware of them as
they will need to be addressed at time of building permit submittal.
11) On the plans show that all openings in exterior walls, both protected and unprotected, will
comply with 2016 CBC, Table 705.8. Provide a table or chart that specifies 1) the openings
allowed and; 2) the size and percentage of the openings proposed. Note: The percentages of the
windows for the project are not reflected in the chart. At the time of the building permit
submittal, show that the opening percentages allowed comply with the building code and also
show that the size and percentages meet natural lighting and ventilation.
14) Provide two completed copies of the Mandatory Measures with the submittal of your plans for
Building Code compliance plan check. In addition, replicate this completed document on the plans.
Note: On the Checklist you must provide a reference that indicates the page of the plans on which
each Measure can be found.
Reviewed By: Rick Caro III Date: December 13, 2017
650 558-7270
Project Comments – Planning Application
Project Address: 772 Walnut Avenue, zoned R-1, APN: 028-141-200
Description: Request for Design Review for a first and second story addition to an
existing two-story house.
From: Carolyn Critz
Stormwater
Please address the following comments at this time; provide a written response and revised
plans with your resubmittal:
Project does not create or replace >2,500 square feet of impervious surface or use architectural
copper. Nothing further needed at this time.
The following comments do not need to be addressed now, but you should be aware of them as
they will need to be addressed at time of building permit submittal.
1. Any construction project in the City, regardless of size, shall comply with the city’s stormwater
NPDES permit to prevent construction activity stormwater pollution. Project proponents shall
ensure that all contractors implement appropriate and effective Best Management Practices
(BMPs) during all phases of construction, including demolition. When submitting plans for a
building permit, please include a list of construction BMPs as project notes, preferably on a
separate full size (2’x 3’ or larger) plan sheet. A downloadable electronic file is available at:
http://www.flowstobay.org/Construction under Construction BMP Brochures: Construction
BMP Plan Sheet.
For further assistance regarding stormwater, please contact Carolyn Critz, Environmental Compliance
Manager, at (650) 342 3727, ext. 118, or carolyn.critz@veolia.com
Reviewed By: Carolyn Critz Date: November 7, 2017
(650) 342 3727, ext. 118
Project Comments – Planning Application
Project Address: 772 Walnut Avenue, zoned R-1, APN: 028-141-200
Description: Request for Design Review for a first and second story addition to an
existing two-story house.
From: Bob Disco
Parks Division
Please address the following comments at this time; provide a written response and revised
plans with your resubmittal:
1. No further comments: landscape to remain the same; no existing tree are proposed for
removal.
The following comments do not need to be addressed now, but you should be aware of them as they
will need to be addressed at time of building permit submittal.
Reviewed By: BD Date: 12.19.17
558.7333
Project Comments –
Planning Application
772 Walnut Avenue, R-1
A0.0
COVER
772 WALNUT AVENUE
BURLINGAME CA 94010
GENERAL NOTES
1.THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE CONSTRUCTION MEANS , METHODS , TECHNIQUES , SEQUENCES
AND PROCEDURE AND FOR ALL SAFETY PROGRAMS AND PRECAUTIONS IN CONNECTION WITH THE PROJECT. NEITHER
THE OWNER NOR THE ARCHITECT IS RESPONSIBLE FOR THE CONTRACTOR'S FAILURE TO FOLLOW PROPER SAFETY
PROCEDURES .
2.ALL CODES HAVING JURISDICTION ARE HEREBY MADE A PART OF THIS DOCUMENT AND ARE TO BE STRICTLY
OBSERVED BY THE CONTRACTOR IN THE CONSTRUCTION OF THE PROJECT. IN THE EVENT OF CONFLICT BETWEEN THESE
DOCUMENT AND THE CODE , THE CODE SHALL PREVAIL . ANY CONFLICT OR DISCREPANCY SHALL IMMEDIATELY BE
BROUGHT TO THE ATTENTION OF THE ARCHITECT.
3.ALL WORK , TO BE ACCEPTABLE , MUST BE IN COMPLIANCE WITH THESE DRAWINGS AND SPECIFICATIONS , AND MUST BE
OF A QUALITY EQUAL OR BETTER THAN THE STANDARD OF THE TRADE . FINISHED WORK SHALL BE FIRM , WELL-ANCHORED ,
IN TRUE ALIGNMENT, PLUMB , LEVEL , WITH SMOOTH , CLEAN , UNIFORM APPEARANCE .
4.CONTRACTOR SHALL AT ALL TIMES PROVIDE PROTECTION AGAINST WEATHER , RAIN , WINDSTORMS , OR HEAT SO AS TO
MAINTAIN ALL WORK , MATERIALS , EQUIPMENT AND APPARATUS FREE FROM INJURY OR DAMAGE .
5.CONTRACTOR SHALL VISIT THE SITE OF THE PROJECT, EXAMINE FOR HIMSELF/HERSELF THE NATURE OF THE EXISTING
CONDITIONS AND ALL OTHER CONDITIONS RELEVANT TO THE SATISFACTORY COMPLETION OF THE PROJECT. SUBMISSION
OF A BID FOR CONSTRUCTION SHALL BE CONSIDERED EVIDENCE OF SUCH EXAMINATION BY THE CONTRACTOR .
6.BEFORE ORDERING MATERIAL OR COMMENCING WORK WHICH IS DEPENDENT FOR THE PROPER SIZE AND
INSTALLATION UPON COORDINATION WITH CONDITIONS IN THE BUILDING , THE CONTRACTOR SHALL VERIFY ALL
DIMENSIONS AND SHALL BE RESPONSIBLE FOR THE CORRECTNESS . ANY DISCREPANCIES BETWEEN THE DOCUMENTS
AND THE EXISTING CONDITIONS SHALL BE REFERRED TO THE ARCHITECT FOR ADJUSTMENTS BEFORE ANY WORK BEGINS
OR MATERIALS ARE PURCHASED .
7.MATERIALS , PRODUCTS AND EQUIPMENT SHALL ALL BE NEW, EXCEPT AS SPECIFICALLY NOTED OTHERWISE .
8.CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL DEBRIS IN A LOCATION OF THE PROPERTY APPROVED BY
THE OWNER AND SHALL REMOVE SAME IN A TIMELY MANNER DURING THE COURSE OF WORK .
9.CONTRACTOR SHALL REMOVE FROM SITE ALL EXISTING CONSTRUCTION AND IMPROVEMENTS NECESSARY FOR
COMPLETION OF THE PROJECT, PROTECTION FROM DAMAGE OR INJURY ALL EXISTING TREES , LANDSCAPING AND
IMPROVEMENTS INDICATED BY THE DRAWINGS .
10.EXCAVATE ALL FOOTING AS INDICATED ON THE DRAWING TO REACH SOLID , UNDISTURBED SOIL. BOTTOMS OF
EXCAVATIONS SHALL BE LEVEL , CLEAN AND DRY AND AT THE ELEVATIONS INDICATED ON THE STRUCTURAL DRAWINGS .
11 .PROVIDE FINISH GRADES TO DRAIN AWAY FROM THE FOUNDATIONS ON ALL SIDE OF THE BUILDING .
12. CONTRACTOR TO PRECISELY LOCATE ALL UTILITIES PRIOR TO ANY CONSTRUCTION AND/OR EXCAVATION .
13. SEE STRUCTURAL DRAWINGS FOR REQUIRED SPECIAL INSPECTIONS .
14. AS OF JANUARY 1, 2014, SB 407 (2009) REQUIRES NON-COMPLIANT PLUMBING FIXTURES TO BE REPLACED BY WATER
-CONSERVING PLUMBING FIXTURES WHEN A PROPERTY IS UNDERGOING ALTERATIONS OR IMPROVEMENTS . THIS LAW
APPLIES TO ALL RESIDENTIAL AND COMMERCIAL PROPERTY BUILT PRIOR TO JANUARY 1, 1994. DETAILS CAN BE FOUND AT
HTTP://WWW .LEGINFO .CA.GOV/PUB/09-10/BILL/SEN/SB 0401-0450/SB 407 BILL 20091011 CHAPTERED .HTML .
15. ANY HIDDEN CONDITIONS THAT REQUIRE WORK TO BE PERFORMED BEYOND THE SCOPE OF THE BUILDING PERMIT
ISSUED FOR THESE PLANS MAY REQUIRE FURTHER CITY APPROVALS INCLUDING REVIEW BY THE PLANNING COMMISSION .
THE BUILDING OWNER , PROJECT DESIGNER , AND/OR CONTRACTOR MUST SUBMIT A REVISION TO THE CITY FOR ANY WORK
NOT GRAPHICALLY ILLUSTRATED ON THE JOB COPY OF THE PLANS PRIOR TO PERFORMING THE WORK .
16. ANYONE WHO IS DOING BUSINESS IN THE CITY MUST HAVE A CURRENT CITY OF BURLINGAME BUSINESS LICENSE .
17. THIS PROJECT WILL BE CONSIDERED A NEW BUILDING BECAUSE , ACCORDING TO THE CITY OF BURLINGAME MUNICIPAL
CODE , "WHEN ADDITIONS , ALTERATIONS OR REPAIRS WITHIN ANY TWELVE-MONTH PERIOD EXCEED FIFTY PERCENT OF THE
CURRENT REPLACEMENT VALUE OF AN EXISTING BUILDING OR STRUCTURE , AS DETERMINED BY THE BUILDING OFFICIAL ,
SUCH BUILDING OR STRUCTURE SHALL BE MADE IN ITS ENTIRETY TO CONFORM WITH THE REQUIREMENTS FOR NEW
BUILDINGS OR STRUCTURES ." THIS BUILDING MUST COMPLY WITH THE 2016 CALIFORNIA BUILDING CODE FOR NEW
STURCTURES . BMC 18.07.020.
18. DUE TO THE EXTENSIVE NATURE OF THIS CONSTRUCTION PROJECT THE CERTIFICATE OF OCCUPANCY WILL BE
RESCINDED ONCE CONSTRUCTION BEGINS . A NEW CERTIFICATE OF OCCUPANCY WILL BE ISSUED AFTER THE PROJECT
HAS BEEN FINAL. NO OCCUPANCY OF THE BUILDING IS TO OCCUR UNTIL A NEW CERTIFICATE OF OCCUPANCY HAS BEEN
ISSUED .
19. A COMPLETED SUPPLEMENTAL DEMOLITION PERMIT APPLICATION WILL BE COMPLETED WHEN SUBMITTING PLANS TO
THE BUILDING DIVISION FOR PLAN REVIEW. NOTE: THE DEMOLITION PERMIT WILL NOT BE ISSUED UNTIL A BUILDING PERMIT
IS ISSUED FOR THE PROJECT.
20. A GRADING PERMIT, IF REQUIRED , WILL BE OBTAINED FROM THE DEPARTMENT OF PUBLIC WORKS .
PROJECT SUMMARY
APPLICABLE CODES
2016 California Building Code
2016 California Residential Code
2016 California Mechanical Code
2016 California Plumbing Code
2016 California Electrical Code
2016 California Green Building Code (CalGreen)
2016 California Fire Code (with local amendments)
2015 International Property Maintenance Code
2016 State of California Title 24 Energy Regulations
PROJECT DESCRIPTION
THIS PROJECT INCLUDES A TWO STORY ADDITION TO AN EXISTING
TWO STORY RESIDENCE. THE PROJECT ALSO INVOLVES INTERIOR
REMODELING AND RECONFIGURATION OF THE INTERIOR SPACES
OF THE MAIN HOUSE AS WELL AS INTERIOR REMODELING OF THE
EXISTING ACCESSORY STRUCTURE AND GARAGE.
PROJECT TEAM
ARCHITECT:
JESSICA SIN
JSD ARCHITECTURE + INTERIORS
1328 EBENER STREET
REDWOOD CITY CA 94061
INFO@JESSICASINDESIGNS .COM
650-206-4608
BURLINGAME LICENSE NUMBER: 31999
SURVEYOR:
WADE HAMMOND
WADE HAMMOND PLS
36660 NEWARK BLVD . SUITE C
NEWARK , CA 94560
WADE@WHLANDSURVEYOR .COM
510-579-6112
APN#: 028-141-200
ZONING: R1
CONSTRUCTION TYPE: V-B
OCCUPANCY TYPE: R-3
LOT SIZE: 9,015 SF
SETBACKS:
15'-0" FRONT (FIRST FLOOR)
20'-0" FRONT (SECOND FLOOR)
15'-0" REAR (FIRST FLOOR)
20'-0" REAR (SECOND FLOOR)
4'-0" MIN. SIDE (FIRST FLOOR) FOR ± 50' LOT WIDTH
SECOND FLOOR SIDE SETBACK PER DECLINING
HEIGHT ENVELOPE
MAX. HEIGHT: 30'-0"
EXISTING HEIGHT: ±28'-8 3/4"
PROPOSED HEIGHT: ±28'-8 3/4"
MAX. LOT COVERAGE: 40% = 3,606 SF
MAX. FLOOR AREA: 32% + 1,100 = 3,984.8 SF
EXISTING LOT COVERAGE:
EXISTING HOUSE 1293 SF
EXISTING PORCH 7 SF
EXISTING GARAGE 614 SF
EXISTING ACCESSORY
STRUCTURE 301 SF
EXISTING 2ND STORY BALCONY 38 SF
TOTAL EXISTING LOT COVERAGE: 2,253 SF
PROPOSED LOT COVERAGE:
EXISTING HOUSE 1293 SF
EXISTING GARAGE 614 SF
EXISTING ACCESSORY
STRUCTURE 301 SF
FIRST FLOOR ADDITION 229 SF
REAR COVERED PATIO 354 SF
TOTAL PROPOSED LOT COVERAGE: 2,791 SF
EXISTING FLOOR AREA:
EXISTING FIRST FLOOR: 1,293 SF
EXISTING GARAGE 614 SF
EXISTING ACCESSORY
STRUCTURE 301 SF
EXISTING SECOND FLOOR 1,308 SF
TOTAL EXISTING FLOOR AREA: 3,516 SF
PROPOSED FLOOR AREA:
EXISTING FIRST FLOOR: 1,293 SF
EXISTING GARAGE 614 SF
EXISTING ACCESSORY
STRUCTURE 301 SF
EXISTING SECOND FLOOR 1,308 SF
PROPOSED FIRST FLOOR 202 SF
PROPOSED SECOND FLOOR 204 SF
TOTAL PROPOSED FLOOR AREA: 3,922 SF
VICINITY MAP
DRAWING SHEET INDEX
ARCHITECTURAL:
A0.0 COVER SHEET
A0.1 AREA CALCULATIONS
A1.0 SITE PLAN
A1.1 LANDSCAPE PLAN
A2.0 EXISTING FLOOR PLAN
A2.1 NEW FIRST & SECOND FLOOR PLAN
A3.0 EXISTING ELEVATIONS 1
A3.1 EXISTING ELEVATIONS 2
A3.2 NEW ELEVATIONS 1
A3.3 NEW ELEVATIONS 2
A3.4 SECTION 1
SURVEY:
SU01 SURVEY
GREEN BUILDING MEASURES
TWO COPIES OF THE GREEN BUILDING MANDATORY MEASURES
CHECKLIST WILL BE PROVIDED WITH SUBMITTAL OF THE PLANS
FOR BUILDING CODE PLAN CHECK.
PROPOSED VIEW FROM WALNUT AVENUE
CONSTRUCTION HOURS
AS OF OCTOBER 19, 2016, THE WORKING HOURS HAVE CHANGED
AS FOLLOWS.
CONSTRUCTION HOURS
WEEKDAYS: 8:00 AM - 7:00 PM
SATURDAYS: 9:00AM - 6:00 PM
SUNDAYS AND HOLIDAYS: NO WORK ALLOWED
(SEE CITY OF BURLINGAME MUNICIPAL CODE, SECTION 13.04.100
FOR DETAILS)
CONSTRUCTION HOURS IN THE CITY PUBLIC RIGHT-OF-WAY ARE
LIMITED TO WEEKDAYS AND NON-CITY HOLIDAYS BETWEEN
8:00AM AND 5:00PM.
1
JESSICA SIN
C-35445
REN 5/31/19772 WALNUT AVENUEBURLINGAME, CA 94010 APN# 028-141-200HOME OWNERS: VIVEK AND POOJA SHAHOCT 25 , 2017 DESIGN REVIEW SUBMITTAL
DEC 8, 2017 DESIGN REVIEW RESPONSE1
JAN 8, 2018 DESIGN REVIEW RESPONSE2
A3.0
(EXISTING) ELEVATIONS 1
12
±6
(E) ROOF SLOPE
TO BE CONFIRMED
BY CONTRACTOR
53.3 T.O. FINISH FLOOR
51.5
53.2
49.2'
SOUTH ELEVATION (FRONT) 1 SCALE: 1/4" = 1'-0"
0'2'4'8'±8'-9"1ST FLOOR±8'-0"2ND FLOOR±1'-3"50.2 T.O. AVG. T.O.CURB ±28'-0"PROPERTY LINE@ LINE A-A(SEE SITE PLAN)SIDE SETBACK@ LINE A-A(SEE SITE PLAN)PROPERTY LINE@ LINE A-A(SEE SITE PLAN)SIDE SETBACK@ LINE A-A(SEE SITE PLAN)50.5 AVG. ORIGINAL (E) GRADE 12'-0"7'-6"DECLINING HEIGHT
ENVELOPE
45°3'-1 1/4"(E) BRICK CHIMNEY
TO BE DEMO
(E) HORIZONTAL
WOOD SIDING
(E) WOOD PORCH AND
COLUMNS TO BE DEMO
(E) HORIZONTAL
WOOD SIDING
(E) WOOD
ROOF BARGE
(E) WOOD WINDOWS AND TRIM ,
THROUGHOUT THE HOUSE , TYP.
(E) WOOD ROOF BARGE
(E) WOOD DOOR
TO BE REPLACED
AND RELOCATED
(E) WOOD GARAGE DOOR AND TRIM
TO BE REPLACED
(E) COMPOSITION GABLE ROOF
TO REMAIN , TYP.
(E) ±6:12 COMPOSITION
GABLE ROOF
TO BE DEMO
(E) WOOD ROOF
BARGE
(E) WOOD VENT / TRIM
(E) WOOD
ROOF FASCIA
(E) ±2:12 ROOF AT GARAGE OVER
INTERIOR STAIR TO HOUSE
(E) ±1.5:12 ROOF SLOPE
TO BE CONFIRMED
BY CONTRACTOR
(E) ALUMINUN GUTTER
THROUGHOUT THE HOUSE
(E) BRICK STAIRS AND
LANDINGS TO BE REMOVED
(E) METAL
RAILING TO
BE REMOVED
(E) WOOD SHUTTERS
IN ALL FACADE WINDOWS
EAST ELEVATION 2 SCALE: 1/4" = 1'-0"
0'2'4'8'
53.3 T.O. FINISH FLOOR ±8'-9"1ST FLOOR±8'-0"2ND FLOOR±1'-3"50.2 T.O. AVG. T.O.CURB 3'-1 1/4"±28'-0"±25'-0 3/4"(E) HORIZONTAL
WOOD SIDING
(E) WOOD DECK RAILING
TO BE DEMO
(E) WOOD DECK
TO BE DEMO
(E) ±6:12 COMPOSITION
GABLE ROOF
TO BE DEMO
(E) WOOD PORCH
COLUMN TO BE DEMO
(E) BRICK STAIRS AND
LANDING TO BE DEMO
(E) HORIZONTAL
WOOD SIDING
(E) WOOD WINDOWS AND TRIM
THROUGHOUT HOUSE , TYP.
(E) VERTICAL
WOOD SIDING (E) GLASS SLIDING DOOR /
WOOD TRIM , TYP.
(E) ±1.5:12 COMPOSITION
GABLE ROOF TO REMAIN , TYP.
SLOPE TO BE CONFIRMED
BY CONTRACTOR
(E) VERTICAL
WOOD SIDING
(E) BRICK VENEER (E) BRICK VENEER
(E) BRICK VENEER
(E) WOOD DOOR
TO BE REMOVED
(E) WOOD ROOF FASCIA
(E) WOOD ROOF FASCIA
(E) ±6:12 COMPOSITION ROOF
TO REMAIN , TYP.
SLOPE TO BE CONFIRMED
BY CONTRACTOR
(E) ±6:12 COMPOSITION ROOF
TO REMAIN , TYP.
SLOPE TO BE CONFIRMED
BY CONTRACTOR
(E) ALUMINUN GUTTER
THROUGHOUT THE HOUSE
(E) ±1’9” X 2’11” SKYLIGHT
TO REMAIN
1
1
1
2
2
JESSICA SIN
C-35445
REN 5/31/19772 WALNUT AVENUEBURLINGAME, CA 94010 APN# 028-141-200HOME OWNERS: VIVEK AND POOJA SHAHOCT 25 , 2017 DESIGN REVIEW SUBMITTAL
DEC 8, 2017 DESIGN REVIEW RESPONSE1
JAN 8, 2018 DESIGN REVIEW RESPONSE2
A3.1
(EXISTING) ELEVATIONS 2
WEST ELEVATION2SCALE: 1/4" = 1'-0"
0'2'4'8'
53.3 T.O. FINISH FLOOR±8'-9"1ST FLOOR±8'-0"2ND FLOOR±1'-3"50.2 T.O. AVG. T.O.CURB 3'-1 1/4"±28'-0"(E) BRICK FIREPLACE AND CHIMNEY
TO BE DEMO
(E) ±2:12 SHED ROOF AT
GARAGE OVER
INTERIOR STAIR TO HOUSE
SLOPE TO BE CONFIRMED
BY CONTRACTOR
(E) ±6:12 COMPOSITION
GABLE ROOF TO BE DEMO
(E) WOOD WINDOWS AND TRIM ,
THROUGHOUT THE HOUSE ,TYP.
(E) WOOD ROOF FASCIA
(E) WOOD ROOF FASCIA
(E) HORIZONTAL
WOOD SIDING
(E) HORIZONTAL
WOOD SIDING
(E) ±1.5:12 COMPOSITION
SHED ROOF TO REMAIN , TYP.
SLOPE TO BE CONFIRMED
BY CONTRACTOR(E) ±1.5:12 COMPOSITION
GABLE ROOF TO REMAIN , TYP.
SLOPE TO BE CONFIRMED
BY CONTRACTOR (E) WOOD ROOF FASCIA
(E) BRICK TO BE DEMO
(E) WOOD COLUMN
TO BE DEMO
(E) BRICK STEPS
TO BE DEMO
(E) ±6:12 COMPOSITION SHED ROOF
TO REMAIN , TYP.
(E) ±1.5:12 COMPOSITION
SHED ROOF TO REMAIN , TYP.
SLOPE TO BE CONFIRMED
BY CONTRACTOR
(E) ±6:12 COMPOSITION GABLE ROOF
TO REMAIN , TYP.
SLOPE TO BE CONFIRMED
BY CONTRACTOR
(E) ±6:12 COMPOSITION GABLE ROOF
TO REMAIN , TYP.
SLOPE TO BE CONFIRMED
BY CONTRACTOR
(E) ALUMINUN GUTTER
THROUGHOUT THE HOUSE
NORTH ELEVATION (REAR) 1 SCALE: 1/4" = 1'-0"
0'2'4'8'
53.3 T.O. FINISH FLOOR ±8'-9"1ST FLOOR±8'-0"2ND FLOOR±1'-3"50.2 T.O. AVG. T.O.CURB PROPERTY LINE@ LINE B-B(SEE SITE PLAN)SIDE SETBACK@ LINE B-B(SEE SITE PLAN)3'-1 1/4"12'-0"DECLINING HEIGHT
ENVELOPE
45°7'-6"50.5 AVG. ORIGINAL (E) GRADE ±28'-0"50.2 T.O. AVG. T.O.CURB ±8'-5"±8'-5"±25'-0 3/4"(E) ±2:12 ROOF AT GARAGE OVER
INTERIOR STAIR TO HOUSE
SLOPE TO BE CONFIRMED
BY CONTRACTOR
(E) WOOD
BALCONY
(E) WOOD
BALCONY RAILING
(E) VERTICAL
WOOD SIDING
(E) HORIZONTAL
WOOD SIDING(E) WOOD WINDOWS AND TRIM ,
THROUGHOUT THE HOUSE , TYP.
(E) WOOD ROOF BARGE
(E) ±6:12 COMPOSITION GABLE ROOF
TO REMAIN , TYP.
SLOPE TO BE CONFIRMED
BY CONTRACTOR
(E) COMPOSITION GABLE ROOF
(E) WOOD DOOR AND TRIM , TYP.
(E) WOOD ROOF BARGE
(E) WOOD ROOF BARGE (E) ±1.5:12 COMPOSITION
SHED ROOF TO REMAIN , TYP.
SLOPE TO BE CONFIRMED
BY CONTRACTOR
(E) BRICK CHIMNEY
TO BE DEMO
(E) WOOD WINDOWS AND TRIM ,
THROUGHOUT THE HOUSE ,TYP.
(E) GLASS SLIDING DOOR
AND WOOD TRIM
(E) WOOD DECK RAILING
TO BE DEMO
(E) WOOD DECK
TO BE DEMO
(E) WOOD DOOR / TRIM ,TYP.
(E) ±1.5:12 COMPOSITION
GABLE ROOF
SLOPE TO BE CONFIRMED
BY CONTRACTOR
(E) ALUMINUN GUTTER
THROUGHOUT THE HOUSE
(E) WOOD SHUTTERS
1
1
12
2
JESSICA SIN
C-35445
REN 5/31/19772 WALNUT AVENUEBURLINGAME, CA 94010 APN# 028-141-200HOME OWNERS: VIVEK AND POOJA SHAHOCT 25 , 2017 DESIGN REVIEW SUBMITTAL
DEC 8, 2017 DESIGN REVIEW RESPONSE1
JAN 8, 2018 DESIGN REVIEW RESPONSE2
53.3 T.O. FINISH FLOOR
51.5
53.2±8'-9"1ST FLOOR±8'-0"2ND FLOOR±1'-3"SOUTH ELEVATION (FRONT) 1 SCALE: 1/4" = 1'-0"
0'2'4'8'±6'-10 3/4"50.2 T.O. AVG. T.O.CURB ±28'-0"PROPERTY LINE@ LINE A-A(SEE SITE PLAN)SIDE SETBACK@ LINE A-A(SEE SITE PLAN)50.5 AVG. ORIGINAL (E) GRADE 12'-0"7'-6"DECLINING HEIGHT
ENVELOPE
45°PROPERTY LINE@ LINE A-A(SEE SITE PLAN)SIDE SETBACK@ LINE A-A(SEE SITE PLAN)3'-1 1/4"(N) BOARD AND BATTEN
SIDING , TYP.
(N) METAL AND GLASS
GARAGE DOOR
(N) STEEL AND WOOD ENTRY CANOPY
(N) METAL
ATTIC VENT
(N) SOLID WOOD DOOR WITH
METAL FRAME . CLEAR GLASS
SIDELIGHTS WITH METAL
FRAME .
(N)(N)(N)(N)
(N)(N)
(N)
(N)
PAINTED 2X WOOD BARGE
(N) CONCRETE ENTRY PORCH
AND STAIRS
(N) ALUMINUM CLAD WOOD
WINDOWS THROUGHOUT
THE HOUSE , TYP.
(E) WOOD BARGE
(E) WOOD FASCIA
(E) COMPOSITION
±6:12 SHED ROOF TO
REMAIN , SLOPE TO BE
CONFIRMED
BY CONTRACTOR
(N) COMPOSITION
2:12 SHED ROOF
WOOD
BARGE
12
±6
(E) ROOF SLOPE
TO BE CONFIRMED
BY CONTRACTOR
12
±1.5
(E) ROOF SLOPE
TO BE CONFIRMED
BY CONTRACTOR
(N) 2X PLAIN WOOD CASING AT
ALL OPENINGS , TYP.
ALL GUTTERS
TO BE ALUMINUM
EAST ELEVATION 2 SCALE: 1/4" = 1'-0"
0'2'4'8'
53.3 T.O. FINISH FLOOR ±8'-9"1ST FLOOR±8'-0"2ND FLOOR±1'-3"50.2 T.O. AVG. T.O.CURB ±8'-5"3'-1 1/4"±28'-0"±27'-3 3/4"(N) ALUMINUM CLAD WOOD WINDOW
THROUGHOUT HOUSE , TYP.
(E) ±6:12 COMPOSITION ROOF
TO REMAIN , TYP.
SLOPE TO BE CONFIRMED
BY CONTRACTOR
(N) ±6:12 COMPOSITION ROOF
TO MATCH EXISTING
(N) 2X PLAIN WOOD CASING AT
ALL OPENINGS , TYP.
(N) WINDOW AT STAIR .
EXTENDS 4” FROM SIDING .
(N) METAL AND WOOD
ENTRY CANOPY
(N)
(N)
(N)
(N)
(N)(N)(N)(N)
(N)
(N)(N)
(N) STEEL CABLE RAILING
WITH PAINTED WOOD CAP
WOOD DECK SLOPE
MIN. 1/4” PER FOOT
PAINTED 2X WOOD FASCIA
(N) WOOD PLANTERS , TYP.(N) DOWNSPOUTS , TYP.PAINTED WOOD POSTS
(N) BUILT-IN BBQ ON COVERED PATIO
(N) TREE SHOWN DASHED
ALL GUTTERS
TO BE ALUMINUM
PAINTED 2X
WOOD FASCIA
PAINTED 2X
WOOD FASCIA
(N) ALUMINUM CLAD WOOD
WINDOWS / WOOD TRIM
THROUGHOUT THE HOUSE ,
TYP.
(E) ±1.5:12 COMPOSITION
GABLE ROOF TO REMAIN , TYP.
(E) ±1’9” X 2’11” SKYLIGHT
TO REMAIN
A3.2
(NEW) ELEVATIONS 1
STEEL AND WOOD ENTRY CANOPY3
1
1
1
JESSICA SIN
C-35445
REN 5/31/19772 WALNUT AVENUEBURLINGAME, CA 94010 APN# 028-141-200HOME OWNERS: VIVEK AND POOJA SHAHOCT 25 , 2017 DESIGN REVIEW SUBMITTAL
DEC 8, 2017 DESIGN REVIEW RESPONSE1
JAN 8, 2018 DESIGN REVIEW RESPONSE2
NORTH ELEVATION (REAR) 1 SCALE: 1/4" = 1'-0"
0'2'4'8'±8'-5"53.3 T.O. FINISH FLOOR ±8'-9"1ST FLOOR±8'-0"2ND FLOOR±1'-3"50.2 T.O. AVG. T.O.CURB
50.5 AVG. ORIGINAL (E) GRADE PROPERTY LINE@ LINE B-B(SEE SITE PLAN)SIDE SETBACK@ LINE B-B(SEE SITE PLAN)12'-0"DECLINING HEIGHT
ENVELOPE
45.00°7'-6"±1'-8"3'-1 1/4"±28'-0"50.2 T.O. AVG. T.O.CURB ±27'-3 3/4"(N) ALUMINUM CLAD
WOOD SIDING DOORS
(N) ALUMINUM CLAD
WOOD WINDOWS
AND PATIO DOORS , TYP.
(N) METAL
ATTIC VENT
(N)(N)
(N)
(N)
(N)(N)
PAINTED 2X WOOD BARGE
(N) WOOD PLANTERS , TYP.
(N) WOOD STAIRS
(N) ±6:12 COMPOSITION
GABLE ROOF TO MATCH EXISTING , TYP.
SLOPE TO BE CONFIRMED
BY CONTRACTOR
ALL GUTTERS
TO BE ALUMINUM
(E) ±6:12 COMPOSITION
GABLE ROOF TO REMAIN , TYP.
SLOPE TO BE CONFIRMED
BY CONTRACTOR
(E) ±2:12 ROOF AT GARAGE OVER
INTERIOR STAIR TO HOUSE
(E) WOOD ROOF BARGE
(E) ±1.5:12 COMPOSITION
SHED ROOF TO REMAIN , TYP.
(E) ±1.5:12 COMPOSITION
GABLE ROOF
(N) ALUMINUM CLAD WOOD
WINDOWS / WOOD TRIM
THROUGHOUT THE HOUSE ,
TYP.
(N) 2X PLAIN WOOD CASING AT
ALL OPENINGS
(N) WOOD ROOF BARGE
(N) STEEL CABLE RAILING
WITH PAINTED WOOD CAP
WOOD DECK SLOPE
MIN. 1/4” PER FOOT
WEST ELEVATION 2 SCALE: 1/4" = 1'-0"
0'2'4'8'
53.3 T.O. FINISH FLOOR±8'-9"1ST FLOOR±8'-0"2ND FLOOR±1'-3"50.2 T.O. AVG. T.O.CURB 3'-1 1/4"±28'-0"(N) BOARD AND BATTEN .
SIDING , TYP.
(N) ALUMINUM CLAD WOOD WINDOW
THROUGHOUT HOUSE , TYP.
(E) ±6:12 COMPOSITION
GABLE ROOF TO REMAIN , TYP.
SLOPE TO BE CONFIRMED
BY CONTRACTOR
(N) ±6:12 COMPOSITION
GABLE ROOF TO MATCH EXISTING
SLOPE TO BE CONFIRMED
BY CONTRACTOR
(N) 2X PLAIN WOOD CASING AT
ALL OPENINGS
(N)(N)(N)
(N)
(N)(N)
(N)(N)
(N)
(N)
(N) ±2:12 COMPOSITION ROOF EXTENDED FROM (E)
COMPOSITION ROOF AT GARAGE OVER (N) INTERIOR
STAIR TO HOUSE AND MUD ROOM
WOOD FASCIA PAINTED 2X
(E) 6:12 COMPOSITION
SHED ROOF TO REMAIN , TYP.
(E) VERTICAL
WOOD SIDING
(E) ±1.5:12 COMPOSITION
SHED ROOF TO REMAIN , TYP.
(E) ±1.5:12 COMPOSITION
GABLE ROOF TO REMAIN , TYP.
(E) WOOD ROOF BARGE
(E) WOOD ROOF FASCIA
(E) ±1.5:12 COMPOSITION
SHED ROOF TO REMAIN , TYP.
ALL GUTTERS
TO BE ALUMINUM
A3.3
(NEW) ELEVATIONS 2
1
1
1
JESSICA SIN
C-35445
REN 5/31/19772 WALNUT AVENUEBURLINGAME, CA 94010 APN# 028-141-200HOME OWNERS: VIVEK AND POOJA SHAHOCT 25 , 2017 DESIGN REVIEW SUBMITTAL
DEC 8, 2017 DESIGN REVIEW RESPONSE1
JAN 8, 2018 DESIGN REVIEW RESPONSE2
A1.0
SITE PLAN
51 .4
50 .6
49 .2
48 .1
48.1
F
L
48.7
T
C
49.6
T
C
49.6
F
L
50.4
T
C
51.4
T
C
50.8
F
L
52.0
T
C
52.2
B
W
49.5
B
W
PPRIM=50.63SSMHEl=47.26" FL48.0
T
C
48.3
F
L
49.4
T
C
50.3
T
C
49.7
F
L
50.5
F
L
51.0
T
C
51.2
T
C
51.5
B
W
50.9
B
W
50.3
B
W
49.7
B
W
49.0
B
W
47.8
B
W
48 .9
SSCO
WM
50 .08 TREE 50.810 TREE51.251 .5
51 .5
51 .4
50 .2
El=53 .3
FINISH FLOOR
51.5
51.8
5
2
.
0 52.0
51 .9 52.06 4 JAPANESE MAPLE51 .8
52 .8
18 OAK
52.4 52.4El=50 .00
BENCHMARK SET NS
ASSUMED
49.549.649.651 .4
50 .650.9
SSCO
ELEC METER
51.0
51 .26 TREE
49.949.849.750.15
0
.
0
50.0
El=50 .0
GARAGE SLAB 49 .9
49.9FL49.9FL49.7FL49.6FL49.4FL49.3FL49.1FL49.649.749.450.050.049 .0 48.949 .0
49.950 .5
4
9
.8
4
9
.5
49 .020 RDWD
48.7
49.149.248.148.05
1
.
751.951.8
51.951.852.35
2
.
0
51 .7
GATE
51.552.052.252.152.451.7
5
1
.
3
51 .38 6 TREE 51.78 8 PALM51.351.351.
1
51.151.
1
51.051.351.251.151 .3
51.3SSCO50.0
50 .150.249.951 .0
49.949.74
9
.3
4
9
.
1
49.04
8
.
9
4
8
.949.048 .9
49.84
9
.6 50.250.551.050 .614 TREE
50 .78 TREE
50 .48 TREE50.06 PEAR
48.7
48 .5
48 .5
48 .5
48.248.648.748.648.64
9
.0
49 .0
49 .149.048.949.249
.3
49 .2
49 .249.249.249.2
49 .3
49.249.248.948.848.9
48.9
6 RDWD
48 .8
10 RDWD
48 .8
10 RDWD
48 .910 TREE
48 .6 49.449.3
49 .3
49 .6
49.8
50 .1
50 .0
51 .0
50 .0
El=53.1WOOD DECK4
9
.
9
49 .749.649 .4
49 .3
49.1
49.2
El=49 .6
FINISH FLOOR
4
9
.1
36 30 RDWD
47 .5
47 .2
4
8
.9
47.547.046.947.345 .4
47 .2
48 .1
56 .6
RIDG
E
59 .0
RIDG
E 75.2
RIDG
E 78.2RIDGE51.051.451.349.4
2
4
2
4
O
A
K 52.052.048.049.449.2
FIRE HYDRANT 275'
N50°23'46"W
50 .00'
N35°57'46"E
182 .21'
N46°47'00"W
50 .33'
S35°58'23"W
179 .03'
FIRE HYDRANT 225'DrivewayBuilding
2nd Story
Building Line
Building DrivewayTanbarkGravelGravelDirt
Building
House
Bay Window Dirt
Dirt
Dirt
Dirt
Dirt
Dirt
Dirt
Dirt
Dirt
Dirt
Dirt
Dirt
Conc .
Conc .
Dirt
GravelWood
Ret .
Wall
Brick
Brick
Brick
LAWN
Wood
Steps
Conc .
DirtBrick Ret .
Wall
Brick
BBQ
Overhang
Conc . Ret . Wall With
Wood Fence On Top
Conc . Ret . Wall With
Wood Fence On Top
Brick Ret .
Wall
Brick Ret .
Wall
Brick Ret.
Wall Brick Ret.
Wall
Brick Planter
Brick Planter
(Below)
Brick PlanterBrick Planter
Brick Planter
Conc.Dirt
Dirt
(Below)
Conc . Ret . Wall With
Wood Fence On Top
Overhang
Brick Ret .
Wall
2nd Story
Building Line
Conc .
Curb
Conc .
Curb
Fire Place
Conc. SidewalkConc. SidewalkConc. SidewalkDirtConc. Curb/GutterConc. Curb/GutterConc. Curb/GutterConc. Curb/GutterDirtBrick Wall With
Fence On Top
6" SS SLOPE=-5.8%6" SS SLOPE=-0.5%Brick BorderTyp.11.4'5.8'16.0'24.8'67 .1'
0 .8'
0 .9'
3 .1'12.5'19.9'
19.7'47484
9 5049
4949495051
4950
50
5
1
5
1
49
49 5252
47
48
4
9
5
1
(50' WIDE)WALNUT AVE.51.6
A/C A/C XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXA
A
B
NOTE: THE ROOF EAVES WILL NOT PROJECT
WITHIN TWO FEET OF THE PROPERTY LINE.
2016 CRC TABLE R302.1(1) OR 2016 CBC TABLE 705.2
AVERAGE ORIGINAL EXISTING GRADE
AT WEST SIDE OF PROPERTY IS (48.0+49.2) /2 = 48.6
53.3 T.O FF
PER SURVEY
(N) ONE-STORY OUTDOOR
UNCOVERED PATIO
±6'-4 3/4"±4'-10 1/2"±5'-9 1/4"±11'-4 1/4"(E) ONE-STORY
CANTILEVERED
BAY WINDOW
TO REMAIN (N) ±2’-0” RETAINING WALL
(STARTS AT WALL EDGE)
±19'-8 1/4"
(E) HOUSE OUTLINE
SHOWN DASHED
NOTE: PLEASE REFER TO SURVEY ON
SHEET A-0.1 IN DRAWING SET
FOR DETAILED SITE INFO.
(E) FIREPLACE
AND CHIMNEY
TO BE REMOVED ±12'-6 1/4"(E) 10’X20’
COVERED PARKING SPACE
TO REMAIN SHOWN DASHED
(E) CRAWL SPACE ACCESS
TO REMAIN
(E) 9’X20’
OPEN PARKING SPACE
TO REMAIN SHOWN DASHED
(N) TWO-STORY ADDITION
SHOWN HATCHED
(E) GAS METER
TO REMAIN
(N) 200 AMP ELECTRICAL METER IN
(E) LOCATION
B
PROPOSED SITE PLAN
SCALE: 1/8" = 1'-0"1
0 2 4 6 FT
(N) CONCRETE LANDSCAPE
STEPS AND STAIRS
PROPERTY LINE4'-0" SIDESETBACK20'-0"
FRONT SETBACK
PROPERTY LINEPROPERTY LINE
PROPERTY LINE4'-0" SIDESETBACK20'-0"
REAR SETBACK
(E) CONCRETE DRIVEWAY
AND CURB CUT TO REMAIN
(N) GRAVEL
(E) BRICK PAVING TO REMAIN
(E) ROOF SLOPE , DRAINAGE DIRECTION
AND MATERIAL TO BE CONFIRMED WITH
CONTRACTOR ON SITE
(E) ROOF SLOPE , DRAINAGE DIRECTION
AND MATERIAL TO BE CONFIRMED WITH
CONTRACTOR ON SITE
(E) ROOF SLOPE , DRAINAGE DIRECTION
AND MATERIAL TO BE CONFIRMED WITH
CONTRACTOR ON SITE
(E) ROOF SLOPE , DRAINAGE DIRECTION
AND MATERIAL TO BE CONFIRMED WITH
CONTRACTOR ON SITE
±6:12
±6:12
±6:12
(E)DS
(E)DS
(N)DS
(E)DS(E)DS
±1.5:12
±2:12
±1.5:12
±1.5:12
±1.5:12
±6:12
182'-2 1/2"
179'-0 1/4"50'-0"50'-4"(E) ± 2’-0” HIGH CONCRETE RETAINING WALL
WITH ± 6’-0” WOOD FENCE ABOVE WITH
±1’-0” LATTICE AT TOP
(E) ± 6’-0” FENCE WITH
±1’-0” LATTICE ABOVE
(E) ± 6’-0” FENCE WITH ±1’-0” LATTICE
ABOVE
CONC . RETAINING WALL HEIGHT ± 2’-0”
± 2’-0“ BRICK RETAINING WALL
TO BE REMOVED
PROPOSED SECOND STORY
REAR SETBACK
NOTE:
THE PROPOSED HOUSE HAS EXISTING
NON CONFORMING SETBACK ON
THE WEST SIDE OF THE PROPERTY.11" (E) SIDE SETBACK3'-1"(N)DS(N)DS
(N)DS
(N)DS
(E) 1’9” X 2’11” SKYLIGHT
TO REMAIN
AVERAGE ORIGINAL EXISTING GRADE
AT EAST SIDE OF PROPERTY IS (49.4+51.6) /2 = 50.5
(E) SEWER CLEANOUT
(E) SEWER CLEANOUT
(E) WATER
METER
SSCO
SSCO
(E) ±1’-0” WOOD
RETAINING WALL
(E) ±4’-0” LATTICE FENCE
±100'-5"
(E) CONCRETE DRIVEWAY
AND CURB CUT TO REMAIN
NOTE: LANSCAPE WILL REMAIN AS IS IN AREAS UNAFFECTED
BY THE BUILDING ADDITIONS OR ALTERATIONS.
ALL ROOF PROJECTIONS WHICH PROJECT BEYOND
THE POINT WHERE FIRE-RESISTIVE CONSTRUCTION
WOULD BE REQUIRED WILL BE CONSTRUCTED OF
ONE-HOUR FIRE RESISTANCE-RATED CONSTRUCTION
PER 2016 CRC R302.1(1) OR 2016 CBC 705.2.
(E) BOUNDARY FENCE
(E) BOUNDARY
FENCE ENDS
HERE PER
SURVEY
(E) BOUNDARY FENCE
(E) BOUNDARY FENCE
(E) BOUNDARY FENCE
(E) BOUNDARY FENCE
(E) BOUNDARY FENCE
STARTS HERE
(E) BOUNDARY FENCE ENDS
HERE PER SURVEY
±105'-2 1/4"
EXISTING SECOND STORY
REAR SETBACK
EXISTING FIRST STORY
REAR SETBACK TO REMAIN AS IS
(E) BOUNDARY FENCE
(E) BOUNDARY FENCE
STARTS HERE
12
JESSICA SIN
C-35445
REN 5/31/19772 WALNUT AVENUEBURLINGAME, CA 94010 APN# 028-141-200HOME OWNERS: VIVEK AND POOJA SHAHOCT 25 , 2017 DESIGN REVIEW SUBMITTAL
DEC 8, 2017 DESIGN REVIEW RESPONSE1
JAN 8, 2018 DESIGN REVIEW RESPONSE2
A1.1
LANDSCAPE PLAN
51 .4
50 .6
49 .2
48 .1
48.1
F
L
48.7
T
C
49.6
T
C
49.6
F
L
50.4
T
C
51.4
T
C
50.8
F
L
52.0
T
C
52.2
B
W
49.5
B
W
PPRIM=50.63SSMHEl=47.26" FL48.0
T
C
48.3
F
L
49.4
T
C
50.3
T
C
49.7
F
L
50.5
F
L
51.0
T
C
51.2
T
C
51.5
B
W
50.9
B
W
50.3
B
W
49.7
B
W
49.0
B
W
47.8
B
W
48 .9
SSCO
WM
50 .08 TREE 50.810 TREE51.251 .5
51 .5
51 .4
50 .2
El=53 .3
FINISH FLOOR
51.5
51.8
5
2
.
0 52.0
51 .9 52.06 4 JAPANESE MAPLE51 .8
52 .8
18 OAK
52.4 52.4El=50 .00
BENCHMARK SET NS
ASSUMED
49.549.649.651 .4
50 .650.9
SSCO
ELEC METER
51.0
51 .26 TREE
49.949.849.750.15
0
.
0
50.0
El=50 .0
GARAGE SLAB 49 .9
49.9FL49.9FL49.7FL49.6FL49.4FL49.3FL49.1FL49.649.749.450.050.049 .0 48.949 .0
49.950 .5
4
9
.8
4
9
.5
49 .020 RDWD
48.7
49.149.248.148.05
1
.
751.951.8
51.951.852.35
2
.
0
51 .7
GATE
51.552.052.252.152.451.7
5
1
.
3
51 .38 6 TREE 51.78 8 PALM51.351.351.
1
51.151.
1
51.051.351.251.151 .3
51.3SSCO50.0
50 .150.249.951 .0
49.949.74
9
.3
4
9
.
1
49.04
8
.
9
4
8
.949.048 .9
49.84
9
.6 50.250.551.050 .614 TREE
50 .78 TREE
50 .48 TREE50.06 PEAR
48.7
48 .5
48 .5
48 .5
48.248.648.748.648.64
9
.0
49 .0
49 .149.048.949.249
.3
49 .2
49 .249.249.249.2
49 .3
49.249.248.948.848.9
48.9
6 RDWD
48 .8
10 RDWD
48 .8
10 RDWD
48 .910 TREE
48 .6 49.449.3
49 .3
49 .6
49.8
50 .1
50 .0
51 .0
50 .0
El=53.1WOOD DECK4
9
.
9
49 .749.649 .4
49 .3
49.1
49.2
El=49 .6
FINISH FLOOR
4
9
.1
36 30 RDWD
47 .5
47 .2
4
8
.9
47.547.046.947.345 .4
47 .2
48 .1
56 .6
RIDG
E
59 .0
RIDG
E 75.2
RIDG
E 78.2RIDGE51.051.451.349.4
2
4
2
4
O
A
K 52.052.048.049.449.2
FIRE HYDRANT 275'
N50°23'46"W
50 .00'
N35°57'46"E
182 .21'
N46°47'00"W
50 .33'
S35°58'23"W
179 .03'
FIRE HYDRANT 225'DrivewayBuilding
2nd Story
Building Line
Building DrivewayTanbarkGravelGravelDirt
Building
House
Bay Window Dirt
Dirt
Dirt
Dirt
Dirt
Dirt
Dirt
Dirt
Dirt
Dirt
Dirt
Dirt
Conc .
Conc .
Dirt
GravelWood
Ret .
Wall
Brick
Brick
Brick
LAWN
Wood
Steps
Conc .
DirtBrick Ret .
Wall
Brick
BBQ
Overhang
Conc . Ret . Wall With
Wood Fence On Top
Conc . Ret . Wall With
Wood Fence On Top
Brick Ret .
Wall
Brick Ret .
Wall
Brick Ret.
Wall Brick Ret.
Wall
Brick Planter
Brick Planter
(Below)
Brick PlanterBrick Planter
Brick Planter
Conc.Dirt
Dirt
(Below)
Conc . Ret . Wall With
Wood Fence On Top
Overhang
Brick Ret .
Wall
2nd Story
Building Line
Conc .
Curb
Conc .
Curb
Fire Place
Conc. SidewalkConc. SidewalkConc. SidewalkDirtConc. Curb/GutterConc. Curb/GutterConc. Curb/GutterConc. Curb/GutterDirtBrick Wall With
Fence On Top
6" SS SLOPE=-5.8%6" SS SLOPE=-0.5%Brick BorderTyp.11.4'5.8'16.0'24.8'67 .1'
0 .8'
0 .9'
3 .1'12.5'19.9'
19.7'47484
9 5049
4949495051
4950
50
5
1
5
1
49
49 5252
47
48
4
9
5
1
(50' WIDE)WALNUT AVE.51.6
A/C A/C
A
AVERAGE ORIGINAL EXISTING GRADE
AT EAST SIDE OF PROPERTY IS (49.4+51.6) /2 = 50.5
AVERAGE ORIGINAL EXISTING GRADE
AT WEST SIDE OF PROPERTY IS (48.0+49.2) /2 = 48.6
53.3 T.O FF
PER SURVEY
(E) ±6” - 10” REDWOOD TREES
TO REMAIN
(N) OUTDOOR PATIO
(E) ± 8” GINGKO TREE
TO REMAIN
(E) ± 8” PALM TREE
TO REMAIN
(E) ± 18” OAK TREE
TO REMAIN
±67'-0 1/4"
(E) ±8” - 14” IDAHO LOCUST
TREES TO REMAIN
(E) ±10” VICTORIAN BOX
TREE TO REMAIN ±11'-4 1/4"50.3 T.O. CURB
PER SURVEY
(N) RETAINING WALL
(STARTS AT WALL EDGE)
(E) HOUSE OUTLINE
SHOWN DASHED
NOTE: PLEASE REFER TO SURVEY ON
SHEET A-0.1 IN DRAWING SET
FOR DETAILED SITE INFO.
(E) 6” MAPLE TREE
TO BE REMOVED
(E) GAS METER
TO REMAIN
(N) 200 AMP ELECTRICAL METER IN
(E) LOCATION
PROPOSED LANDSCAPE PLAN
SCALE: 1/8" = 1'-0"1
0 2 4 6 FT
(N) CONCRETE LANDSCAPE
STEPS AND STAIRS
PROPERTY LINE4'-0" SIDESETBACK20'-0"
FRONT SETBACK
PROPERTY LINEPROPERTY LINE
PROPERTY LINE4'-0" SIDESETBACK20'-0"
REAR SETBACK
(E) CONCRETE DRIVEWAY
AND CURB CUT TO REMAIN
(N) GRAVEL
(E) GRASS TO REMAIN
(E) BRICK PAVING TO REMAIN
(E) LAWN
TO REMAIN
(N) FLOWERING PEAR “RED
SPIRE” TREE NEAR STAIR
WINDOW. 24” BOX MIN.
±6:12
±6:12
±6:12
DS
DS
DS
DSDSDS
±1.5:12
±2:12
±1.5:12
±1.5:12
±1.5:12
±6:12
50 .08 TREE 50.810 TREE52.06 4 JAPANESE MAPLE52 .8
18 OAK
51 .26 TREE
49 .020 RDWD
51 .38 6 TREE 51.78 8 PALM50 .614 TREE
50 .78 TREE
50 .48 TREE
48.9
6 RDWD
48 .8
10 RDWD
48 .8
10 RDWD
48 .910 TREE
36 30 RDWD
2
4
2
4
O
A
K TanbarkGravelGravelDirt
Dirt
Dirt
Dirt
Dirt
Dirt
Dirt
Dirt
Dirt
Dirt
Dirt
Dirt
Conc .
Conc .
Dirt
GravelBrick
Brick
LAWN
Brick Ret .
Wall
Brick
BBQ
Brick Ret .
Wall
Brick Planter
Brick Planter
Dirt
Conc .
Curb
Conc .
Curb Conc. Curb/Gutter(N) WOOD PLANTERS
(E) CONCRETE DRIVEWAY TO REMAIN
Brick
Brick
Dirt
Dirt
Brick
Brick
Dirt Brick
(E) GRASS TO REMAIN
Brick
(E) ±2’-0” RETAINING WALL
TO BE REMOVED
±7'-1"±12'-6 1/4"±7'-3 1/2"
±10'-7"
±23'-10 1/4"
(E) ±5-0” HEDGE
(E) ±36” REDWOOD TREE
(E) ±20” REDWOOD TREE
NOTE: TREE DRIP LINES ARE
APPROXIMATE AND TREE SPECIES ARE
IDENTIFIED WITH BEST EFFORTS. BOTH
ARE TO BE CONFIRMED BY AN ARBORIST
OR DENDROLOGIST.
(E) ±24” OAK TREE
±7'-2 1/2"±6'-10"±8'-0"±4'-6"±10'-0"(E) CONCRETE DRIVEWAY
AND CURB CUT TO REMAIN
±13'-8"
NOTE: LANSCAPE WILL REMAIN AS IS IN AREAS UNAFFECTED
BY THE BUILDING ADDITIONS OR ALTERATIONS.
1
JESSICA SIN
C-35445
REN 5/31/19772 WALNUT AVENUEBURLINGAME, CA 94010 APN# 028-141-200HOME OWNERS: VIVEK AND POOJA SHAHOCT 25 , 2017 DESIGN REVIEW SUBMITTAL
DEC 8, 2017 DESIGN REVIEW RESPONSE1
JAN 8, 2018 DESIGN REVIEW RESPONSE2