Loading...
HomeMy WebLinkAboutAgenda Packet - PC - 2018.04.09Planning Commission City of Burlingame Meeting Agenda BURLINGAME CITY HALL 501 PRIMROSE ROAD BURLINGAME, CA 94010 Council Chambers7:00 PMMonday, April 9, 2018 1. CALL TO ORDER 2. ROLL CALL 3. APPROVAL OF MINUTES Draft February 26, 2018 Planning Commission Meeting Minutes Draft February 26, 2018 Meeting MinutesAttachments: 4. APPROVAL OF AGENDA 5. PUBLIC COMMENTS, NON-AGENDA Members of the public may speak about any item not on the agenda. Members of the public wishing to suggest an item for a future Planning Commission agenda may do so during this public comment period . The Ralph M. Brown Act (the State local agency open meeting law) prohibits the Planning Commission from acting on any matter that is not on the agenda. Speakers are asked to fill out a "request to speak " card located on the table by the door and hand it to staff, although the provision of a name, address or other identifying information is optional. Speakers are limited to three minutes each; the Chair may adjust the time limit in light of the number of anticipated speakers. 6. STUDY ITEMS 7. CONSENT CALENDAR Items on the consent calendar are considered to be routine. They are acted on simultaneously unless separate discussion and /or action is requested by the applicant, a member of the public or a commissioner prior to the time the Commission votes on the motion to adopt. 8. REGULAR ACTION ITEMS Page 1 City of Burlingame Printed on 4/5/2018 April 9, 2018Planning Commission Meeting Agenda 1541 Adrian Road and 960 David Road, zoned RR- Application for Conditional Use Permit for a building materials supply store in an existing commercial building, a Conditional Use Permit and a Parking Variance to provide required parking off -site in the drainage right-of-way. The project is Categorically Exempt from review pursuant to the California Environmental Quality Act (CEQA), per Section 15301 - Existing facilities, Class 1(a) of the CEQA Guidelines. (Floor and Decor c /o CenterPoint Integrated Solutions LLC, applicant; Frank Edwards Co. Inc, property owners; SRA, architect) (126 noticed) Staff contact: Catherine Keylon (CONTINUED FROM 3/26/18 PLANNING COMMISSION MEETING) a. 1540 Adrian Rd and 960 David Rd - Staff Report 1541 Adrian Rd and 960 David Rd - Study Minutes and Response 1541 Adrian Rd and 960 David Rd - Application 1541 Adrian Rd and 960 David Rd - Parking and Trip Gen Study 1541 Adrian Rd and 960 David Rd - Traffic Response 1541 Adrian Rd and 960 David Rd - Staff Comments 1541 Adrian Rd and 960 David Rd - Resolution, Notice and Aerial 1541 Adrian Rd and 960 David Rd - Plans - 03.26.18 Received after - 1541 Adrian Rd 3.23.18- K. Manning Received after - 1541 Adrian Rd - 960 David Rd -4.5.18 Attachments: 2208 Summit Drive, zoned R-1 - Application for Hillside Area Construction Permit and Design Review for a new, two -story single family dwelling and Special Permits for height, an attached garage, and basement. This project is categorically exempt from the California Environmental Quality Act (CEQA) pursuant to CEQA Guidelines Section 15303 (a).(Warren Donald, property owner and applicant; Kevin O'Brien, architect) (24 noticed) Staff Contact: Erika Lewit b. 2208 Summit Dr - Staff Report 2208 Summit Dr - Attachments 2208 Summit Dr - Plans - 04.09.18 Attachments: 815 Maple Avenue, zoned R -1 - Application for Design Review and Special Permit for declining height envelope for a first and second floor addition to an existing single family dwelling. This project is categorically exempt from the California Environmental Quality Act (CEQA) pursuant to CEQA Guidelines Section 15303 (e)(2). (Michael Cafferkey, applicant and designer; Michael and Margaret Cafferkey, property owners) (90 noticed) Staff Contact: 'Amelia Kolokihakaufisi (THIS PROJECT IS BEING CONTINUED TO THE APRIL 23, 2018 PLANNING COMMISSION MEETING.) c. Page 2 City of Burlingame Printed on 4/5/2018 April 9, 2018Planning Commission Meeting Agenda Proposed Acquisition of Property Located at 858-860 Hinckley Road by the San Mateo Union High School District (SMUHSD) for Construction of a New Continuation High School/Alternative High School. (SMUHSD, applicant; Hinckley Properties LLC, property owner) (48 noticed) Staff Contact: William Meeker d. Staff Report SMUHSD Notice of Intent to Acquire Property Public Hearing Notice Inner Bayshore (IB) Zoning Regulations Attachments: 9. DESIGN REVIEW STUDY 1432 Vancouver Avenue, zoned R -1 - Application for Design Review and Special Permit for Declining Height Envelope along the left side for a second story addition. (Geurse Conceptual Design, Jesse Geurse, applicant and designer; Kareem Fahmy, property owner) (124 noticed) Staff contact: Catherine Keylon (CONTINUED FROM 3/26/18 PLANNING COMMISSION MEETING) a. 1432 Vancouver Ave - Staff Report and Attachments 1432 Vancouver Ave - Plans - 03.26.18 Attachments: 1316 Laguna Avenue, zoned R-1- Application for Design Review for a second story addition and a new detached garage (Xie Guan , Xie Associate, applicant and architect; Carolyn Bao, property owner) (134 noticed) Staff contact: Catherine Keylon (CONTINUED FROM 3/26/18 PLANNING COMMISSION MEETING) b. 1316 Laguna Ave - Staff Report and Attachments 1316 Laguna Ave - Plans - 03.26.18 Attachments: 834 Crossway Road, zoned R-1 - Application for Design Review for a new, two -story single family dwelling and detached garage. (John Nguyen, Dulon, Inc ., applicant and designer; Diane Mcglown, property owner) (114 noticed) Staff contact: 'Amelia Kolokihakaufisi (CONTINUED FROM 3/26/18 PLANNING COMMISSION MEETING) c. 834 Crossway Rd - Staff Report & Attachments 834 Crossway Rd - Plans - 03.26.18 Attachments: 401 Occidental Avenue, zoned R-1 - Application for Design Review for a first floor addition to an existing single family dwelling and Special Permit for a new attached two-car garage (Robert Boles, Beausoleil Architects, applicant and architect; Jeremy and Margret Werner TR, property owners) (71 noticed) Staff Contact: Ruben Hurin (CONTINUED FROM 3/26/18 PLANNING COMMISSION MEETING) d. 401 Occidental Ave - Staff Report 401 Occidental Ave - Attachments 401 Occidental Ave - Historic Resource Evaluation 401 Occidental Ave - Plans - 03.26.18 Attachments: Page 3 City of Burlingame Printed on 4/5/2018 April 9, 2018Planning Commission Meeting Agenda 118 Loma Vista Drive, zoned R -1 - Application for Design Review for a new, two -story single family dwelling and detached garage. (James Chu, Chu Design Associates, applicant and designer; Kevin O'Sullivan, property owner) (58 noticed) Staff contact: Sonal Aggarwal (CONTINUED FROM 3/26/18 PLANNING COMMISSION MEETING) e. 118 Loma Vista Drive - Staff Report 118 Loma Vista Drive - Attachments 118 Loma Vista Drive - Plans - 3.26.18 Attachments: 1010 Cabrillo Avenue, zoned R -1 - Application for Design Review for a new two -story house and a Conditional Use Permit for a detached new garage with a half bath (Randy Grange, TRG Architects, applicant and architect; Jessica Casey, property owner) (95 noticed) Staff contact: Erika Lewit f. 1010 Cabrillo Ave - Staff Report 1010 Cabrillo Ave -Attachments 1010 Cabrillo Ave - Plans - 04.09.18 Attachments: 841 Rollins Road, zoned R-3 - Application for Design Review for a second story addition and Special Permits for Declining Height Envelope and for an attached garage (Joe Ouyang, designer; Kevin Peng, applicant; Kevin Peng and Xiaoming Huang, property owners) (125 noticed) Staff contact: Erika Lewit g. 841 Rollins Rd - Staff Report 841 Rollins Rd - Attachments 841 Rollins Rd - plans - 04.09.18 Attachments: 10. COMMISSIONER’S REPORTS 11. DIRECTOR REPORTS - Commission Communications - City Council regular meeting April 2, 2018 305 Burlingame Avenue - FYI for review of revisions requested by the Planning Commission for a previously approved Design Review project. (CONTINUED FROM 3/26/18 PLANNING COMMISSION MEETING) a. 305 Burlingame Ave - fyiAttachments: 12. ADJOURNMENT Note: An action by the Planning Commission is appealable to the City Council within 10 days of the Planning Commission's action on April 9, 2018. If the Planning Commission's action has not been appealed or called up for review by the Council by 5:00 p.m. on April 19, 2018, the action becomes final. In order to be effective, appeals must be in writing to the City Clerk and must be accompanied by an appeal fee of $533, which includes noticing costs. Page 4 City of Burlingame Printed on 4/5/2018 April 9, 2018Planning Commission Meeting Agenda Any writings or documents provided to a majority of the Planning Commission regarding any item on this agenda will be made available for public inspection during normal business hours at the Community Development/Planning counter, City Hall, 501 Primrose Road, Burlingame, California. Page 5 City of Burlingame Printed on 4/5/2018 BURLINGAME CITY HALL 501 PRIMROSE ROAD BURLINGAME, CA 94010 City of Burlingame Meeting Minutes Planning Commission 7:00 PM Council ChambersMonday, February 26, 2018 1. CALL TO ORDER The meeting was called to order at 7:01 p.m. Staff in attendance: Planning Manager Kevin Gardiner, Senior Planner Ruben Hurin, and City Attorney Kathleen Kane. 2. ROLL CALL Gum, Gaul, Terrones, Loftis, Kelly, and ComarotoPresent6 - SargentAbsent1 - 3. APPROVAL OF MINUTES a.Draft Minutes - December 11, 2017 December 11, 2017 Minutes (Draft)Attachments: Chair Gum made a motion, seconded by Commissioner Comaroto, to approve the meeting minutes as amended. The motion carried by the following vote: Aye:Gum, Gaul, Terrones, Loftis, Kelly, and Comaroto6 - Absent:Sargent1 - 4. APPROVAL OF AGENDA There were no changes to the agenda. 5. PUBLIC COMMENTS, NON-AGENDA There were no public comments. 6. STUDY ITEMS There were no study items. 7. CONSENT CALENDAR a.833 Mahler Road, #10, zoned IB- Application for a Conditional Use Permit to add the sale of alcoholic beverages to an existing food establishment and to allow weekend hours of operation. The project is Categorically Exempt from review pursuant to the California Environmental Quality Act (CEQA), per Section 15301. (Jorge Sebastiani, applicant; Racola Investments LLC, property owner) (22 noticed) Staff contact: Catherine Keylon Page 1City of Burlingame Printed on 4/5/2018 February 26, 2018Planning Commission Meeting Minutes 833 Mahler Rd #10 - Staff Report 833 Mahler Rd #10 - Application 833 Mahler Rd #10 - Attachments 833 Mahler Rd #10 - Photos and Plan Attachments: Chair Gum made a motion, seconded by Commissioner Loftis, to approve the Consent Item. The motion carried by the following vote: Aye:Gum, Gaul, Terrones, Loftis, Kelly, and Comaroto6 - Absent:Sargent1 - 8. REGULAR ACTION ITEMS a.900 Carolan Avenue, zoned R-1 - Application for side setback, front setback, and lot coverage variances for a single story addition to an existing single family dwelling. This project is Categorically Exempt from review pursuant to the California Environmental Quality Act (CEQA), per Section 15301(e)(1) of the CEQA Guidelines. (Jerry Deal, JD Associates, applicant and designer; Kris and Premilia Reddy Trust, property owner) (49 noticed) Staff Contact: Erika Lewit 900 Carolan Ave - Staff Report & Attachments 900 Carolan Ave - Plans - 02.26.18 Attachments: All Commissioners had visited the project site. There were no ex-parte communications to report. Senior Planner Hurin provided an overview of the staff report. Questions of Staff: >How are the setbacks calculated on wedge -shaped lots? (Hurin: Take the midpoint on each property line and measure across.) Chair Gum opened the public hearing. Jerry Deal, JD Associates, represented the applicant, with property owner Kris Reddy. Commission Questions/Comments: >Although it is an irregularly -shaped lot, the code provides provisions for odd -shaped lots. The calculations are based on the midpoints of the property lines. The argument that the code does not make provisions for irregularly -shaped lots is not accurate. (Deal: It is a much better project single -story. This is the only way there can be a two-car garage.) >There is a metal garage to the left of garage. Consider parking a car there? It's not allowed currently but would be allowed if the garage was expanded. (Deal: Owner is aware the area cannot be used for parking currently but would be if the garage is expanded. However the space will still be nonconforming because it is too short.) >Why the dining room being pushed out on the side, but there is leftover space between Bedroom 1 and Living Room? Maybe there is a way to reconfigure so there is not a lot coverage variance. (Deal: Considered part of the Living Room.) >Would prefer there not be the 4% lot coverage exception. Can't find the exceptional or extraordinary circumstances, concerned about setting a precedent. (Deal: There is no such thing as a precedence when Page 2City of Burlingame Printed on 4/5/2018 February 26, 2018Planning Commission Meeting Minutes granting a variance). Public Comments: There were no public comments. Chair Gum closed the public hearing. Commission Discussion: >Hard time finding justification for the variances. Smaller lots have smaller homes. Existing house is nicely crafted and fits nicely on the lot. Expanding the garage with a single door will have a big face make it look overbuilt. >Can't support variance for being over the lot coverage just because it is a smaller lot. The numbers work well for all the lots regardless of shape. >The intentions are understandable, but has a hard time with the variances. The house already extends close to the extent of the allowable lot coverage. While the justification for the variance has been with the garage, there are also the master bathroom, walk -in closet, and dining room addition. Understands wanting these items, but does not see the logic that exceptional circumstances for small and odd -shaped lots are not addressed in the ordinances. >Understands the garage setback variance but not the lot coverage. >Had been generous on triangular lots in other circumstances. Can make the findings for the variance on the front and side setback variance, but not the lot coverage variance. Seems the additional 200 square feet can be omitted from the lot coverage to comply. >Can't support the lot coverage variance. Would get away from the proportionality that this lot is already struggling with. Vice Chair Gaul made a motion, seconded by Commissioner Loftis, to continue the Action Item. The motion carried by the following vote: Aye:Gum, Gaul, Terrones, Loftis, Kelly, and Comaroto6 - Absent:Sargent1 - b.305 Burlingame Avenue, zoned R -1 - Application for Design Review for a new, two -story single-family dwelling. This project is categorically exempt from the California Environmental Quality Act (CEQA) pursuant to CEQA Guidelines Section 15303 (a). (Danny Meredith, applicant; Helen Cook, property owner; Jaime Rapadas, A R Design Group, designer) (69 noticed) Staff Contact: 'Amelia Kolokihakaufisi 305 Burlingame Ave - Staff Report 305 Burlingame Ave - Attachments 305 Burlingame Ave - Plans - 02.26.18 Attachments: All Commissioners had visited the project site. Commissioner Comaroto had communications with the applicant. Planning Manager Gardiner provided an overview of the staff report. Questions of Staff: There were no questions of staff. Chair Gum opened the public hearing. Page 3City of Burlingame Printed on 4/5/2018 February 26, 2018Planning Commission Meeting Minutes Danny Meredith and Jaime Rapadas represented the applicant. Commission Questions/Comments: >Landscape plan calls for an 8-foot fence along the right side? (Meredith: It is an existing fence.) >There are gravel beds along the driveway side between the driveway and the house. Could this be a landscape bed? (Rapadas: It is gravel, and a drainage solution .)(Meredith: Can be used as runoff or a planter box. Can't allow runoff into the street. Landscaping is somewhat negotiable.) Landscaping will help soften the area along the building wall. >Rear area is shown as all lawn. Will there be planter beds around the edges? (Meredith: Lawn does not go all the way to the edge. Will have planter beds.) >Scale has been nicely redone. >Will there be trim around the front door? (Meredith: Yes,lights and trim.) >Could replicate the tudor detail that is on the garage. Public Comments: Property owner from the house directly west: Concerned with the garage, it is right on the property line . Whomever built our garage is almost on the property line. There is a little less than a foot between their garage and the other garage, and can't paint the side of the garage because there is not enough space . The back of the garage is against the fence as well. Would prefer the garage be moved to the east a bit so there is room to get in between to allow painting. Chair Gum closed the public hearing. Commission Discussion: >Likes the changes that have been made. Previously unclear how the roof worked. >Odd thing with the entrance, moves between tudor and mission. Can come back as an FYI, to bring the entry into line with the detailing of the rest of the house. >Supports landscaping between the driveway and house. >Prudent to move the garage to allow access. >Would be beneficial to have the garage offset to the side to allow for maintenance since the garages are side by side. Back is more flexible, could take the fence down to maintain the back if necessary. >Previously the neighbor to the rear described an accumulation of leaves and debris behind the garage. Chair Gum made a motion, seconded by Commissioner Loftis, to approve with the following condition: >that prior to issuance of a building permit, an FYI application shall be submitted showing 1) trim around the front entry door consistent with the Tudor style to match the rest of the house, 2) Tudor trim detailing on the gable above the front entry similar to what is shown on the detached garage gable, 3) planter beds along the edges of the landscape areas in the front and rear yards, 4) landscaping in the strips between the house and driveway, and 5) the detached garage moved 1-2 feet away from the side property line with consideration to move it away from the rear property line. The motion carried by the following vote: Aye:Gum, Gaul, Terrones, Loftis, Kelly, and Comaroto6 - Absent:Sargent1 - Page 4City of Burlingame Printed on 4/5/2018 February 26, 2018Planning Commission Meeting Minutes 9. DESIGN REVIEW STUDY a.150 Park Road (Parking Lot F), zoned HMU & R-4: Application for Design Review and Density Bonus Incentives for construction of a new 132-unit affordable workforce and senior apartment development (Chris Grant, The Pacific Companies, applicant; City of Burlingame, property owner; Pacific West Architecture, architect) (246 noticed) Staff Contact: Ruben Hurin 150 Park Rd (Parking Lot F) - Staff Report 150 Park Rd (Parking Lot F) - Attachments 150 Park Rd (Parking Lot F) - Plans - 02.26.18 Attachments: All Commissioners had visited the project site. Commissioner Terrones had met with the applicant to get a preview of the project. Commissioner Comaroto also met with the applicant. Planning Manager Gardiner and Senior Planner Hurin provided an overview of the staff report. Questions of Staff: >Land close to the train is precious, wants to encourage growth around transit hubs. Could car ownership be a consideration in residency? Perhaps preference to someone who does not have a car. Chair Gum opened the public hearing. Douglas Gibson, project architect, represented the applicant, with Caleb Roope of Pacific Companies. Commission Questions/Comments: >What is driving the ground floor community room height? That's not atypical if that was retail space . Or is the floor height of level 2 derived from contaminated soil, that it is not possible to go any further down? (Gibson: Yes, the floor height is derived from the height needed for the parking lifts. For seismic there will be steel in the structure, which will allow the community space to be opened up.) >Is the 15 feet driven also by a requirement in the Specific Plan for retail space, but even if the 15 feet weren't required since there would not be retail space, can't push the garage further down without going deeper underground. (Gibson: Needs an extra 2 feet for SUVs. Should be closer to 17 feet to accommodate SUVs.) >Request that resubmittal shows what size cars can be accommodated with the lifts. >Is there a possibility to revisit the colors? The gray on the ground floor looks drab. The rendering does not look vibrant. >Why does garage entry need to be so high in height? It looks like a loading dock. (Gibson: Could bring it down 3 feet.) >Could the entry to the apartments be further highlighted? (Gibson: Yes.) >There are blank spots on the facade, but some have wire mesh with planting. Could that be added to other portions where there are blank areas? (Gibson: Yes, it can be done. The project in Richmond has examples of this.) >Is there a particular manufacturer of the vinyl windows being considered? (Gibson: Typically uses Alside. They can do different profiles. Richmond project has a higher grade and more articulation on the extrusion. From 20 feet away it looks like an aluminum window.) Would like to see a sample or reference. >Paloma Park is an example of a vibrant pocket park, heavily used. Is there a reason why the entrance can be marked as a park? Maybe bollards or lanterns, so it feels more than just coming off the sidewalk . Will also provide a sense of security and enclosure. >Could the play structure have a small enclosure? Just a low fence, or something to give a sense of Page 5City of Burlingame Printed on 4/5/2018 February 26, 2018Planning Commission Meeting Minutes security. (Gibson: Yes, can program this.) >What is the "viewing area" in the park? (Gibson: A place for parents to hang out and watch their kids ). Would encourage benches around the edge of that. >Rear corner has close proximity to the adjacent multifamily property. Could that be followed up? It is the one area where the proximity to the adjacent buildings needs to be revisited and carefully considered . As shown there will be windows against balconies. Would like some relief, further study of that facade. >Podium level just has three trees in planter boxes. Could there be consideration to other things happening on the podium? Perhaps the units could have access to that outdoor area? (Gibson: There is not a code reason that would prevent it.) >Computer room is in the corner, but instead maybe have it viewable to the courtyard. (Gibson: For the State of California there will be a computer workspace, will probably have five or six workstations and printers. If seniors do not have computers in their apartments they can use them here. Also available for tutoring. It is programmed, lockable, and has controlled access times.) Could that work off of the outdoor area? It would make the room more than a windowless space, would be a better amenity. (Gibson: Can look at it.) >Any program for the community room? Could it also operate as an exercise room? (Gibson: Yes, can consider exercise equipment in the room. Has not yet determined what the program will be.) Should be programmed. >Is the proposed material real stucco, not EIFS? (Gibson: Yes, 2-coat based on the energy requirements.) Will want to see color samples. (Gibson: Will have a color board with multiple samples, including the glazing and windows.) >Regarding pedestrian vibrancy on Park Road, would be nice if it looked more open to the public. >Small park on Primrose between Burlingame Avenue and Howard is well used. Has a fence and a gate, and is great for the kinds. Would like some more trees and maybe some grass if possible. A place for pets if they are allowed. >Would like to see more trees on Park Road, and in the park area. Perhaps a water feature or water fountain for the kids and pets - kids up top and pets below. >Concern with the patio area on top, seeing bikes and laundry. Will there be codes and regulations for the apartments? (Gibson: All residents will be required to go through background check and sign lease agreements. Each facility has its various requirements. Can make specific requirements within the limits and statutes of the law.) >Has there been a shadow study? (Gibson: Can provide a shadow study showing the dates and times requested.)(Gardiner: The Downtown Specific Plan provides guidance on the dates and times to be evaluated for a shadow study. Should model both existing conditions as well as with the proposed project so they can be compared.) >Likes the East side with the Park. Would like improvement on the West side. Although tall, the building to the south has less impact with the curved and angular side and the landscaping. Perhaps borrow some ideas from the adjacent building such as cutting the sides to add more open space and landscaping. >Concern with the park not having enough sunlight, will be in shadow most of the time. Perhaps step the building down to allow some light into the park during the bulk of the day. >Architecture in the neighborhood is characterized by the Masonic Temple, and romanesque and mediterranean styles to the south. Consider keeping with the essence of Burlingame traditional styles . (Gibson: Did look at a "Narragansett" shingled style with gray shingles and white trim. It looked really big and didn't look like it would fit in, seemed like an aberration. Can look at the massing and the skin of the structure.) >Eaves on the corners but no eaves in between. (Gibson: Tried to work on a tripartite elevation with a strong base and mid plane. As the structure steps back, loses some of the tripartite feeling at the top of the structure.) >Why is the commercial aspect on the ground floor not being taken advantage of? (Gibson: Lacks synergy of retail uses, nothing to the north or south. Needs spontaneity of people walking by to be viable . Would not want to have a commercial space that would always be for lease if it can't be operated. Would prefer that it be a space the community could use.) How about commercial uses the residents would take advantage of? Lacks pedestrian experience on the Park Road side. Page 6City of Burlingame Printed on 4/5/2018 February 26, 2018Planning Commission Meeting Minutes >There are back of house elements located at front of house, such as electrical and mechanical rooms. If they were moved to the back would that allow enhancement of the pedestrian experience on the front? (Gibson: Yes in theory, but there are considerations with PG&E and Fire such as the length and size of service, electrical transformer feed, PG&E access. Has tried to minimize the exposure in the front and split it.) Creates a blank spot before reaching the entrance coming down Howard. >Back corner is close to the the adjacent residential, would like to see if it could be stepped back. >Neighbor has expressed concern with the shared tree at the edge of the park; perhaps step the building back at that spot or the entire back. Would also lessen shadows on the park. >Not convinced by the architecture. Seems bulky, appears massive. Building next door might not be the right one for comparison. Height and mass may not be consistent with the design guidelines of the Specific Plan. Public Comments: Dennis Gale, 110 Park Road: 110 Park Road has been in place for 44 years. Has concern with the use of the public parking lot. Enthused about the City stepping forward to take a proactive role bringing affordable housing. Was initially concerned with garage access, thought it would be at the southwest corner but it will be at the northwest corner, which will be good. Lot F is not a scenic treasure, hopes this will provide something more scenic. Subsurface conditions with environmental remediation, concern with toxic or hazardous waste being exposed to the air during construction, wants a better understanding of what will be done to protect those living close by. Question about raising the floor plates higher, which will raise the height of the building, and further cut off sunlight since the sun sets to the west. Anna Franco: Shadow design impact has been mentioned. These are two massive projects on a narrow street, the 100 block of Lorton Avenue. Asks to consider impacts of the structures in their current size and design. More front, side and rear setbacks on both projects will alleviate the bulkiness, keep the area pedestrian friendly, and continue to allow light and space for the existing residents. Light studies and shadow impact testing should be required to determine potential impacts. Concern with losing the Monterey cypress tree at 137 Lorton Avenue - will not agree to its removal, encourage the developer to work around the tree and incorporate it into the park as a way to transition the old and the new. David Mendell, 214-216 Lorton Avenue. Lots of construction going on, parking is imperative. Important that the parking structure should be a priority to finish first so there is adequate parking for the construction people, as well as for the clients and workers of the businesses. Marina Franco: Submitted an e -mail previously, has since reviewed the Burlingame Downtown Specific Plan and sees the codification of concerns. Disingenuous to compare to 110 Park Road as complementary because it is the tallest building. There are at least two apartment buildings on Park Road that will face this project which are significantly smaller. There are three apartments on Lorton Avenue that are two or three stories. The Park Road tower has significant setbacks and is on a corner. Downtown Specific Plan mentions land use transitions with care to respect scale and privacy of adjacent properties, stepping back upper stories, reducing mass by compositions of solids and voids, maintain privacy of neighboring structures - all concerns to the three residential buildings along Lorton, forming the back side of the housing portion. The parklet is fantastic, but it is right up against the properties. Lights, shadows, privacy are concerns. Happy to hear there is concern with the tree. Project should not be at the expense of existing residents and neighbors. Heather Sirk: Agent for the owners of the buildings at 125 and 129 Lorton Avenue. Concerns are the same as others. Concern for the the households in the existing apartments. 20 households in the two buildings, 6 will be close enough to borrow a cup of sugar from the neighbor across the way if the building gets built as is. Likes that the city is proactive with the affordable housing, but doesn't want the 20 households in the existing building to lose their light and air. It is disingenuous to show the proposed building next to 110 Park Road; if there was a cross -section showing the side of the proposed building and the buildings back up against it, it would be dwarfed with loss of light and space for those buildings. There are a lot of things Page 7City of Burlingame Printed on 4/5/2018 February 26, 2018Planning Commission Meeting Minutes to like about the proposal, but people have been feeling invisible. Tom Hatfield, 110 Park Road: Views on the screen don't make clear how the new building will sit next to theirs. Worried about the excavation for the underground garage construction affecting the structural integrity of the wall on the boundary and the drainage. The side of the lot along the project has a swimming pool and jacuzzi and recreation area with shuffleboard and gazebo, had initially asked that the side of the building not be a looming wall of apartments overlooking the swimming pool and community area. Will block light, air, and privacy. Would prefer the building step back wedding cake-fashion on that side. Drew Dara-Abrams, 128 Lorton: Supports affordable housing, understands in the financing how the nip and tucks can make the project fall apart. Understands the physical concerns on the street, and that there will need to be compromises to make this kind of affordable housing work. Questions whether the size of the parking garage has been evaluated for use and cost benefit analysis, or if it's just seeking to replace spots. Curious how the spots will be used, given expense of constructing them at $30-40,000 each. Requests the projects included improvements to the sidewalks and crosswalks, also improve the Bayswater/Lorton intersection to make it easier to cross. Requests during construction the contractors realize the site abuts a residential zone, take that into account when setting construction hours. Hopes the project will be seen to completion and trusts it will be done well. Chair Gum closed the public hearing. Commission Discussion: >Unique project to have the City offer the property to get something built. >Enthused to be getting more housing into the downtown area - goal of the Downtown Specific Plan. >Make the project as good as can be. Color and detail, and aspects of charm and delight so it is not just typical, but delightful and loved in the neighborhood because it is a good project. >Cedar tree in the back would provide some great advantage to the park. Will need to do something at the back corner so it survives. >Surface lots in downtown reek of underutilization. >Although it's not strictly a residential neighborhood, there are edges the project backs up to that are residential. Commercial buildings along Howard are likely to evolve over time, and there are other surface parking lots. Needs more attention to the rear of the project, reworking of the facade and massing on that side, needs some relief with the adjacent residential buildings. >Would like to see a bike area in the complex, by the front door, with room for Lime bikes. >Consideration for parking for delivery drop offs. >Excited by the project. In general the project is extremely well articulated - a sophisticated modern building. Does a good job of breaking down the larger mass into an articulated, well -scaled building for a building of this size. It is a transitional site between some smaller buildings moving towards a changing downtown. >Looks forward to seeing sample boards and more information. >Tripartite suggests a strong base, but here it is a base created by a negative as opposed to having a strong base. The apparent base is from the horizontal line at the bottom of the white boxes above; could use some more work. Maybe the trellis treatment from the back of the building should also be on the front, or a material change. >Garage opening undemines the apparent base of the building by lifting up higher than the adjacent floating boxes. >Fitting in has to do with the articulation of the massing, not the style. This architecture does a good job of finding its place in the surrounding area. >There are issues with privacy, challenges with tight boundaries. Relief around the edges will be necessary, maybe some screening. >Ground floor needs the most work. If it fit in well with the pedestrian scale, the upper floors could mesh together better. Needs human scale at the ground level. >Likes that the exterior elements have depth, will add to the feel of the street. Landscaping is Page 8City of Burlingame Printed on 4/5/2018 February 26, 2018Planning Commission Meeting Minutes inadequate, no buffering elements to make it inviting for people walking by. Normally would ask for decreasing units or reworking the building, but would be at odds with the program of more units at an affordable rate. Needs to come up with some ideas to approach in a non -traditional way. Park Road elevation is too bland, no buffering elements to make people want to walk through the area. >Building will be prominent because of its mass and size. Most photographed building in the City is the train station, would like this building to be just as photographed as a representation of Burlingame. Needs to step down the corners or massing to accommodate neighborhood fit. >Likes the style and look of the building. Has a nice rhythym and vocabulary, but details need to work . Other traditional styles would look heavy, and would need to go the distance with detail and refinement to be successful. >Can't see why the block of back of house functions at front can't be pushed back to the parking garage demising wall, then continue the glazing along the front, with a mural or something along the back wall behind the glazing. The item will return as an action item upon completion of the environmental review. b.160 Lorton Avenue (Parking Lot N), zoned R-4: Application for Design Review and Lot Merger for construction of a new five level parking garage (Chris Grant, The Pacific Companies, applicant; City of Burlingame, property owner; Watry Design, Inc ., designer) (246 noticed) Staff Contact: Ruben Hurin 160 Lorton Ave (Parking Lot N) - Staff Report 160 Lorton Ave (Parking Lot N) - Attachments 160 Lorton Ave (Parking Lot N) - Plans - 02.26.18 Attachments: All Commissioners had visited the project site. Commissioners Terrones and Camoroto had met with the applicant. Planning Manager Gardiner and Senior Planner Hurin provided an overview of the staff report. Questions of Staff: There were no questions of staff. Chair Gum opened the public hearing. Caleb Roope represented the applicant. Commission Questions/Comments: >How will it work with the back of the garage built up against the adjacent buildings on Howard Street? Will they have access to the backs of their buildings? (Roope: Many of the buildings are already built to the lot lines, and do not have windows or penetrations on those sides. The intention is that there will not be access between or from those properties to the garage. Otherwise there would be issues with penetrations with the Fire Code. The structure will be built from the inside out to the edge.) >Should overlay the adjacent buildings onto the elevations. >Would like to see a shadow study. (Roope: Yes, it can be done. It's already been done for the residential structure.) Public Comments: Thomas Katy, 128 Lorton, directly adjacent to the structure: Three rentals in the front, cottage in the back. Speaking as a property owner, is also and civil engineer and general contractor. Length of time for Page 9City of Burlingame Printed on 4/5/2018 February 26, 2018Planning Commission Meeting Minutes construction, noise, shadowing, being engulfed and closed off, mass and density directly adjacent. Was not sure whether the property would be sold or leased to Pacific. Wants to know how long the construction will last, and how much noise. With 388 spaces, wants to see how traffic flow will be going in and out. Will lose view and sunlight. Wants to know what the building will look like, will it be an institutional design? Marina Franco: Has property across from Lot N. Concern with enormous structures on small narrow block of Lorton Avenue. Highland is abutted by industrial car shops, would expect that side to remain commercial and not have housing on that side. Suggests putting more mass on the Highland side since commercial will be less impacted than the residential on Lorton. Nick Delis: Resident and landlord. Was involved in Burlingame Avenue streetscape project; same concerns at that time with what was going to happen. Streetscape was the foundation for expanding onto Howard and the whole downtown area. Both of these projects need to go through - through compromise, the community will win. Already beautiful with the streetscape, and now bring in the parking lot, housing . It's a win-win, but all have to compromise. Tenants are in support, parking is needed. Tom Hatfield, 110 Park Road: Concern with the traffic flow with the narrow width of streets, and short blocks. There is not a lot of room for cars to stack up on the streets. There will be a lot more cars. 110 Park is already the largest multifamily building in the neighborhood, but the new building will have three times as many units. Adding the parking garage with 388 spaces will add traffic. Not comparable to anything in Burlingame except the apartments on Carolan Avenue, and California Drive. Commission question to applicant: Can the parking structure be built first? (Roope: It's a challenge . Desire is to build them at the same time. When the financing for the apartments is closed, it provides financing for the parking garage. Although the City is providing land, Pacific is providing resources to the City so the parking garage can be built. Could do the residential first, but not in reverse order. Garage will be built faster since it is less a complex structure. There will be short -term pain from a parking perspective, but at the end there will be 178 new parking spaces. Has concern with the residential building next door to the parking garage, pulled the building back on those sides and pushed it up against the north property line, but knows they are impacted. Trying to reduce the impacts from the construction and from the long-term. David Mendell, 214-16 Lorton: Wants to find some creative ways to have the parking happen first. Perhaps the City can provide a loan from its reserve. Imperative that the parking is done first - hard to retain business when parking is difficult. Needs space for the trucks, find creative ways to make it work to reduce the hardship on businesses. Chair Gum closed the public hearing. Commission Discussion: >Will the land be sold or leased? (Kane: Garage will remain City land and will be an asset owned and controlled by the City. Terms for the housing on Lot F are still being worked out.) >Should look at how it abuts the properties on Howard Avenue. >Parking structure in downtown San Mateo has brought a lot of life to B Street. >Traffic and parking with affordable and senior housing will not be the same as other developments. >Does not think the parking structure facade is right yet. Comment letter mentioned metal fins, concern they need to be maintained. They're just applied things. >Suggests something lighter and simpler and airy, that doesn't try to be something more than it is . Doesn't add a lot of bulk and mass. Landcaping relief to the building walls, and trees along the one side, could be a nice paseo from Lorton to Highland. >Downtown San Mateo garage has some retail space, creates some pedestrian liveliness. Maybe more on the Lorton side, something for pedestrians. >Should be a fusion of utilitarian and environmental themes. Maybe appropriately -sized trees on the Page 10City of Burlingame Printed on 4/5/2018 February 26, 2018Planning Commission Meeting Minutes upper level visible from the street and surrounding buildings. >Looks plain, utilitarian. >Would modifying the aisle widths allow it to be stepped back more, to provide plantings? >Simplify, make it clean and airy. >Would hope there will not need to have as many parking structures in the future. >Soften the sides a bit. >Perspective drawings showing the neighboring buildings, to show the scale. >Wants relief on the sides facing the residences. >Bar has been set too low. Doesn't hang together; building does not have a clear thought on how it should address the street. There are good examples of new parking garages in Mission Bay, Palo Alto. A new one being built in West Sacramento right now. Should provide samples of good-looking garages. >Designed a garage at St. Lukes in San Francisco with a glass box with bike storage on the ground floor. Bikes were on the ground level hanging in the glass box. >Designer needs to take a stand on how the building fits urbanistically into the city. The item will return as an action item upon completion of the environmental review. 10. COMMISSIONER’S REPORTS There were no commissioner's reports. 11. DIRECTOR REPORTS a.1354 Columbus Avenue - FYI for review of revisions requested by the Planning Commission to a previously approved Design Review project. 1354 Columbus Ave - FYI 1354 Columbus Ave - plans - 02.26.18 Attachments: Accepted. 12. ADJOURNMENT Meeting adjourned at 10:03 p.m. Note: An action by the Planning Commission is appealable to the City Council within 10 days of the Planning Commission's action on February 26, 2018. If the Planning Commission's action has not been appealed or called up for review by the Council by 5:00 p.m. on March 8, 2018, the action becomes final. In order to be effective, appeals must be in writing to the City Clerk and must be accompanied by an appeal fee of $533, which includes noticing costs. Any writings or documents provided to a majority of the Planning Commission regarding any item on this agenda will be made available for public inspection during normal business hours at the Community Development/Planning counter, City Hall, 501 Primrose Road, Burlingame, California. Page 11City of Burlingame Printed on 4/5/2018 Parking and Trip Generation Study Floor & Decor Prepared for: Floor & Decor Outlets of America, Inc. Prepared by: Kimley-Horn and Associates, Inc. 12740 Gran Bay Parkway West, Suite 2350 Jacksonville, Florida 32258 FBPE No. CA 00000696 William J. Schilling Jr., P.E. Florida License Number: 53947 Date: Kimley-Horn and Associates, Inc. March 2017 Floor & Decor Parking and Trip Generation Study Page i March 2017 TABLE OF CONTENTS Page Introduction ................................................................................................................................ 1 Data Collection........................................................................................................................... 1 Results of Parking Data Collection ............................................................................................. 2 Results of Trip Generation Data Collection ...............................................................................11 Summary ..................................................................................................................................13 Appendix A: Sample Parking and Trip Generation Data Collection Sheets Appendix B: Parking Data Collection Appendix C: Trip Generation Data Collection LIST OF FIGURES Page Figure 1: Boynton Beach Store Location Map ............................................................................ 3 Figure 2: Wayne Store Location Map ......................................................................................... 4 Figure 3: Potomac Mills Store Location Map .............................................................................. 5 Figure 4: Santa Ana Store Location Map.................................................................................... 6 Figure 5: North Houston Store Location Map ............................................................................. 7 Figure 6: Arlington Heights Store Location Map ......................................................................... 8 Figure 7: Mall of Georgia Store Location Map ............................................................................ 9 LIST OF TABLES Page Table 1: Peak Parking Counts and Rates .................................................................................10 Table 2: Peak Hour Trip Generation Summary.........................................................................12 Table 3: Average Parking and Trip Generation Rates ..............................................................13 Table 4: Highest Parking and Trip Generation Rates ................................................................13 Floor & Decor Parking and Trip Generation Study Page 1 March 2017 Introduction Floor & Decor has retained Kimley-Horn and Associates, Inc. (Kimley-Horn) to determine actual parking and trip generation rates at several of their existing stores around the country. Due to the characteristics of Floor & Decor’s products, the sizes of the stores are very large in comparison to other retail stores, typically ranging between 60,000 and 100,000 square feet. The stores are sized to accommodate the large amount of flooring inventory that is typically stored and displayed for sale within the store. Historically, in order to determine the trip generation and required parking for a proposed Floor & Decor store, municipalities have used parking and trip generation rates that are based on studies for more traditional commercial retail stores. These traditional retail rates tend to overestimate the parking spaces needed and the weekday peak hour trips generated by a Floor & Decor store. This can result in Floor & Decor incurring unnecessary costs associated with constructing under-utilized parking lots for its stores or over-assessment for off-site transportation mitigation or mobility fees. Kimley-Horn has recently conducted parking and trip generation data collection for several existing Floor & Decor stores around the country. From the data collection, actual parking and trip generation rates were determined for the existing stores, based on the gross leasable area of the stores. This report summarizes the data collection and resulting parking and trip generation rates. Data Collection Parking and trip generation data was collected for seven Floor & Decor stores around the country. These seven sites represent the best performing stores in each of their respective markets and were selected for study to collect data at the stores anticipated to have the highest parking and trip generation rates, representing a “worst-case” scenario. The store locations are as follows: 1. 1974 High Ridge Road; Boynton Beach, FL, 33426 2. 77 Willowbrook Boulevard; Wayne, NJ 07470 3. 14041 Worth Avenue; Woodbridge, VA 22192 4. 1801 East Dyer Road; Santa Ana, CA 92705 5. 17211 North Freeway; Houston, TX 77090 6. 600 East Rand Road; Arlington Heights, IL 60004 7. 2918 Buford Drive; Buford, GA 30519 Floor & Decor Parking and Trip Generation Study Page 2 March 2017 Figures 1 through 7 provide aerial location exhibits for each of the seven studied Floor & Decor stores. The store in Woodbridge, Virginia was recently studied by Kimley-Horn in August 2016. The parking and trip generation data obtained for that study was used in this analysis. For the other six stores, Kimley-Horn staff collected weekday parking and trip generation data between Tuesday, January 24, 2017 and Thursday, January 26, 2017. The weekday parking and trip generation data was collected from 7:00 AM to 9:30 AM and from 4:00 PM to 7:00 PM. Also, parking data collection was collected at the six stores on either Saturday, January 21, 2017 or Saturday, January 28, 2017 from 11:00 AM to 2:00 PM. According to Floor & Decor, the stores do not typically experience seasonal variations in patronage levels and sales. Therefore, the data collection is anticipated to represent typical store conditions. In order to conduct the trip generation data collection, a Kimley-Horn staff member stood near the entrance to the Floor & Decor store and observed the parking lot. When a vehicle entered the parking lot and a person or a group of people got out of the vehicle and entered the Floor and Decor store, this was counted as one inbound vehicle trip. When a person or group of people exiting the Floor & Decor store got into a vehicle and exited the parking lot, this was counted as one outbound vehicle trip. This trip generation data collection method was used recognizing that several of the studied Floor & Decor stores are within shopping centers having multiple tenants, and this was the easiest way to isolate those trips to the shopping centers specifically destined to/from the studied Floor & Decor store. Appendix A contains samples of the data collection worksheets used at the six stores in which new data was collected. The parking data collected at each of the seven sites is included in Appendix B, and the trip generation data is included in Appendix C. Results of Parking Data Collection Table 1 presents the results of the parking data collection. As shown in Table 1, the maximum parking rate in spaces per 1,000 square feet of gross leasable area occurred during the Saturday data collection for all seven stores. The Saturday peak parking rates varied from 0.60 spaces per 1,000 square feet in Woodbridge, Virginia, (the lowest Saturday rate) to 1.07 spaces per 1,000 square feet in Houston, Texas (the highest Saturday rate). The average weekday AM peak parking rate for the seven stores was 0.35 spaces per 1,000 square feet. The average weekday PM peak parking rate was 0.47 spaces per 1,000 square feet. The average Saturday peak parking rate was 0.89 spaces per 1,000 square feet. N I-95HIGH RIDGE RDSTORE LOCATION BOYNTON BEACH, FL 33426 1974 HIGH RIDGE ROAD BOYNTON BEACH STORE: AND TRIP GENERATION STUDY FLOOR & DECOR PARKING FIGURE 1 N STORE LOCATION WAYNE, NJ 07470 77 WILLOWBROOK BOULEVARD WAYNE STORE: AND TRIP GENERATION STUDY FLOOR & DECOR PARKING FIGURE 2 W ILLOW BROOK BLVD N LEGSR 23 N STORE LOCATION WOODBRIDGE, VA 22192 14041 WORTH AVENUE POTOMAC MILLS STORE: AND TRIP GENERATION STUDY FLOOR & DECOR PARKING FIGURE 3 POTOMAC MILLS CIRWORTH AVE N STORE LOCATION E DYER RD SANTA ANA, CA 92705 1801 EAST DYER ROAD SANTA ANA STORE: AND TRIP GENERATION STUDY FLOOR & DECOR PARKING FIGURE 4 C OST A ME SA FW YP UL L MAN S T N STORE LOCATION HOUSTON, TX 77090 17211 NORTH FREEWAY NORTH HOUSTON STORE: AND TRIP GENERATION STUDY FLOOR & DECOR PARKING FIGURE 5I-45BAMMEL WESTFIELD RD N FREEWAY SERVICE RDWELLS FARGO DR N STORE LOCATION ARLINGTON HEIGHTS, IL 60004 600 EAST RAND ROAD ARLINGTON HEIGHTS STORE: AND TRIP GENERATION STUDY FLOOR & DECOR PARKING FIGURE 6 E PALATINE RD E RA N D RD N STORE LOCATION BUFORD, GA 30519 2918 BUFORD DRIVE MALL OF GEORGIA STORE: AND TRIP GENERATION STUDY FLOOR & DECOR PARKING FIGURE 7 I-85 BUFORD DR NE Floor & Decor Parking and Trip Generation Study Page 10 March 2017 Table 1: Peak Parking Counts and Rates Store Location and Size Date Peak Time Number of Occupied Spaces Parking Rate (spaces per 1,000 SF GLA) Wed, Jan 25 9:15 AM, 9:30 AM 43 0.47 Wed, Jan 25 4:00 PM 51 0.55 Sat, Jan 28 1:00 PM, 1:15 PM 65 0.71 Thur, Jan 26 9:30 AM 12 0.14 Wed, Jan 25 6:15 PM 28 0.32 Sat, Jan 21 1:30 PM 79 0.89 Thur, July 14, 2016 8:00 AM, 9:30 AM 15 0.20 Wed, July 13, 2016 4:00 PM 30 0.39 Sat, July 9, 2016 1:00 PM, 1:15 PM 46 0.60 Tue, Jan 24 9:15 AM 26 0.36 Tue, Jan 24 4:00 PM 29 0.40 Sat, Jan 21 1:00 PM 75 1.03 Wed, Jan 25 9:30 AM 58 0.53 Tue, Jan 24 4:15 PM 56 0.51 Sat, Jan 21 2:00 PM 117 1.07 Wed, Jan 25 9:30 AM 23 0.31 Wed, Jan 25 4:00 PM, 4:15 PM 36 0.48 Sat, Jan 28 1:00 PM 66 0.88 Tue, Jan 24 9:15 AM 37 0.42 Tue, Jan 24 4:15 PM 56 0.64 Sat, Jan 21 1:30 PM 89 1.01 Average weekday AM peak parking rate of all seven stores:0.35 Average weekday PM peak parking rate of all seven stores:0.47 Average Saturday midday peak parking rate of all seven stores:0.89 Floor & Decor - Boynton Beach 1974 High Ridge Road Boynton Beach, FL 33426 91,916 GLA Floor & Decor - North Houston 17211 North Freeway Houston, TX 77090 109,000 SF GLA Floor & Decor - Mall of Georgia 2918 Buford Drive Buford, GA 30519 87,825 SF GLA Floor & Decor - Wayne 77 Willowbrook Boulevard Wayne, NJ 07470 88,500 SF GLA Floor & Decor - Potomac Mills 14041 Worth Avenue Woodbridge, VA 22192 76,384 SF GLA Floor & Decor - Santa Ana 1801 East Dyer Road Santa Ana, CA 92705 72,914 SF GLA Floor & Decor - Arlington Heights 600 East Rand Road Arlington Heights, IL 60004 74,900 SF GLA Floor & Decor Parking and Trip Generation Study Page 11 March 2017 Results of Trip Generation Data Collection Table 2 presents the results of the trip generation data collection. As shown in Table 2, the peak hour trip generation rates in trips per 1,000 square feet of gross leasable area were higher in the PM peak hour than they were in the AM peak hour for five of the seven stores. The Wayne, New Jersey store experienced the lowest AM peak hour trip generation rate, and the Santa Ana store experienced the lowest PM peak hour trip generation rate. The Boynton Beach store experienced the highest AM peak hour and the highest PM peak hour trip generation rates. The average AM peak hour trip generation rate for the seven stores was 0.45 trips per 1,000 square feet (57 percent inbound, 43 percent outbound). The average PM peak hour trip generation rate was 0.62 trips per 1,000 square feet (50 percent inbound, 50 percent outbound). Floor & Decor Parking and Trip Generation Study Page 12 March 2017 Table 2: Peak Hour Trip Generation Summary Store Location and Size Date Peak Hour Inbound Trips Outbound Trips Total Trips Trip Generation Rate (Trips per 1,000 SF GLA) Inbound Trip Percentage Outbound Trip Percentage Wed, Jan 25, 2017 8:30 AM - 9:30 AM 43 38 81 0.88 53%47% Wed, Jan 25, 2017 4:00 PM - 5:00 PM 40 37 77 0.84 52%48% Thur, Jan 26, 2017 8:30 AM - 9:30 AM 10 5 15 0.17 67%33% Wed, Jan 25, 2017 5:15 PM - 6:15 PM 27 22 49 0.55 55%45% Thur, July 14, 2016 7:30 AM - 8:30 AM 13 15 28 0.37 46%54% Wed, July 13, 2016 5:00 PM - 6:00 PM 18 20 38 0.50 47%53% Tue, Jan 24, 2017 8:15 AM - 9:15 AM 18 17 35 0.48 51%49% Tue, Jan 24, 2017 4:00 PM - 5:00 PM 15 16 31 0.43 48%52% Wed, Jan 25, 2017 8:15 AM - 9:15 AM 28 26 54 0.50 52%48% Tue, Jan 24, 2017 5:30 PM - 6:30 PM 31 33 64 0.59 48%52% Wed, Jan 25, 2017 8:30 AM - 9:30 AM 17 11 28 0.37 61%39% Wed, Jan 25, 2017 5:30 PM - 6:30 PM 24 22 46 0.61 52%48% Tue, Jan 24, 2017 8:30 AM - 9:30 AM 23 11 34 0.39 68%32% Tue, Jan 24, 2017 5:45 PM - 6:45 PM 33 40 73 0.83 45%55% Average AM Peak Hour Trip Generation Rate and Inbound/Outbound Percentage 0.45 Average PM Peak Hour Trip Generation Rate and Inbound/Outbound Percentage 0.62 (57% in, 43% out) (50% in, 50% out) Floor & Decor - Boynton Beach 1974 High Ridge Road Boynton Beach, FL 33426 91,916 SF GLA Floor & Decor - North Houston 17211 North Freeway Houston, TX 77090 109,000 SF GLA Floor & Decor - Mall of Georgia 2918 Buford Drive Buford, GA 30519 87,825 SF GLA Floor & Decor - Potomac Mills 14041 Worth Avenue Woodbridge, VA 22192 76,384 SF GLA Floor & Decor - Wayne 77 Willowbrook Boulevard Wayne, NJ 07470 88,500 SF GLA Floor & Decor - Santa Ana 1801 East Dyer Road Santa Ana, CA 92705 72,914 SF GLA Floor & Decor - Arlington Heights 600 East Rand Road Arlington Heights, IL 60004 74,900 SF GLA Floor & Decor Parking and Trip Generation Study Page 13 March 2017 Summary Table 3 presents the average weekday AM and PM peak parking and trip generation rates as well as the average Saturday peak parking rate for the seven stores. Table 4 presents the highest weekday AM and PM parking and trip generation rates observed as well as the highest Saturday parking rate observed for the seven stores. Table 3: Average Parking and Trip Generation Rates Table 4: Highest Parking and Trip Generation Rates Time Period Average Peak Parking Rate (Occupied Spaces per 1,000 SF GLA) Average Peak Hour Trip Generation Rate (Trips Per Hour Per 1,000 SF GLA) Average Peak Hour Inbound Trip Percentage Average Peak Hour Outbound Trip Percentage AM Peak 0.35 0.45 57% 43% PM Peak 0.47 0.62 50% 50% Saturday Peak 0.89 - AM Peak 0.53 North Houston 0.88 Boynton Beach 53% 47% PM Peak 0.64 Mall of Georgia 0.84 Boynton Beach 52% 48% Saturday Peak 1.07 North Houston - Location of Store with Highest Parking Rate Location of Store with Highest Trip Generation Rate Highest Parking Rate (Occupied Spaces per 1,000 SF GLA) Highest Trip Generation Rate (Trips Per Hour Per 1,000 SF GLA) Time Period Inbound Trip Percentage at Store with Highest Trip Generation Outbound Trip Percentage at Store with Highest Trip Generation Floor & Decor Parking and Trip Generation Study March 2017 Appendix A: Sample Parking and Trip Generation Data Collection Sheets Floor & Decor Parking and Trip Generation Study March 2017 Appendix B: Parking Data Collection 91,916 88,500 Time Parking Count Parking Ratio (spaces/1000 sf)Time Parking Count Parking Ratio (spaces/1000 sf) 7:00 AM 14 0.15 7:00 AM 2 0.02 7:15 AM 13 0.14 7:15 AM 3 0.03 7:30 AM 15 0.16 7:30 AM 2 0.02 7:45 AM 20 0.22 7:45 AM 3 0.03 8:00 AM 26 0.28 8:00 AM 4 0.05 8:15 AM 25 0.27 8:15 AM 4 0.05 8:30 AM 29 0.32 8:30 AM 4 0.05 8:45 AM 35 0.38 8:45 AM 4 0.05 9:00 AM 41 0.45 9:00 AM 6 0.07 9:15 AM 43 0.47 9:15 AM 9 0.10 9:30 AM 43 0.47 9:30 AM 12 0.14 4:00 PM 51 0.55 4:00 PM 19 0.21 4:15 PM 42 0.46 4:15 PM 15 0.17 4:30 PM 39 0.42 4:30 PM 21 0.24 4:45 PM 46 0.50 4:45 PM 16 0.18 5:00 PM 46 0.50 5:00 PM 18 0.20 5:15 PM 39 0.42 5:15 PM 19 0.21 5:30 PM 37 0.40 5:30 PM 24 0.27 5:45 PM 39 0.42 5:45 PM 24 0.27 6:00 PM 30 0.33 6:00 PM 26 0.29 6:15 PM 26 0.28 6:15 PM 28 0.32 6:30 PM 26 0.28 6:30 PM 26 0.29 6:45 PM 30 0.33 6:45 PM 26 0.29 7:00 PM 29 0.32 7:00 PM 23 0.26 11:00 AM 47 0.51 11:00 AM 35 0.40 11:15 AM 55 0.60 11:15 AM 44 0.50 11:30 AM 64 0.70 11:30 AM 54 0.61 11:45 AM 56 0.61 11:45 AM 49 0.55 12:00 PM 52 0.57 12:00 PM 57 0.64 12:15 PM 51 0.55 12:15 PM 58 0.66 12:30 PM 56 0.61 12:30 PM 55 0.62 12:45 PM 62 0.67 12:45 PM 67 0.76 1:00 PM 65 0.71 1:00 PM 70 0.79 1:15 PM 65 0.71 1:15 PM 71 0.80 1:30 PM 61 0.66 1:30 PM 79 0.89 1:45 PM 62 0.67 1:45 PM 73 0.82 2:00 PM 64 0.70 2:00 PM 75 0.85 PM Peak Collected on Wednesday, January 25, 2017 PM Peak Collected on Tuesday, January 24, 2017 Saturday Peak Collected on Saturday, January 28, 2017 Saturday Peak Collected on Saturday, January 21, 2017 Floor & Decor Parking Data Collection Boynton Beach, Florida Wayne, New Jersey Store Size (square feet)Store Size (square feet) AM Peak Collected on Wednesday, January 25, 2017 AM Peak Collected on Tuesday, January 24, 2017 Boynton Beach Wayne 76,384 72,914 Time Parking Count Parking Ratio (spaces/1000 sf)Time Parking Count Parking Ratio (spaces/1000 sf) 7:00 AM 5 0.07 7:00 AM 9 0.12 7:15 AM 9 0.12 7:15 AM 12 0.16 7:30 AM 11 0.14 7:30 AM 12 0.16 7:45 AM 12 0.16 7:45 AM 12 0.16 8:00 AM 15 0.20 8:00 AM 14 0.19 8:15 AM 13 0.17 8:15 AM 16 0.22 8:30 AM 9 0.12 8:30 AM 22 0.30 8:45 AM 10 0.13 8:45 AM 19 0.26 9:00 AM 12 0.16 9:00 AM 23 0.32 9:15 AM 13 0.17 9:15 AM 26 0.36 9:30 AM 15 0.20 9:30 AM 25 0.34 4:00 PM 30 0.39 4:00 PM 29 0.40 4:15 PM 28 0.37 4:15 PM 22 0.30 4:30 PM 21 0.27 4:30 PM 26 0.36 4:45 PM 21 0.27 4:45 PM 23 0.32 5:00 PM 21 0.27 5:00 PM 18 0.25 5:15 PM 18 0.24 5:15 PM 23 0.32 5:30 PM 19 0.25 5:30 PM 14 0.19 5:45 PM 20 0.26 5:45 PM 14 0.19 6:00 PM 19 0.25 6:00 PM 16 0.22 6:15 PM 16 0.21 6:15 PM 15 0.21 6:30 PM 17 0.22 6:30 PM 22 0.30 6:45 PM 19 0.25 6:45 PM 21 0.29 7:00 PM 23 0.30 7:00 PM 20 0.27 11:00 AM 38 0.50 11:00 AM 59 0.81 11:15 AM 33 0.43 11:15 AM 66 0.91 11:30 AM 34 0.45 11:30 AM 67 0.92 11:45 AM 39 0.51 11:45 AM 60 0.82 12:00 PM 32 0.42 12:00 PM 62 0.85 12:15 PM 37 0.48 12:15 PM 68 0.93 12:30 PM 44 0.58 12:30 PM 67 0.92 12:45 PM 45 0.59 12:45 PM 68 0.93 1:00 PM 46 0.60 1:00 PM 75 1.03 1:15 PM 46 0.60 1:15 PM 70 0.96 1:30 PM 40 0.52 1:30 PM 74 1.01 1:45 PM 32 0.42 1:45 PM 70 0.96 2:00 PM 37 0.48 2:00 PM 60 0.82 Saturday Peak Collected on Saturday, July 9, 2016 Saturday Peak Collected on Saturday, January 21, 2017 Store Size (square feet)Store Size (square feet) AM Peak Collected on Thursday, July 14, 2016 AM Peak Collected on Tuesday, January 24, 2017 PM Peak Collected on Wednesday, July 13, 2016 PM Peak Collected on Tuesday, January 24, 2017 Floor & Decor Parking Data Collection Woodbridge, Virginia Santa Ana, California Potamac Mills Santa Ana 109,000 74,900 Time Parking Count Parking Ratio (spaces/1000 sf)Time Parking Count Parking Ratio (spaces/1000 sf) 7:00 AM 22 0.20 7:00 AM 8 0.11 7:15 AM 41 0.38 7:15 AM 11 0.15 7:30 AM 37 0.34 7:30 AM 10 0.13 7:45 AM 35 0.32 7:45 AM 10 0.13 8:00 AM 39 0.36 8:00 AM 12 0.16 8:15 AM 44 0.40 8:15 AM 13 0.17 8:30 AM 49 0.45 8:30 AM 14 0.19 8:45 AM 49 0.45 8:45 AM 18 0.24 9:00 AM 56 0.51 9:00 AM 17 0.23 9:15 AM 54 0.50 9:15 AM 21 0.28 9:30 AM 58 0.53 9:30 AM 23 0.31 4:00 PM 54 0.50 4:00 PM 36 0.48 4:15 PM 56 0.51 4:15 PM 36 0.48 4:30 PM 54 0.50 4:30 PM 35 0.47 4:45 PM 50 0.46 4:45 PM 29 0.39 5:00 PM 48 0.44 5:00 PM 33 0.44 5:15 PM 43 0.39 5:15 PM 34 0.45 5:30 PM 52 0.48 5:30 PM 28 0.37 5:45 PM 44 0.40 5:45 PM 29 0.39 6:00 PM 52 0.48 6:00 PM 30 0.40 6:15 PM 46 0.42 6:15 PM 29 0.39 6:30 PM 47 0.43 6:30 PM 29 0.39 6:45 PM 41 0.38 6:45 PM 25 0.33 7:00 PM 37 0.34 7:00 PM 21 0.28 11:00 AM 81 0.74 11:00 AM 41 0.55 11:15 AM 79 0.72 11:15 AM 36 0.48 11:30 AM 83 0.76 11:30 AM 45 0.60 11:45 AM 91 0.83 11:45 AM 46 0.61 12:00 PM 91 0.83 12:00 PM 43 0.57 12:15 PM 90 0.83 12:15 PM 47 0.63 12:30 PM 89 0.82 12:30 PM 48 0.64 12:45 PM 88 0.81 12:45 PM 52 0.69 1:00 PM 101 0.93 1:00 PM 66 0.88 1:15 PM 105 0.96 1:15 PM 65 0.87 1:30 PM 90 0.83 1:30 PM 55 0.73 1:45 PM 100 0.92 1:45 PM 50 0.67 2:00 PM 117 1.07 2:00 PM 49 0.65 AM Peak Collected on Wednesday, January 25, 2017 AM Peak Collected on Thursday, January 19, 2017 PM Peak Collected on Tuesday, January 24, 2017 PM Peak Collected on Thursday, January 19, 2017 Saturday Peak Collected on Saturday, January 21, 2017 Saturday Peak Collected on Saturday, January 28, 2017 Floor & Decor Parking Data Collection Houston, Texas Arlington Heights, Illinois Store Size (square feet)Store Size (square feet) North Houston Arlington Heights 87,825 Time Parking Count Parking Ratio (spaces/1000 sf) 7:00 AM 13 0.15 7:15 AM 17 0.19 7:30 AM 20 0.23 7:45 AM 16 0.18 8:00 AM 18 0.20 8:15 AM 21 0.24 8:30 AM 23 0.26 8:45 AM 24 0.27 9:00 AM 29 0.33 9:15 AM 37 0.42 9:30 AM 33 0.38 4:00 PM 53 0.60 4:15 PM 56 0.64 4:30 PM 52 0.59 4:45 PM 48 0.55 5:00 PM 46 0.52 5:15 PM 43 0.49 5:30 PM 36 0.41 5:45 PM 32 0.36 6:00 PM 29 0.33 6:15 PM 28 0.32 6:30 PM 37 0.42 6:45 PM 34 0.39 7:00 PM 36 0.41 11:00 AM 63 0.72 11:15 AM 65 0.74 11:30 AM 71 0.81 11:45 AM 62 0.71 12:00 PM 64 0.73 12:15 PM 75 0.85 12:30 PM 79 0.90 12:45 PM 76 0.87 1:00 PM 84 0.96 1:15 PM 88 1.00 1:30 PM 89 1.01 1:45 PM 74 0.84 2:00 PM 73 0.83 Floor & Decor Parking Data Collection Mall of Georgia Buford, Georgia Store Size (square feet) AM Peak Collected on Tuesday, January 24, 2017 PM Peak Collected on Tuesday, January 24, 2017 Saturday Peak Collected on Saturday, January 21, 2017 Floor & Decor Parking and Trip Generation Study March 2017 Appendix C: Trip Generation Data Collection 91,916 88,500 Time Period Inbound trips Outbound trips Total trips Peak Hour Trip Generation (trips/1000 sf) Time Period Inbound trips Outbound trips Total trips Peak Hour Trip Generation (trips/1000 sf) 7:00 - 7:15 7 4 11 7:00 - 7:15 0 0 0 7:15 - 7:30 2 2 4 7:15 - 7:30 0 0 0 7:30 - 7:45 5 1 6 7:30 - 7:45 1 0 1 7:45 - 8:00 6 6 12 7:45 - 8:00 1 0 1 8:00 - 8:15 9 5 14 8:00 - 8:15 2 2 4 8:15 - 8:30 6 2 8 8:15 - 8:30 1 1 2 8:30 - 8:45 6 6 12 8:30 - 8:45 2 2 4 8:45 - 9:00 12 13 25 8:45 - 9:00 2 1 3 9:00 - 9:15 16 12 28 9:00 - 9:15 3 1 4 9:15 - 9:30 9 7 16 9:15 - 9:30 3 1 4 4:00 - 4:15 9 12 21 4:00 - 4:15 3 6 9 4:15 - 4:30 9 10 19 4:15 - 4:30 4 4 8 4:30 - 4:45 11 10 21 4:30 - 4:45 3 3 6 4:45 - 5:00 11 5 16 4:45 - 5:00 5 2 7 5:00 - 5:15 5 14 19 5:00 - 5:15 4 3 7 5:15 - 5:30 7 5 12 5:15 - 5:30 8 3 11 5:30 - 5:45 7 9 16 5:30 - 5:45 5 6 11 5:45 - 6:00 3 11 14 5:45 - 6:00 8 5 13 6:00 - 6:15 4 6 10 6:00 - 6:15 6 8 14 6:15 - 6:30 5 8 13 6:15 - 6:30 7 3 10 6:30 - 6:45 9 7 16 6:30 - 6:45 5 7 12 6:45 - 7:00 4 0 4 6:45 - 7:00 4 8 12 76,384 72,914 Time Period Inbound trips Outbound trips Total trips Peak Hour Trip Generation (trips/1000 sf) Time Period Inbound trips Outbound trips Total trips Peak Hour Trip Generation (trips/1000 sf) 7:00 - 7:15 5 1 6 7:00 - 7:15 0 0 0 7:15 - 7:30 3 1 4 7:15 - 7:30 2 1 3 7:30 - 7:45 4 3 7 7:30 - 7:45 2 1 3 7:45 - 8:00 7 4 11 7:45 - 8:00 1 1 2 8:00 - 8:15 1 3 4 8:00 - 8:15 6 1 7 8:15 - 8:30 1 5 6 8:15 - 8:30 7 4 11 8:30 - 8:45 3 2 5 8:30 - 8:45 5 5 10 8:45 - 9:00 2 0 2 8:45 - 9:00 1 5 6 9:00 - 9:15 3 2 5 9:00 - 9:15 5 3 8 9:15 - 9:30 5 3 8 9:15 - 9:30 3 4 7 4:00 - 4:15 5 7 12 4:00 - 4:15 2 4 6 4:15 - 4:30 2 9 11 4:15 - 4:30 6 1 7 4:30 - 4:45 4 4 8 4:30 - 4:45 5 6 11 4:45 - 5:00 3 3 6 4:45 - 5:00 2 5 7 5:00 - 5:15 4 7 11 5:00 - 5:15 1 4 5 5:15 - 5:30 4 3 7 5:15 - 5:30 4 3 7 5:30 - 5:45 6 5 11 5:30 - 5:45 2 4 6 5:45 - 6:00 4 5 9 5:45 - 6:00 2 0 2 6:00 - 6:15 2 5 7 6:00 - 6:15 2 1 3 6:15 - 6:30 5 4 9 6:15 - 6:30 5 1 6 6:30 - 6:45 7 5 12 6:30 - 6:45 2 3 5 6:45 - 7:00 7 3 10 6:45 - 7:00 5 5 10 0.50 Santa Ana 0.48 0.43 0.88 0.17 0.84 0.55 AM Peak Collected on Thursday, July 14, 2016 AM Peak Collected on Tuesday, January 24, 2017 PM Peak Collected on Wednesday, July 13, 2016 PM Peak Collected on Tuesday, January 24, 2017 0.37 PM Peak Collected on Wednesday, January 25, 2017 PM Peak Collected on Tuesday, January 24, 2017 Woodbridge, Virginia Santa Ana, California Store Size (square feet)Store Size (square feet) Potomac Mills Floor & Decor Trip Generation Data Collection Boynton Beach, Florida Wayne, New Jersey Store Size (square feet)Store Size (square feet) AM Peak Collected on Wednesday, January 25, 2017 AM Peak Collected on Tuesday, January 24, 2017 Boynton Beach Wayne 109,000 74,900 Time Period Inbound trips Outbound trips Total trips Peak Hour Trip Generation (trips/1000 sf) Time Period Inbound trips Outbound trips Total trips Peak Hour Trip Generation (trips/1000 sf) 7:00 - 7:15 6 1 7 7:00 - 7:15 6 2 8 7:15 - 7:30 5 4 9 7:15 - 7:30 3 2 5 7:30 - 7:45 4 4 8 7:30 - 7:45 1 2 3 7:45 - 8:00 7 3 10 7:45 - 8:00 4 1 5 8:00 - 8:15 9 3 12 8:00 - 8:15 3 2 5 8:15 - 8:30 9 8 17 8:15 - 8:30 3 2 5 8:30 - 8:45 6 7 13 8:30 - 8:45 2 1 3 8:45 - 9:00 6 5 11 8:45 - 9:00 3 3 6 9:00 - 9:15 7 6 13 9:00 - 9:15 6 2 8 9:15 - 9:30 7 2 9 9:15 - 9:30 6 5 11 4:00 - 4:15 6 6 12 4:00 - 4:15 3 6 9 4:15 - 4:30 6 8 14 4:15 - 4:30 8 4 12 4:30 - 4:45 8 14 22 4:30 - 4:45 2 3 5 4:45 - 5:00 7 5 12 4:45 - 5:00 10 2 12 5:00 - 5:15 3 7 10 5:00 - 5:15 4 3 7 5:15 - 5:30 8 3 11 5:15 - 5:30 4 3 7 5:30 - 5:45 5 10 15 5:30 - 5:45 5 6 11 5:45 - 6:00 10 5 15 5:45 - 6:00 8 5 13 6:00 - 6:15 6 7 13 6:00 - 6:15 3 8 11 6:15 - 6:30 10 11 21 6:15 - 6:30 8 3 11 6:30 - 6:45 7 7 14 6:30 - 6:45 4 7 11 6:45 - 7:00 6 7 13 6:45 - 7:00 3 8 11 87,825 Time Period Inbound trips Outbound trips Total trips Peak Hour Trip Generation (trips/1000 sf) 7:00 - 7:15 6 2 8 7:15 - 7:30 4 2 6 7:30 - 7:45 1 4 5 7:45 - 8:00 4 2 6 8:00 - 8:15 3 1 4 8:15 - 8:30 6 3 9 8:30 - 8:45 3 2 5 8:45 - 9:00 5 3 8 9:00 - 9:15 9 2 11 9:15 - 9:30 6 4 10 4:00 - 4:15 7 9 16 4:15 - 4:30 7 8 15 4:30 - 4:45 5 13 18 4:45 - 5:00 5 10 15 5:00 - 5:15 5 6 11 5:15 - 5:30 3 10 13 5:30 - 5:45 3 9 12 5:45 - 6:00 3 10 13 6:00 - 6:15 6 8 14 6:15 - 6:30 15 8 23 6:30 - 6:45 9 14 23 6:45 - 7:00 6 4 10 PM Peak Collected on Tuesday, January 24, 2017 0.39 0.83 Mall of Georgia Buford, Georgia Store Size (square feet) AM Peak Collected on Tuesday, January 24, 2017 Arlington Heights 0.37 0.61 North Houston 0.50 0.59 Store Size (square feet)Store Size (square feet) AM Peak Collected on Wednesday, January 25, 2017 AM Peak Collected on Thursday, January 19, 2017 PM Peak Collected on Tuesday, January 24, 2017 PM Peak Collected on Thursday, January 19, 2017 Floor & Decor Trip Generation Data Collection Houston, Texas Arlington Heights, Illinois FOUR (4) CUSTOMER PICKUP PARKING STALLS TOW-AWAY AND NO DUMPING SIGNS EVERY 100' ALONG INSIDE FENCE 3 C3.00 8' CUSTOMER LOADING PASSING LANE 3 TOW-AWAY AND NO DUMPING SIGNAGE 336'-2"135'-8"26'-5"174'-0"20'-0"29'-9"20'-0"69'-9"50'-0"12'-0"12'-0"55'-1"133'-8"24'-0"37'-8"24'-0"24'-0"24'-0"9'-0"240'-0"24'-0"24'-0"24'-0"24'-0"24'-0"24'-0"24'-0"24'-0"24'-0"24'-0"17'-11"24'-0"18'-0"59'-11"5'-4"45'-0"9'-0"5'-0"9'-0"45'-1"118'-5"1'-8"54'-0"5'-0"9'-0"45'-0"18'-0"23'-11"18'-1"2'-1"20'-0"24'-0"20'-0"9'-0"36'-0"48'-3"3'-3"5'-5"5'-9"1656'2417'886'1691'2382'900'892'S SLOPEDOWN 69,750 SQ.FT.GLASLOPE DOWN5'-2"23'-7"NORTHSCALE:1REFERENCE SITE PLAN1" = 20'-0"as1SITE PLAN GENERAL NOTES1. THIS IS A GENERIC LAYOUT SHOWN. COORDINATE WITH CIVIL.2. SIGNAGE LOCATIONS ARE FOR REFERENCE ONLY AND ARE NOT PART OF THIS PERMITPACKAGE.3. PROVIDE A FLUSH CURB CONDITION ALONG FRONT OF BUILDING, REFER TO CIVILDRAWINGS.STRIPING STANDARDSTRIPING COLOR SCHEDULEITEM:COLOR:PARKING STALLWHITELETTERING "NO PARKING"RED"STOP BAR"WHITEACCESSIBILITY SYMBOLBLUE / WHITE SYMBOLSACCESSIBLE LOADINGBLUELOADING ZONEYELLOWDIRECTIONAL SIGNAGEWHITECENTER LINE STRIPINGWHITENOTE: ALKYD-READY MIXED, RAPID DRYING TRAFFIC PAVEMENTSTRIPING. DRY FILM THICKNESS MINIMUM OF 4 MILS.LEGENDDETECTABLE WARNINGDETECTABLE WARNING SURFACES SHALL CONTRAST VISUALLYWITH ADJACENT WALKING SURFACES EITHER LIGHT-ON-DARK ORDARK-ON-LIGHT. THE MATERIAL USED TO PROVIDE CONTRASTSHALL BE AN INTEGRAL PART OF THE SURFACE. (SEC.11B-705.1.13)DETECTABLE WARNING SURFACES SHALL BE YELLOW CONFORMINGTO (FS 33538) OF FEDERAL STANDARD 595C (SEC. 11B-705.1.1.5)= HEAVY DUTY ASPHALT.KEY NOTESEXISTING DRIVEWAY ACCESS N.I.C.EXISTING PARKING FIELD, N.I.C.NEW CONCRETE SLAB ON GRADE AT TRUCK LOADING AREA.NEW PARKING FIELDNEW PARKING ISLANDEXISTING RETAINING WALLNEW FLUSH CURB CONDITIONEXISTING SIDEWALK TO REMAIN, TYP.EXISTING SITE LIGHTING TO REMAINEXISTING TRANSFORMER AND VAULT LOCATIONEXISTING FIRE HYDRANT, TYP.NEW AUTOMATIC DOOR SLIDERS AT MAIN ENTRANCE/EXITEXISTING TELEPHONE/ELECTRICAL BOX LOCATIONNEW ACCESS RAMPACCESSIBLE PATH OF TRAVEL TO PUBLIC RIGHT OF WAYEXISTING STRUCTURE TO BE REMOVED12345678910111213LIMITS OF SCOPE OF WORKLIMITS OF SCOPE OF WORKLIMITS OF SCOPE OF WORK224444412114EXISTING DOORTO REMAINEXISTINGDRIVEWAYACCESS, N.I.C.NEW OFFICE'S, RESTROOMS,CASH AND VAULT ROOM'S, ANDCUSTODIAL AREA, SEE A101NEW 12' W. x 10' H.ROLL UP DOORPROPOSED TRASHCOMPACTOR W/NEW CONC. SLABON GRADE55PROPOSEDCOMPACTVEHICLE SPACES4PROPOSED TRUCKLOADING DOCKS555EXISTING GATETO REMAIN1043NOTE:SITE PLAN SHOWN FOR REFERENCE ONLY.NO SITE IMPROVEMENTS ARE BEINGMADE-ALL CONDITIONS ARE EXISTING.EXISTING DOORTO REMAINEXISTING DRILLRIGHT OF WAYEXISTING FIRERISER9TYP.8TYP.8TYP.8TYP.EXISTING CHAINLINK FENCEEXISTING CHAINLINK FENCE4LIMITS OF SCOPE OF WORKLIMITS OF SCOPE OF WORK 3NEW AUTOMATICDOOR SLIDERNEW ROOFACCESSFLOOR AREAEXISTING AREA: 72,068 S.F.AREA REMOVED: 2,318 S.F.REMAINING GLA AREA: 69,750 S.F.CCCCCCCCCCCCCCCCCC1619161912125682EXIT-A104" CLEAR WIDTHPER 1010.1.9.3 OF THE 2016 CALIFORNIA BUILDING CODE:A READILY VISIBLE DURABLE SIGN IS POSTED ON THE EGRESS SIDE ON OR ADJACENT TOTHE DOOR STATING: THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED.THE SIGN SHALL BE IN LETTERS 1 INCH (25 MM) HIGH ON A CONTRASTING BACK- GROUND.ACCESSIBLE EXITEXIT-B84" CLEAR WIDTHACCESSIBLE EXITCANOPY ABOVE, TYP5EXISTING PUBLICRIGHT OF WAYEXISTING PUBLICRIGHT OF WAY14141415151516161616NOTE:1. USING ADA STANDARDS TO GAINFULL ACCESS COMPLIANCE.2. THE PROJECT WILL COMPLY WITHTHE 2016 CALIFORNIA BUILDING CODE, 2016CALIFORNIA RESIDENTAL CODE (WHEREAPPLICABLE), 2016 CALIFORNIAMECHANICAL CODE, 2016 CALIFORNIAELECTRICAL CODE, AND 2016 CALIFORNIAPLUMBING CODE, INDLUDING ALLAMENDMENTS AS ADOPTED IN ORDINANCE1889.3. WHEN PLANS ARE SUBMITTED FORBUILDING CODE PLAN CHECK, THEY WILLINCLUDE A COMPLETE UNDERGROUNDPLUMBING PLAN INCLUDING COMPLETEDETAILS FOR THE LOCATION OF ALLCITY-REQUIRED BACKWATER PREVENTIONDEVICES.This drawing is an instrument of service and the property of Stewart + Reindersma Architecture, pllc, and shall remain their property. The use of this drawing shall be restricted to the original site for which it is prepared and publication thereof is expressly limited to such use.----Sake reindersmaa r c h i t e c t360DESIGN REVIEW02/02/1817-072----L IC E N SED ARCHITECTSAKE H ARM REINDERSMASTATE OF CALI F O R NIA02-02-2018AREAOCCUPANTLOAD FACTORUSEOCCUPANTLOAD57,828 SF60 GROSSMERCANTILE (M)9648,819 SF300 GROSSSTORAGE, STOCK, SHIPPING,MECHANICAL / ELECTRICAL,DESIGN BUILD ROOM (S1)303,103 SF100 GROSSOFFICE (B)32TOTAL OCCUPANT LOAD 69,750 SF 1,026OCCUPANT LOAD III-NTYPE OF CONSTRUCTIONUNLIMITED (60' YARD ON ALL 4 SIDES)60 GROSSALLOWABLE AREA35'-0"PROPOSED HEIGHTFIRE PROTECTIONBUILDING DATAFULLY SPRINKLERED 20'-0"20'-0"20'-0"NORTH41'-1"20'-0"20'-0"20'-0"20'-0"20'-0"20'-4"FIRE RISEREXISTINGCOLUMN, TYPMANATOWOCUY-0140AICE MAKEREXISTING STRUCTURALCROSS BRACING TOREMAIN, TYPGAS, TYP4'-0"9'-0"CLEARM.O.EXISTING ROOF DRAINLEADER TO REMAIN, TYPCOMPACTOR DOOR2'-10"47'-11 1/2"EXISTING STRUCTURAL'K' BRACING TO REMIAN, TYPNEW COMPACTORNEW ENTRYEXISTING 'K' BRACINGCAN BE REMOVED IFNECESSARYS MONITOR COFFEVENDINGMONITORU/CSAFE13'-0"4'-2"SLOPEDOWN 3'-4"20'-0"75'-3"75'-0"75'-0"75'-3"300'-6"EXISTING ELECTRICALPANELS261'-5" 20'-0"(12) TOTAL - EXISTING ROOFDRAIN, TYPEXISTING ELECTRICALJUNCTION BOX AT BOTTOMOF STRUCTURE, TYP69,750 SQ.FT.GLANEW HOSE BIB PERPROTO23'-10"13'-0"EXISTING WALLTO REMAIN, TYPEXISTING ROOF LEADER TOBE RELOCATED, TYP3'-4"NEW CANOPY -ABOVE, TYPNEW CONCRETE PADTRSH.MKR.9'-0"CLEARM.O.23'-10"NEW SCREEN WALL3'-4"3'-8"VENDINGABCDEFGHJKL54321M2'-10"49'-11 1/2"180'-0"41'-1"4'-4"17'-2" 4'-6" 6'-10"44'-6"224'-8"3'-5"12'-0"25'-2"5'-0"15'-3"4'-10" 32'-9" 4'-4"14'-0"NEW OPENING #27'-8"25'-1 1/2"14'-7 1/2"6'-0"INFILL OPENING2'-9"22'-7"24'-10"5'-0"CLR.5'-0"25'-10 1/2"12'-0"PRO PICK UPROLL UP DOOR8'-0" CUPU DOOR SLIDER 3'-8"11'-0"EXISTING OPENING14'-0"NEW OPENING #411'-0"INFILLOPENING7'-8"3'-8"11'-0"NEW OPENING #51'-8"V.I.F.5'-0"CLR.5'-2"CLR.5'-0"CLR.1'-6"5'-7"17'-7"5'-11 1/2"3'-0"15'-6 1/2"2'-6"2'-0"2'-0"DEMO THISPORTION OFWALL11'-0"EXISTINGOPENING14'-0"NEW OPENING #3NEW INFILLDEMO THISPORTION OFWALL11'-0"NEW OPENING #11'-6"INFILL OPENING11'-0"EXISTING OPENINGV.I.F. EXISTINGOPENING19'-7"DEMO THISPORTION OFWALLDEMO THISPORTION OFWALLSLOPE DOWN 3'-0"CART LOCATIONSTRUCTURE TOBE REMOVEDSCALE:1FLOOR PLAN3/32" = 1'-0"a21/A44/A42/A4 3/A4 This drawing is an instrument of service and the property of Stewart + Reindersma Architecture, pllc, and shall remain their property. The use of this drawing shall be restricted to the original site for which it is prepared and publication thereof is expressly limited to such use.----Sake reindersmaa r c h i t e c t360DESIGN REVIEW02/02/1817-072----L IC E N SED ARCHITECTSAKE H ARM REINDERSMASTATE OF CALI F O R NIA02-02-2018EXIT-A104" CLEAR WIDTHACCESSIBLE EXITEXIT-B84" CLEAR WIDTHACCESSIBLE EXIT 20'-0"20'-0"20'-0"NORTH41'-1"20'-0"20'-0"20'-0"20'-0"20'-0"20'-4"MLL220'-0"75'-3"75'-0"75'-0"75'-3"300'-6"261'-5" 20'-0"M1112ABCDEFGHJKL54321M121LSCALE:1EXISTING TENANT ROOF PLAN3/32" = 1'-0"a3EXISTING ROOFEQUIP. - TYP.EXISTING ROOFUNITS - TYP.EXISTING ROOFEQUIP. - TYP.EXISTING ROOFEQUIP. - TYP.EXISTING ROOFEQUIP. - TYP.ROOF SLOPEEXISTINGROOF SLOPEEXISTINGROOF SLOPEEXISTINGROOF SLOPEEXISTINGROOF SLOPE EXISTING ROOF SLOPE EXISTING ROOF SLOPE EXISTING ROOF SLOPE EXISTING ROOF SLOPEEXISTING ROOF SLOPEEXISTING ROOF SLOPE EXISTING ROOF SLOPE EXISTING ROOF SLOPEEXISTING ROOF SLOPE EXISTING ROOF SLOPE EXISTING ROOF SLOPEEXISTING EXISTING ROOFSYSTEMEXISTING ROOFSYSTEMEXISTING ROOFSYSTEMROOF SLOPEEXISTINGPROPOSED NEWROOF ACCESSHATCHEXISTING ROOFPARAPET - TYP.EXISTING ROOFPARAPET - TYP.EXISTING ROOFDRAIN - TYP.EXISTING ROOFDRAIN - TYP.EXISTING ROOFDRAIN - TYP.EXISTING ROOFDRAIN - TYP.EXISTING CANOPYTO REMAIN AND TOBE REFURBISHED -TYP.PROPOSED NEWCANOPY - TYP.PROPOSED NEWCANOPY - TYP.EXISTING CANOPYTO REMAIN AND TOBE REFURBISH - TYP.This drawing is an instrument of service and the property of Stewart + Reindersma Architecture, pllc, and shall remain their property. The use of this drawing shall be restricted to the original site for which it is prepared and publication thereof is expressly limited to such use.----Sake reindersmaa r c h i t e c t360DESIGN REVIEW02/02/1817-072----L IC E N SED ARCHITECTSAKE H ARM REINDERSMASTATE OF CALI F O R NIA02-02-2018 123P1P2P3EXISTING ROOFBEYOND45S3P413'-4"B.O. CANOPYP1P3NEW PILASTEREXISTING WINDOW SYSTEM TO BEREPLACED-MATCH EXISTINGNEW PILASTERS3S2S1P1NEW EXTENDEDPARAPET0'-0"FIN. FLOOR35'-0"T.O. TOWER A.F.F.32'-6"T.O. PILASTER20'-8"T.O. PARAPETNEW CANOPYNEW EXTENDEDPARAPET BEYONDNEW EXTENDEDPARAPET14'-0"T.O. NEW CANOPY14'-0" EXISTING DECK HEIGHT NEW CANOPY(MATCH EXISTINGCANOPY)20'-9"T.O. (E) TILT PANELNEWPILASTERNEW COLUMNS FLUSH W/ BLDGEXTERIORTHIS NOT CONFIRMEDP2CEGJKMBDFHL0'-0"FIN. FLOOR20'-7"T.O. PARAPETEXISTING ROOFBEYONDNEW PILASTEREXISTING WALLREVEALNEW ROLLUP DOORP2P4EXISTING BOLLARDSAND FIRE RISERPIPESP4P4EXISTINGLIGHTING, TYP.P1P1P2P3PARAPET WALLLBEYOND16'-6"T.O. PILASTER13'-4"+/-B.O. EXISTINGP1P3P2P3S3S3S2S1P4P1P2NEW AUTOMATICDOOR SLIDERNEW LOADING DOCKSWITH NEW ROLL-UPDOORSEXISTINGCANOPYTO REMAINNEW CANOPYCANOPY24'-8"T.O. PARAPETTRASH COMPACTORLOCATION (BEYOND)NEW SAFETYRAILS AND RAMPP410'-0"T.O. SCREEN WALLNEW PILASTERCEJKMBDFHAL24'-7"T.O. PARAPET0'-0"FIN. FLOOREXISTING ROOFBEYONDEXISTING WALLREVEALEXISTING WALLREVEALP1P2P3EXISTING GAS METERNEW DOOR0'-0"FIN. FLOOR (EXISTING) 20'-10" +/-T.O. PARAPETNEW EXTENDEDPARAPETREFURBISH EXISTINGCANOPY TO REMAIN39'-9"14'-0"1'-412"1'-412"P4S3S3P1NEW AUTOMATICSTOREFRONT SLIDINGDOORSP335'-0" A.F.F.T.O. PARAPETG14'-0"T.O. NEW CANOPY15'-0"T.O. (E) PARAPET32'-6" A.F.F.T.O. TOWER12345P1P1EXISTING ROOFBEYONDIN-FILL AREASTO BE PAINTEDIN-FILL AREASTO BE PAINTEDTRASH COMPACTORLOCATIONTRASH COMPACTORDOORP40'-0"FIN. FLOOR (EXISTING) 20'-10" +/-T.O. PARAPET+/- 13'-4"B.O. EXISTINGNEW PARAPET BEYONDCANOPY10'-0"T.O. NEWSCREENSCALE:1NORTH ELEVATION3/32" = 1'-0"SCALE:2EAST ELEVATION3/32" = 1'-0"SCALE:3WEST ELEVATION3/32" = 1'-0"SCALE:4SOUTH ELEVATION3/32" = 1'-0"This drawing is an instrument of service and the property of Stewart + Reindersma Architecture, pllc, and shall remain their property. The use of this drawing shall be restricted to the original site for which it is prepared and publication thereof is expressly limited to such use.----Sake reindersmaa r c h i t e c t360DESIGN REVIEW02/02/1817-072----L IC E N SED ARCHITECTSAKE H ARM REINDERSMASTATE OF CALI F O R NIA02-02-2018a4 0'-0"FINISH FLOOR20'-8"T.O. EXISTING PARAPET25'-0"T.O. EXISTING ROOF 15'-0" T.O. EXISTING PARAPETP1P2P3EXISTING ROOFBEYONDS3P413'-4"B.O. CANOPYP1P3NEW PILASTEREXISTING WINDOW SYSTEM TO BEREPLACED-MATCH EXISTINGNEW PILASTERS3S2S1P1NEW EXTENDEDPARAPET0'-0"FIN. FLOOR35'-0"T.O. TOWER A.F.F.32'-6"T.O. PILASTER20'-8"T.O. PARAPETNEW CANOPYNEW EXTENDEDPARAPET BEYONDNEW EXTENDEDPARAPET14'-0"T.O. NEW CANOPY14'-0" EXISTING DECK HEIGHT NEW CANOPY(MATCH EXISTINGCANOPY)20'-9"T.O. (E) TILT PANELNEWPILASTERNEW COLUMNS FLUSH W/ BLDGEXTERIORTHIS NOT CONFIRMED0'-0"FINISH FLOOR20'-8"T.O. EXISTING PARAPET25'-0"T.O. EXISTING ROOF 15'-4"T.O. EXISTING CANOPY0'-0"FINISH FLOOR20'-8"T.O. EXISTING PARAPET25'-0"T.O. EXISTING ROOF 15'-0" T.O. EXISTING PARAPETP20'-0"FIN. FLOOR20'-7"T.O. PARAPETEXISTING ROOFBEYONDNEW PILASTEREXISTING WALLREVEALNEW ROLLUP DOORP2P4EXISTING BOLLARDSAND FIRE RISERPIPESP4P4EXISTINGLIGHTING, TYP.P1P1P2P3PARAPET WALLLBEYOND16'-6"T.O. PILASTER13'-4"+/-B.O. EXISTINGP1P3P2P3S3S3S2S1P4P1P2NEW AUTOMATICDOOR SLIDERNEW LOADING DOCKSWITH NEW ROLL-UPDOORSEXISTINGCANOPYTO REMAINNEW CANOPYCANOPY24'-8"T.O. PARAPETTRASH COMPACTORLOCATION (BEYOND)NEW SAFETYRAILS AND RAMPP410'-0"T.O. SCREEN WALLNEW PILASTERSCALE:1EXISTING NORTH ELEVATION3/32" = 1'-0"SCALE:2PROPOSED NORTH ELEVATION3/32" = 1'-0"SCALE:3EXISTING EAST ELEVATION3/32" = 1'-0"SCALE:4PROPOSED EAST ELEVATION3/32" = 1'-0"a5EXTERIOR COLOR LEGEND1. WHEN THE ENTRY EIFS IS FIELD APPLIED, FINISH TO BE PAINTED WITHSTO COAT ACRYL PLUS STO COLOR NA17-0036.2. ALL STOLITE PANELS ( S1, S2, AND S3) WILL BE FABRICATED WITH THESTO COLOR ACRYLIC PLUS COATING ( PROTECTIVE COATING) ALREADYAPPLIED AND WILL EXTEND ALL THE WAY UP.GENERAL NOTES:LAST UPDATE: 12/12/2017E1E2STO COLOR: NA17-0034 - "HIGH REFLECTIVE WHITE"EIFS FINISH: #194 STOLIT LOTUSAN LIMESTONESTO COLOR: NA17-0035 - "DORIAN GRAY"EIFS FINISH: #194 STOLIT LOTUSAN LIMESTONESTO COLOR: NA17-0030 - "URBANE BRONZE"EIFS FINISH: #194 STOLIT LOTUSAN LIMESTONEEIFS SAND BLAST FINISH COLOR TO MATCH SHERWIN WILLIAMS 6868"REAL RED"STO COLOR: NA17-0034 - "HIGH REFLECTIVE WHITE"STO LITE EIFS PANELS: #194 STOLIT LOTUSAN LIMESTONESTO COLOR: NA17-0035 - "DORIAN GRAY"STO LITE EIFS PANELS: #194 STOLIT LOTUSAN LIMESTONESTO COLOR: NA17-0030 - "URBANE BRONZE"STO LITE EIFS PANELS: #194 STOLIT LOTUSAN LIMESTONESTO COLOR: NA 17-0034 - "HIGH REFLECTIVE WHITE"PAINT: #217 STO COLOR LOTUSANSTO COLOR: NA17-0035 - "DORIAN GRAY"PAINT: #217 STO COLOR LOTUSANSTO COLOR: NA17-0030 - "URBANE BRONZE"PAINT: #217 STO COLOR LOTUSANSHERWIN WILLIAMS 6868 "REAL RED"METAL TO BE PAINTED WITH "DIRECT TO METAL" ( DTM ) PAINTE3E4P2P3P4P1S1S2S3This drawing is an instrument of service and the property of Stewart + Reindersma Architecture, pllc, and shall remain their property. The use of this drawing shall be restricted to the original site for which it is prepared and publication thereof is expressly limited to such use.----Sake reindersmaa r c h i t e c t360DESIGN REVIEW02/02/1817-072----L IC E N SED ARCHITECTSAKE H ARM REINDERSMASTATE OF CALI F O R NIA02-02-2018 EXISTING ROOFBEYONDEXISTING WALLREVEAL0'-0"FIN. FLOOR (EXISTING) 20'-10" +/-T.O. PARAPET0'-0"FINISH FLOOR20'-8"T.O. EXISTING PARAPET25'-0"T.O. EXISTING ROOF 15'-0" T.O. EXISTING PARAPETEXISTING ROOFBEYOND0'-0"FIN. FLOOR (EXISTING) 20'-10" +/-T.O. PARAPET+/- 13'-4"B.O. EXISTINGCANOPYP1P1EXISTING ROOFBEYONDIN-FILL AREASTO BE PAINTEDIN-FILL AREASTO BE PAINTEDTRASH COMPACTORLOCATIONTRASH COMPACTORDOORP40'-0"FIN. FLOOR (EXISTING) 20'-10" +/-T.O. PARAPET+/- 13'-4"B.O. EXISTINGNEW PARAPET BEYONDCANOPY10'-0"T.O. NEWSCREENML24'-7"T.O. PARAPET0'-0"FIN. FLOOREXISTING ROOFBEYONDEXISTING WALLREVEALEXISTING WALLREVEALP1P2P3EXISTING GAS METERNEW DOOR0'-0"FIN. FLOOR (EXISTING) 20'-10" +/-T.O. PARAPETNEW EXTENDEDPARAPETREFURBISH EXISTINGCANOPY TO REMAIN39'-9"14'-0"1'-412"1'-412"P4S3S3P1NEW AUTOMATICSTOREFRONT SLIDINGDOORSP335'-0" A.F.F.T.O. PARAPET14'-0"T.O. NEW CANOPY15'-0"T.O. (E) PARAPET32'-6" A.F.F.T.O. TOWERSCALE:1EXISTING SOUTH ELEVATION3/32" = 1'-0"SCALE:2PROPOSED SOUTH ELEVATION3/32" = 1'-0"SCALE:3EXISTING WEST ELEVATION3/32" = 1'-0"SCALE:4PROPOSED WEST ELEVATION3/32" = 1'-0"a6EXTERIOR COLOR LEGEND1. WHEN THE ENTRY EIFS IS FIELD APPLIED, FINISH TO BE PAINTED WITHSTO COAT ACRYL PLUS STO COLOR NA17-0036.2. ALL STOLITE PANELS ( S1, S2, AND S3) WILL BE FABRICATED WITH THESTO COLOR ACRYLIC PLUS COATING ( PROTECTIVE COATING) ALREADYAPPLIED AND WILL EXTEND ALL THE WAY UP.GENERAL NOTES:LAST UPDATE: 12/12/2017E1E2STO COLOR: NA17-0034 - "HIGH REFLECTIVE WHITE"EIFS FINISH: #194 STOLIT LOTUSAN LIMESTONESTO COLOR: NA17-0035 - "DORIAN GRAY"EIFS FINISH: #194 STOLIT LOTUSAN LIMESTONESTO COLOR: NA17-0030 - "URBANE BRONZE"EIFS FINISH: #194 STOLIT LOTUSAN LIMESTONEEIFS SAND BLAST FINISH COLOR TO MATCH SHERWIN WILLIAMS 6868"REAL RED"STO COLOR: NA17-0034 - "HIGH REFLECTIVE WHITE"STO LITE EIFS PANELS: #194 STOLIT LOTUSAN LIMESTONESTO COLOR: NA17-0035 - "DORIAN GRAY"STO LITE EIFS PANELS: #194 STOLIT LOTUSAN LIMESTONESTO COLOR: NA17-0030 - "URBANE BRONZE"STO LITE EIFS PANELS: #194 STOLIT LOTUSAN LIMESTONESTO COLOR: NA 17-0034 - "HIGH REFLECTIVE WHITE"PAINT: #217 STO COLOR LOTUSANSTO COLOR: NA17-0035 - "DORIAN GRAY"PAINT: #217 STO COLOR LOTUSANSTO COLOR: NA17-0030 - "URBANE BRONZE"PAINT: #217 STO COLOR LOTUSANSHERWIN WILLIAMS 6868 "REAL RED"METAL TO BE PAINTED WITH "DIRECT TO METAL" ( DTM ) PAINTE3E4P2P3P4P1S1S2S3This drawing is an instrument of service and the property of Stewart + Reindersma Architecture, pllc, and shall remain their property. The use of this drawing shall be restricted to the original site for which it is prepared and publication thereof is expressly limited to such use.----Sake reindersmaa r c h i t e c t360DESIGN REVIEW02/02/1817-072----L IC E N SED ARCHITECTSAKE H ARM REINDERSMASTATE OF CALI F O R NIA02-02-2018 20'-0"20'-0"20'-0"41'-1"20'-0"20'-0"20'-0"20'-0"20'-0"20'-4"20'-0"75'-3"75'-0"75'-0"75'-3"300'-6"261'-5" 20'-0"ABCDEFGHJKL54321M180'-0"41'-1"4'-4"17'-2" 4'-6" 6'-10"44'-6"224'-8"3'-5"12'-0"25'-2"5'-0"15'-3"4'-10" 32'-9"5'-0"99'-9"19'-7"100'-4"23'-3"10'-6"65'-0 1/2"10'-6"36'-11"10'-6"51'-1"3'-4"7'-1"3'-4"10'-6"42'-3"3'-10"3'-4"24'-8 1/2"37'-7 1/2"3'-8"57'-4"3'-8"20'-8 1/2"1'-4"18'-8"1'-4"18'-8"7'-6" 51'-5 1/2"3'-8"47'-10 1/2"3'-8"38'-7"13'-11" 42'-5 1/2"3'-4"15'-4"9'-3 1/2"10'-2 1/2"7'-2"2'-9 1/2"4'-0"8'-6 1/2"fire sprinkler tobe relocated ?INFILLEXISTINGOPENINGPARTIAL DEMO @EXISTING WALL2'-9"6'-0"12'-1 1/2"13'-6"27'-7 1/2"11'-0"7'-8"11'-0"7'-8"11'-0"7'-8"11'-0"7'-8"10'-11"4'-7 1/2"PARTIAL INFILL @EXISTING OPENINGINFILLEXISTINGOPENINGPARTIAL INFILL @EXISTING OPENINGINFILLEXISTINGOPENING2'-6"1'-0"2'-0"3'-8"2'-0"1'-0"5'-8"2'-0"3'-11 1/2"1'-8 1/2"9'-3 1/2"1'-7 1/2"14'-0"NEW OPENING 414'-0"NEW OPENING 314'-0"NEW OPENING 211'-0"NEW OPENING 1PARTIAL DEMO @EXISTING WALLPARTIAL DEMO @EXISTING WALLPARTIAL DEMO @EXISTING WALL1'-0"11'-0"NEW OPENING 5DEMO. KEY NOTESG.C TO REMOVE EXISTING PARTITION FROM SLAB TOSTRUCTURE ABOVE. MAKE READY FOR NEWCONSTRUCTION - TYPICALG.C TO REMOVE EXISTING CEILING TILES, GRID, ANDLIGHTING - TYPICALG.C TO REMOVE EXISTING PLUMBING FIXTURE. CAPBOTH SUPPLY AND WASTE LINES, BELOW SLAB -TYPICALEXISTING STOREFRONT TO BE REMOVED - TYPICALEXISTING COLUMNS TO REMAIN - TYPICALEXISTING ELECTRICAL PANELS TO REMAINEXISTING FIRE RISER TO BE REMOVED AND CAPPEDBELOW GRADE.C.M.U. WALL TO BE REMOVED - TYPICALREMOVE EXISTING MILLWORK CAP ELEC. & TELE.DATA - TYPICALG.C TO REMOVE EXISTING FLOOR SLAB - TYPICAL.VERIFY IN FIELDPORTION OF WALL TO BE REMOVED FOR DOOROPENING. SEE FLOOR PLAN AND DOOR SCHEDULE.VERIFY IN FIELD AS TO NOT DAMAGE STRUCTURALCROSS BRACING IN EXISTING WALLEXISTING UTILITIES TO REMAIN - TYPICALEXISTING CONCRETE DOCK SLAB TO REMAIN.EXISTING DOCK LEVELER AND EQUIP. TO BEREMOVED.CONCRETE SLAB UNDER MEZZANINE AREA TOREMAIN.EXISTING CONCRETE WALK TO BE REMOVED, VERIFYIN FIELD TO EXTENT OF DAMAGED CONCRETE WALK.EXISTING FRAMED WALL TO BE REMOVED - CROSSBRACING, TUBE STEEL AND CMU TO REMAIN12345678910111. THE GENERAL CONTRACTOR AND HISSUB-CONTRACTORS ARE REQUIRED TO VISIT THE SITEAND BUILDING PREMISES TO INSPECT EXISTINGCONDITIONS AND BECOME FAMILIAR WITH LOCALCONDITIONS UNDER WHICH THE WORK IS TO BEPERFORMED.2. THE INTENT OF THESE DOCUMENTS IS TO INCLUDEALL ITEMS NECESSARY FOR THE PROPER EXECUTIONAND COMPLETION OF THE WORK. THE PERFORMANCEOF THE CONTRACTOR IS REQUIRED TO BE CONSISTENTWITH THE DOCUMENTS AS THE WORK IS DESCRIBED ORREASONABLY INFERRED TO PRODUCE THE REQUIREDRESULTS.3. ALL WORK SHALL BE IN STRICT COMPLIANCE WITH THECODE STANDARDS REFERENCED, EXECUTED INACCORDANCE WITH ACCEPTED INDUSTRY STANDARDSAND CONFORM TO THE SPECIFIC REQUIREMENTS OF THEOWNER AND ARCHITECT.4. THE CONTRACTOR IS RESPONSIBLE FOR ENSURINGTHE PROCUREMENT OF ALL REQUIRED PERMITS ANDAPPROVALS PRIOR TO THE COMMENCEMENT OF THEWORK AND TO PROVIDE FOR REQUIRED INSPECTIONS.ALL LICENSES, RECEIPTS FOR FEES PAID AND PERMITSSHALL BE COPIED TO THE OWNER AND THE ARCHITECTUPON RECEIPT OF SUCH.5. DO NOT SCALE DRAWINGS, USE THE DIMENSIONSPROVIDED. IF THERE ARE ANY DISCREPANCIES, CONTACTTHE OWNER OR THE ARCHITECT PRIOR TO COMMENCINGCONSTRUCTION. ALL DIMENSIONS GIVEN ARE TONOMINAL ROUGH FRAMING DIMENSIONS.6. THE GENERAL CONTRACTOR IS RESPONSIBLE FORTHE REMOVAL OF TRASH AND DEBRIS FROM THE JOBSITE ON A DAILY BASIS. THE DEBRIS REMOVED FROMTHE JOB SITE SHALL BE DISPOSED IN A LEGAL MANNER INCONFORMANCE WITH THE LOCAL, STATE AND FEDERALREGULATIONS APPLICABLE TO THE TYPE OF MATERIALSBEING REMOVED.7.FINAL CLEAN-UP IS TO INCLUDE: REMOVE DUST,DEBRIS, OILS, STAINS, PAINTS, SPILLS, FINGERPRINTS,AND LABELS FROM ALL FINISHED SURFACES.8. THE GENERAL CONTRACTOR IS RESPONSIBLE FORTHE COORDINATION OF ALL TRADES AND VENDORS(WHETHER UNDER THE GENERAL CONTRACT OROWNER/VENDOR PROVIDED) NECESSARY FOR THECOMPLETION OF THE WORK AND CERTIFICATION OF ALLWORK PRIOR TO THE OPENING DATE SPECIFIED IN THEBID FORM. THE GENERAL CONTRACTOR SHALL PROVIDEA SCHEDULE TO THE OWNER, WITHIN 3 DAYS AFTERNOTICE TO PROCEED, LISTING ALL MILESTONE TASKSAND EQUIPMENT DELIVERY DATES WITH START DATESAND COMPLETION DATES IN A LEGIBLE AND LOGICALFASHION DEMONSTRATING CONFORMANCE WITH THESCHEDULED OPENING DATE.9. THE GENERAL CONTRACTOR IS RESPONSIBLE FORSUBMITTING ANY CHANGES TO THE PERMITTED WORKTO THE PERMITTING AGENCY FOR REVISION TO THEEXISTING PERMIT. THE OWNER AND THE ARCHITECTSHALL BE COPIED WITH ALL REVISED PERMITS.10. THE GENERAL CONTRACTOR IS RESPONSIBLE FORANY DAMAGE TO OFF-SITE PROPERTY, ROADWAYS, ANDLANDSCAPING.11. AFTER DEMOLITION IS COMPLETE, THE G.C IS TOPROVIDE REDLINED AS-BUILT DIMENSIONS TO THEARCHITECT TO CHECK AGAINST THE CONSTRUCTIONDRAWINGS AND COORDINATE WITH FLOOR & DECORFIXTURE PLANS.12. ALL REMAINING FIXTURES THROUGHOUT THE SPACEARE TO BE REMOVED AND DISPOSED OF BY G.C. THISINCLUDES BUT IS NOT LIMITED TO SALES FLOORFIXTURES, STOCK ROOM RACKING, CASHWRAPS, ETC.13. G.C. TO GRADE EXISTING BUILDING PAD TO A FLATCONDITION AFTER CONCRETE SLAB IS REMOVED.14. G.C. TO REMOVE ALL GAS LINES.15. CONCRETE SLAB TO REMAIN 5'X5' AROUND THE FIRERISER AND DEMARK AREA TO REMAIN.16. G.C. TO REMOVE ALL SPRINKLER DROPS AND UNITS17. SMOKE VENTS TO REMAIN DURING DEMO PHASE18. G.C. TO REMOVE EMERGENCY LIGHTINGDEMOLITION LEGENDSTUD WALL TO BEREMOVEDWALL TO REMAINDOOR TO BE REMOVEDDOOR TO REMAINMASONRY WALL TOBE REMOVEDMASONRY WALL TOREMAINAREA OR FEATURE TO BEREMOVED1. ALL ROOFING. WORK TO BE COMPLETED BY LANDLORD(LL) APPROVED ROOFER.2. G.C. TO REMOVE ALL RTU'S AND EXHAUST FANS. G.C.TO CAP OPENINGS AS REQUIRED FOR A WATER TIGHTSEAL. (PLYWOOD AND METAL CAP)3. EXISTING BALLASTED ROOF TO REMAIN.DEMOLITION ROOFNOTES NOTES:GENERAL CONTRACTOR TO REMOVE ALL CEILINGS,CEILING GRID, CEILING TILES, LIGHT FIXTURES, HVACDIFFUSERS, SOFFITS AND SAFETY ENCLOSURES, PREPMETAL DECK AND STRUCTURE FOR NEW PAINT NOTES:GENERAL CONTRACTOR TO REMOVE ALL ABANDONEDWIRING, CONDUIT, LOW VOLTAGE SYSTEMS ANDASSOCIATED STRAPPING, CLIPS AND SUPPORTS NOTES:REMOVE ALL F.A DEVICES NOT REQUIRED TO REMAININ PLACE PER LOCAL AUTHORITY HAVINGJURISDICTION.DEMOLITION NOTES12SCALE:1DEMO FLOOR PLAN1/16" = 1'-0"5TYP.13141516AD1011718SCALE:2DEMO ENLARGED CASE OPENINGS1/16" = 1'-0"NORTH2/AD101SCALE:3DEMO FLOOR PLAN3/32" = 1'-0"3/AD1012KL11TYP.1TYP.1TYP.1TYP.2TYP.2TYP.2TYP.1TYP.3TYP.3TYP.45TYP.5TYP.5TYP.67810TYP.10TYP.5TYP.5TYP.5TYP.5TYP.5TYP.18TYP.18TYP.18TYP.This drawing is an instrument of service and the property of Stewart + Reindersma Architecture, pllc, and shall remain their property. The use of this drawing shall be restricted to the original site for which it is prepared and publication thereof is expressly limited to such use.----Sake reindersmaa r c h i t e c t360DESIGN REVIEW02/02/1817-072----L IC E N SED ARCHITECTSAKE H ARM REINDERSMASTATE OF CALI F O R NIA02-02-2018 MANATOWOCUY-0140AICE MAKERSVEND.T.C.MONITOR COFFEVENDINGMONITORU/CSAFESLOPEDOWNT.C.69,750 SQ.FT.GLAVEND.TRSH.MKR.VENDING21Lfire sprinkler tobe relocated ?This drawing is an instrument of service and the property of Stewart + Reindersma Architecture, pllc, and shall remain their property. The use of this drawing shall be restricted to the original site for which it is prepared and publication thereof is expressly limited to such use.02/06/2018L IC E N SED ARCHITECTSAKE H ARM REINDERSMASTATE OF CALI F O R NIA 5450 E. High Street, Suite 200Phoenix, Arizona 85054p: 480.515.5123www.sra360.comstewart + reindersmaA R C H I T E C T U R E , P L L C360-FIRE EXTINGUISHER(INSTALL OPPOSITE SIDE OF ENTRY ONSALES FLOOR COLUMNS)EGRESS PATHLEGEND1. PROVIDE PORTABLE FIRE EXTINGUISHERS (FE) IN ACCORDANCE WITH:A TRAVEL DISTANCE TO A FIRE EXTINGUISHER SHALL NOT EXCEED 75 FEET.B. FIRE EXTINGUISHERS Shall. NOT BE OBSTRUCTED OR OBSCURED FROM VIEW.C. FIRE EXTINGUISHERS SHALL BE CONSPICUOUSLY LOCATED WHERE THEY WILL BE READILY ACCESSIBLE AND IMMEDIATELY AVAILABLE IN THE EVENT OF A FIRE. PREFERABLY THEY SHALL BE LOCATED ALONG THE NORMAL PATHS OF TRAVEL, INCLUDING EXITS FROM AREASD. THE TOP OF THE FIRE EXTINGUISHER SHALL BEAT 42" A.F.F.E. G.C. TO COORDINATE WITH FIRE MARSHALL.F. G.C TO TO LEAVE (3) ADDITIONAL FIRE EXTINGUISHERS ON SITE FOR ALL NEW STORES.FIRE ALARM NOTES1. THIS BUILDING WILL BE EQUIPPED WITH A FIRE ALARM SYSTEM. THE FIRE ALARM SYSTEMSHALL MEET ALL REQUIREMENTS OF NFPA 72.REFER TO SPECIFICATIONS.2. SEE ELECTRICAL FOR FULL FIRE ALARM DESIGN CRITERIA.FEFIRE EXTINGUISHER NOTE1. G.C TO COORDINATE WITH ARCHITECT FOR FINAL MAP AND INSTALL IN THE BREAK ROOMAND TRAINING ROOM. MOUNT TO INSIDE FACE OF DOOR.2. THE MAP SHOULD BE INSTALLED BEFORE THE MERCHANDISE INSTALL DATE.3. PROVIDE MAPS IN OTHER LOCATIONS ONLY AS REQUIRED BY LOCAL JURISDICTION.EVACUATION MAPSCALE:EGRESS PLAN11/16 = 1'-0"EXIT-A184" CLEAR WIDTHEXIT-B34" CLEAR WIDTHEXIT-C34" CLEAR WIDTHG001CLASSIFICATION of COMMODITIES1. THE BUILDING IS CLASSIFIED AS A NON-SEPARATED, MERCANTILE OCCUPANCY.2. THE TENANT WILL STORE CLASS I-IV COMMODITIES AND GROUP A PLASTICS4. THE STORAGE CONFIGURATION WILL BE HIGH PILED STORAGE.3. NO COMMODITIES ABOVE 16'-0" AND NO PLASTICS ABOVE 5'-0".TACTILE EXIT SIGNSSEE SHEET G.002FOR DETAILSTACTILE EXIT SIGNSSEE SHEET G.002FOR DETAILSTACTILE EXIT SIGNSSEE SHEET G.002FOR DETAILSTACTILE EXIT SIGNSSEE SHEET G.002FOR DETAILSEXIT-D34" CLEAR WIDTHEXIT-E34" CLEAR WIDTHEXIT-F34" CLEAR WIDTHEXIT-G34" CLEAR WIDTH 5'-0" MAX F.F. TO TOP OF TACTILE AREA - SEE DETAIL 2E 58" MIN. 60" MAX 18" CLR. FLR.SPACE18" CLR. FLR.SPACE8"8"WOMENMENMENWOMEN58" MIN. 60" MAX 5'-0" MAX F.F. TO TOP OF TACTILE AREA - SEE DETAIL 2E 34" to 44" 34" to 44"10" KICKPLATE10" KICKPLATE48" MIN. 1'-3" 3'-2" 4'-8" 6'-8"CLCLCLCL8"NOTE: LOCATE DEVICES ON SAME WALLAS DOOR, U.O.N.DOOR FRAME EDGESTROBE (AS APPLICABLE)THERMOSTAT, INTERCOM OR SECOND ROW OFRECEPTACLES CENTER TO CLUSTER (WHENUSING DIMMERS, LOCATE THERMOSTAT ATOPPOSITE SIDE OF DOOR)LIGHT SWITCH, DIMMERS, EGRESS BUTTON,INTERCOM BUTTON, CARD READER, ETC.CLUSTER, (SEE PLAN FOR QUANTITY OF EACHCLUSTER)DOOR LEVER, PULLWALL OUTLETFINISH FLOORATYPICAL LOCATION FOR LIGHT SWITCHES,DIMMERS, EGRESS BUTTONS, THERMOSTATS, ETC.BTYPICAL LOCATION FOR POWER ANDTELEPHONE OUTLETS AT WALL OR COLUMN4'-8" 6'-8"CLCLCLCLFINISH FLOORCREDENZA OR COUNTER. REFER TOELEVATION/DETAILSLIGHT SWITCHES DIMMERS, POWER ANDTELEPHONE RECEPTACLE, ETC.THERMOSTAT OR INTERCOMSTROBE (AS APPLICABLE)6"FINISH FLOORFIRE EXTINGUISHER CABINETFIRE ALARM (SPEAKER/STROBEOR STROBE ONLY)CL42" 6'-8"CLCLCLCLCLFINISH FLOORPOWER AND TELEPHONERECEPTACLE AND CLUSTERVERTICALLY MOUNTED,CENTERED BETWEEN PANELJOINTSTYPICAL WALLPANEL JOINT1'-3" A.F.F.6"EQ.EQ.EQ.EQ.FIRE EXTINGUISHERSCALE:ACCESSIBLE GUIDELINESFNONESCALE:TACTILE SIGNSENONETACTILE SIGN NOTES:1. RAISED CHARACTERS SHALL COMPLYWITH 703.2 AND SHALL BE DUPLICATEDIN BRAILLE COMPLYING WITH 703.3.RAISED CHARACTERS SHALL BEINSTALLED IN ACCORDANCE WITH703.4. (703.2)2. BRAILLE SHALL BE CONTRACTED(GRADE 2) AND SHALL COMPLY WITH703.3 AND 703.4. (703.3)3. BRAILLE SHALL BE POSITIONED BELOWTHE CORRESPONDING TEXT. IF TEXT ISMULTI-LINED, BRAILLE SHALL BEPLACED BELOW THE ENTIRE TEXT.(703.3.2)4. PICTOGRAMS SHALL HAVE A FIELDHEIGHT OF 6 INCHES (150 MM) MINIMUM.CHARACTERS AND BRAILLE SHALL NOTBE LOCATED IN THE PICTOGRAM FIELD.(703.6.1)5. PICTOGRAMS AND THEIR FIELD SHALLHAVE A NON-GLARE FINISH.PICTOGRAMS SHALL CONTRAST WITHTHEIR FIELD WITH EITHER A LIGHTPICTOGRAM ON A DARK FIELD OR ADARK PICTOGRAM ON A LIGHT FIELD.(703.6.2)6. EXIT SIGNS COMPLYING WITH SECTION11B-703 AND IN ACCORDANCE WITHSEC. 1011.4THIS DRAWING IS A REPRESENTATIVE SUMMARY OFTHE REQUIREMENTS OF THE ADA STANDARDSTHAT MAY BE APPLICABLE TO THE PROJECT.WHERE SPECIFIC DIMENSIONAL INFORMATION ANDCLEARANCES ARE NOT NOTED ON THE DRAWINGS,CONSTRUCT TO THE CLEARANCES ANDTOLERANCES SHOWN ON THIS SHEET. WHEREDRAWINGS SPECIFICALLY INDICATE DIFFERENT ORCONFLICTING INFORMATION TO THE STANDARDSDEPICTED ON THIS SHEET, CONSTRUCT USING THEMORE STRINGENT REQUIREMENT OR CONTACT THEARCHITECT FOR RESOLUTIONBOT OF BRAILLETOP OF CHARACTEREXITEXIT ROUTE5'-0"(A) CIRCULAR TURNING SPACE(B) T-SHAPED TURNING SPACE5'-0"3'-0" 5'-0"3'-0"2'-0"1'-0"1'-0"DOOR SWING:UNLESS OTHERWISE SPECIFIED, DOORS SHALL BE PERMITTED TOSWING INTO TURNING SPACES.SIZE OF TURNING SPACE:THE MINIMUM SPACE REQUIRED FOR A STANDARD WHEELCHAIR TO MAKE A180-DEGREE TURN IS A CLEAR SPACE OF A 60 INCH DIAMETER OR A T-SHAPEDSPACE. REFER TO THE TURNING SPACE DETAILS BELOW.FRONT APPROACH,PUSH SIDE48"MIN.LATCH APPROACH,PULL SIDE,CLOSERAND LATCH24" MIN.54"MIN.32" MIN. CLR. 32" MIN. CLR.1'-0"2'-4"1'-0"2'-4"4'-6"1'-6"3'-10" 1'-6"3'-10" 1'-6"1'-5" 1'-6"1'-5"1'-6"1'-5" 1'-6"1'-5"6"3'-0"6"3'-0"5'-10 1/2"36" MIN DOOR CLR.5'-11"36" MIN DOOR CLR.5'-0"5'-4"5'-0"3'-6"3'-6"3'-0"6" 5'-2"Push Side6aPull Side6b15" MIN.48" MAXFIGURE 11B-308.2.1 UNOBSTRUCTED FORWARDREACH48" MAX 20" MAXFIGURE 11B-308.2.2 UNOBSTRUCTED HIGHFORWARD REACHA48" MAX 20"-25"MAXBFIGURE 11B-308.3.1 UNOBSTRUCTED SIDEREACH15" MIN.48" MAX10"MAXFIGURE 11B-308.3.2 UNOBSTRUCTED SIDEREACH48" MAX10-24MAXFIGURE 11B-308.3.2 UNOBSTRUCTED SIDEREACH34" MAX 48" MAX10"MAX34" MAX 1'-4 1/2" 1'-10 1/2"2'-11"1'-5 1/2"1'-5 1/2"42" MAX T.O. BUBBLER 36" MAX T.O. BUBBLER 3'-6"3 1/2"1'-3"6"7"2'-6" 2'-9"8"4'-0"ADA HI-LOW DRINKINGFOUNTAIN4X4 FRP PANEL BEIGECANE APRON FOR HAC(PLATINUM VINYL)ADAADA4X4 FRP PANELBEIGE1'-10 1/2" 1'-4 1/2"SCALE:ADA - HI-LO DRINKING FOUNTAIN81/2" = 1'-0"NOTE:FIXTURE SHOWN FOR ILLUSTRATIONPURPOSE ONLY. SEE SHEET A502 ANDPLUMBING FOR ACTUAL FIXTURE TYPE.34" MAX 48" MAX NOTE:DASHED LINES INDICATES DIMENSIONALUNDER LAVATORY ENCLOSURE.KNEE CLEARANCE34" MAX 27" MIN.8"MIN9" MIN11"6"17" MIN.17"-18"12"MIN.39" - 41" 33"-36"18"CLEARFLOORSPACE48"MIN.25" MAX.24" MIN.18" MIN. 39"-41" 33"-36" 19 " MIN.7-9"42" MIN.12"MAX39"-41"54" MINTOP OFGRIPPINGSURFACE40" MAX. B.O. MIRROR REFLECTIVE SURFACE 18"MIN.39"-41" 33"-36" 1'-3" MIN. 17-19"7-9"39"-41"1 3/8" MIN24" MIN.30" MIN.36" MIN.12"MAX.54" MIN.42"MIN.TOILET PAPERDISPENSER(BELOW GRABBAR)TOILET PAPERDISPENSER(BELOW GRABBAR)INSULATE DRAIN ANDHOT WATER LINESBELOW LAVATORHAND DRYER36"x24" MIRRORGSIDE ELEVATION AT DRINKING FOUNTAINDFRONT ELEVATION AT WATER CLOSETHPLAN AT DRINKING FOUNTAINFORWARD APPROACHHPLAN AT DRINKING FOUNTAINSIDE APPROACHAPLAN AT LAVATORYBSIDE ELEVATION AT LAVATORYCFRONT ELEVATION AT LAVATORY40" MAX. B.O. MIRROR REFLECTIVE SURFACE CLEARFLOORSPACECLEARFLOORSPACE36" MAX 27"MIN 8"MIN.9" MIN11"MIN6"17-25"MAX KNEE CLR.15"MIN5"MAX48" MIN.30"MIN.3 1/2'MAXESIDE ELEVATION AT WATER CLOSETOPPOSITE SIDE VIEWFSIDE ELEVATION AT WATER CLOSET48"MIN.MAX. TOE CLR.30" MIN.SCALE:3TYPICAL PLUMBING ELEMENTS AND FACILITIESN.T.S.1/4"(MAX.)(A) VERTICAL CHANGEIN LEVEL1/4"(MAX.)(B) BEVELED CHANGEIN LEVEL121/2"(MAX.)SCALE:4TYP. TRANSITION DETAILN.T.S.VERTICAL CHANGES IN LEVEL:CHANGES IN LEVEL GREATER THAN 1/4 INCH (6.4MM) IN HEIGHT AND NOT MORE THAN 1/2 INCH(13MM) MAXIMUM IN HEIGHT SHALL BE BEVELEDWITH A SLOPE NOT STEEPER THAN 1:2.TYPICAL TACTILE SIGNAGESCALE: N.T.S.1TYPICAL MOUNTING HEIGHTSSCALE: N.T.S.2G.C. TO PROVIDE RESTROOM SIGN WITH RAISED AND BRAILLE CHARACTERS AND PICTORIAL SYMBOL SIGN AT CORRIDOR SIDE OF TOILET ROOM DOORAS PER STATE AND LOCAL ACCESSIBILITY CODE.A. BOTTOM OF TACTILE CHARACTERS SHALL BE MOUNTED BETWEEN 48" AND 60" A.F.F.B. BOTTOM OF BRAILLE SHALL BE MOUNTED BETWEEN 68" A.F.F.C. SIGN TO BE SURFACE MOUNTED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR.D. SIGNS SHALL BE IN CONTRASTING COLOR AND NON-GLARE FINISH.CTYPICAL LOCATION FOR OUTLETS, SWITCHES ANDTHERMOSTATS, ETC. AT CREDENZA OR COUNTERTOPDTYPICAL LOCATION FOR ONE OR TWO MOUNTEDFIRE ALARM DEVICES / VISUAL ALARM FECGRAB BAR NOTES:1. BENDING STRESS IN GRAB BAR OR SEAT INDUCED BY THEMAXIMUM BENDING MOMENT FROM THE APPLICATION OF 250LBF SHALL BE LESS THAN THE ALLOWABLE STRESS FOR THEMATERIAL OF THE GRAB BAR OR SEAT.2. SHEAR STRESS INDUCED IN A GRAB BAR OR SEAT BY THEAPPLICATION OF 250LBF SHALL BE LESS THAN THE ALLOWABLESHEAR STRESS FOR THE MATERIAL OF THE GRAB BAR OR SEAT.IF THE CONNECTION BETWEEN THE GRAB BAR OR SEAT AND IT'SMOUNTING BRACKET OR OTHER SUPPORT IS CONSIDERED TOBE FULLY RESTRAINED, THEN DIRECT AND TORSIONAL SHEARSTRESSES SHALL BE TOTALED FOR THE COMBINED SHEARSTRESS, WHICH SHALL NOT EXCEED THE ALLOWABLE SHEARSTRESS.5/8" GYP. BD.FRT WOOD BLOCKING(TYP.)1 1/2" MIN. AND MAX..1 1/4" TO 1 1/2"NOMINALDIAMETER.3. SHEAR FORCE INDUCED IN A FASTENER OR MOUNTING DEVICEFROM THE APPLICATION OF 250 LBF SHALL BE LESS THAN THEALLOWABLE LATERAL LOAD OF EITHER THE FASTENER ORMOUNTING DEVICE OR THE SUPPORTING STRUCTURE,WHATEVER IS THE SMALLER ALLOWABLE LOAD.4. TENSILE FORCE INDUCED IN A FASTENER BY A DIRECT TENSIONFORCE OF 250 LBF PLUS THE MAX. MOMENT FROM THEAPPLICATION OF 250 LBF. SHALL BE LESS THAN THE ALLOWABLEWITHDRAWAL LOAD BETWEEN THE FASTENER AND THESUPPORTING STRUCTURE.ARCHITECTURAL SYMBOL LEGENDNUMBERPARTITION TAGDETAIL TAGSECTION TAGELEVATION TAGFINISH TAGNEW DOOREXISTING DOOR - SEEDOOR SCHEDULE FORNEW WORKAREADETAILEDPLAN DETAILLEASE LINEREVISIONNUMBERWINDOW MARKERNOTE ARROWLEVEL DATUMKEYED NOTECOLCENTERLINEDOORDESIGNATIONNUMBERCOLUMN DESIGNATIONX ##FLOORROOM NUMBERROOM DESIGNATIONSYMBOLDESCRIPTIONACCESSIBILITY GUIDELINESXX-X#TYPICAL ACCESSIBILITY CLEARANCES SCALE: N.T.S.6SCALE: N.T.S.7TYPICAL ACCESSIBILITY REACH CLEARANCES AXG002SCALE:TYPICAL GRAB BAR DETAIL51/16" = 1'-0"TYPICAL ABBREVIATIONSBM.ACCOUSTICAL CEILING TILEA.C.T.A.D.A.A.F.F.BD.CLG.CLR.CONC.EQ.F.C.FIN.F&IFL.F.F.F.S.F.V.F.C.I.C.F.O.I.O.F.O.I.C.F.L.I.L.G.A.G.C.LL.AMERICANS WITH DISABILITIES ACTABOVE FINISH FLOORBOARDBEAMCEILINGCLEARCONCRETEEQUALFIXTURE CONTRACTORFINISHFURNISH AND INSTALLFLOORFACE OF FINISHPLASTIC LAMINATEFACE OF STUDFIELD VERIFYFURNISHED BY CONTRACTOR, INSTALLED BY CONTRACTOR (G.C.)GAUGEGENERAL CONTRACTORLANDLORDMINIMUMFURNISHED BY OWNER, INSTALLED BY CONTRACTOR (G.C.)METALON CENTERREFLECTEDSTAINLESS STEELSTEELSTRUCTURESIMILARSUSPENDEDFURNISHED BY OWNER, INSTALLED BY OWNERFURNISHED BY LANDLORD, INSTALLED BY LANDLORDTO BE DETERMINEDO.C.TEMPORARYP.L.TONGUE AND GROOVETYPICALSTL.UNLESS NOTED OTHERWISEVERIFY IN FIELDSUSP.VINYL COMPOSITION TILET.B.D.WITHWOODMIN.T&GMTL.TYP.U.N.O.V.I.F.REFL.SST.WD.STRUCT.SIM.H.M.GYPSUM WALL BOARDTEMP.GYPSUM WALL BOARDV.C.T.W/G.W.B.GYP.BD.HOLLOW METALDOWNSPOUTRDTAHOSE BIBMILLWORK CONTRACTORROOF WATER LEADERM.W.C.R.W.L.FIRE RATED TREATEDF.R.T.U.L.UNDERWRITER'S LABORATORYAMERICAN SOCIETY FOR TESTING AND MATERIALSA.S.T.M.WATER CLOSETWCABOVEABVDSDFDRINK FOUNTAINREFRIGERATORREFROUND?MICROWAVEMICROHB1. AN UNOBSTRUCTED TURNING SPACE OF 60" IN DIAMETER SHALL BE PROVIDED WITHIN AN ACCESSIBLE TOILET ROOM.2. 11B-604.2 LOCATION. THE WATER CLOSET SHALL BE POSITIONED WITH A WALL OR PARTITION TO THE REAR AND TO ONE SIDE. THE CENTERLINE OF THE WATER CLOSET SHALLBE 17 INCHES (432 MM) MINIMUM TO 18 INCHES (457 MM) MAXIMUM FROM THE SIDE WALL OR PARTITION, EXCEPT THAT THE WATER CLOSET SHALL BE 17 INCHES (432 MM)MINIMUM AND 19 INCHES (483 MM) MAXIMUM FROM THE SIDE WALL OR PARTITION IN THE AMBULATORY ACCESSIBLE TOILET COMPARTMENT SPECIFIED IN SECTION 11B-604.8.2.WATER CLOSETS SHALL BE ARRANGED FOR A LEFT-HAND OR RIGHT-HAND APPROACH.11B-604.3.1 SIZE. CLEARANCE AROUND A WATER CLOSET SHALL BE 60 INCHES (1524 MM) MINIMUM MEASURED PERPENDICULAR FROM THE SIDE WALL AND 56 INCHES (1422 MM)MINIMUM MEASURED PERPENDICULAR FROM THE REAR WALL. A MINIMUM 60 INCHES (1524 MM) WIDE AND 48 INCHES (1219 MM) DEEP MANEUVERING SPACE SHALL BEPROVIDED IN FRONT OF THE WATER CLOSET.11B-604.3.2 OVERLAP. THE REQUIRED CLEARANCE AROUND THE WATER CLOSET SHALL BE PERMITTED TO OVERLAP THE WATER CLOSET, ASSOCIATED GRAB BARS,DISPENSERS, SANITARY NAPKIN DISPOSAL UNITS, COAT HOOKS, SHELVES, ACCESSIBLE ROUTES, CLEAR FLOOR SPACE AND CLEARANCES REQUIRED AT OTHER FIXTURES,AND THE TURNING SPACE. NO OTHER FIXTURES OR OBSTRUCTIONS SHALL BE LOCATED WITHIN THE REQUIRED WATER CLOSET CLEARANCE.11B-604.8.1.1 SIZE. WHEELCHAIR ACCESSIBLE COMPARTMENTS SHALL BE 60 INCHES (1524 MM) WIDE MINIMUM MEASURED PERPENDICULAR TO THE SIDE WALL, AND 56 INCHES(1422 MM) DEEP MINIMUM FOR WALL HUNG WATER CLOSETS AND 59 INCHES (1499 MM) DEEP MINIMUM FOR FLOOR MOUNTED WATER CLOSETS MEASURED PERPENDICULAR TOTHE REAR WALL. WHEELCHAIR ACCESSIBLE COMPARTMENTS SHALL ADDITIONALLY PROVIDE MANEUVERING SPACE COMPLYING WITH SECTION 11B-604.8.1.1.1, 11B-604.8.1.1.2,OR 11B- 604.8.1.1.3, AS APPLICABLE. WHEELCHAIR ACCESSIBLE COMPARTMENTS FOR CHILDREN’S USE SHALL BE 60 INCHES (1524 WIDE MINIMUM MEASURED PERPENDICULARTO THE SIDE WALL, AND 59 INCHES (1499 MM) DEEP MINIMUM FOR WALL HUNG AND FLOOR MOUNTED WATER CLOSETS MEASURED PERPENDICULAR TO THE REAR WALL.11B-604.8.1.1.1 MANEUVERING SPACE WITH IN-SWINGING IN A WHEELCHAIR ACCESSIBLE COMPARTMENT WITH AN IN-SWINGING DOOR, A MINIMUM 60 INCHES (1524 MM) WIDE BY36 INCHES (914 MM) DEEP MANEUVERING SPACE SHALL BE PROVIDED IN FRONT OF THE CLEARANCE REQUIRED IN SECTION 11B-604.8.1.1. SEE FIGURES 11B-604.8.1.1.2 (B) AND11B-604.8.1.1.3 (B).11B-604.8.1.1.2 MANEUVERING SPACE WITH SIDE-OPENINGN IN A WHEELCHAIR ACCESSIBLE COMPARTMENT WITH A DOOR LOCATED IN THE SIDE WALL OR PARTITION, EITHERIN-SWINGING OR OUT-SWINGING, A MINIMUM 60 INCHES (1524 MM) WIDE AND 60 INCHES (1524 MM) DEEP MANEUVERING SPACE SHALL BE PROVIDED IN FRONT OF THE WATERCLOSET. SEE FIGURE 11B-604.8.1.1.2.11B-604.8.1.1.3 MANEUVERING SPACE WITH ENDOPENING IN A WHEELCHAIR ACCESSIBLE COMPARTMENT WITH A DOOR LOCATED IN THE FRONT WALL OR PARTITION (FACINGTHE WATER CLOSET), EITHER IN-SWINGING OR OUT-SWINGING, A MINIMUM 60 INCHES (1524 MM) WIDE AND 48 INCHES (1219 MM) DEEP MANEUVERING SPACE SHALL BE PROVIDEDIN FRONT OF THE WATER CLOSET. SEE FIGURE 11B-604.8.1.1.3.3. GRAB BARS AT EACH SIDE OR ONE SIDE AND THE BACK OF THE WATER CLOSET SHALL BE PROVIDED AND SECURELY ATTACHED:a. 33" MIN TO 36" MAX TO THE TOP OF THE GRIPPING SURFACE ABOVE AND PARALLEL TO THE FLOOR.b.GRAB BARS AT THE SIDE SHALL BE 42" LONG ANS SHALL BE POSITIONED SUCH THAT THE CENTER OF ONE ESCUTCHEON PLATE IS NOT MORE THAN 12" AWAY FROM THEREAR WALL AND THE OTHER END IS AT LEAST 24" IN FRONT OF THE WATER CLOSETc.THE REAR GRAB BAR OF THE WATER CLOSET SHALL BE MIN. 36" LONG AND SHALL BE POSITIONED SO THAT THE END CLOSEST TO THE NEAREST SIDE WALL IS AT LEAST 12"FROM THE CENTERLINE OF TGHE WATER CLOSET TO THE CENTER OF THE ESCUTCHEON PLATE, AND THE OTHER END IS AT LEAST 24" FRPM THE CENTERLINE OF THEWATER CLOSET TO THE CENTER OF THE ESCUTCHEON PLATE.4. 11B-609.2.1 CIRCULAR CROSS SECTION. GRAB BARS WITH CIRCULAR CROSS SECTIONS SHALL HAVE AN OUTSIDE DIAMETER OF 1-1/4 INCHES (32 MM) MINIMUM AND 2 INCHES (51MM) MAXIMUM11B-609.2.2 NON-CIRCULAR CROSS SECTION. GRAB BARS WITH NON-CIRCULAR CROSS SECTIONS SHALL HAVE A CROSS-SECTION DIMENSION OF 2INCHES (51 MM) MAXIMUM AND A PERIMETER DIMENSION OF 4 INCHES (102 MM) MINIMUM AND 4.8 INCHES (122 MM) MAXIMUM.5. 11B-606.3 HEIGHT. LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE FRONT OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES (864 MM) MAXIMUM ABOVETHE FINISH FLOOR OR GROUND.1B-606.4 FAUCETS. CONTROLS FOR FAUCETS SHALL COMPLY WITH SECTION 11B-309. HAND-OPERATED METERING FAUCETS SHALL REMAIN OPEN FOR 10 SECONDS MINIMUMAND SHALL DELIVER MORE THAN 0.20 GALLONS PER CYCLE.11B-606.5 EXPOSED PIPES AND SURFACES. WATER SUPPLY AND DRAIN PIPES UNDER LAVATORIES AND SINKS SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECTAGAINST CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES AND SINKS.11B-606.6 ADJACENT SIDE WALL OR PARTITION. LAVATORIES, WHEN LOCATED ADJACENT TO A SIDE WALL OR PARTITION, SHALL BE A MINIMUM OF 18 INCHES (457 MM) TO THECENTERLINE OF THE FIXTURE.THE REQUIRED KNEE SPACE (NEGLECTING THE DIP OF THE OVERFLOW) SHALL BE SHOWN A MIN. OF 29" AFF AT THE FRONT EDGE OF THE COUNTER OR LAVATORY FIXTURE(WHICHEVER PROTRUDES MORE), DECREASING TO 27" AFF AT 8" MIN FROM THE FRONT EDGE ABD DECREASING AGAIN TO 9" AFF AT A MIN. OF 11"11B-306.2.3 MINIMUM REQUIRED DEPTH. WHERE TOE CLEARANCE IS REQUIRED AT AN ELEMENT AS PART OF A CLEAR FLOOR SPACE, THE TOE CLEARANCE SHALL EXTEND 17INCHES (432 MM) MINIMUM UNDER THE ELEMENT. EXCEPTION: TOE CLEARANCE SHALL EXTEND 19 INCHES (483 MAXIMUM) UNDER LAVATORIES REQUIRED TO BE ACCESSIBLEBY SECTION 11B-213.3.4.11B-305.1 GENERAL. CLEAR FLOOR OR GROUND SPACE SHALL COMPLY WITH SECTION 11B-305.11B-305.2 FLOOR OR GROUND SURFACES. FLOOR OR GROUND SURFACES OF A CLEAR FLOOR OR GROUND SPACE SHALL COMPLY WITH SECTION11B-302. CHANGES IN LEVELARE NOT PERMITTED. EXCEPTION: SLOPES NOT STEEPER THAN 1:48 SHALL BE PERMITTED.11B-305.3 SIZE. THE CLEAR FLOOR OR GROUND SPACE SHALL BE 30 INCHES (762 MM) MINIMUM BY 48 INCHES (1219 MM) MINIMUM.11B-305.4 KNEE AND TOE CLEARANCE. UNLESS OTHERWISE SPECIFIED, CLEAR FLOOR OR GROUND SPACE SHALL BE PERMITTED TO INCLUDE KNEE AND TOE CLEARANCECOMPLYING WITH SECTION 11B-306.11B-305.5 POSITION. UNLESS OTHERWISE SPECIFIED, CLEAR FLOOR OR GROUND SPACE SHALL BE POSITIONED FOR EITHER FORWARD OR PARALLEL APPROACH TO ANELEMENT.11B-305.6 APPROACH. ONE FULL UNOBSTRUCTED SIDE OF THE CLEAR FLOOR OR GROUND SPACE SHALL ADJOIN AN ACCESSIBLE ROUTE OR ADJOIN ANOTHER CLEAR FLOOROR GROUND SPACE. CLEAR FLOOR OR GROUND SPACE MAY OVERLAP AN ACCESSIBLE ROUTE, UNLESS SPECIFICALLY PROHIBITED ELSEWHERE IN THIS CHAPTER.11B-305.7 MANEUVERING CLEARANCE. WHERE A CLEAR FLOOR OR GROUND SPACE IS LOCATED IN AN ALCOVE OR OTHERWISE CONFINED ON ALL OR PART OF THREE SIDES,ADDITIONAL MANEUVERING CLEARANCE SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS 11B-305.7.1 AND 11B-305.7.2.1B-309 WHERE APPLICABLE, HAND OPERATED METERING FAUCETS SHALL REMAIN OPEN FOR 10 SECONDS MINIMUM ANS SHALL DELIVER MORE THAN .20 GALLONS PER CYCLE.11B-305.7.1 FORWARD APPROACH. ALCOVES SHALL BE 36 INCHES (914 MM) WIDE MINIMUM WHERE THE DEPTH EXCEEDS 24 INCHES (610 MM).11B-305.7.2 PARALLEL APPROACH. ALCOVES SHALL BE 60 INCHES (1524 MM) WIDE MINIMUM WHERE THE DEPTH EXCEEDS 15 INCHES (381 MM).11B-602.3 OPERABLE PARTS. OPERABLE PARTS SHALL COMPLY WITH SECTION 11B-309. THE FLOW OF WATER SHALL BE ACTIVATED BY A MANUALLY OPERATED SYSTEM THAT ISFRONT MOUNTED OR SIDE MOUNTED AND LOCATED WITHIN 6 INCHES (152 MM) OF THE FRONT EDGE OF THE FOUNTAIN OR AN AUTOMATIC ELECTRONICALLY CONTROLLEDDEVICE.11B-602.4 SPOUT HEIGHT. SPOUT OUTLETS SHALL BE 36 INCHES (914 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.11B-602.5 SPOUT LOCATION. THE SPOUT SHALL BE LOCATED 15 INCHES (381 MM) MINIMUM FROM THE VERTICAL SUPPORT AND 5 INCHES (127 MM) MAXIMUM FROM THE FRONTEDGE OF THE UNIT, INCLUDING BUMPERS.11B-602.6 WATER FLOW. THE SPOUT SHALL PROVIDE A FLOW OF WATER 4 INCHES (102 MM) HIGH MINIMUM AND SHALL BE LOCATED 5 INCHES (127 MM) MAXIMUM FROM THEFRONT OF THE UNIT. THE ANGLE OF THE WATER STREAM SHALL BE MEASURED HORIZONTALLY RELATIVE TO THE FRONT FACE OF THE UNIT. WHERE SPOUTS ARE LOCATEDLESS THAN 3 INCHES (76 MM) OF THE FRONT OF THE UNIT, THE ANGLE OF THEWATER STREAM SHALL BE 30 DEGREES MAXIMUM. WHERE SPOUTS ARE LOCATED BETWEEN 3INCHES (76 MM) AND 5 INCHES (127 MM) MAXIMUM FROM THE FRONT OF THE UNIT, THE ANGLE OF THE WATER STREAM SHALL BE 15 DEGREES MAXIMUM.11B-602.7 DRINKING FOUNTAINS FOR STANDING PERSONS. SPOUT OUTLETS OF DRINKING FOUNTAINS FOR STANDING PERSONS SHALL BE 38 INCHES (965 MM) MINIMUM AND 43INCHES (1092 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.11B-602.8 DEPTH. WALL- AND POST-MOUNTED CANTILEVERED DRINKING FOUNTAINS SHALL BE 18 INCHES (457 MM) MINIMUM AND 19 INCHES (483 MM) MAXIMUM IN DEPTH.11B-602.9 PEDESTRIAN PROTECTION. ALL DRINKING FOUNTAINS SHALL EITHER BE LOCATED COMPLETELY WITHIN ALCOVES, POSITIONED COMPLETELY BETWEEN WING WALLS,OR OTHERWISE POSITIONED SO AS NOT TO ENCROACH INTO PEDESTRIAN WAYS. THE PROTECTED AREAWITHIN WHICH A DRINKING FOUNTAIN IS LOCATED SHALL BE 32INCHES (813 MM) WIDE MINIMUM AND 18 INCHES (457 MM) DEEP MINIMUM, AND SHALL COMPLY WITH SECTION 11B-305.7. WHEN USED, WING WALLS OR BARRIERS SHALLPROJECT HORIZONTALLY AT LEAST AS FAR AS THE DRINKING FOUNTAIN AND TO WITHIN 6 INCHES (152 MM) VERTICALLY FROM THE FLOOR OR GROUND SURFACE.6. A CLEAR FLOOR SPACE OF NOT LESS THAN 30" WIDE AND 48" LONG SHALL BE PROVIDED AT EACH WATER COOLER FOR THE USE OF THE DISABLED. THE WATER COOLER UNITSHALL HAVE A KNEE CLEARANCE THAT IS AT LEAST 27" HIGH AND 17"-19" DEEP. SPOUTS SHALL BE NO HIGHER THAN 36" ABOVE FINISH FLOOR TO THE SPOUT OUTLET.7. WHERE MIRRORS ARE PROVIDED, AT LEAST ONE SHALL BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING SURFACE NO HIGHER THAN 40" ABOVE THE FINISHEDFLOOR.8. WHERE PAPER TOWEL DISPENSERS AND DISPOSAL FIXTURES ARE PROVIDED, AT LEAST ONE SHALL BE INSTALLED WITH THE OPERABLE PARTS OF THE DISPENSERS ATMAXIMUM OF 40" ABOVE THE FINISH FLOOR.9. WHERE TOILET PAPER DISPENSERS ARE PROVIDED, AT LEAST ONE SHALL BE INSTALLED WITHIN REACH, UNDER THE GRAB BAR PER 11B-604.7, AND 19" MAXIMUM AFF TOWHERE THE TISSUES DISPENSES.10. CONTROLS AND SWITCHES ON WALLS ARE TO BE PLACED A MAXIMUM OF 48" ABOVE THE FINISH FLOOR. ELECTRICAL RECEPTACLES ON WALLS SHALL BE PLACED NO LESSTHAN 15" ABOVE THE FINISH FLOOR. DIMENSIONS ARE TO THE HIGHEST OPERABLE PART OF CONTROLS AND THE LOWEST OPERABLE PART OF CONTROLS AND THE LOWESTOPERABLE PART OF RECEPTACLES.11. AT EXITS SERVING A REQUIRED ACCESSIBLE SPACE, BUT NOT PROVIDING AN APPROVED ACCESSIBLE MEANS OF EGRESS SHALL HAVE A DIRECTIONAL SIGN COMPLYING WITHTHE VISUAL CHARCTER PROVISIONS OF 11B-703.5 THAT INDICATES THE LOCATION OF OTHER MEANS OF EGRESS AND WHICH OF THOSE ARE ACCESSIBLE MEANS OF EGRESS.X+XX'-X"#1/Axxx1/Axxx1/AxxxThis drawing is an instrument of service and the property of Stewart + Reindersma Architecture, pllc, and shall remain their property. The use of this drawing shall be restricted to the original site for which it is prepared and publication thereof is expressly limited to such use.----Sake reindersmaa r c h i t e c t360DESIGN REVIEW02/02/1817-072----L IC E N SED ARCHITECTSAKE H ARM REINDERSMASTATE OF CALI F O R NIA02-02-2018 P3123P1P2P3P4EXISTING ROOFBEYONDP4S3NEW SIGNAGELOCATION45S3P413'-4"B.O. CANOPYP1P3NEW PILASTEREXISTING WINDOWSYSTEM TO REMAINNEW PILASTERS3S3S2S1P1NEW EXTENDEDPARAPET0'-0"FIN. FLOOR35'-0"T.O. TOWER A.F.F.32'-6"T.O. PILASTER20'-8"T.O. PARAPETNEW CANOPYNEW EXTENDEDPARAPET BEYONDNEW EXTENDEDPARAPETP1P414'-0"T.O. NEW CANOPY14'-0" EXISTING DECK HEIGHT NEW CANOPY(MATCH EXISTINGCANOPY)P2CEGJKMBDFHL0'-0"FIN. FLOOR20'-7"T.O. PARAPETEXISTING ROOFBEYONDNEW PILASTEREXISTING WALLREVEALNEW ROLLUP DOORP2P4EXISTING BOLLARDSAND FIRE RISERPIPESP4P4EXISTINGLIGHTING, TYP.P1P1P2P3PARAPET WALLLBEYOND16'-6"T.O. PILASTER13'-4"+/-B.O. EXISTINGP1P3P2P3S3S3S2S1P4P1P2NEW AUTOMATICDOOR SLIDERNEW LOADING DOCKSWITH NEW ROLL-UPDOORSEXISTINGCANOPYTO REMAINNEW CANOPYCANOPY24'-8"T.O. PARAPETTRASH COMPACTORLOCATION (BEYOND)NEW SAFETYRAILS AND RAMPP410'-0"T.O. SCREEN WALLNEW PILASTER12345P1P1EXISTING ROOFBEYONDIN-FILL AREASTO BE PAINTEDIN-FILL AREASTO BE PAINTEDTRASH COMPACTORLOCATIONTRASH COMPACTORDOORP40'-0"FIN. FLOOR (EXISTING) 20'-10" +/-T.O. PARAPET+/- 13'-4"B.O. EXISTINGNEW PARAPET BEYONDCANOPY10'-0"T.O. NEWSCREENCEJKMBDFHAL24'-7"T.O. PARAPET0'-0"FIN. FLOOREXISTING ROOFBEYONDEXISTING WALLREVEALEXISTING WALLREVEALP1P2P3EXISTING GAS METERNEW DOOR0'-0"FIN. FLOOR (EXISTING) 20'-10" +/-T.O. PARAPETNEW EXTENDEDPARAPETREFURBISH EXISTINGCANOPY TO REMAINP4S3S3P1NEW AUTOMATICSTOREFRONT SLIDINGDOORSP335'-0" A.F.F.T.O. TOWERG14'-0"T.O. NEW CANOPY(MATCH EXISTINGCANOPY)SCALE:1NORTH ELEVATION (FOR REFERENCE ONLY)3/32" = 1'-0"SCALE:4SOUTH ELEVATION (FOR REFERENCE ONLY)3/32" = 1'-0"SCALE:2EAST ELEVATION (FOR REFERENCE ONLY)3/32" = 1'-0"SCALE:3WEST ELEVATION (FOR REFERENCE ONLY)3/32" = 1'-0"This drawing is an instrument of service and the property of Stewart + Reindersma Architecture, pllc, and shall remain their property. The use of this drawing shall be restricted to the original site for which it is prepared and publication thereof is expressly limited to such use.02/06/2018L IC E N SED ARCHITECTSAKE H ARM REINDERSMASTATE OF CALI F O R NIA 5450 E. High Street, Suite 200Phoenix, Arizona 85054p: 480.515.5123www.sra360.comstewart + reindersmaA R C H I T E C T U R E , P L L C3601/A3031/A302A301Existing Elevations SF: North Elev. 6,505 SF New Elev - modifications: Front Canopy 1,657 SF Pillasters: 460 SF Extended Parapet: 656 Ex. Entry Doors (infill): 84 SF Total Mod: 2,857 SF 2857/6505 = 44%Existing Elevations SF: East Elev. 4,903 SF New Elev - modifications: CUPU Canopy: 845 SF Loading Dock: 944 SF Trash Compactor Wall: 55 Pillasters: 67 SF Total Mod: 1,911 SF 1911/4903 = 39%Existing Elevations SF: West Elev. 5,165 SF New Elev - modifications: Entry Canopy: 1,050 SF Tower Element Side: 477 SF Building removed: 720 SF Pillasters: 0 SF Total Mod: 2,247 SF 2247/5165 = 43%Existing Elevations SF: South Elev. 6,531 SF New Elev - modifications: Trash compator wall: 501 SF Infill Roll-up Doors: 516 SF Pillasters: 0 SF Total Mod: 1,017 SF 1017/6531 = 16%TOTAL AGGREGATE Existing Elevations SF: NEWS Elev. 23,104 SF New Elev - modifications: Total Mod: 8,032 SF 8032/23104 = 35%Existing Window system to be replaced, match existing Community Development Department PLANNING COMMISSION STAFF REPORT PROPOSED ACQUISITION OF PROPERTY LOCATED AT 858-860 HINCKLEY ROAD BY THE SAN MATEO UNION HIGH SCHOOL DISTRICT (SMUSHD) FOR CONSTRUCTION OF A NEW CONTINUATION HIGH SCHOOL/ALTERNATIVE HIGH SCHOOL Meeting Date: April 9, 2018 REGULAR ACTION Item No: 8(d) 1 PROPERTY ADDRESS: 858-860 Hinckley Road, Burlingame, California APN: 026-310-480 APPLICANT: San Mateo Union High School District (SMUSHD) PROPERTY OWNER: Hinckley Properties LLC GENERAL PLAN/ZONING: Inner Bayshore (IB) LOT AREA: 0.99-Acre (Approximate) BACKGROUND Pursuant to Public Resources Code Section 21151.2, the San Mateo Union High School District (SMUHSD) has provided notice to the City of Burlingame Planning Commission of its intent to acquire the property located at 858 & 860 Hinckley Road in Burlingame. SMUHSD intends to acquire the property to construct a new continuation high school/alternative high school to replace Peninsula High School, which is currently located at 300 Piedmont Avenue in San Bruno. If the property is ac quired, the District plans to demolish the existing improvements on the property to accommodate construction of the new facility. The Commission is provided a maximum of 30-days to provide its position regarding the potential purchase; by April 20, 2018. Irrespective of the Planning Commission’s position regarding the purchase, the SMUHSD Board may still choose to purchase the property. State statute provides that “the governing board shall not acquire title to the property until the report of the planning commission has been received. If the report does not favor the acquisition of the property for a school site, or for an addition to a present school site, the governing board of the school district shall not acquire title to the property until 30 days after the commission’s report is received.” General Description of School: According to information provided by the District’s transportation consultant, the proposed school will accommodate 225 students and about 30 staff members. It is estimated that approximately 80% of the students use public transportation to go to school; this percentage of users will likely increase when the school is relocated to the Hinckley Road property. The school site will include 32 staff parking spaces (no parking spaces for st udents). The school will operate between the hours between 8:00 a.m. and 3:00 p.m. The facility will operate similar to a community college in that students will arrive and depart based upon their specific class schedules. Zoning Compliance: The property is currently zoned Inner Bayshore (IB). Within the IB Zone class or school uses are permitted, subject to the following criteria: “class or school uses in office structures over twenty thousand (20,000) gross square feet, where the total class or school use does not exceed twenty (20) percent of the gross floor area on the lot, and with parking as set forth in Se ction 25.43.080 of this Community Development Department PLANNING COMMISSION STAFF REPORT PROPOSED ACQUISITION OF PROPERTY LOCATED AT 858-860 HINCKLEY ROAD BY THE SAN MATEO UNION HIGH SCHOOL DISTRICT (SMUSHD) FOR CONSTRUCTION OF A NEW CONTINUATION HIGH SCHOOL/ALTERNATIVE HIGH SCHOOL Meeting Date: April 9, 2018 REGULAR ACTION Item No: 8(d) 2 chapter”. Though the proposed use does will not meet the specific criteria described above, the general nature of the proposed use is similar to that stated. Public School Districts May Exempt Themselves from Local Regulations: It is notable that SMUHSD, as a public school district, may take action to exempt from City regulations for the construction of classroom facilities on any property that it owns. Pursuant to Government Code Section 53094(b) “the governing board of a school district, that has complied with the requirements of Section 65352.2 of this code and Section 21151.2 of the Public Resources Code, by a vote of two-thirds of its members, may render a city or county zoning ordinance inapplicable to a proposed use of property by the school district. The governing board of the school district may not take this action when the proposed use of the property by the school district is for non-classroom facilities, including, but not limited to, warehouses, administrative buildings, and automotive storage and repair buildings”. Since the proposed facility is to be used as classroom space, SMUHSD is likely to use this exemption from local regulation for the new continuation high school/alternative high school on Hinckley Road. PLANNING COMMISSION ACTION Staff recommends that the Planning Commission and acknowledge receipt of the notice and determine that it does not object to the intended purchase as set forth in the notice. Staff will forward written confirmation of the Commission’s determination within the required timeframe. Prepared by: William Meeker, Community Development Director Attachments:  Public Hearing Notice (Mailed: March 30, 2018)  SMUHSD Notice of Proposed Acquisition of Property (Dated: March 20, 2018)  Inner Bayshore (IB) Zoning Regulations San Mateo Union High School District Kevin Skelly, Ph.D., Superintendent Elizabeth McManus, Deputy Superintendent Business Services Kirk Black , Ed.D., Deputy Supt. Human Resources & Instruction Kindylee Mackamul, Associate Superintendent Student Services March 20 , 2018 VlA E-MAIL City of Burlingame Planning Commission PlanningCommissioners@Burlingame.org Re: Notice of proposed acquisition of real property by San Mateo Union High School District for New Continuation High School/Alternative High School Project Property : 858 and 860 Hinckley Road , Burlingame, CA APN: 026-310-480 Pursuant to Public Resources Code Section 21151.2 , the San Mateo Union High School District ("District") hereby gives notice to the City of Burlingame Planning Commission of its intent to acquire the fee simple interest of certain real property located at 858 & 860 Hinckley Road, Burlingame , California 94110 ( the "Property"). The District intends to acquire the Property to construct the New Continuation High School/ Alternative High School ("Project") to replace Peninsula High School , which is currently located at 300 Piedmont Avenue, San Bruno, California. The Project consists of the demolition of the facility that currently exists on the Property, and the construction of a new educational facility on the Property. Pursuant to Section 21151.2, the Board of Trustees of the District ("Board") will not acquire title to the Property until the District has timely received the Planning Commission's written report of the investigation and its recommendations concerning acquisition of the Property. Please direct any questions regarding this matter to the undersigned. Sincerely, Eliz be h McManus ~ Deputy Superintendent Business Services San Mateo Union High School District Enclosure: Legal description of Property Cc: Sean Absher, Esq . Shana Inspektor, Esq. 650 North Delaware Street, San Mateo , CA 94401-1732 (650) 558 -2299 (650) 762 -0249 FAX Adult School -Aragon -Burlingame -Capuchino -Hillsdale -Middle College -Mills -Peninsula -San Mateo An Equal Opportunity Employer LEGAL DESCRIPTION Real property in the City of Burlingame, County of San Mateo, State of California, described as follows: PARCEL ONE: LOTS 15 AND 16, AND THE NORTHEASTERLY 8.50 FEET, FRONT AND REAR MEASUREMENTS, OF LOT 17, BLOCK 5, AS DESIGNATED ON T HE MAP ENTITLED "EAST MILLSDALE INDUSTRIAL PARK UNIT NO. 2, BURLINGAME , SAN MATEO COUNTY, CALIFORNIA ", WHICH MAP WAS FILED IN THE OFFICE OF THE RECORDER OF THE COUNTY OF SAN MATEO , STATE OF CALIFORNIA, ON AUGUST 03, 1959, IN BOOK 52 OF MAPS, PAGES 4, 5 AND 6 . PARCEL TWO : A NON -EXCLUSIVE EASEMENT FOR INGRESS AND EGRESS AND DRIVEWAY PURPOSES WITHIN THE FOLLOWING DESCRIBED STRIP OF LAND : BEGINNING AT THE POINT OF INTERSECTION OF THE NORTHEASTERLY LINE OF LOT 15, BLOCK 5, WITH THE NORTHWESTERLY LINE OF HINCKLEY ROAD, AS SAID LOT, BLOCK AND ROAD ARE SHOWN ON THAT CERTAIN MAP ENTITLED, "EAST MILLSDALE INDUSTRIAL PARK UNIT NO. 2, BURLINGAME, SAN MATEO COUNTY, CALIFORNIA", WHICH MAP WAS FILED IN THE OFFICE OF THE RECORDER OF THE COUNTY OF SAN MATEO, STATE OF CALIFORN I A, ON AUGUST 03, 1959, IN BOOK 52 OF MAPS, PAGES 4, 5 AND 6; THENCE FROM SAID POINT OF BEGINNING, ALONG THE NORTHEASTERLY LINE OF SAID LOT 15, NORTH 50° 41' 25" WEST, 213 FEET TO A POINT; THENCE LEAVING SAID NORTHEASTERLY LINE OF LOT 15 AND CROSSING THE LOTS 15, 16 AND 17 IN SAID BLOCK 5, SOUTH 39° 18 ' 35" WEST, 183 .50 FEET TO A POINT IN SAID LOT 17; THENCE SOUTH 50° 41' 25" EAST, 18 FEET; THENCE NORTH 39° 18 ' 35 " EAST, 171.50 FEET TO A POINT IN LOT 15; THENCE SOUTH 50° 41' 25" EAST, 40 FEET; THENCE SOUTH 39° 18' 35" WEST, 171.50 FEET TO A POINT IN SAID LOT 17 ; THENCE SOUTH 50° 41 ' 25" EAST, 18 FEET; THENCE NORTH 39° 18' 35" EAST, 171.50 FEET TO A POINT IN LOT 15; THENCE SOUTH 50° 41' 25" EAST, 137 FEET TO THE SAID NORTHWESTERLY LINE OF HINCKLEY ROAD; THENCE ALONG THE LAST MENTIONED LINE, NORTH 39° 18' 35" EAST, 12 FEET TO THE POINT OF BEGINNING. PARCEL THREE: NON-EXCLUSIVE EASEMENTS FOR INGRESS AND EGRESS AND DRIVEWAY PURPOSES WITHIN THE FOLLOWING DESCRIBED STRIPS OF LAND: A. BEGINNING AT THE POINT OF INTERSECTION OF THE SOUTHWESTERLY LINE OF LOT 19, BLOCK 5, WITH THE NORTHWESTERLY LINE OF HINCKLEY ROAD, AS SAID LOT, BLOCK AND ROAD ARE SHOWN ON THAT CERTAIN MAP ENTITLED, "EAST MILLSDALE INDUSTRIAL PARK UNIT NO. 2, BURLINGAME, SAN MATEO COUNTY, CALIFORNIA", WHICH MAP WAS FILED IN THE OFFICE OF THE RECORDER OF THE COUNTY OF SAN MATEO, STATE OF CALIFORNIA, ON AUGUST 03, 1959, IN BOOK 52 OF MAPS, PAGES 4, 5 AND 6; THENCE FROM SAID POINT OF BEGINNING, ALONG THE SOUTHWESTERLY LINE OF SAID LOT 19, NORTH 50° 41' 25 " WEST, 213 FEET; THENCE LEAVING SAID SOUTHWESTERLY LINE OF LOT 19, NORTH 39° 18 ' 35" EAST, 12 FEET; THENCE SOUTH 50° 41 ' 25" EAST, 213 FEET TO THE NORTHWESTERLY LINE OF HINCKLEY ROAD; THENCE ALONG SAID LINE OF HINCKLEY ROAD, SOUTH 39° 18' 35 " WEST, 12 FEET TO THE POINT OF BEGINNING. B. THE NORTHEASTERLY 12 FEET, FRONT AND REAR MEASUREMENTS, OF LOT 20, BLOCK 5, AS DESIGNATED ON THE MAP ENTITLED, "EAST MILLSDALE INDUSTRIAL PARK UNIT NO. 2, BURLINGAME, SAN MATEO COUNTY, CALIFORNIA", WHICH MAP WAS FILED IN THE OFFICE OF THE RECORDER OF THE COUNTY OF SAN MATEO, STATE OF CALIFORNIA,ON AUGUST 03, 1959, IN BOOK 52 OF MAPS, PAGES 4, 5 AND 6 . C. A STRIP OF LAND, 18 FEET IN WIDTH, LYING ADJACENT TO AND MEASURED AT RIGHT ANGLES SOUTHEASTERLY FROM THE FOLLOWING DESCRIBED LINE: BEGINNING AT A POINT ON THE SOUTHWESTERLY LINE OF LOT 19, BLOCK 5, AS DESIGNATED ON THE MAP ENTITLED, "EAST MILLSDALE INDUSTRIAL PARK UNIT NO. 2, BURLINGAME, SAN MATEO COUNTY, CALIFORNIA", WHICH MAP WAS FILED IN THE OFFICE OF THE RECORDER OF THE COUNTY OF SAN MATEO, STATE OF CALIFORNIA, ON AUGUST 03, 1959, IN BOOK 52 OF MAPS, PAGES 4, 5 AND 6, DISTANT THEREON SOUTH 50° 41' 25" EAST, 22 FEET FROM THE MOST WESTERLY CORNER OF SAID LOT 19, BLOCK 5; THENCE FROM SAID POINT OF BEGINNING, NORTH 39° 18' 35" WEST, PARALLEL WITH THE NORTHWESTERLY LINE OF LOTS 19, 18 AND 17, BLOCK 5, A DISTANCE OF 171.50 FEET. D. A STRIP OF LAND, 18 FEET IN WIDTH, ADJACENT TO AND MEASURED AT RIGHT ANGLES SOUTHEASTERLY FROM THE FOLLOWING DESCRIBED LINE: BEGINNING AT A POINT ON THE SOUTHWESTERLY LINE OF LOT 19, BLOCK 5, AS SHOWN ON THE MAP ENTITLED, "EAST MILLSDALE INDUSTRIAL PARK UNIT NO. 2, BURLINGAME, SAN MATEO COUNTY, CALIFORNIA", WHICH MAP WAS FILED IN THE OFFICE OF THE RECORDER OF THE COUNTY OF SAN MATEO, STATE OF CALIFORNIA, ON AUGUST 03, 1959, IN BOOK 52 OF MAPS, PAGES 4, 5, AND 6, DISTANT THEREON SOUTH 50° 41' 25" EAST, 80 FEET FROM THE MOST WESTERLY CORNER OF SAID LOT 19, BLOCK 5; THENCE FROM SAID POINT OF BEGINNING, NORTH 39° 18' 35" EAST, PARALLEL WITH THE NORTHWESTERLY LINE OF LOTS 19, 18 AND 17 IN BLOCK 5, A DISTANCE OF 171.50 FEET. APN: 026-310-480; JPN: 026-031-310-48A Chapter 25.43 INNER BAYSHORE DISTRICT (IB) Note * Prior ordinance history: Ord. 1495, 1552, 1586, 1603, 1727, 1748. 25.43.010 Scope and purpose of regulations. It is the purpose and policy of this chapter to designate for the Inner Bayshore (IB) an office/light industrial park area which will serve as a transition between the Shoreline Commercial District (SL) and the Rollins Road (RR) zones. In its uses, this district shall be consistent with the intent of the General Plan and the Bayfront Specific Plan, Inner Bayshore subarea, to provide professional and administrative offices, distribution, service, light industrial and other uses supported by access to San Francisco International Airport. An additional purpose of this district is to create a supportive interface between the adjacent hotel, restaurant and other Shoreline commercial activities and Bay Trail recreation area nearby which front on San Francisco Bay. These proposed uses shall further enhance the economic and aesthetic advantages of the adjacent Shoreline subarea and the economic base of the city. (Ord. 1760 § 2, (2005); Ord. 1793 § 29, (2006)) 25.43.020 Permitted uses. The following uses are permitted in the IB district: (a) Air courier, delivery or other transshipment services, including freight forwarding, which: (1) Provide on-site parking for all fleet vehicles, and (2) Provide on-site parking for all employees; (b) Any light industrial or manufacturing use such as electronic, furniture, biotechnology, drug, pharmaceutical and printing conducted wholly within a completely enclosed building, including associated laboratories, which: (1) Has a floor area ratio of no more than 0.5, and (2) Does not use impact presses of over twenty (20) tons rated capacity or machine-operated drop hammers, and (3) Encloses compressors and generators so that there is no increase in the twenty-four(24) hour ambient noise level in excess of 3 dBA at any property line, and (4) Does not create an obnoxious or offensive presence or emission of odor, dust, gas, noise, bright lights, smoke, vibration, harmful sewer waste or have a detrimental effect on permissible adjacent uses; (c) Non-retail service businesses, including contractors, which: (1) Provide on-site parking for all company vehicles, and (2) On-site parking for all employees, and (3) Adequate on-site, designated space for loading and unloading goods, equipment and materials; (d) Class or school uses in office structures over twenty thousand (20,000) gross square feet, where the total class or school use does not exceed twenty (20) percent of the gross floor area on the lot, and with parking as set forth in Section 25.43.080 of this chapter; (e) Incidental food establishments within a multi-use building which meet all of the following criteria: (1) Is not the primary use of the building or structure, and (2) Is open no earlier than 6:00 a.m. and no later than 5:00 p.m., and closed Saturdays and Sundays, and (3) Has a maximum size of one thousand five hundred (1,500) square feet, and (4) Is at least fifteen (15) feet in length and fifteen (15) feet in width, and (5) Has no sale of alcoholic beverages, and (6) Provides parking as set forth in Section 25.43.080 of this chapter; (f) Laboratory and clean room facilities for research, testing or creating products and goods; (g) Office uses, with a maximum floor area ratio of 0.9, that may include health services and medical clinics not to exceed five thousand (5,000) square feet total in office structures over twenty thousand (20,000) gross square feet, with parking as set forth in Section 25.43.080; (h) Warehouse uses and warehouse storage and distribution of goods, materials, liquids and equipment conducted wholly within an enclosed building with a floor area ratio of not more than 0.5; (i) Outdoor storage of materials incidental to permitted uses with a maximum storage area of ten (10) percent of the gross lot area; all contractor's storage or outdoor storage areas shall be: (1) Limited to side and rear yards, and (2) Shall be paved, and (3) Shall be enclosed by an opaque fence or wall eight (8) feet in height; and (j) Accessory uses which are necessary for the permitted uses under this section and Section 25.43.030; and all uses shall be required to provide trash enclosures adequate in size to accommodate storage for all trash generated on- site and an area adequate for recycling items as required by the city. (Ord. 1760 § 2, (2005); Ord. 1766 § 8, (2005)) 25.43.027 Hours for massage, bathing, tanning, or similar establishments and conditional use permit. A massage, bathing, tanning, or similar establishment use shall be limited to the hours of 7:00 a.m. to 9:00 p.m. unless a conditional use permit is approved by the planning commission pursuant to Chapter 25.52 to allow use outside those hours. (Ord. 1793 § 30, (2006)) 25.43.030 Conditional uses. The following are conditional uses requiring a conditional use permit: (a) Any use with a structure that: (1) Exceeds the maximum floor area ratio set forth in Section 25.43.020, or (2) Exceeds the development density standards for that use established in the Inner Bayshore subarea of the Bayfront Specific Plan, unless otherwise prohibited by this chapter, or (3) Does not comply with a measurable standard of the design guidelines for that use established in the Inner Bayshore subarea of the Bayffont Specific Plan, unless otherwise prohibited by this chapter; (b) Any light industrial or manufacturing use such as electronic, furniture, biotechnology, drug, pharmaceutical and printing conducted wholly within a completely enclosed building, including associated laboratories, which exceeds any of the performance criteria of Section 25.43.020(b). (c) Automobile rental businesses which meet the following minimum standards: (1) The use is the sole tenant and only occupant of the lot, and (2) The lot is at least seven-tenths (0.7) of an acre, and (3) Parking is provided on-site for storage of at least twenty-five (25) percent of the cars rented monthly, based on an annual average for the site, and (4) Parking is provided on-site for all employees and customers, and (5) The use meets all the other requirements of development in the district, including peak how trip generation at critical intersections as defined in the traffic analyzer and Specific Area Plan for the Bayfront Anza areas; (d) Technical schools with training directly related to permitted or conditional uses in the Inner Bayshore area, with parking as required by chapter 25.70; (e) Convention and exhibition facilities; (f) Incidental food establishment uses that are not the primary use of a building and do not meet the other criteria of Section 25.43.020; (g) Outdoor storage of materials incidental to permitted uses which storage exceeds ten (10) percent of the gross lot area and contractors storage yards; any such use shall be limited to side and rear yards, shall be paved, and shall be enclosed by an opaque fence or wall eight (8) feet in height; (h) Structures over thirty-five (35) feet in height; (i) Any use similar in nature to one which is permitted or for which a permit is required in this district at a density determined not to exceed the trip generation for the planned use of the lot using the adopted Bayfront traffic analyzer. (j) Drive-in services or takeout services associated with permitted and conditional uses. (Ord. 1760 § 2, (2005); Ord. 1766 § 9, (2005)) 25.43.040 Prohibited uses. Uses not listed as permitted or conditional are prohibited in the IB district, specifically including the following: (a) Automobile rental uses that do not comply with the criteria of Section 25.43.030; (b) Automobile dealers and sales lots, wholesale and retail, and automobile leasing, whether freestanding, in office buildings, or in connection with other uses; (c) Automobile wrecking, junkyards, storage or baling of scraps, paper, tags, sacks or metals; (d) Freestanding food establishments on any properties without frontage on Bayshore Highway; (e) Gasoline service stations on any properties without frontage on Bayshore Highway; (f) Residential uses and buildings, except as part of a hotel as permitted under Section 25.43.045 of this chapter; (g) Limousine and livery businesses and associated storage facilities; (h) Adult oriented businesses as defined in Chapter 25.76; (i) Any use determined to be obnoxious or offensive; (j) Hotels, motels, and extended stay hotels without lot frontage on Bayshore Highway; (k) Long term airport parking facilities; and (l) Massage, bathing, tanning or similar establishments. (Ord. 1760 § 2, (2005)) 25.43.045 Properties with frontage on Bayshore Highway. (a) In addition to the permitted uses in the Inner Bayshore district, the following uses are permitted uses on properties located in the Inner Bayshore Zone that have street frontage on Bayshore Highway: (1) Free-standing food establishments with a floor area ratio of no more than 0.15 and with parking as set forth in Section 25.43.080, (2) Motels and hotels with a maximum density of sixty-five (65) rooms to the acre and a floor area ratio of 1.0 or less; facilities provided on-site may include such retail sales and personal service uses as meal and beverage services, barber and beauty shops, smoke shops, and shuttle bus service to serve only hotel guests so long as the operations do not use parking required for primary hotel use, conventions and meeting facilities or services which are clearly incidental and accessory to provision of lodging accommodations; and no more than one dwelling unit within the motel or hotel structure that is used exclusively by the owner or manager of the motel or hotel, (3) Offices, and (4) Retail sales and personal service businesses with a maximum of five thousand (5,000) gross square feet or less and which singly or in combination shall not to exceed fifty (50) percent of the floor area of any structure; (b) In addition to the conditional uses allowed in the Inner Bayshore Zone, the following uses are allowed with a conditional use permit on properties with street frontage on Bayshore Highway located in the Inner Bayshore Subarea: (1) Structures over thirty-five (35) feet in height, (2) Convention and exhibition facilities, (3) Commercial recreation, (4) Hotels and motels that do not meet the criteria of subsection (a) of this section, (5) Any light industrial or manufacturing use, such as electronic, furniture, biotechnology, drug, pharmaceutical, and printing, including associated laboratories, (6) A car rental desk on a lot occupied by a hotel that does not affect the availability of on-site parking for hotel guests and the use and parking for any on-site meeting facilities, (7) Provision by a hotel of a park and fly program that involves the long term parking of vehicles at a lot that is not approved as a commercial parking lot and does not affect the availability of on-site parking for hotel guests and the use and parking for any on-site meeting facilities, (8) Gasoline service stations with a maximum of five hundred (500) square feet of retail sales area, excluding specialty food shops, and limited to minor automobile repair services, (9) Incidental food sales and services in office buildings of twenty thousand (20,000) square feet or more, not to exceed a maximum of one thousand five hundred (1,500) square feet, (10) Drive-in and take-out services associated with permitted or conditional uses, and (11) Any use similar in nature to one which is permitted or for which a permit is required in this district at a density determined not to exceed the trip generation for the planted use of the lot using the adopted Bayfront traffic analyzer, (c) In addition to the uses prohibited in Section 25.43.040 as expressly modified in subsections (a) and (b) above, the following additional uses are prohibited: (1) Outdoor storage, including outdoor storage of materials or goods associated with a permitted or conditional use, and (2) Extended stay hotels. (Ord. 1760 § 2, (2005); Ord. 1766 §§ 10, 11 (2005)) 25.43.052 Design review. Construction and alterations including substantial construction or change to more than fifty (50) percent of the front façade or change to more than fifty (50) percent of any façade facing a public or private street or parking lot shall be subject to design review based on the design guidelines for the Inner Bayshore subarea of the Bayfront Specific Plan and shall be processed as provided in Section 25.57.030. (a) A design review application in the IB district shall be reviewed by the planning commission for the following considerations: (1) Support of the pattern of diverse architectural styles as defined in the design guidelines for the Inner Bayshore subarea, (2) Respect and promotion of the streetscape by the placement of buildings to maximize the commercial use of the street frontage, off street public spaces, and by locating parking so that it does not dominate street frontages, and for properties fronting on Bayshore Highway, that the design contributes to the interface with the Shoreline subarea as directed in the Bayshore specific plan, (3) On visually prominent and gateway sites, whether the design fits the site and is compatible with the surrounding development and consistent with the design guidelines for the Inner Bayshore subarea, (4) Compatibility of the architecture and landscaping with the design guidelines for the Inner Bayshore subarea including materials used in existing development, location and use of plant materials, and compatibility with transitions where changes in land use occur nearby, (5) Architectural design consistency by using a single architectural style on the lot that is consistent among primary elements of the structure(s) and with the directives of the design guidelines for the Inner Bayshore subarea, (6) Provision of site features identified in the design guidelines such as landscaping and pedestrian circulation which enriches the existing opportunities of the commercial neighborhood; (b) When any part of a commercial structure is subject to design review, any awnings on the commercial structures shall be included in the design review; (c) Exemptions from design review: (1) Applications for building permits or planning approvals for development in the B district filed before August 4, 2005, and certain amendments to those applications or permits as specifically provided in Ordinance No. 1760. (Ord. 1760 § 2, (2005)) 25.43.055 Setbacks. The following minimum setbacks shall apply to all parcels located in the Inner Bayshore district: (a) Front setbacks: (1) All properties shall have a front setback of at least ten (10) feet except for front setbacks from Bayshore Highway, (2) On lots with any street frontage on Bayshore Highway, there shall be an average front setback of fifteen (15) feet from Bayshore Highway; with at least forty (40) percent of the structure at the maximum setback of fifteen (15) feet; (b) There shall be a minimum ten (10) foot side setback; (c) Except for rear setbacks from Bayshore Highway, there is no minimum rear setback in the IB district; (d) In addition to the setbacks set forth above, there shall be a fifteen (15) foot setback from Bayshore Highway for all below grade construction. (Ord. 1760 § 2, (2005)) 25.43.060 Minimum lot size. There shall be a minimum lot size of ten thousand (10,000) square feet and a minimum street frontage of fifty (50) feet. No property in this district shall be divided or subdivided into a lot with less area or less street frontage. (Ord. 1760 § 2, (2005)) 25.44.065 No variance for lot size and street frontage. Not withstanding any other provision of this code, no variance for lot size or street frontage shall be granted to any property within this district. (Ord. 1760 § 2, (2005)) 25.43.070 Landscaping and design requirements. The following landscaping requirements shall apply to all parcels: (a) The landscape requirements of the design guidelines for the Inner Bayshore subarea of the Bayfront Specific Plan as adopted by the city council shall be met, including the requirement that sixty (60) percent of the front setback shall be landscaped. (b) On properties with any lot front on Bayshore Highway, the following additional landscape requirements shall apply: (1) A minimum of fifteen (15) percent of the total area of each lot shall be suitably landscaped and the landscaping shall be properly maintained. A landscape plan shall be submitted with any application for an approval under this title for any use on the lot. (2) At least sixty (60) percent of the area between the front property line and the front of any building on a lot shall be landscaped. Where no building exists along a lot front, at least sixty (60) percent of the front setback area shall be landscaped; landscaping may include walkways and seating features. (3) At least ten (10) percent of all parking areas shall be landscaped. (4) A properly fenced and screened area for refuse, garbage, and recycling containers shall be provided for each building or group of buildings on a lot. Any such area shall be located at the side or rear of a building and shall not be located within one hundred (100) feet of the rear property line. (5) Loading docks and truck loading access shall be fully enclosed and shall be located at the side or rear of a building. (6) No parking areas shall be located within fifteen (15) feet of any lot front on Bayshore Highway, or within the side setback of any lot with a property line on Bayshore Highway. Driveways are allowed in any such side setback, but the driveways shall not be considered as landscaped area. No parking areas shall be located between any structure and the lot front, except for loading zones. (Ord. 1760 § 2, (2005)) 25.43.080 Parking requirements. (a) Except as otherwise set forth in this section, all uses shall provide parking in accordance with Chapter 25.70. (b) Free-standing Food Establishments. Free-standing food establishments shall provide customer parking on-site at the rate of one space for each one hundred (100) square feet of gross floor area; and employee parking on -site at the rate of one space for each one thousand (1000) square feet of gross floor area. (c) Incidental Food Establishments. Food establishments that are not the primary use of a building shall provide parking on-site at the rate of one parking space for each three hundred (300) square feet of gross floor area of food establishment use. (d) Health Service and Medical Clinic uses. Health service and medical clinic uses in structures of more than twenty thousand (20,000) gross square feet shall provide parking on-site at the rate of one parking space for each three hundred (300) square feet of gross floor area occupied by the uses; health service and medical clinic uses in structures smaller than twenty thousand (20,000) square feet shall provide parking on site at the rate of one parking space for each two hundred fifty (250) square feet of gross floor area. (Ord. 1760 § 2, (2005); Ord. 1766 § 12, (2005)) PROJECT LOCATION 834 Crossway Road Item No. 8a Regular Action Items Item No. 8a Regular Action Items City of Burlingame Design Review Address: 834 Crossway Road Meeting Date: June 25, 2018 Request: Application for Design Review for a new, two-story single family dwelling with a detached garage. Applicant and Architect: John Nguyen, Dulon Inc. APN: 029-021-310 Property Owner: Diane McGlown Lot Area: 6,737 SF General Plan: Low Density Residential Zoning: R-1 Environmental Review Status: The project is Categorically Exempt from review pursuant to the California Environmental Quality Act (CEQA), per Section 15303 (a), which states that construction of a limited number of new, small facilities or structures including one single family residence or a second dwelling unit in a residential zone is exempt from environmental review. In urbanized areas, up to three single-family residences maybe constructed or converted under this exemption. Project Description: The subject property is an interior lot bordering an R-2 zone at the left side and rear of the property. The applicant is proposing to demolish an existing one-story house and detached garage to build a new, two-story single family dwelling with a detached garage. The proposed house will have a total floor area of 3,603 SF (0.53 FAR) where 3,656 SF (0.54 FAR) is the maximum allowed (including 77 SF covered porch exemption). The new single family dwelling will contain four bedrooms. Two parking spaces, one of which must be covered, are required on-site. Two covered parking spaces are provided in the detached garage (20’ x 20’ clear interior dimensions) and one uncovered parking space (9’ x 20’) is provided in the driveway. Therefore, the project is in compliance with off-street parking requirements. All other Zoning Code requirements have been met. The applicant is requesting the following applications: ƒ Design Review for a new single family dwelling (C.S. 25.57.010 (a)(1)). 834 Crossway Road Lot Area: 6,737 SF Plans date stamped: June 14, 2018 ORIGINAL 03/14/18 Plans REVISED 06/14/18 Plans ALLOWED/REQUIRED Front Setback (1st flr): (2nd flr): 20’-0” 20’-0” 18’-7” (to porch) 20’-1” 18’-7” (block average) 20’-0” Side Setback (left): (right): 4’-9” 9’-6” 4’-0” 9’-6” 4'-0" 4’-0” Rear Setback (1st flr): (2nd flr): 68’-2” 68’-2” 67’-0” 67’-0” 15'-0" 20'-0" Lot Coverage: 2,217 SF 32.9% 2,355 SF 35% 2,695 SF 40% FAR: 3,313 SF 0.49 FAR 3,603 SF 0.53 FAR 3,656 SF 1 0.54 FAR # of bedrooms: 5 4 --- Design Review 834 Crossway Road 2 ORIGINAL 03/14/18 Plans REVISED 06/14/18 Plans ALLOWED/REQUIRED Off-Street Parking: 2 covered (20’ x 20’ clear interior) 1 uncovered (9' x 20') no change 2 covered (20' x 20' clear interior) 1 uncovered (9' x 20') Building Height: 26’-0” no change 30'-0" DH Envelope: complies complies CS 25.26.075 1 (0.32 x 6,737) + 1,100 + 400 SF = 3,656 SF (0.54) FAR Accessory Structure ORIGINAL 03/14/18 Plans REVISED 06/14/18 Plans ALLOWED/REQUIRED Setback: Side: Rear: From house: 1’-2” (right), 14’-6” (left) 23’-11” 27’-4” no change no change 24’-6” C.S. 25.26.073(b)(4) exempts accessory structures located in the rear 30% of a lot Accessory Structure Size: 452 SF no change 600 SF Building Length: 21’-3” no change Special Permit required if structure exceeds 28’-0” in length Plate Height: 8’-0” no change CUP required for plate height greater than 9’-0” above grade Building Height: 14’-2” 15’-0” 15’-0” above grade if plate height does not exceed 9’-0” Windows in Accessory Structure: no windows window above garage door (proposed 10’-6” from property line) windows within 10' of property line or more than 10’ above grade require a Conditional Use Permit2 Staff Comments: See attached memos from the Engineering, Building, Fire, Parks and Stormwater Divisions. Design Review Study Meeting: At the Planning Commission Design Review Study meeting on April 9, 2018, the Commission had several comments for the project and referred the application to a design review consultant (see attached April 9, 2018 Planning Commission Minutes). Listed below is a summary of the Commission’s main concerns from the Design Review Study meeting: x Front Elevation o Hard to know where the front is; o Re-work the entire elevation and give it more presence in relationship to the street. x Front entry and porch o Not noticeable; consider enlarging and bring forth up the driveway since there is a 200 SF FAR exemption for front porches; o Side facing door may present privacy issue for neighbor, worth revisiting. Design Review 834 Crossway Road 3 x Right Side Elevation – blank wall (interior stairs on other side) o Consider breaking that sill line to add another window; don’t leave blank. x Corner Boards o Proposed corner boards do not match with the traditional styling; consider mitered corners or similar to what is proposed with the garage corners. x Landscaping o Too much concrete hardscape surrounding detached garage; break it up with pavers or change of material to soften the hardscaping in that area. x Miscellaneous o Add detailing (e.g. knee braces or corbel in the corners and at the ridges); o Flat elevations (i.e. define transition between top and bottom floor); o Long and narrow lot presents physical constraints requiring more creativity; o Utilize leftover FAR and FAR exemptions to rework design. The applicant submitted revised plans date stamped June 14, 2018 to address the Planning Commission’s comments and concerns. A discussion of the analysis of the revised project and recommendation by the design review consultant is provided in the next section. Analysis and Recommendation by Design Reviewer: Please refer to the attached design reviewer’s analysis and recommendation, dated June 8, 2018, for a detailed review of the project. The design reviewer notes that moving the porch, increasing the roof pitch, and “added featured windows and added design consistency” have improved the project. Based on the design review analysis of the project, the design reviewer supports approval of the project as proposed. Design Review Criteria: The criteria for design review as established in Ordinance No. 1591 adopted by the Council on April 20, 1998 are outlined as follows: 1. Compatibility of the architectural style with that of the existing character of the neighborhood; 2. Respect for the parking and garage patterns in the neighborhood; 3. Architectural style and mass and bulk of structure; 4. Interface of the proposed structure with the structures on adjacent properties; and 5. Landscaping and its proportion to mass and bulk of structural components. Suggested Findings for Design Review: That the architectural style, mass and bulk of the addition (featuring a combination of hip and gable roofs, proportional plate heights, aluminum clad windows, and wood trim) is compatible with the character of the neighborhood and that the windows and architectural elements of the proposed structure are placed so that the structure respects the interface with the structures on adjacent properties, therefore the project may be found to be compatible with the requirements of the City’s five design review criteria. Planning Commission Action: The Planning Commission should conduct a public hearing on the application, and consider public testimony and the analysis contained within the staff report. Action should include specific findings supporting the Planning Commission’s decision, and should be affirmed by resolution of the Planning Commission. The reasons for any action should be stated clearly for the record. At the public hearing the following conditions should be considered: Design Review 834 Crossway Road 4 1. that the project shall be built as shown on the plans submitted to the Planning Division date stamped June 14, 2018, sheets G001, A100 through A203, and L101; 2. that any changes to building materials, exterior finishes, windows, architectural features, roof height or pitch, and amount or type of hardscape materials shall be subject to Planning Division or Planning Commission review (FYI or amendment to be determined by Planning staff); 3. that any changes to the size or envelope of the first or second floors, or garage, which would include adding or enlarging a dormer(s), shall require an amendment to this permit; 4. that any recycling containers, debris boxes or dumpsters for the construction project shall be placed upon the private property, if feasible, as determined by the Community Development Director; 5. that demolition or removal of the existing structures and any grading or earth moving on the site shall not occur until a building permit has been issued and such site work shall be required to comply with all the regulations of the Bay Area Air Quality Management District; 6. that prior to issuance of a building permit for construction of the project, the project construction plans shall be modified to include a cover sheet listing all conditions of approval adopted by the Planning Commission, or City Council on appeal; which shall remain a part of all sets of approved plans throughout the construction process. Compliance with all conditions of approval is required; the conditions of approval shall not be modified or changed without the approval of the Planning Commission, or City Council on appeal; 7. that all air ducts, plumbing vents, and flues shall be combined, where possible, to a single termination and installed on the portions of the roof not visible from the street; and that these venting details shall be included and approved in the construction plans before a Building permit is issued; 8. that the project shall comply with the Construction and Demolition Debris Recycling Ordinance which requires affected demolition, new construction and alteration projects to submit a Waste Reduction plan and meet recycling requirements; any partial or full demolition of a structure, interior or exterior, shall require a demolition permit; 9. that the project shall meet all the requirements of the California Building and Uniform Fire Codes, 2016 Edition, as amended by the City of Burlingame. THE FOLLOWING CONDITIONS SHALL BE MET DURING THE BUILDING INSPECTION PROCESS PRIOR TO THE INSPECTIONS NOTED IN EACH CONDITION: 10. that prior to scheduling the framing inspection the applicant shall provide a certification by the project architect or residential designer, or another architect or residential design professional, that demonstrates that the project falls at or below the maximum approved floor area ratio for the property; 11. prior to scheduling the framing inspection the project architect or residential designer, or another architect or residential design professional, shall provide an architectural certification that the architectural details shown in the approved design which should be evident at framing, such as window locations and bays, are built as shown on the approved plans; architectural certification documenting framing compliance with approved design shall be submitted to the Building Division before the final framing inspection shall be scheduled; 12. that prior to scheduling the roof deck inspection, a licensed surveyor shall shoot the height of the roof ridge and provide certification of that height to the Building Division; and 13. that prior to final inspection, Planning Division staff will inspect and note compliance of the architectural Design Review 834 Crossway Road 5 details (trim materials, window type, etc.) to verify that the project has been built according to the approved Planning and Building plans. ‘Amelia Kolokihakaufisi Associate Planner c. John Nguyen, Dulon Inc., applicant and designer Diane McGlown, property owner Attachments: Design Review Analysis, dated June 8, 2018 April 9, 2018 Planning Commission Minutes Application to the Planning Commission Applicant Letter of Explanation Staff Comments Planning Commission Resolution (Proposed) Notice of Public Hearing – Mailed June 15, 2018 Aerial Photo 1ST FLOOR44' - 6"T.O. GRADE42' - 10 11/16"AVE. T.O. CURB41' - 0 1/16"1ST FL TOP PLATE52' - 6"2ND FLOOR53' - 6"2ND FL TOP PLATE61' - 6"AVE. LEFT+40.99'30' - 0"AVE. RIGHT+39.155PROPERTY LINE @ FRONT8' - 0"5' - 6"8' - 0"PROPERTY LINE12' - 0"30'-0" HEIGHT LIMIT12' - 0"45°PROPERTY LINE@ REART.O. ROOF RIDGE67' - 0 3/8"7' - 6"ASPHALT SHINGLE ROOFPAINTED GLV MTLGUTTER, TYP.PAINTED 2x8 WDFASCIA BDPAINTED 3 1/2"WD. TRIMSTAINED 8x8 WD. POST6" LAP SIDINGPAINTED 9 1/4" WDTRIMALUMINUM CLADWINDOWS WITH GRIDSWHERE INDICATED, TYP.4 5 °DOWN SPOUT26' - 0"36" x 60"DOUBLEHUNGEGRESSWINDOWL36" x 60"DOUBLEHUNGEGRESSWINDOWLLLLL1021ST FLOOR44' - 6"T.O. GRADE42' - 10 11/16"AVE. T.O. CURB41' - 0 1/16"1ST FL TOP PLATE52' - 6"2ND FLOOR53' - 6"2ND FL TOP PLATE61' - 6"30'-0" HEIGHT LIMITT.O. ROOF RIDGE67' - 0 3/8"8' - 0"5' - 6"8' - 0"ALUMINUM CLAD WINDOWS WITHGRIDS WHERE INDICATED, TYP.STANDING SEAM METAL ROOFPAINTED GLV MTL GUTTER, TYP.DOWNSPOUT26' - 0"CHIMNEY CAP & FLUEEXTENSIONSTONE VENEERAROUNDCHIMNEYLLLLTTTMMMLLLLNNOPENING NO.WIDTHHEIGHTQUANTITYOPENINGAREAWALL LEVELTOTALWALL AREAFIRE SEPARATIONDISTANCEDEGREE OFPROTECTIONALLOWABLEWALL OPENINGL115 SFSECOND134 SF≥ 30'PROTECTEDNO LIMITLL1023' - 0"5' - 0"115 SFSECOND131 SF≥ 30'NO LIMIT3' - 0"5' - 0"230 SFFIRST120 SF≥ 30'NO LIMIT3' - 0"5' - 0"121 SFFIRST139 SF≥ 30'NO LIMIT3' - 0"7' - 0"TOTAL FIRST FLOOR WALL OPENING:81 SFTOTAL SECOND FLOOR WALL OPENING:30 SFPROPOSED FIRST FLOOR WALL OPENINGS:NO LIMITS (OK)PROPOSED SECOND FLOOR WALL OPENINGS:NO LIMITS (OK)FRONT ELEVATION ALLOWABLE WALL OPENINGSPROTECTEDPROTECTEDPROTECTEDL230 SFFIRST139 SF≥ 30'NO LIMIT3' - 0"5' - 0"PROTECTEDTOTAL FIRST FLOOR WALL OPENING:135.5 SFTOTAL SECOND FLOOR WALL OPENING:48.75 SFPROPOSED FIRST FLOOR WALL OPENINGS:135.5 / 547 = 24.8% (OK)PROPOSED SECOND FLOOR WALL OPENINGS:48.75 / 379 = 12.9% (OK)OPENING NO.WIDTHHEIGHTQUANTITYOPENINGAREAWALL LEVELTOTALWALL AREAFIRE SEPARATIONDISTANCEDEGREE OFPROTECTIONALLOWABLEWALL OPENINGL115 SFSECOND155 SF9' - 5"PROTECTED25%LTN3' - 0"5' - 0"115 SFSECOND153 SF25%3' - 0"5' - 0"318.75 SFSECOND71 SF45%2' - 6"2' - 6"28 SFFISRT149 SF25%2' - 0"2' - 0"PROPOSED RIGHT ELEVATION ALLOWABLE WALL OPENINGSPROTECTEDPROTECTEDPROTECTED9' - 4"12' - 1"9' - 11"L33' - 0"5' - 0"45 SFFIRST135 SF9' - 5"PROTECTEDM32' - 6"5' - 0"37.5 SFFIRST130 SF12' - 1"PROTECTEDL33' - 0"5' - 0"45 SFFIRST133 SF9' - 4"PROTECTED25%45%25%PROJECT NUMBERDATEDRAWN BYCHECKED BYSCALENOTE -THE PURPOSE OF THE DRAWINGSPROVIDED IS TO SHOW GENERALARRANGEMENT OF REMODELING &ADDITIONS TO AN EXISTINGSTRUCTURE. ASSUMPTIONS HAVEBEEN MADE REGARDING THESTRUCTURAL & ARCHITECTURALCONDITIONS OF EXISTING WALLS,FLOORS & CEILINGS WHICH WILL NEEDTO BE VERIFIED & PERHAPS MODIFIEDAS THESE CONDITIONS ARE REVEALEDDURING CONSTRUCTION. THEDESIGNER DOES NOT ASSUME ANYRESPONSIBILITY FOR THE EXISTINGSTRUCTURE.DULON, INC.510.552.2641INFO@DULONDESIGNS.COMBURLINGAME, CALIFORNIA 94010DESIGN REVIEW PACKAGEAs indicated6/13/2018 12:56:37 PM2017.101805/09/2018JNJNA201MCGLOWN RESIDENCE834 CROSSWAY ROADFRONT & RIGHTELEVATIONSSCALE: 1/4" = 1'-0"1PROPOSED FRONT ELEVATIONREVISION DESCRIPTION DATE1 PLAN CHECK REVIEW 01/10/20182 DESIGN REVIEW SUBMITTAL 06/13/2018SCALE: 1/4" = 1'-0"2PROPOSED RIGHT ELEVATION 1ST FLOOR44' - 6"T.O. GRADE42' - 10 11/16"AVE. T.O. CURB41' - 0 1/16"1ST FL TOP PLATE52' - 6"2ND FLOOR53' - 6"2ND FL TOP PLATE61' - 6"T.O. ROOF RIDGE67' - 0 3/8"30'-0" HEIGHT LIMIT8' - 0"5' - 6"8' - 0"`DOWNSPOUTPAINTED GLV MTLGUTTER, TYPDOWN SPOUT26' - 0"WOOD AND GLAZESLIDING DOORWOOD DECKWOOD RAILINGTTLL110LVVTTCHIMNEY CAP & FLUEEXTENSIONUUVV1ST FLOOR44' - 6"T.O. GRADE42' - 10 11/16"AVE. T.O. CURB41' - 0 1/16"1ST FL TOP PLATE52' - 6"2ND FLOOR53' - 6"2ND FL TOP PLATE61' - 6"30' - 0"PROPERTY LINE @ FRONTPROPERTY LINE30'-0" HEIGHT LIMITAVE. LEFT+40.99'45°8' - 0"8' - 0"5' - 6"PROPERTY LINE@ REART.O. ROOF RIDGE67' - 0 3/8"PAINTED 3-1/2"WD TRIM6" LAP SIDINGSTONE VENEER AROUNDCHIMNEYSTANDING SEAM METAL ROOFPAINTED GLV MTL GUTTER, TYPDOWNSPOUT26' - 0"36" x 60"DOUBLEHUNGEGRESSWINDOWLLCHIMNEY CAP & FLUEEXTENSIONMIN2' - 0"DDD1089' - 6"AVE. RIGHT+39.414' - 0"4 5 °TOTAL FIRST FLOOR WALL OPENING:30 SFTOTAL SECOND FLOOR WALL OPENING:75 SFPROPOSED FIRST FLOOR WALL OPENINGS:NO LIMITS (OK)PROPOSED SECOND FLOOR WALL OPENINGS:NO LIMITS (OK)OPENING NO.WIDTHHEIGHTQUANTITYOPENINGAREAWALL LEVELTOTALWALL AREAFIRE SEPARATIONDISTANCEDEGREE OFPROTECTIONALLOWABLEWALL OPENINGL230 SFSECOND155 SF≥ 30'PROTECTEDNO LIMITD1083' - 0"5' - 0"354 SFFIRST99 SF≥ 30'NO LIMIT3' - 0"6' - 0"121 SFFIRST89 SF≥ 30'NO LIMIT3' - 0"7' - 0"REAR ELEVATION ALLOWABLE WALL OPENINGSPROTECTEDPROTECTEDTOTAL FIRST FLOOR WALL OPENING:199 SFTOTAL SECOND FLOOR WALL OPENING:70 SFPROPOSED FIRST FLOOR WALL OPENINGS:199 / 817 = 24.3% (OK)PROPOSED SECOND FLOOR WALL OPENINGS:70 / 446 =15.7% (OK)OPENING NO.WIDTHHEIGHTQUANTITYOPENINGAREAWALL LEVELTOTALWALL AREAFIRE SEPARATIONDISTANCEDEGREE OFPROTECTIONALLOWABLEWALL OPENINGT225 SFSECOND196 SF8' - 0"PROTECTED25%ULV2' - 6"2' -6"220 SFSECOND126 SF8' - 7"25%2' - 6"4' - 0"345 SFFIRST240 SF4' - 0"15%3' - 0"5' - 0"235 SFFIRST240 SF4' - 0"15%2' - 6"3' - 6"PROPOSED LEFT ELEVATION ALLOWABLE WALL OPENINGSPROTECTEDPROTECTEDPROTECTED101184 SFFIRST162 SF13' - 6"PROTECTED45%12' - 0"7' - 0"V235 SFFIRST175 SF8' - 0"25%2' - 6"3' - 6"PROTECTEDT225 SFSECOND124 SF4' - 0"PROTECTED15%2' - 6"2' -6"PROJECT NUMBERDATEDRAWN BYCHECKED BYSCALENOTE -THE PURPOSE OF THE DRAWINGSPROVIDED IS TO SHOW GENERALARRANGEMENT OF REMODELING &ADDITIONS TO AN EXISTINGSTRUCTURE. ASSUMPTIONS HAVEBEEN MADE REGARDING THESTRUCTURAL & ARCHITECTURALCONDITIONS OF EXISTING WALLS,FLOORS & CEILINGS WHICH WILL NEEDTO BE VERIFIED & PERHAPS MODIFIEDAS THESE CONDITIONS ARE REVEALEDDURING CONSTRUCTION. THEDESIGNER DOES NOT ASSUME ANYRESPONSIBILITY FOR THE EXISTINGSTRUCTURE.DULON, INC.510.552.2641INFO@DULONDESIGNS.COMBURLINGAME, CALIFORNIA 94010DESIGN REVIEW PACKAGEAs indicated6/13/2018 2:41:52 PM2017.101805/09/2018JNJNA202MCGLOWN RESIDENCE834 CROSSWAY ROADBACK & LEFT ELEVATIONREVISION DESCRIPTION DATE1 PLAN CHECK REVIEW 01/10/20182 DESIGN REVIEW SUBMITTAL 06/13/2018SCALE: 1/4" = 1'-0"2PROPOSED LEFT ELEVATIONSCALE: 1/4" = 1'-0"1PROPOSED REAR ELEVATION 00 GARAGE39' - 2"00 GARAGE TOP PLATE47' - 2"PROPERTY LINE6" LAP SIDINGPAINTED ALUMINUMGARAGE DOORPAINTED 2x8 FASCIA BD.PAINTED GLV MTL GUTTER, TYP.00 GARAGE RIDGE54' - 2 7/32"00 GARAGE39' - 2"00 GARAGE TOP PLATE47' - 2"6" LAP SIDINGSOLID CORE WOODDOOR00 GARAGE RIDGE54' - 2 7/32"00 GARAGE39' - 2"00 GARAGE TOP PLATE47' - 2"PROPERTY LINE7' - 0"8' - 0"15' - 0"00 GARAGE RIDGE54' - 2 7/32"00 GARAGE39' - 2"00 GARAGE TOP PLATE47' - 2"15' - 0"7' - 0"8' - 0"00 GARAGE RIDGE54' - 2 7/32"1/2" SHIMWOOD TRIMHEADERPAPER FLASHING - LAP BLDG.PAPER OVERLAP BLDG. PAPER OVER CONT.GALV. MTL. DRIP EDGEGAL. MTL. CASING AND SEALANTGAL. MTL. CASING AND SEALANTPAPER FLASHING - LAP OVERBLDG. PAPER(2) 2x SILLWOOD TRIM6" SHIPLAP WD SIDING OVERBLDG. PAPER OVER 1/2" PLY.WD. OVER 2x6 WOOD STUDS@ 16" O.C. OVER 5/8" GYP.BD. W/ MIN. R-19 BATTINSULATIONROUGH WINDOW OPENING3-1/2" WD. TRIM ALL AROUNDPROJECT NUMBERDATEDRAWN BYCHECKED BYSCALENOTE -THE PURPOSE OF THE DRAWINGSPROVIDED IS TO SHOW GENERALARRANGEMENT OF REMODELING &ADDITIONS TO AN EXISTINGSTRUCTURE. ASSUMPTIONS HAVEBEEN MADE REGARDING THESTRUCTURAL & ARCHITECTURALCONDITIONS OF EXISTING WALLS,FLOORS & CEILINGS WHICH WILL NEEDTO BE VERIFIED & PERHAPS MODIFIEDAS THESE CONDITIONS ARE REVEALEDDURING CONSTRUCTION. THEDESIGNER DOES NOT ASSUME ANYRESPONSIBILITY FOR THE EXISTINGSTRUCTURE.DULON, INC.510.552.2641INFO@DULONDESIGNS.COMBURLINGAME, CALIFORNIA 94010DESIGN REVIEW PACKAGEAs indicated6/13/2018 12:56:47 PM2017.101805/09/2018JNJNA203MCGLOWN RESIDENCE834 CROSSWAY ROADGARAGE ELEVATIONS &WINDOW DETAILREVISION DESCRIPTION DATE1 PLAN CHECK REVIEW 01/10/20182 DESIGN REVIEW SUBMITTAL 06/13/2018SCALE: 1/4" = 1'-0"1GARAGE FRONT ELEVATIONSCALE: 1/4" = 1'-0"4GARAGE LEFT ELEVATIONSCALE: 1/4" = 1'-0"3GARAGE REAR ELEVATIONSCALE: 1/4" = 1'-0"2GARAGE RIGHT ELEVATIONSCALE: 3" = 1'-0"5EXTERIOR WINDOW HEAD / SILL @ WOOD SIDING DN1. THE INFORMATION REGARDING THE EXISTING CONDITIONS AND FEATURES SHOWNHEREIN ARE TAKEN FROM THE BEST AVAILBLE DATA AND SOURCES. HOWEVER THEINFORMATION IS NOT GUARANTEED. THE CONTRACTOR SHALL CONFIRM THE ACCURACYTHEREOF.2. PROPERTY LINES, EASEMENTS & EXISTING BUILDINGS SHOWN ON THIS SITE PLAN AREBASED UPON INFORMATION SUPPLIED BY OTHERS.3. CONFIRM EXACT LOCATION OF EASEMENTS.4. SITE LAYOUT, DIMENSIONS & UTILITIES SHOWN FOR REFERENCE ONLY.5. EXTERIOR LANDINGS SHALL BE 36" MIN. LENGTH WITH MAX CROSS SLOPE OF 2%.(CBC SEC. 1993.3.1)6. FOR ROOF INFORMATION SEE SHEET A1037. ALL EXISTING FENCING TO BE REPLACED WITH NEW WOOD FENCE.8. SEE LANDSCAPE PLAN, L101, FOR ALL HARDSCAPE INFORMATION, PLANT MATERIALSPECS AND LAYOUT.9. WATER RUN-OFF FROM REMODEL/ADDITION SHALL BE RETAINED ON SITE.10. ANY WORK IN THE CITY RIGHT-OF-WAY, SUCH AS PLACEMENT OF DEBRIS BIN INSTREET, WORK IN SIDEWALK AREA, PUBLIC EASEMENTS, AND UTILITY EASEMENTS, ISREQUIRED TO OBTAIN AN ENCROACHMENT PERMIT PRIOR TO STARTING WORK.11. CONSTRUCTION HOURS IN THE CITY PUBLIC RIGHT-OF-WAY ARE LIMITED TOWEEKDAYS AND NON-CITY HOLIDAYS BETWEEN 8:00 A.M. AND 5:00 P.M.12. THE PROJECT SHALL COMPLY WITH THE CITY'S NPDES PERMIT REQUIREMENTS TOPREVENT STORM WATER POLLUTION.13. REPLACE DAMAGED AND DISPLACED CURB, GUTTER AND/OR SIDEWALK FRONTINGSITE.14. SEWER BACKWATER PROTECTION CERTIFICATION IS REQUIRED FOR THEINSTALLATION OF ANY NEW SEWER FIXTURE PER ORDINANCE NO. 1710. THE SEWERBACKWATER PROTECTION CERTIFICATE IS REQUIRED PRIOR TO ISSUANCE OF BUILDINGPERMIT.15. THE SANITARY SEWER LATERAL (BUILDING SEWER) SHALL BE TESTED PERORDINANCE CODE CHAPTER 15.12. TESTING INFORMATION IS AVAILABLE AT THEBUILDING DEPARTMENT COUNTER. A SEWER LATERAL TEST ENCROACHMENT PERMIT ISREQUIRED.16. NO EXISTING TREE OVER 48" IN CIRCUMFERENCE AT 54" FROM BASE OF TREE MAYBE REMOVED WITHOUT A PROTECTED TREE REMOVAL PERMIT FROM THE PARKSDIVISION.17. IF PUBLIC WORKS REQUIRES SIDEWALK REPLACEMENT, POLICY FOR EXPANDINGWIDTH OF PLANTER STRIP NEEDS TO BE IMPLEMENTED.18. (N) AC EQUIPMENT TO BE LOCATED ON REAR 75% OF LOT. EQUPMENT SHALL NOTEXCEED MAX OUTDOOR NOISE LEVEL OF 60 DBA DAYTIME (7AM TO 10PM) OR 50 DBANIGHTTIME (10PM TO 7AM) AS MEASURED FROM PROPERTY LINE PER BURLINGAMEMUNICIPAL ZONING CODE 25.58.050.19. EXTERIOR BEARING WALLS LESS THAN FIVE FEET FROM THE PROPERTY LINE SHALLBE ONE-HOUR FIRE-RATED CONSTRUCTION20. REPLACE ALL CURB, GUTTER, DRIVEWAY AND SIDEWALK FRONTING SITE, PLUG ALLEXISTING SANITARY SEWER LATERAL CONNECTIONS AND INSTALL A NEW 4" LATERAL, ALLWATER LINE CONNECTIONS TO CITY WATER MAINS FOR SERVICES OR FIRE LINE ARE TOBE INSTALLED PER CITY STANDARD PROCEDURES AND SPECIFICATION, AND ANY OTHERUNDERGROUND UTILITY WORKS WITHIN CITY’S RIGHT-OF-WAY.SITE PLAN NOTES:ADDRESSSETBACKAVERAGE FRONT SETBACKS834 CROSSWAY ROAD 18.60'830 CROSSWAY ROAD 20.15'826 CROSSWAY ROAD 19.82'822 CROSSWAY ROAD 19.62'AVERAGE FRONT SETBACK: 18.62'814 CROSSWAY ROAD 14.91'A2021C R O S SW A Y R O A D A2012A2011A2022A2031A2034A2033A2032REAR SETBACK15' - 0" MINSETBACK4'-0"SIDE834 CROSSWAY ROADNEW SINGLE FAMILY RESIDENCEAPN: 029-021-310LOT AREA: 6,737 SFLEFT SIDE4'-0"PROPOSEDS E T B A C K 4 '-0 " S I D E 1ST AND 2ND FROM FRONT SETBACK20' - 1"1ST AND 2ND FROM REAR SETBACK67' - 0" PROPOSEDOUTLINE OFPROPOSED2ND FLOOR(E) NEIGHBORBUILDING OUTLINE(E) NEIGHBORBUILDING OUTLINE(E) NEIGHBORBUILDING OUTLINE(E) NEIGHBORBUILDING OUTLINE(E) NEIGHBORBUILDING OUTLINE(E) NEIGHBORBUILDING OUTLINE± 3' - 9"± 4' - 0"± 3' - 6"(E ) C O N CR E T E S I DE W A L K NEW DETACHEDGARAGE40.4937.7840.5941.49FF= 45.0041.4941.224 9 .9 9 S 3 9 °2 4 '3 9 "E 164.40S48°48'16"W155.09N54°22'46"E35.92 S 54°51'5 4"E 41.6537.5042.8541.3742.4442.8540.6540.0738.6339.4639.5337.351 ' - 2 "29' - 1"(N) CONCRETEDRIVEWAYCOVEREDPORCH(E) SHED TOBE DEMO'ED(E) 16" PALM TOBE REMOVED(E) 48" TREETO BE REMAIN(E) 4" MAPLETREE TO BEREMOVED(E) 4" TREE TOBE REMOVED(E) 4" TREE TOBE REMOVEDOUTLINE OFPROPOSED1ST FLOORREAR 30% 48' - 11"SEWER LINENEW CLEANOUTWATERPG&EOVERHEADTO PORCH18' - 8"9 ' - 6 ' M I N PROJECT NUMBERDATEDRAWN BYCHECKED BYSCALENOTE -THE PURPOSE OF THE DRAWINGSPROVIDED IS TO SHOW GENERALARRANGEMENT OF REMODELING &ADDITIONS TO AN EXISTINGSTRUCTURE. ASSUMPTIONS HAVEBEEN MADE REGARDING THESTRUCTURAL & ARCHITECTURALCONDITIONS OF EXISTING WALLS,FLOORS & CEILINGS WHICH WILL NEEDTO BE VERIFIED & PERHAPS MODIFIEDAS THESE CONDITIONS ARE REVEALEDDURING CONSTRUCTION. THEDESIGNER DOES NOT ASSUME ANYRESPONSIBILITY FOR THE EXISTINGSTRUCTURE.DULON, INC.510.552.2641INFO@DULONDESIGNS.COMBURLINGAME, CALIFORNIA 94010DESIGN REVIEW PACKAGEAs indicated6/13/2018 1:03:38 PM2017.101805/09/2018PDJNA100MCGLOWN RESIDENCE834 CROSSWAY ROADPROPOSED SITE PLANSCALE: 1/8" = 1'-0"1(N) SITE PLANREVISION DESCRIPTION DATE1 PLAN CHECK REVIEW 01/10/20182 DESIGN REVIEW SUBMITTAL 06/13/2018N 1. ALL DIMENSIONS ARE FACE OF WALL U.O.N.2. G.C. TO COORDINATE WITH ARCHITECT FOR APPROVAL PRIOR TO SELECTION /INSTALLATION OF MATERIALS.3. ROOFING SYSTEM SHALL BEAR U.L. LISTING AS A CLASS "A" SYSTEM. ALLMANUFACTURED MATERIALS USED SHALL BEAR THE APPROPRIATE U.L. LABEL.4. ROOF EAVES WILL NOT PROJECT WITHIN TWO FEET OF THE PROPERTY LINE2016 CRC § TABLE R302.1(1) OR 2016 CBC TABLE 705.2GENERAL NOTES:OUTLINE OF 2ND FLOORSTANDING SEAMINGMETAL ROOF, TYP.PAINTED METALGUTTER, TYP.DSDSDSDSDSDSDSDSDSDSDSDS9" / 12"9" / 12"9" / 12"9" / 12"9" / 12"9" / 12"9" / 12"9" / 12"4" / 12"9" / 12"9" / 12"CHIMNEY CAP & FLUEDS9" / 12"DSDS7" / 12"7" / 12"PROJECT NUMBERDATEDRAWN BYCHECKED BYSCALENOTE -THE PURPOSE OF THE DRAWINGSPROVIDED IS TO SHOW GENERALARRANGEMENT OF REMODELING &ADDITIONS TO AN EXISTINGSTRUCTURE. ASSUMPTIONS HAVEBEEN MADE REGARDING THESTRUCTURAL & ARCHITECTURALCONDITIONS OF EXISTING WALLS,FLOORS & CEILINGS WHICH WILL NEEDTO BE VERIFIED & PERHAPS MODIFIEDAS THESE CONDITIONS ARE REVEALEDDURING CONSTRUCTION. THEDESIGNER DOES NOT ASSUME ANYRESPONSIBILITY FOR THE EXISTINGSTRUCTURE.DULON, INC.510.552.2641INFO@DULONDESIGNS.COMBURLINGAME, CALIFORNIA 94010DESIGN REVIEW PACKAGEAs indicated6/13/2018 12:56:29 PM2017.101805/09/2018PDJNA103MCGLOWN RESIDENCE834 CROSSWAY ROADROOF PLANSREVISION DESCRIPTION DATE1 PLAN CHECK REVIEW 01/10/20182 DESIGN REVIEW SUBMITTAL 06/13/2018SCALE: 1/4" = 1'-0"2PROPOSED ROOF PLANSCALE: 1/4" = 1'-0"1GARAGE ROOF PLANNN DNUPDNUPSTAINED FINISH CONCRETELANDSCAPE LEGENDLAWN, ±1020 SF BOLERO BLEND, DELTA BLUEGASS CO.BARK MULCH - BROWN / MOCHATREE, SEE PLANT SCHEDULESHRUBS, SEE PLANT SCHEDULESMALL PLANT, SEE SCHEDULEFLOWERS, SEE SCHEDULE(E ) C O N CR E T E S I D E W A L KT5 T5S6S6S6S6S6S6AT211111S2S2S2T4S4S4S4S4S4S4S4S4S4S4S4T1T3T3T311111111111S4S4S4S4S4S4S5S5S5S5S5S522222222B11T3S4S4S4S4S422222221T3T3T3111111S3S3S3S3S3S3AAAAAAAAAABBBBBBBBBBB(E) 16" PALM TOBE REMOVED(E) 4" MAPLETREE TO BEREMOVED(E) 4" TREE TOBE REMOVED(E) 30" TREETO BE REMAIN(E) 48" TREETO BE REMAIN(N) WOOD FENCEB(N) CONCRETE DRIVEWAY(N) 9' WIDE x 6' HIGHSWING GATE(N) CONCRETE PATH(N) TWO CARGARAGE(N) RESIDENCE(N) CONCRETEDRIVEWAY APPROACH(N) LAWN(N) LAWN(N) BARK MULCHC R O S S W A Y R O A D S3S3S3S3S3S1S1S1S1S1 S1 S1S2S2S2S2111111BBBBBBBBS2S2S2S2T1S31. PROTECT ALL TREES TO REMAIN.2. NO TREE OVER 48" IN DIAMETER MAY BE REMOVED W/O PERMIT FROMPARKS DIVISION.LANDSCAPE NOTES:IRRIGATED AREAS:TURF IRRIGATED AREA = 1,153 SFNON-TURF IRRIGAGTED AREA = 1,607 SF(N) CONTROL VALVES, TYP.(N) PVC IRRIGATION LINE, TYP.(N) SPRINKLER HEAD, TYP.(N) IRRIGATION DRIP LINE, TYP.(N) TWO CARGARAGE(N) RESIDENCEC R O S SW A Y R O A D PROJECT NUMBERDATEDRAWN BYCHECKED BYSCALENOTE -THE PURPOSE OF THE DRAWINGSPROVIDED IS TO SHOW GENERALARRANGEMENT OF REMODELING &ADDITIONS TO AN EXISTINGSTRUCTURE. ASSUMPTIONS HAVEBEEN MADE REGARDING THESTRUCTURAL & ARCHITECTURALCONDITIONS OF EXISTING WALLS,FLOORS & CEILINGS WHICH WILL NEEDTO BE VERIFIED & PERHAPS MODIFIEDAS THESE CONDITIONS ARE REVEALEDDURING CONSTRUCTION. THEDESIGNER DOES NOT ASSUME ANYRESPONSIBILITY FOR THE EXISTINGSTRUCTURE.DULON, INC.510.552.2641INFO@DULONDESIGNS.COMBURLINGAME, CALIFORNIA 94010DESIGN REVIEW PACKAGE 1/8" = 1'-0"6/13/2018 12:59:03 PM2017.101805/09/2018JNJNL101MCGLOWN RESIDENCE834 CROSSWAY ROADLANDSCAPE &IRRIGATION PLANSCALE: 1/8" = 1'-0"1PROPOSED LANDSCAPE PLANPLANTING SCHEDULENO SCIENTIFIC NAME COMMON NAME QUANTITY SIZE DESCRIPTION1 CAREX RADIATA EASTERN STAR SEDGE 37 1 GAL2 LIRIOPE MUSCARI 'VARIEGATA' LILYTURF 15 1 GALA IBERIS SEMPERVIRENS EVERGREEN CANDYTUFT 11 1 GALB AUBRIETA AUBRIETA 21 1 GALS1 HYDRANGEA ARBORESCENS 'ANNABELLE' ANNABELLE HYDRANGEA 7 5 GALS2 HYDRANGEA MACROPHYLLA 'BALIMER' ENDLESS SUMMER HYDRANGEA 11 5 GALS3 PENNISETUM SETACEUM ROSE FOUNTAIN GRASS 12 5 GALS4 PRUNUS LAUROCERASUS 'SCHIPKAENSIS' SCHIPKA CHERRY LAUREL 22 15 GALS5 SPIRAEA X VANHOUTTEI VANHOUTTEI SPIREA 6 15 GALS6 SYRINGA VULGARIS 'SENSATION' SENSATION LILAC 11 15 GALT1 (E) TREE TO REMAIN N/A 2 N/A (E) TREE TO REMAINT2 CORNUS FLORIDA RUBA PINK FLOWERING DOGWOOD 1 15 GALT3 BETULA PENDULA SILVER BIRCH 7 24" BOXT4 MAGNOLIA ACUMINATA YELLOW BIRD MAGNOLIA 1 15 GALT5 GINKO BILOBA MAIDENHAIR TREE 2 24" BOXREVISION DESCRIPTION DATE1 PLAN CHECK REVIEW 01/10/20182 DESIGN REVIEW SUBMITTAL 06/13/2018SCALE: 1/8" = 1'-0"2PROPOSED IRRIGATION PLAN CITY OF BURLINGAME Community Development Department M E M O R A N D U M DATE: March 22, 2018 Director's Report TO: Planning Commission Meeting Date: March 26, 2018 FROM: ‘Amelia Kolokihakaufisi, Associate Planner SUBJECT: FYI – REVIEW OF REVISIONS REQUESTED BY THE PLANNING COMMISSION TO A PREVIOUSLY APPROVED DESIGN REVIEW PROJECT AT 305 BURLINGAME AVENUE, ZONED R-1. Summary: An application for Design Review for a new, two-story single-family dwelling at 305 Burlingame Avenue, zoned R-1, was approved by the Planning Commission on February 26, 2018 (see attached February 26, 2018 Planning Commission Meeting Minutes). At that hearing, the Planning Commission voted to approve the project based upon the following revisions being reviewed by the Commission as an FYI item, prior to the issuance of a building permit:  that the design of the front porch gable be revised to match the Tudor style of the other gables on the house;  that trim be added around the front entry door to match Tudor style of the house;  that landscaping be added along the front elevation; and  that the detached garage move off the property line by at least one foot. The applicant submitted revised plans that show that the requested revisions have been addressed. The roof plan (sheet A-1.1) and new front elevation (sheet A-3) reflect changes to the front porch gable that match the other gables on the house. A thicker trim has been added around the front entry door. Landscaping added along the front elevation include: enlarged lawn area that reduces the width of the paved pathway to the porch, planter boxes that line the pathway to the porch, and shrubbery between the porch and driveway. The detached garage has been moved off the rear and right side property lines by one foot, respectively. No other changes are proposed to the design of the house. A building permit has not yet been issued for the project. If the Commission feels there is a need for more study, this item may be placed on an action calendar for a public hearing with direction to the applicant. ‘Amelia Kolokihakaufisi Associate Planner Attachments: February 26, 2018 Planning Commission Minutes Originally Approved plans (before), date stamped February 13, 2018 Proposed plans (after), date stamped March 13, 2018